Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Gaining insight into lithium-ion battery degradation by a calorimetric approach

With the growing demand for lithium-ion batteries (LIBs) in transportation and renewable energy sectors, ensuring reliability and mitigating degradation are crucial challenges for their widespread deployment. Here this study investigates the relationship between thermal characteristics and degradation/reliability by developing an in-situ heat measurement methodology for LIBs operating under grid services. Using adiabatic mode-based calorimetry, we examine the thermal behavior of two commercial cells with different cathode chemistries (Ni-rich layered oxide and olivine) before and after two years of grid service (peak shaving) and demonstrate a strong correlation between thermal characteristics and electrochemical performance and its degradation. By further analyzing the heat sources separation (differentiating between irreversible and reversible heat), we disclose the underlying degradation mechanisms of LIBs. These findings emphasize the critical role of thermal characteristics in determining LIB reliability and deterioration, while the obtained heat data can aid in the development and calibration of LIB state-of-health models for grid applications.

25 ENERGY STORAGE↗

Towards time-resolved MicroED grid preparation using mix-and-inject gas dynamic virtual nozzles

Recent progress in gas dynamic virtual nozzle (GDVN) technologies in combination with high-brilliance synchrotron and X-ray free-electron lasers (XFELs) has allowed the visualization of protein dynamics in crystallo by mixing macromolecular protein crystals with a substrate using tunable mixing times on the order of milliseconds to seconds prior to serial X-ray diffraction data collection. This has become the method of choice for high-resolution structure determination of intermediate states. However, such experiments require large counts of crystals of proper sizes for high-resolution data collection, and premium beam times for screening efforts. Cryogenic microcrystal electron diffraction (MicroED) represents a complementary technique that may be a more accessible avenue for time-resolved nanocrystallography compared with serial X-ray diffraction experiments. MicroED can produce full diffraction datasets from just a few submicrometre-thick crystals, and the approach is more readily accessible, requiring standard cryogenic transmission electron microscopy (TEM) equipment available at many universities and institutes. Cryogenic MicroED, like other forms of cryo-EM, begins with rapidly freezing biological material on electron microscopy grids. In the case of MicroED, micro- to nano-crystals (<500 nm thick) are deposited onto electron microscopy grids and plunge-frozen for subsequent electron diffraction data collection. Here, we have incorporated GDVN technology developed originally for XFEL experiments into the freezing process as a first step towards time-resolved studies. We describe the limited deposition efficiency of the model MicroED protein proteinase K on TEM grids using GDVNs, preceding sample vitrification and successful MicroED data collection. We discuss both the initial results from such experiments and the methodological challenges in developing this approach into a reliable workflow for millisecond-to-second time-resolved structural studies of macromolecules. Our results promise a strategy to deposit crystals on grids using GDVNs and determine high-resolution structures by MicroED, constituting a first step towards development of time-resolved MicroED experiments.

MicroED↗

Automated, reliable, and efficient continental-scale replication of 7.3 petabytes of computational simulation data: A case study

We report on our experiences replicating 7.3 petabytes (PB) of Earth System Grid Federation (ESGF) computational simulation data from Lawrence Livermore National Laboratory (LLNL) in California to Argonne National Laboratory (ANL) in Illinois and Oak Ridge National Laboratory (ORNL) in Tennessee—a task motivated by a need for increased reliability, capacity, and performance. This task presented significant challenges: the need to move 29 million files twice under time pressure from aging storage hardware; a source file system bottleneck limiting throughput to 1.5 GB/s; frequent site maintenance windows; and the need for complete reliability at scale. We addressed these challenges using a simple replication tool that invoked Globus to transfer large bundles of files while tracking progress in a database, dynamically rerouting transfers to work around maintenance periods and file system limitations. Under the covers, Globus organized transfers to make efficient use of the high-speed Energy Sciences network (ESnet) and the data transfer nodes deployed at participating sites, and also addressed security, integrity checking, and recovery from a variety of transient failures. This success demonstrates the considerable benefits that can accrue from the adoption of performant data replication infrastructure. The replication tool is available at https://github.com/esgf2-us/data-replication-tools.

Globus↗

Hydropower Flexibility and Environmental Tradeoffs Analysis

The importance of hydropower increases as the power grid evolves with the higher variable renewable contribution. As conventional thermal power plants are retired, the importance of hydropower contribution increases to balance the variability of solar and wind generation. However, reservoir water resources are constrained by multiple constraints, and variability of water inflow to the reservoirs creates limitations to dam water releases for power grid needs. Coordinating multiple tools, including water resources, ecological, and technical and economic power grid modeling, informs dam water releases. The case study, the Columbia River Basin multipurpose reservoir project, is operated for hydropower production and many other purposes considering the aquatic habitat of the river basin. Specifically, the river basin fish population is a vital element for the tribal community of the river basin. We integrated a production cost model, a water resource model, and decades of tribal knowledge to analyze the fish-friendly way of operating Columbia hydropower scheduling and grid impacts. We measure power grid impacts for various water resources planning scenarios in terms of total system operating cost, system reliability indicators, changes in wind and solar generation and curtailments, local marginal prices, and revenue for hydropower producers. The study results inform reservoir operating rules decisions from hydropower power producers, system operators, other water users, tribes, environmentalists, and other stakeholders.

Columbia River↗

Power Lane County Electric Grid Handbook

In 2024, Lane Couty was selected to participate in the U.S. Department of Energy’s Energy to Community program. Through the program, National Laboratory researchers from Lawrence Berkeley National Laboratory, Pacific Northwest National Laboratory, and the National Laboratory of the Rockies provide three years of technical assistance to Lane County and their project partners: the Center for Rural Livelihoods, Springfield Utility Board, and Emerald People’s Utility District. The project, named Power Lane County, aims to improve local electric system affordability, reliability and resilience in the face of natural hazards and potentially rising loads. The Power Lane County Electric Grid Handbook establishes a foundational understanding of the energy landscape and electric grid in Lane County to inform community engagement, education, and analysis in future project phases. This document synthesizes public data and utility and stakeholder engagement, including utility interviews to give the reader a comprehensive view of the challenges facing Lane County's electric system and the opportunities to address them

Electricity↗

A Graph-Net with Node Embeddings to Detect False Data Injection Attacks in Photovoltaic Systems

Distributed energy resources (DER) contribute to the operational stability of the larger power grid both at utility-scale as well as commercial and residential scales in aggregated forms. These DER in-turn are susceptible to increasing cyber threats. An adversary can plug into the same local network that a field photovoltaic (PV) system uses to interconnect its data loggers and inverters and manipulate certain measurements collected from the network or trick existing irradiance and inverter readings through false data injection attacks (FDIA). Control routines that rely on these measurements can propagate the false data, impacting critical decisions that result in a suboptimal operation or even cause intentional harm leading to inverter-tripping or unscheduled loads that need to be shed. To detect FDIA in PV systems, the paper introduces an attention-based graph neural network with node embeddings and applied it to a simple prototypical DC-coupled microgrid with PV, energy storage, and load. The algorithm shows a detection accuracy of up to 98.95%. The proposed FDIA detection technique will provide micro-grid operators with an effective method to safeguard their systems, guaranteeing the secure and reliable operation.

Parvez, Imtiaz [Utah Valley University]↗

Connected Residential Communities with Enhanced Resiliency and both Customer and Utility Attributes (Final Technical Report)

This report is a compilation of information from Quarter Progress Reports submitted to the Department of Energy’s Office of Energy Efficiency Building Technologies Office (BTO) by SunPower Corporation. The report has been uploaded to OSTI by DOE as a substitute for the required Final Technical Report which was never received from the project recipient.

14 SOLAR ENERGY↗

Comprehensive Life Cycle Analysis of Methanol Production and Methanol-to-Diesel Conversion

Methanol is a strategic chemical and intermediate in the manufacture of synthetic diesel, due to its versatility, diesel’s compatibility with existing infrastructure, and their role in industrial and transport applications. Conventional production methods for methanol, primarily steam methane reforming (SMR), rely on natural gas and are subject to the price variability due to market conditions and geopolitical events. They are also associated with greenhouse gas (GHG) emissions. Methanol and synthetic diesel production could be integrated with nuclear energy to stabilize fuel prices and insulate pricing from outside geopolitical events due to the relative stability of nuclear fuel as compared to natural gas. This could lead to increased transportation fuel security, reliability and resilience. An added benefit is the abatement of emissions when substituting nuclear energy for conventional energy from natural gas. This report presents a comprehensive life cycle analysis(LCA) framework which was developed to evaluate the GHG emissions reduction potential associated with nuclear integrated methanol production, methanol-to-diesel upgrading, and end-use combustion. Gate-to-gate methanol production and cradle-to-grave emissions were evaluated in, starting with a business-as-usual (BAU) SMR-based methanol plant, and then considering stepwise nuclear integration. Methanol-to-diesel (MTD) conversion was evaluated accounting for nuclear energy integration and hydrogen production via high-temperature steam electrolysis (HTSE) using electricity either from the grid or from a dedicated nuclear power system. This multi-step process diverts stable and reliable nuclear energy into the transportation sector by upgrading low energy dense natural gas into liquid fuels fully compatible with existing infrastructure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Tangible Solutions for Grid Operation Upgrade

Many countries worldwide are setting clean energy targets to decarbonize the energy sector and add higher wind and solar capacities. Given their distributed nature, variable renewable energy (VRE) assets can have unique grid integration considerations, and require grid operation practices to be modernized. When transitioning to higher renewable energy levels, many system operators configure a dedicated renewable energy desk to manage renewable energy resource operation in the system control center. Further, system operation planning is conducted with VRE and load forecasting to enable reliable real-time system operation. NREL has partnered with many system operators in the region to identify appropriate technology and grid modernization solutions. NREL and partners from system operators in the region will present on the challenges and some solutions that have been applied and share best practices such as energy management system upgrades, VRE forecasting framework, grid flexibility improvements, and staff training.

emerging economies↗

Assessment of Technoeconomic Opportunities in Automation for Nuclear Microreactors

Achieving full decarbonization of all economic sectors remains a challenge, especially in niche markets. For example, remote communities and industrial or mining activities detached from the main electric grid heavily rely on fossil fuels, similar to urban and industrial microgrids with combined heat and power needs. A combination of renewables and energy storage is often not suitable due to cost, reliability, intermittency, and large storage requirements. Small nuclear reactors with a flexible purpose could serve these applications. Microreactors (MR) are a class of reactors that are compact, factory manufactured, transportable, and self-regulating. Typically, they generate much less power than their large reactor counterparts. The main advantages of microreactors include the versatile nature of the energy produced, the reliability of supply, and freedom from having to transport and store large quantities of fuels on-site, coupled with the absence of dependence on an electrical grid. A strong business case is needed to move from the microreactor prototype to the commercialization phase. In fact, fossil fuels are still relatively inexpensive, and in the near term, carbon credits will be available to virtually compensate for emissions. For microreactors, one of the main costs in operation and maintenance (O&M) is their staffing levels. In this study, we investigate how to optimize the number (and thus the cost) of workers, moving from a traditional, fully manned, on-site personnel approach to an unmanned, remote personnel approach. We examine four different staffing models that can be implemented as the technology matures and evolves. We estimate the staffing needs of each model and build a business case to justify the substitution of on-site personnel with adequate technologies. To do so, we propose a cost model to quantify potential cost reductions from automating O&M activities. The model accounts for both the reduction in cost derived from the reduced number of full-time-equivalent (FTE) employees and the increase in cost derived from the need to buy new control hardware as needed. Applying the cost model that we created to different scenarios, an on-site O&M cost reduction exceeding 80% can be expected. Additionally, we found that it is more impactful to focus on automating routine O&M tasks rather than attempting to automate transient management (shutdowns, restarts, monitoring condition deviations). In fact, transients typically account for less than 1% of the total FTE time spent on the reactors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Adoption of AI in the Utility T&D Sector: Use Cases, Consequence, Assessment and Benefits

Digital transformation and utilization of artificial intelligence (AI) in the electric grid are fundamentally changing the industry’s approach to common problems and enabling a broader paradigm shift in grid planning and operations. The change in approach is circularly both enabling and driving modernization, with load growth and reliable management of data center and AI infrastructure shifting away from planning approaches with relatively predictable behaviors and toward a mix of consumer and industrial choices that surpass human cognitive abilities to process. This movement has potential to condition humans to not understand the system on which the AI depends, while requiring it for development of the necessary infrastructure. Approaches which would address most likely grid conditions and events, such as faults, aging of equipment, and weather, now must also account for large loads which shift not based upon weather or time of day, but the computational load. Quantifying computational load is independent of the traditional grid forecasting variables, where a data center’s aggregate load is determined by user and AI system behavior and decoupled from normal grid planning and operations. AI is both the cause and solution for these challenges, with new grid planning tools integrating massive amounts of decisions into frameworks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A census of fish passage facilities at US hydropower developments across the conterminous United States

Hydropower provides reliable and secure electricity and contributes significantly to the flexibility and stability of the US electricity grid. Hydropower dams generally are aquatic barriers and hazards to migratory fish in rivers. Fish passage facilities mitigate risks from hydropower to migratory fish, but information on these facilities is incomplete for the conterminous United States (CONUS). Here, we present the first CONUS-scale dataset of fish passage facilities at US hydropower developments in over 30 years. The existence of fish passage facilities (presence or absence) was specified for 1909 hydropower features, 390 of which had at least one facility. Most features had a single passage facility that provided passage in only one direction, with downstream being more common than upstream passage. Bypasses and ladders accounted for 60 % of the fish passage facility types. While we documented 659 fish passage facilities across CONUS, facilities were most common in the New England, Pacific Northwest, Mid-Atlantic, and Great Lakes regions. In general, fish passage facilities were more common at features that were closer to the ocean, at lower elevations, and at shorter dams, but not related to installed electrical generation capacity. Hydrologic sub-basins containing salmonids also contained the largest number of hydropower features, but the proportion of features with passage was generally higher in sub-basins containing multiple migratory taxa. This census provides valuable information on existing fish passage mitigation and is a benchmark to gauge progress toward a modernized hydropower fleet that provides affordable, reliable energy while protecting fishery resources and river ecosystems.

13 HYDRO ENERGY↗

Alternating Direction Decomposition with Strong Bounding and Convexification (ADDSBC) for Solving Security Constrained AC Unit Commitment Problems

This project aims to develop efficient and robust computational methods for solving the security-constrained unit commitment and alternating current optimal power flow problem (SC-UC-ACOPF). The SC-UC-ACOPF problem is at the center of the short-term operation of the U.S. Power Grid. It is solved every week, every day, and every 10 minutes to plan for the optimal action of electricity generation and consumption by minimizing the generation cost and maintaining power system reliability against potential disruptions of equipment failures. In mathematical terms, SC-UC-ACOPF is a challenging large-scale mixed-integer nonlinear optimization model. This means that the decisions involve both discrete variables, e.g. the turning on and off of generators and switching of transmission lines and transformers, and continuous decisions, e.g. the amount of energy generated by each generator and the power flows in the power grid. The physics of the power flow is described by nonlinear equations involving real and reactive power and bus voltages. Another key feature is the large number of contingencies, i.e. the system needs to stay reliable in face of failure of any one equipment, such as transmission lines and generators. The U.S. power grids are extremely complicated and large scale with more than 5,000 generators, 50,000 buses, and 100,000 high-voltage transmission lines, making the SC-UC-ACOPF a very large-scale computation challenge. The research developed in this project aims to solve the SC-UC-ACOPF problems in the three timescales, i.e. weekly, daily, and every 10-min. The proposed computational methods are built on a principled algorithmic approach of decomposition and penalization. More specifically, the algorithm develops spatial and temporal decomposition by exploiting the strong temporal coupling and weak spatial coupling of the UC problem and the complementary feature, i.e. weak temporal coupling and strong spatial coupling of the ACOPF problem. The algorithm also leverages recent progresses in strong convex relaxation of ACOPF. A unique feature of the proposed approach is that it generates a valid, global upper bound on the optimal maximum profit. In this way, a global optimality gap is available to measure the quality of the solution. To further speed up computation, the research team has developed a plethora of effective heuristics to strengthen the iterative penalty-based decomposition framework. For instance, a heuristic is developed to construct inner approximations of the time coupling constraints within the time decoupled problems. Contingencies are pre-screened and low-rank matrix computation is exploited to find the almost unique solution to each contingency. A novel heuristic for line switching is proposed and tested with positive impacts on instances where line switching is beneficial. Taking a systematic approach and carefully handling every detail of the problem pays off. The TIM-GO’s performance throughout the trials and the final event was stellar. TIM-GO garnered the second highest total prize money and is ranked in the top three positions across all categories of comparison.

97 MATHEMATICS AND COMPUTING↗

A Novel Protection Scheme for Unbalanced Faults in Inverter Dominated Networks: A Computationally Efficient Algorithm for Entry-Level Relays

Microgrids are now a common practice in distribution systems to increase resilience and reliability. However, microgrid protection remains a critical challenge, considering its requirement to operate in both grid connected and islanded, and the variability in fault characteristics under each mode of operation. This paper presents unbalanced power (S unb ) based fault detection algorithm, which considers local voltage and current unbalances to determine faults in the system. S unb is a computationally efficient fault detection algorithm that is suitable for implementation in the programmable logic of entry level protective relays. In addition, the difference in current and voltage unbalance (D n ) is used to determine the fault type. The proposed method demonstrates high sensitivity and selectivity for line-to-ground (LG), line-to-line (LL), and double line-to-ground (LLG) faults, representing the most common faults in distribution systems. It also allows relay coordination with upstream and downstream protection devices in both island and grid connected operation, while preserving grading margins. The same pickup and time multiplier settings of a particular relay for both modes of operation eliminates the need for adaptive settings, which rely on communication networks. Validation was performed with a hardware-in-the-loop (HIL) setup using Typhoon HIL real time simulator interfaced with three entry-level, SEL 751 relays. Results confirmed the algorithm’s ability to discriminate fault conditions, and determine the fault type under both operating modes, maintain fast detection times, and ensure proper protection coordination.

fault classification↗

Calculating Critical Inertia of a Power System

The increasing integration of renewable energy sources in modern power systems has led to a decline in system inertia, raising concerns about frequency stability following large disturbances. Determining critical inertia is essential to prevent excessive frequency decline and ensure grid stability. This paper evaluates four different methods for calculating critical inertia, using the Electric Reliability Council of Texas (ERCOT) system as a test case. The results highlight the importance of employing multiple methodologies to capture the full spectrum of inertia requirements.

Hakim sneha, Fariha [University of Tennessee, Knox↗

Risk-controlled Expansion Planning with Distributed Resources (REPAIR) v1.0

The Risk-controlled Expansion Planning with Distributed Resources (REPAIR) is an innovative tool to support decisions around utility grid planning to prevent and mitigate the impact of outages caused by routine equipment failures (reliability) or by extreme events (resilience), such as storms, earthquakes or wildfires that long term interruption of service. REPAIR is a risk-based optimization and decision-making model allowing informed and transparent "cost vs risk" decisions regarding infrastructural planning of electric utilities. The model considers long-term resilience and reliability planning strategies that rely on traditional infrastructure upgrade (e.g. circuit hardening, reinforcement, new substations, etc.) or new investment alternatives, such as DERs.

Heleno, Miguel [Lawrence Berkeley National Laborat↗

Characterizing Seasonal Variation of the Atmospheric Mixing Layer Height Using Machine Learning Approaches

As machine learning becomes more integrated into atmospheric science, XGBoost has gained popularity for its ability to assess the relative contributions of influencing factors in the atmospheric boundary layer height. To examine how these factors vary across seasons, a seasonal analysis is necessary. However, dividing data by season reduces the sample size, which can affect result reliability and complicate factor comparisons. To address these challenges, this study replaces default parameters with grid search optimization and incorporates cross-validation to mitigate dataset limitations. Using XGBoost with four years of data from the atmospheric radiation measurement (ARM) (Southern Great Plains (SGP) C1 site, cross-validation stabilizes correlation coefficient fluctuations from 0.3 to within 0.1. With optimized parameters, the R value can reach 0.81. Analysis of the C1 site reveals that the relative importance of different factors changes across seasons. Lower tropospheric stability (LTS, ~0.53) is the dominant factor at C1 throughout the year. However, during DJF, latent heat flux (LHF, 0.44) surpasses LTS (0.22). In SON, LTS (0.58) becomes more influential than LHF (0.18). Further comparisons among the four long-term SGP sites (C1, E32, E37, and E39) show seasonal variations in relative importance. Notably, during JJA, the differences in the relative importance of the three factors across all sites are lower than in other seasons. This suggests that boundary layer development in the summer is not dominated by a single factor, reflecting a more intricate process likely influenced by seasonal conditions such as enhanced convective activity, higher temperatures, and humidity, which collectively contribute to a balanced distribution of parameter impacts. Furthermore, the relative importance of LTS gradually increases from morning to noon, indicating that LTS becomes more significant as the boundary layer approaches its maximum height. Consequently, the LTS in the early morning in autumn exhibits greater relative importance compared to other seasons. This reflects a faster development of the mixing layer height (MLH) in autumn, suggesting that it is easier to retrieve the MLH from the previous day during this period. The findings enhance understanding of boundary layer evolution and contribute to improved boundary layer parameterization.

54 ENVIRONMENTAL SCIENCES↗

Building a Trusted Roaming Hub [Slides]

The Trusted Roaming Hub is a U.S. Department of Energy-backed initiative led by the National Laboratory of the Rockies (NLR) to address one of the most persistent challenges in electric vehicle (EV) charging: fragmented roaming, inconsistent interoperability, and insufficient digital trust across charging networks. As EV adoption accelerates and charging infrastructure scales nationwide, today's many-to-many integration model between eMobility Service Providers (eMSPs) and Charge Point Operators (CPOs) has become increasingly brittle, costly, and difficult to secure. The Trusted Roaming Hub introduces a neutral, cybersecurity-forward "switchboard" architecture that enables standardized, secure, and scalable roaming interactions across the EV charging ecosystem. Rather than replacing existing networks or commercial relationships, the hub acts as a trusted intermediary that enforces consistent identity, authentication, authorization, and routing across participants improving reliability for drivers, lowering integration burden for industry, and creating a foundation for future grid-interactive charging services. This read-ahead provides an overview of the problem the hub is designed to solve, the core functional and security concepts behind the architecture, the value proposition to key stakeholders, and the near-term trajectory of the work.

33 ADVANCED PROPULSION SYSTEMS↗