First hydrogen operation of NIO1: Characterization of the source plasma by means of an optical emission spectroscopy diagnostic

NIO1 (Negative Ion Optimization 1) is a compact and flexible radio frequency H{sup −} ion source, developed by Consorzio RFX and INFN-LNL. The aim of the experimentation on NIO1 is the optimization of both the production of negative ions and their extraction and beam optics. In the initial phase of its commissioning, NIO1 was operated with nitrogen, but now the source is regularly operated also with hydrogen. To evaluate the source performances, an optical emission spectroscopy diagnostic was installed. The system includes a low resolution spectrometer in the spectral range of 300-850 nm and a high resolution (50 pm) one, to study, respectively, the atomic and the molecular emissions in the visible range. The spectroscopic data have been interpreted also by means of a collisional-radiative model developed at IPP Garching. Besides the diagnostic hardware and the data analysis methods, the paper presents the first plasma measurements across a transition to the full H mode, in a hydrogen discharge. The characteristic signatures of this transition in the plasma parameters are described, in particular, the sudden increase of the light emitted from the plasma above a certain power threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CW/Pulsed H{sup −} ion beam generation with PKU Cs-free 2.45 GHz microwave driven ion source

Circular accelerators used for positron emission tomography (PET, i.e. accelerator used for make radio isotopes) need several mA of CW H- ion beam for their routine operation. Other facilities, like Space Radio-Environment Simulate Assembly (SPRESA), require less than 10 mA pulsed mode H{sup −} beam. Caesium free negative hydrogen ion source is a good choice for those facilities because of its compact structure, easy operation and low cost. Up to now, there is no H{sup −} source able to produce very intense H{sup −} beams with important variation of the duty factor{sup [1]}. Recently, a new version of 2.45 GHz microwave H{sup −} ion source was designed at PKU, based on lessons learnt from the previous one. This non cesiated source is very compact thanks to its permanent magnet configuration. Special attention was paid on the design of the discharge chamber structure, electron dumping and extraction system. Source test to produce H{sup −} ion beams in pulsed and CW mode was carried out on PKU ion source test bench. In CW mode, a 10.8 mA/30keV H{sup −} beam with rms emittance about 0.16 π·mm·mrad has been obtained with only 500 W rf power. The power efficiency reaches 21 mA/kW. In pulsed mode with duty factor of 10% (100Hz/1ms), this compact source can easily deliver 20 mA H{sup −} ion beam at 35 keV with rms emittance about 0.2 π·mm·mrad when RF power is set at 2.2 kW (peak power). Several hour successive running operation in both modes and totaling more than 200 hours proves its high quality. The outside dimension of this new H{sup −} source body is ϕ116 mm × 124 mm, and the entire H{sup −} source infrastructure, including rf matching section, plasma chamber and extraction system, is ϕ310 × 180 mm. The high voltage region is limited with in a ϕ310 mm × 230 mm diagram. Details are given in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel, Low-Cost, Light-Weight High Efficiency (H*10 Capable) Neutron Detector-Dosimeter

The goal of this project was to design, develop and validate a novel, spectroscopy enabled H*(10) neutron dosimetry system based on the tensioned metastable fluid detector (TMFD) sensor technology. The project team consisted of staff from Oak Ridge National Laboratory (ORNL), Purdue University (PU) and Sagamore Adams Laboratories, LLC (SAL). PU-SAL staff were tasked with the design, development, construction and testing of the H*TMFD hardware and software, along with developing the control and data acquisition software for comparison of predictions from H*TMFD against a commonly accepted and widely used industry standard system; for this project, the Li-I detector coupled to bonner spheres (LiI-BSS) system manufactured by Ludlum, Inc. was utilized as the reference (“gold”) standard – similar in terms of neutron spectroscopy enablement to another industry recognized, albeit, significantly higher cost (est. $300K) system referred to as “ROSPEC” (from BTI, Inc., which was not available for this project). ORNL staff were tasked with providing field-relevant guidance, apparatus and facilities for acquiring data against calibrated neutron sources, and comparing results of H*TMFD against LiI-BSS system predictions in a series of blind-tests conducted at ORNL. Over the course of 12 months, the PU-SAL-ORNL staff successfully accomplished the proposed technical and administrative tasks, inclusive of engaging in outreach to potential users of this technology in the DOE-wide infrastructure. The proposed tasks were successfully accomplished in timely manner; the follow-up type tasks pertaining to SBIR type Phases 2-3 were discussed and are initiated, inclusive of filing for intellectual property (IP) disclosures and possible patent filings by PU’s Office of Technology Commercialization (OTC). Two H*TMFD system architectures (see Exhibits 1 & 2 in the report) were developed and constructed for hand-portability by health-physicists (HPs) – the HP-H*TMFD, and the H*TMFD system which consists of a side-by-side mounted array of 4 TMFDs of 3 different sizes in sensitive volume (including one with borated fluid) that now simultaneously enables neutron energy spectroscopy: single bin for < 0.1 MeV, and 152 energy bins in the 0.1-15.2 MeV range; H*(10) dosimetry from ~5 μRem/h towards 10 R/h ranges. Several experiments were conducted using neutron sources in various configurations (shielded and unshielded). In direct comparison against the LiI-BSS industry standard (acquiring data for 26h each source), the H*TMFD system (acquiring data for ~6h for each source) offered H*(10) dose predictions for the most part accurate to within +/-10% for dose rates in the 100-300 μRem/h range. The LiI-BSS was impractical to use under ultra-low (~10 μRem/h) dose rate space, as also another metering device used at ORNL (Ludlum 4241L non-spectroscopy enabled) for which the lower limit is set by the manufacturer at 100 μRem/h. The enablement for efficient use in timely manner at the 10 μRem/h levels is deemed to be a strong enabling factor for H*TMFD for use in the DOE-nuclear laboratory arena. In terms of weight, the HP-H*TMFD weighs under ~5-7 lb.; the H*TMFD system weighs ~35-lb. As such, it is ~1/4 the weight of an LiI-BSS system weighing ~120 lb (LiI detector with 6 bonner spheres) and, ~1/2 the weight of ROSPEC. As a result of this activity, two involved post-doctoral student staff have now transitioned their knowledge and experiences to DOE’s Pacific Northwest National Laboratory (PNNL). A PU graduate student has also benefited from this project work which formed a principal basis for his Ph.D. dissertation work (in progress).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPECTROSCOPIC FOLLOW-UP OF X-RAY SOURCES IN THE ChaMPlane SURVEY: IDENTIFICATION OF A NEW CATACLYSMIC VARIABLE

We present a multi-object optical spectroscopy follow-up study of X-ray sources in a field along the Galactic plane (l = 327.{sup 0}42, b = 2.{sup 0}26) which is part of the Chandra Multi-wavelength Plane survey (ChaMPlane). We obtained spectra for 46 stars, including 15 likely counterparts to X-ray sources, and sources showing an H{alpha} color excess. This has led to the identification of a new cataclysmic variable (CV), CXOPS J154305.5-522709, also named ChaMPlane Bright Source 7 (CBS 7), and we identified eight X-ray sources in the field as active late-type stars. CBS 7 was previously studied in X-rays and showed a hard spectrum and two periods: 1.22 {+-} 0.08 hr and 2.43 {+-} 0.26 hr. We present here clear evidence that the source is a CV through the detection of H, He I, and He II emission lines in its optical spectrum. The hard X-ray spectrum and the presence of the He II {lambda}4686 in emission with a large equivalent width suggest a magnetic CV. The near-infrared counterpart is significantly variable, and we found a period consistent with the longest X-ray period at 2.39 {+-} 0.05 hr but not the shortest X-ray period. If this period is the orbital period, this would place the system in the CV period gap. The possible orbital period suggests a dM4 {+-} 1 companion star. The distance is then estimated to be {approx}1 kpc. The system could be a relatively hard and X-ray luminous polar or an intermediate polar, possibly nearly synchronous.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimization of plasma parameters with magnetic filter field and pressure to maximize H{sup −} ion density in a negative hydrogen ion source

Transverse magnetic filter field as well as operating pressure is considered to be an important control knob to enhance negative hydrogen ion production via plasma parameter optimization in volume-produced negative hydrogen ion sources. Stronger filter field to reduce electron temperature sufficiently in the extraction region is favorable, but generally known to be limited by electron density drop near the extraction region. In this study, unexpected electron density increase instead of density drop is observed in front of the extraction region when the applied transverse filter field increases monotonically toward the extraction aperture. Measurements of plasma parameters with a movable Langmuir probe indicate that the increased electron density may be caused by low energy electron accumulation in the filter region decreasing perpendicular diffusion coefficients across the increasing filter field. Negative hydrogen ion populations are estimated from the measured profiles of electron temperatures and densities and confirmed to be consistent with laser photo-detachment measurements of the H{sup −} populations for various filter field strengths and pressures. Enhanced H{sup −} population near the extraction region due to the increased low energy electrons in the filter region may be utilized to increase negative hydrogen beam currents by moving the extraction position accordingly. This new finding can be used to design efficient H{sup −} sources with an optimal filtering system by maximizing high energy electron filtering while keeping low energy electrons available in the extraction region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

B{sub 18}H{sub 22} Implantation for the Source-Drain Extension in 45 nm-node PMOSFETs and Beyond

We investigated the application properties of cluster implantation for MSA processing. We successfully replaced BF{sub 2} with B{sub 18}H{sub 22} to SDE implantation in pMOSFETs with the activation processing of MSA and spike-RTA. In the activation processing with only MSA, we found from blank wafer that B{sub 18}H{sub 22} implant is more advantageous from the viewpoint of R{sub s}, X{sub j} and leakage current, compared to B, BF{sub 2} and B with Ge-PAI00.

36 MATERIALS SCIENCE↗

AN IN-DEPTH VIEW OF THE MID-INFRARED PROPERTIES OF POINT SOURCES AND THE DIFFUSE ISM IN THE SMC GIANT H II REGION, N66

The focus of this work is to study mid-infrared point sources and the diffuse interstellar medium (ISM) in the low-metallicity ({approx}0.2 Z{sub Sun }) giant H II region N66 in order to determine properties that may shed light on star formation in these conditions. Using the Spitzer Space Telescope's Infrared Spectrograph, we study polycyclic aromatic hydrocarbon (PAH), dust continuum, silicate, and ionic line emission from 14 targeted infrared point sources as well as spectra of the diffuse ISM that is representative of both the photodissociation regions (PDRs) and the H II regions. Among the point source spectra, we spectroscopically confirm that the brightest mid-infrared point source is a massive embedded young stellar object, we detect silicates in emission associated with two young stellar clusters, and we see spectral features of a known B[e] star that are commonly associated with Herbig Be stars. In the diffuse ISM, we provide additional evidence that the very small grain population is being photodestroyed in the hard radiation field. The 11.3 {mu}m PAH complex emission exhibits an unexplained centroid shift in both the point source and ISM spectra that should be investigated at higher signal-to-noise and resolution. Unlike studies of other regions, the 6.2 {mu}m and 7.7 {mu}m band fluxes are decoupled; the data points cover a large range of I{sub 7.7}/I{sub 11.3} PAH ratio values within a narrow band of I{sub 6.2}/I{sub 11.3} ratio values. Furthermore, there is a spread in PAH ionization, being more neutral in the dense PDR where the radiation field is relatively soft, but ionized in the diffuse ISM/PDR. By contrast, the PAH size distribution appears to be independent of local ionization state. Important to unresolved studies of extragalactic low-metallicity star-forming regions, we find that emission from the infrared-bright point sources accounts for only 20%-35% of the PAH emission from the entire region. These results make a comparative data set to other star-forming regions with similarly hard and strong radiation fields.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron cyclotron resonance heating by magnetic filter field in a negative hydrogen ion source

The influence of magnetic filter field on plasma properties in the heating region has been investigated in a planar-type inductively coupled radio-frequency (RF) H{sup −} ion source. Besides filtering high energy electrons near the extraction region, the magnetic filter field is clearly observed to increase the electron temperature in the heating region at low pressure discharge. With increasing the operating pressure, enhancement of electron temperature in the heating region is reduced. The possibility of electron cyclotron resonance (ECR) heating in the heating region due to stray magnetic field generated by a filter magnet located at the extraction region is examined. It is found that ECR heating by RF wave field in the discharge region, where the strength of an axial magnetic field is approximately ∼4.8 G, can effectively heat low energy electrons. Depletion of low energy electrons in the electron energy distribution function measured at the heating region supports the occurrence of ECR heating. The present study suggests that addition of axial magnetic field as small as several G by an external electromagnet or permanent magnets can greatly increase the generation of highly ro-vibrationally excited hydrogen molecules in the heating region, thus improving the performance of H{sup −} ion generation in volume-produced negative hydrogen ion sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Test Stand for Ion Sources of Ultimate Reliability

The rationale behind the ITUR project is to perform a comparison between different kinds of H{sup -} ion sources using the same beam diagnostics setup. In particular, a direct comparison will be made in terms of the emittance characteristics of Penning Type sources such as those currently in use in the injector for the ISIS (UK) Pulsed Neutron Source and those of volumetric type such as that driving the injector for the ORNL Spallation Neutron Source (TN, U.S.A.). The endeavour here pursued is thus to build an Ion Source Test Stand where virtually any type of source can be tested and its features measured and, thus compared to the results of other sources under the same gauge. It would be possible then to establish a common ground for effectively comparing different ion sources. The long term objectives are thus to contribute towards building compact sources of minimum emittance, maximum performance, high reliability-availability, high percentage of desired particle production, stability and high brightness. The project consortium is lead by Tekniker-IK4 research centre and partners are companies Elytt Energy and Jema Group. The technical viability is guaranteed by the collaboration between the project consortium and several scientific institutions, such the CSIC (Spain), the University of the Basque Country (Spain), ISIS (STFC-UK), SNS (ORNL-USA) and CEA in Saclay (France)

43 PARTICLE ACCELERATORS↗