Search NASA⌕ Search

SEARCH · Search NASA

Results for “GW method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Dispersive characteristics and longitudinal resonance properties in a relativistic backward wave oscillator with the coaxial arbitrary-profile slow-wave structure

The method for calculating the dispersion relations of the slow-wave structures (SWSs) with arbitrary geometrical structures is studied in detail by using the Fourier series expansion. In addition, dispersive characteristics and longitudinal resonance properties of the SWSs with the cosinusoidal, trapezoidal, and rectangular corrugations are analyzed by numerical calculation. Based on the above discussion, a comparison on an L-band coaxial relativistic backward wave oscillator (BWO) and an L-band coaxial BWO with a coaxial extractor is investigated in detail with particle-in-cell KARAT code (V. P. Tarakanov, Berkeley Research Associates, Inc., 1992). Furthermore, experiments are carried out at the TORCH-01 accelerator under the low guiding magnetic field. At diode voltage of 647 kV, beam current of 9.3 kA, and guiding magnetic field strength of 0.75 T, the microwave is generated with power of 1.07 GW, mode of TM{sub 01}, and frequency of 1.61 GHz. That is the first experimental report of the L-band BWO.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Impact of Utility Tariff Evolution on Behind-the-Meter PV Adoption

This analysis uses a new method to link the NREL Regional Energy Deployment System (ReEDS) capacity expansion model with the NREL distributed generation market demand model (dGen) to explore the impact that the evolution of retail electricity tariffs can have on the adoption of distributed photovoltaics (DPV). The evolution most notably takes the form of decreased mid-day electricity costs, as low-cost PV reduces the marginal cost of electricity during those hours and the changes are subsequently communicated to electricity consumers through tariffs. We find that even under the low PV prices of the new SunShot targets the financial performance of DPV under evolved tariffs still motivates behind-the-meter adoption, despite significant reduction in the costs of electricity during afternoon periods driven by deployment of cheap utility-scale PV. The amount of DPV in 2050 in these low-cost futures ranged from 206 GW to 263 GW, a 13-fold and 16-fold increase over 2016 adoption levels respectively. From a utility planner's perspective, the representation of tariff evolution has noteworthy impacts on forecasted DPV adoption in scenarios with widespread time-of-use tariffs. Scenarios that projected adoption under a portfolio of time-of-use tariffs, but did not represent the evolution of those tariffs, predicted up to 36 percent more DPV in 2050, compared to scenarios that did not represent that evolution. Lastly, we find that a reduction in DPV deployment resulting from evolved tariffs had a negligible impact on the total generation from PV - both utility-scale and distributed - in the scenarios we examined. Any reduction in DPV generation was replaced with utility-scale PV generation, to arrive at the quantity that makes up the least-cost portfolio.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Intrinsic point defects in aluminum antimonide

Calculations within density functional theory on the basis of the local density approximation are carried out to study the properties of intrinsic point defects in aluminum antimonide. Special care is taken to address finite-size effects, band gap error, and symmetry reduction in the defect structures. The correction of the band gap is based on a set of GW calculations. The most important defects are identified to be the aluminum interstitial Al{sub i,Al}{sup 1+}, the antimony antisites Sb{sub Al}{sup 0} and Sb{sub Al}{sup 1+}, and the aluminum vacancy V{sub Al}{sup 3-}. The intrinsic defect and charge carrier concentrations in the impurity-free material are calculated by self-consistently solving the charge neutrality equation. The impurity-free material is found to be n-type conducting at finite temperatures.

36 MATERIALS SCIENCE↗

NREL and DONG Energy Collaboration for Grid Simulator Controls and Testing: Cooperative Research and Development Final Report, CRADA Number CRD-13-527

The National Renewable Energy Laboratory (NREL) and DONG Energy are interested in collaborating for the development of control algorithms, modeling, and grid simulator testing of wind turbine generator systems involving NWTC's advanced Controllable Grid Interface (CGI). NREL and DONG Energy will work together to develop control algorithms, models, test methods, and protocols involving NREL's CGI, as well as appropriate data acquisition systems for grid simulation testing. The CRADA also includes work on joint publication of results achieved from modeling and testing efforts. Further, DONG Energy will send staff to NREL on a long-term basis for collaborative work including modeling and testing. NREL will send staff to DONG Energy on a short-term basis to visit wind power sites and participate in meetings relevant to this collaborative effort. DOE has provided NREL with over 10 years of support in developing custom facilities and capabilities to enable testing of full-scale integrated wind turbine drivetrain systems in accordance with the needs of the US wind industry. NREL currently operates a 2.5MW dynamometer and is in the processes of commissioning a 5MW dynamometer and a grid simulator (referred to as a 'Controllable Grid Interface' or CGI). DONG Energy is the market leader in offshore wind power development, with currently over 1 GW of on- and offshore wind power in operation, and 1.3 GW under construction. DONG Energy has on-going R&D projects involving high voltage DC (HVDC) transmission.

17 WIND ENERGY↗

Methods for Assessing Opportunities for Ring Dam Pumped Storage Hydropower

There is growing interest in new pumped storage hydropower (PSH) deployment to provide a range of grid flexibility, reliability, and resiliency services under an evolving and uncertain future power sector. The National Laboratory of the Rockies develops open PSH resource assessment and cost modeling tools to help evaluate PSH deployment opportunities, and this report describes expansions to those tools to consider an additional PSH system configuration - ring-dam reservoirs built on flat topographical features that are constructed from roller-compacted concrete material. This reservoir type is common among current PSH proposals and requires new methods to identify sites with this reservoir geometry throughout the United States and characterize the associated dam cost. Cost characterization for ring dam reservoirs required collecting historical dam cost data for earthen, rockfill, and roller-compacted concrete dams and regressing equations that relate costs between alternative materials. The ring dam site identification algorithm follows a 5-step procedure to identify circular geometry reservoirs. Once ring dam reservoirs are identified, they are then paired with potential dry-gully reservoirs, and the full set of potential paired reservoirs is cost-optimized to produce a least-cost set of potential PSH sites with no overlapping reservoirs. The resulting analysis found 1,663 ring-dam to dry-gully systems in the contiguous United States that are lower cost than any overlapping dry-gully to dry-gully systems, 29 in Alaska, and none in Hawaii or Puerto Rico. These systems constitute 1.5 TW of capacity in the contiguous United States and nearly 29 GW in Alaska, demonstrating that under suitable topography and head, ring-dam systems can provide cost-effective PSH opportunities. The greatest density of these opportunities are found in the intermountain west where there are mesas and flat land at bases of mountain ranges, but continued work could incorporate additional site characteristics or consider more complex reservoir shapes to find additional PSH deployment opportunities.

13 HYDRO ENERGY↗

Electronic excitations of bulk LiCl from many-body perturbation theory

We present the quasiparticle band structure and the optical excitation spectrum of bulk LiCl, using many-body perturbation theory. Density-functional theory is used to calculate the ground-state geometry of the system. The quasiparticle band structure is calculated within the GW approximation. Taking the electron-hole interaction into consideration, electron-hole pair states and optical excitations are obtained by solving the Bethe-Salpeter equation for the electron-hole two-particle Green function. The calculated band gap is 9.5 eV, which is in good agreement with the experimental result of 9.4 eV. And the calculated optical absorption spectrum, which contains an exciton peak at 8.8 eV and a resonant-exciton peak at 9.8 eV, is also in good agreement with experimental data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visible-range hybrid femtosecond systems based on a XeF(C-A) amplifier: state of the art and prospects

Results of experimental and theoretical investigations of the hybrid (solid state/gas) visible-range femtosecond systems THL-100 (IHCE SB RAS) and THL-30 (P.N. Lebedev Physics Institute) based on a Ti : sapphire front end and a photochemical XeF(C-A) amplifier are reported. The front end generates 50-fs optical pulses with the second-harmonic (475 nm) energy of up to 5 mJ. The active medium of the amplifier is produced in a mixture XeF{sub 2} - N{sub 2} subjected to VUV radiation of xenon excited by an electron beam. The computer model is developed for calculating parameters of the XeF(C - A) amplifier, which is in a good agreement with experiments. In the THL-100 system with the 25-cm output aperture of the XeF(C-A) amplifier, a record visible-range femtosecond radiation peak power of 14 GW was obtained in a 50-fs pulse with the time contrast of above 10{sup 8}. The measured power of an amplified spontaneous emission of the XeF(C-A) amplifier in the angle of 0.2 mrad was 32 W. The result obtained testifies that the hybrid approach to the development of ultrahigh-power systems provides a high time contrast of radiation (greater than 10{sup 12} for the projected peak power of 100 TW). In the THL-30 system, prospects for shortening an amplified femtosecond pulse are studied and it is experimentally shown that by compensating a third-order dispersion in a hybrid system one can obtain pulses with duration of at least 27 fs with a recompression of amplified pulses in bulk glass. Also, a new phenomenon was observed of spectrum broadening and self-compression of negatively chirped femtosecond pulses in the visible range under a nonlinear interaction of wide-aperture beams with fused silica. This result opens prospects for development of the new methods of selfcompression for femtosecond pulses that are lacking physical limitations on pulse energy and realisation of self-compression of amplified pulses in the output window of the XeF(C-A) amplifier. (extreme light fields and their applications)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rooftop Solar Photovoltaic Technical Potential in the United States. A Detailed Assessment

How much energy could be generated if PV modules were installed on all of the suitable roof area in the nation? To answer this question, we first use GIS methods to process a lidar dataset and determine the amount of roof area that is suitable for PV deployment in 128 cities nationwide, containing 23% of U.S. buildings, and provide PV-generation results for a subset of those cities. We then extend the insights from that analysis to the entire continental United States. We develop two statistical models--one for small buildings and one for medium and large buildings--and populate them with geographic variables that correlate with rooftop's suitability for PV. We simulate the productivity of PV installed on the suitable roof area, and present the technical potential of PV on both small buildings and medium/large buildings for every state in the continental US. Within the 128 cities covered by lidar data, 83% of small buildings have a location suitable for a PV installation, but only 26% of the total rooftop area of small buildings is suitable for development. The sheer number of buildings in this class, however, gives small buildings the greatest technical potential. Small building rooftops could accommodate 731 GW of PV capacity and generate 926 TWh/year of PV energy, approximately 65% of rooftop PV's total technical potential. We conclude by summing the PV-generation results for all building sizes and therefore answering our original question, estimating that the total national technical potential of rooftop PV is 1,118 GW of installed capacity and 1,432 TWh of annual energy generation. This equates to 39% of total national electric-sector sales.

14 SOLAR ENERGY↗

Rooftop Solar Photovoltaic Technical Potential in the United States

How much energy could we generate if PV modules were installed on all of the suitable roof area in the nation? To answer this question, we first use GIS methods to process a lidar dataset and determine the amount of roof area that is suitable for PV deployment in 128 cities nationwide, containing 23% of U.S. buildings, and provide PV-generation results for a subset of those cities. We then extend the insights from that analysis to the entire continental United States. We develop two statistical models -- one for small buildings and one for medium and large buildings -- and populate them with geographic variables that correlate with rooftop's suitability for PV. We simulate the productivity of PV installed on the suitable roof area, and present the technical potential of PV on both small buildings and medium/large buildings for every state in the continental US. Within the 128 cities covered by lidar data, 83% of small buildings have a location suitable for a PV installation, but only 26% of the total rooftop area of small buildings is suitable for development. The sheer number of buildings in this class, however, gives small buildings the greatest technical potential. Small building rooftops could accommodate 731 GW of PV capacity and generate 926 TWh/year of PV energy, approximately 65% of rooftop PV's total technical potential. We conclude by summing the PV-generation results for all building sizes and therefore answering our original question, estimating that the total national technical potential of rooftop PV is 1,118 GW of installed capacity and 1,432 TWh of annual energy generation. This equates to 39% of total national electric-sector sales.

14 SOLAR ENERGY↗

Plasmon-enhanced reverse water gas shift reaction over oxide supported Au catalysts

We show that localized surface plasmon resonance (LSPR) can enhance the catalytic activities of different oxide-supported Au catalysts for the reverse water gas shift (RWGS) reaction. Oxide-supported Au catalysts showed 30 to 1300% higher activity for RWGS under visible light compared to dark conditions. Au/TiO2 catalyst prepared by the deposition-precipitation (DP) method with 3.5 nm average Au particle size showed the highest activity for the RWGS reaction. Visible light is converted into chemical energy for this reaction with up to a 5% overall efficiency. A shift in the apparent activation energy (from 47 kJ mol(-1) in dark to 35 kJ mol(-1) in light) and apparent reaction order with respect to CO2 (from 0.5 in dark to 1.0 in light) occurs due to the LSPR. Our kinetic results indicate that the LSPR increases the rate of either the hydroxyl hydrogenation or carboxyl decomposition more than any other steps in the reaction network.

Upadhye, AA↗

Characterisations of the HinOTORI telescope with a three-color imager at Ali Observatory in Western Tibet

HinOTORI is a new telescope supported by an international collaboration project between China and Japan. It is a 50 centimeter telescope equipped with simultaneous three-color imagers (u',R C , and I C bands). It is located at Ali Observatory at an altitude of 5100m. Thanks to the high altitude and extreme dryness, Ali site is one of the most suitable sites for optical astrometry. HinOTORI telescope aims at detecting optical transients such as the counterparts of gravitational wave (GW) sources, supernovae, gamma-ray bursts (GRB) and so on. This paper describes the site information, design of simultaneous three-color optical layout, system instruments and whole control system. We also report some telescope characterisations for three bands (u'/R C /I C ) respectively, such as Hartmann constant (0.49"/0.56"/0.60"), best focus position (3.922/3.920/3.903 mm), PSF FWHM size (3.755/3.328/3.167pixels), total transmittance and limiting magnitude (15.69/17.57/17.05mag, 10 σ 30 seconds exposure time). With different airmass observation data, the atmospheric extinction coefficients of three bands (0.366/0.061/0.026) were also derived.

47 OTHER INSTRUMENTATION↗

The Fate of Neutron Star Binary Mergers

Following merger, a neutron star (NS) binary can produce roughly one of three different outcomes: (1) a stable NS, (2) a black hole (BH), or (3) a supramassive, rotationally supported NS, which then collapses to a BH following angular momentum losses. Which of these fates occur and in what proportion has important implications for the electromagnetic transient associated with the mergers and the expected gravitational wave (GW) signatures, which in turn depend on the high density equation of state (EOS). Here we combine relativistic calculations of NS masses using realistic EOSs with Monte Carlo population synthesis based on the mass distribution of NS binaries in our Galaxy to predict the distribution of fates expected. For many EOSs, a significant fraction of the remnants are NSs or supramassive NSs. This lends support to scenarios in which a quickly spinning, highly magnetized NS may be powering an electromagnetic transient. This also indicates that it will be important for future GW observatories to focus on high frequencies to study the post-merger GW emission. Even in cases where individual GW events are too low in signal to noise to study the post merger signature in detail, the statistics of how many mergers produce NSs versus BHs can be compared with our work to constrain the EOS. To match short gamma-ray-burst (SGRB) X-ray afterglow statistics, we find that the stiffest EOSs are ruled out. Furthermore, many popular EOSs require a significant fraction of ∼60%–70% of SGRBs to be from NS–BH mergers rather than just binary NSs.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical properties of alkali halide crystals from all-electron hybrid TD-DFT calculations

We present a study of the electronic and optical properties of a series of alkali halide crystals AX, with A = Li, Na, K, Rb and X = F, Cl, Br based on a recent implementation of hybrid-exchange time-dependent density functional theory (TD-DFT) (TD-B3LYP) in the all-electron Gaussian basis set code CRYSTAL. We examine, in particular, the impact of basis set size and quality on the prediction of the optical gap and exciton binding energy. The formation of bound excitons by photoexcitation is observed in all the studied systems and this is shown to be correlated to specific features of the Hartree-Fock exchange component of the TD-DFT response kernel. All computed optical gaps and exciton binding energies are however markedly below estimated experimental and, where available, 2-particle Green’s function (GW-Bethe-Salpeter equation, GW-BSE) values. We attribute this reduced exciton binding to the incorrect asymptotics of the B3LYP exchange correlation ground state functional and of the TD-B3LYP response kernel, which lead to a large underestimation of the Coulomb interaction between the excited electron and hole wavefunctions. Considering LiF as an example, we correlate the asymptotic behaviour of the TD-B3LYP kernel to the fraction of Fock exchange admixed in the ground state functional c{sub HF} and show that there exists one value of c{sub HF} (∼0.32) that reproduces at least semi-quantitatively the optical gap of this material.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prospects for joint observations of gravitational waves and gamma rays from merging neutron star binaries

The detection of the events GW150914 and GW151226, both consistent with the merger of a binary black hole system (BBH), opened the era of gravitational wave (GW) astronomy. Besides BBHs, the most promising GW sources are the coalescences of binary systems formed by two neutron stars or a neutron star and a black hole. These mergers are thought to be connected with short Gamma Ray Bursts (GRBs), therefore combined observations of GW and electromagnetic (EM) signals could definitively probe this association. We present a detailed study on the expectations for joint GW and high-energy EM observations of coalescences of binary systems of neutron stars with Advanced Virgo and LIGO and with the Fermi gamma-ray telescope. To this scope, we designed a dedicated Montecarlo simulation pipeline for the multimessenger emission and detection by GW and gamma-ray instruments, considering the evolution of the GW detector sensitivities. We show that the expected rate of joint detection is low during the Advanced Virgo and Advanced LIGO 2016–2017 run; however, as the interferometers approach their final design sensitivities, the rate will increase by ∼ a factor of ten. Future joint observations will help to constrain the association between short GRBs and binary systems and to solve the puzzle of the progenitors of GWs. Comparison of the joint detection rate with the ones predicted in this paper will help to constrain the geometry of the GRB jet.

79 ASTRONOMY AND ASTROPHYSICS↗

Transversal and longitudinal mode selections in double-corrugation coaxial slow-wave devices

To reduce the dimensions of relativistic backward wave oscillators (RBWOs) operating in the low frequency regime of less than 2 GHz, the theory of transversal and longitudinal mode selections are introduced in this paper. The transversal mode selection is achieved using the property of ''surface wave'' of the coaxial slow-wave structure (SWS) to excite the quasi transverse electromagnetic (quasi-TEM) mode without the higher transverse magnetic (TM) modes and it is proved that the coaxial SWS may decrease the transversal dimension of the SWS sections. In addition, the S-parameter method is employed to investigate the longitudinal resonant characteristic of the finite-length SWS, and the scheme of longitudinal mode selection is put forward. It is proposed that the introduction of a well-designed coaxial extractor to slow-wave devices can help to achieve the longitudinal mode selection and reduce the period number of the SWS, which not only can make the devices more compact, but also can avoid the destructive competition between various longitudinal modes, therefore can enhance the efficiency and stabilize the frequency. To sum up, the physical mechanisms of transversal and longitudinal mode selections ensure that the microwave is produced with a single mode and a narrow band. Based on the above discussion, a compact L-band coaxial RBWO is investigated and optimized in detail with the particle-in-cell KARAT code (V. P. Tarakanov, Berkeley Research Associates, Inc., 1992). In simulation, the L-band coaxial RBWO, driven by a 700 kV, 11 kA electron beam, comes to a nonlinear steady state in 20 ns. High-power microwave of quasi-TEM mode is generated with an average power of 2.66 GW, a frequency of 1.6 GHz, and power conversion efficiency of 34.5% in durations of 30-60 ns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling the impact of extreme summer drought on conventional and renewable generation capacity: Methods and a case study on the Eastern U.S. power system

Across recent years, there has been a growing prevalence of extreme weather events throughout the United States, posing significant challenges to the reliable and resilient operation of power systems. Specifically, summer droughts threaten to severely reduce available generation capacity to meet regional electricity demand, potentially leading to power outages. This underscores the importance of accurate resource adequacy (RA) assessment to ensure the reliable operation of the nation’s energy infrastructure. Accurately evaluating the usable capacity of regional generation fleets is a challenging undertaking due to the intricate interactions between power systems and hydro-climatic systems. Here, this paper proposes a systematic and analytical framework to evaluate the impacts of extreme summer drought events on the available capacity of various generating technologies, incorporating both meteorological and hydrologic factors. The framework provides detailed plant-level capacity derating models for hydroelectric, thermoelectric, and renewable power plants, facilitating evaluations with high temporal and spatial resolution. The application of the proposed impact assessment framework to the 2025 generation fleet of the real-world power system within the PJM and SERC regions of the United States yields insightful results. By analyzing the daily usable capacity of 6,055 at-risk generators across the study region, it shows that the summer capacity deration is most significant for hydroelectric and once-through thermal power plants, followed by recirculating thermal power plants and combustion turbines. In the event of the recurrence of the 2007 southeastern summer drought event in the near future, the generation fleet could experience a substantial reduction in available capacity, estimated at approximately 8.5 GW, compared to typical summer conditions. The sensitivity analysis reveals that the usable capacity of the generation fleet would suffer an even more significant decrease under conditions of increasingly severe summer droughts. The proposed approach and the findings of this study provide valuable methodologies and insights, empowering stakeholders to bolster the resilience of power systems against the potentially devastating effects of future extreme drought events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Validity of virial theorem in all-electron mixed basis density functional, Hartree–Fock, and GW calculations

In this paper, we calculate kinetic and potential energy contributions to the electronic ground-state total energy of several isolated atoms (He, Be, Ne, Mg, Ar, and Ca) by using the local density approximation (LDA) in density functional theory, the Hartree–Fock approximation (HFA), and the self-consistent GW approximation (GWA). To this end, we have implemented self-consistent HFA and GWA routines in our all-electron mixed basis code, TOMBO. We confirm that virial theorem is fairly well satisfied in all of these approximations, although the resulting eigenvalue of the highest occupied molecular orbital level, i.e., the negative of the ionization potential, is in excellent agreement only in the case of the GWA. We find that the wave function of the lowest unoccupied molecular orbital level of noble gas atoms is a resonating virtual bound state, and that of the GWA spreads wider than that of the LDA and thinner than that of the HFA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗