Search NASA⌕ Search

SEARCH · Search NASA

Results for “HIGH PASS FILTERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Software for Generating Strip Maps from SAR Data

Jurassicprok is a computer program that generates strip-map digital elevation models and other data products from raw data acquired by an airborne synthetic-aperture radar (SAR) system. This software can process data from a variety of airborne SAR systems but is designed especially for the GeoSAR system, which is a dual-frequency (P- and X-band), single-pass interferometric SAR system for measuring elevation both at the bare ground surface and top of the vegetation canopy. Jurassicprok is a modified version of software developed previously for airborne-interferometric- SAR applications. The modifications were made to accommodate P-band interferometric processing, remove approximations that are not generally valid, and reduce processor-induced mapping errors to the centimeter level. Major additions and other improvements over the prior software include the following: a) A new, highly efficient multi-stage-modified wave-domain processing algorithm for accurately motion compensating ultra-wideband data; b) Adaptive regridding algorithms based on estimated noise and actual measured topography to reduce noise while maintaining spatial resolution; c) Exact expressions for height determination from interferogram data; d) Fully calibrated volumetric correlation data based on rigorous removal of geometric and signal-to-noise decorrelation terms; e) Strip range-Doppler image output in user-specified Doppler coordinates; f) An improved phase-unwrapping and absolute-phase-determination algorithm; g) A more flexible user interface with many additional processing options; h) Increased interferogram filtering options; and i) Ability to use disk space instead of random- access memory for some processing steps.

Hensley, Scott↗

Machine learning pipeline for denoising low signal-to-noise ratio and out-of-distribution transmission electron microscopy datasets

High-resolution transmission electron microscopy (HRTEM) is crucial for observing material’s structural and morphological evolution at Angstrom scales, but the electron beam can alter these processes. Devices such as CMOS-based direct-electron detectors operating in electron-counting mode can be utilized to substantially reduce the electron dosage. However, the resulting images often lead to a low signal-to-noise ratio, which requires frame integration that sacrifices temporal resolution. Several machine learning (ML) models have been recently developed to successfully denoise HRTEM images. Yet, these models are often computationally expensive, and their inference speeds on GPUs are outpaced by the imaging speed of advanced detectors, precluding in situ analysis. Furthermore, the performance of these denoising models on datasets with imaging conditions that deviate from the training datasets has not been evaluated. To mitigate these gaps, we propose a new self-supervised ML denoising pipeline specifically designed for time-series HRTEM images. This pipeline integrates a blind-spot convolution neural network with pre-processing and post-processing steps, including drift correction and low-pass filtering. Results demonstrate that our model outperforms various other ML and non-ML denoising methods in noise reduction and contrast enhancement, leading to improved visual clarity of atomic features. Additionally, the model is drastically faster than U-Net-based ML models and demonstrates excellent out-of-distribution generalization. The model’s computational inference speed is in the order of milliseconds per image, rendering it suitable for application in in-situ HRTEM experiments.

36 MATERIALS SCIENCE↗

Generating Ka-Band Signals Using an X-Band Vector Modulator

A breadboard version of a transmitter for radio communication at a carrier frequency of 32 GHz (which is in the Ka band) utilizes a vector modulator operating at a carrier frequency of 8 GHz (the low end of the X band) to generate any of a number of advanced modulations that could include amplitude and/or phase modulation components. The 8-GHz modulated signal is mixed with a 24-GHz signal generated by an upconverter to obtain the desired 32-GHz modulated output. The transmitter is being developed as a prototype of downlink transmitters for transmission of data from spacecraft to Earth at high rates (>100 Mb/s). The transmitter design could also be adapted to terrestrial and Earth/satellite communication links. The advanced modulations (which can include M-ary phase-shift keying (M-PSK), offset phase-shift keying (OPSK), and M-ary quadrature amplitude modulation (M-QAM). These modulations are needed because for a given amount of signal bandwidth, they enable transmission of data at rates greater than those of older, simpler modulation schemes. The transmitter architecture (see figure) was chosen not only to enable generation of the required modulations at 32 GHz but also to reduce the number of components needed to implement the transmitter. Instead of incorporating an 8-GHz signal source, the transmitter utilizes an 8-GHz signal generated by a voltage-controlled oscillator that is part of an X-band transponder with which the fully developed version of this transmitter would be used in the original intended spacecraft application. The oscillator power is divided onto two paths, one of which goes through the vector modulator, the other through amplifiers and a 3 frequency multiplier. Band-pass filters are included downstream of the frequency multiplier to suppress unwanted harmonics.

Smith, Scott↗

Large-aperture high-resolution X-ray collimator for the Solar Maximum Mission

A description is presented of a flight-qualified large-aperture 12 x 12-arcsec angular resolution multigrid X-ray collimator developed for the Solar Maximum Mission (SMM) flat crystal spectrometer. This collimator, designed for the 1.4-22.4-A wavelength range, utilizes an optical bench/metering structure to align and support prealigned grid subassemblies. The optical bench is a lightweight, rigid, and stable aluminum honeycomb structure. The grids are of a compound and bimetallic design, having 63.5-micron square holes on an 88.9-micron spacing in 8-micron thick gold, which is in turn supported by a 76-micron thick Invar grid having 600-micron square holes on a 739-micron spacing. The small apertures in the gold provide the 12-arcsec collimation with the Invar grids providing wide angle off-axis blocking out to an approximately 35 arcmin view angle. The collimator has seven individual channels, four of a 5.1- x 10-cm area and three of a 1.3- x 10-cm area. Laboratory measurements gave an average angular resolution of 12.5 arcsec FWHM with 0.259 transmission for the large-area channels and 12.0 arcsec and 0.200 transmission for the small-area channels. A thermal filter composed of two layers of approximately 1000-A thick aluminum prevents solar heating of the front collimator grids by absorbing longer wavelength radiation while passing most of the X radiation in the band of interest.

Nobles, R. A.↗

Improvement in Suppression of Pulsed Nd:YAG Laser Light With Iodine Absorption Cells for Filtered Rayleigh Scattering Measurements

Filtered Rayleigh scattering using iodine absorption cells is an effective technique for obtaining density, temperature, and velocity measurements in high speed confined flows. By tuning a single frequency laser to a strong iodine absorption line, stray scattered laser light can be greatly suppressed. For example, the minimum transmission predicted by an iodine absorption model calculation is less than 10(exp -5) at the 18788.44/cm line using a 200 mm absorption cell containing iodine vapor at 0.46 T. Measurements obtained by other researches using a CW Nd:YAG laser agree with the model calculations. However, measurements made by us and by others using Q-switched, injection-seeded, frequency doubled Nd:YAG lasers only show minimum transmission of about 3 x 10(exp -3). This greatly reduces the applicability of the filtered Rayleigh scattering technique using these lasers in experiments having large amounts of stray scattered laser light. The purposes of the present study are to characterize the spectrum of the excess light transmitted by the iodine cell and to make changes to the laser to reduce the transmitted laser light. Transmission data as a function of laser frequency for the iodine absorption line at 18788.44/cm are presented. A planar mirror Fabry-Perot interferometer was used to characterize the frequency spectrum of the light passed through the cell. Measurements taken with the laser tuned to the center of the iodine absorption line show the light transmitted through the iodine cell to have a component with a bandwidth of about 40 GHz. This is probably caused by other modes in the laser that exist in spite of the single frequency injection beam. A second broadband component was also observed, possibly caused by the laser flash lamps or by fluorescence. An intracavity etalon was installed in the laser oscillator cavity to suppress the 40 GHz component. Measurements taken with the etalon tuned to the injection frequency showed a reduction in the transmitted laser light. This improvement allows the iodine cell to block significantly more of the stray laser light in filtered Rayleigh scattering experiments. Examples are given of filtered Rayleigh scattering measurements showing the effect of the etalon on measurements taken in a Mach 3 flow in the NASA Lewis 4 inch by 10 inch supersonic wind tunnel.

Seasholtz, Richard G.↗

A Miniaturized Video System for Monitoring Drosophila Behavior

Long-term spaceflight may induce a variety of harmful effects in astronauts, resulting in altered motor and cognitive behavior. The stresses experienced by humans in space - most significantly weightlessness (microgravity) and cosmic radiation - are difficult to accurately simulate on Earth. In fact, prolonged and concomitant exposure to microgravity and cosmic radiation can only be studied in space. Behavioral studies in space have focused on model organisms, including Drosophila melanogaster. Drosophila is often used due to its short life span and generational cycle, small size, and ease of maintenance. Additionally, the well-characterized genetics of Drosophila behavior on Earth can be applied to the analysis of results from spaceflights, provided that the behavior in space is accurately recorded. In 2001, the BioExplorer project introduced a low-cost option for researchers: the small satellite. While this approach enabled multiple inexpensive launches of biological experiments, it also imposed stringent restrictions on the monitoring systems in terms of size, mass, data bandwidth, and power consumption. Suggested parameters for size are on the order of 100 mm3 and 1 kg mass for the entire payload. For Drosophila behavioral studies, these engineering requirements are not met by commercially available systems. One system that does meet many requirements for behavioral studies in space is the actimeter. Actimeters use infrared light gates to track the number of times a fly crosses a boundary within a small container (3x3x40 mm). Unfortunately, the apparatus needed to monitor several flies at once would be larger than the capacity of the small satellite. A system is presented, which expands on the actimeter approach to achieve a highly compact, low-power, ultra-low bandwidth solution for simultaneous monitoring of the behavior of multiple flies in space. This also provides a simple, inexpensive alternative to the current systems for monitoring Drosophila populations in terrestrial experiments, and could be especially useful in field experiments in remote locations. Two practical limitations of the system should be noted: first, only walking flies can be observed - not flying - and second, although it enables population studies, tracking individual flies within the population is not currently possible. The system used video recording and an analog circuit to extract the average light changes as a function of time. Flies were held in a 5-cm diameter Petri dish and illuminated from below by a uniform light source. A miniature, monochrome CMOS (complementary metal-oxide semiconductor) video camera imaged the flies. This camera had automatic gain control, and this did not affect system performance. The camera was positioned 5-7 cm above the Petri dish such that the imaging area was 2.25 sq cm. With this basic setup, still images and continuous video of 15 flies at one time were obtained. To reduce the required data bandwidth by several orders of magnitude, a band-pass filter (0.3-10 Hz) circuit compressed the video signal and extracted changes in image luminance over time. The raw activity signal output of this circuit was recorded on a computer and digitally processed to extract the fly movement "events" from the waveform. These events corresponded to flies entering and leaving the image and were used for extracting activity parameters such as inter-event duration. The efficacy of the system in quantifying locomotor activity was evaluated by varying environmental temperature, then measuring the activity level of the flies.

Bhattacharya, Sharmila↗

A Technique to Measure Coronal Electron Density, Temperature, and Velocity Above 2.5 R from Sun Center Using Polarized Brightness Spectrum

The current model for the polarized brightness (pB) spectrum has a decades-long history of progressively incorporating its dependence on electron density N(e), temperature T(e), and flow velocity in the radial direction V(e). The pBNe spectrum follows the exact shape of the photosphere spectrum, which is not smooth, which is expected from the thermal Doppler broadening of the photosphere spectrum due to the high coronal T(e). The pBN(e) spectrum is smooth, but the free coronal electrons remain static and unaffected by solar wind, and the pBN(e)T(e)V(e) spectrum is red-shifted by electrons seeing a red-shifted photosphere spectrum as they flow away from the Sun as solar wind, which takes a radial direction above 2.5 R from Sun center. In this article, we review the progress of the above three model pB spectra in describing the observations and highlight the differences, first by comparing the three model pB spectra against wavelength using a model for Ne and constant values for T(e) and V (e), and second by generating three model 2D pB maps by integrating over a selected wavelength region in the three model pB spectra along lines of sight passing through the 14 July 2000 (“Bastille Day”) coronal mass ejection (CME) model, which contains 3D information on N(e), T(e), and V e. In this regard, the COronal Diagnostic EXperiment (CODEX) on the International Space Station (ISS) in 2024 will measure N(e), T(e), and V(e) by matching the measured pB with modeled pBN(e)T(e)V(e) in selected wavelength regions using multiple filters.

Electron density↗

Air Separation Using Hollow Fiber Membranes

The NASA Glenn Research Center in partnership with the Ohio Aerospace Institute provides internship programs for high school and college students in the areas of science, engineering, professional administrative, and other technical areas. During the summer of 2004, I worked with Dr. Clarence T. Chang at NASA Glenn Research Center s combustion branch on air separation using hollow fiber membrane technology. . In light of the accident of Trans World Airline s flight 800, FAA has mandated that a suitable solution be created to prevent the ignition of fuel tanks in aircrafts. In order for any type of fuel to ignite, three important things are needed: fuel vapor, oxygen, and an energy source. Two different ways to make fuel tanks less likely to ignite are reformulating the fuel to obtain a lower vapor pressure for the fuel and or using an On Board Inert Gas Generating System (OBIGGS) to inert the Central Wing Tank. goal is to accomplish the mission, which means that the Air Separation Module (ASM) tends to be bulky and heavy. The primary goal for commercial aviation companies is to transport as much as they can with the least amount of cost and fuel per person, therefore the ASM must be compact and light as possible. The plan is to take bleed air from the aircraft s engines to pass air through a filter first to remove particulates and then pass the air through the ASM containing hollow fiber membranes. In the lab, there will be a heating element provided to simulate the temperature of the bleed air that will be entering the ASM and analysis of the separated air will be analyzed by a Gas Chromatograph/Mass Spectrometer (GC/MS). The GUMS will separate the different compounds in the exit streams of the ASM and provide information on the performance of hollow fiber membranes. Hopefully I can develop ways to improve efficiency of the ASM. different types of jet fuel were analyzed and data was well represented on SAE Paper 982485. Data consisted of the concentrations of over 300 different hydrocarbons commonly found in JP- 8, Jet A, and JP-5 fuels. I researched the major hydrocarbons that has a concentration of greater than 50 parts per million and found the vapor pressure data coefficients for a specific temperature range. The coefficients were applied to Antoine s Equation and Riedel's Equation to calculate the vapor pressures for that specific hydrocarbon in the specific temperature range. With the vapor pressure data scientists can formulate a fuel composition that has a lower vapor pressure profile, therefore making jet fuels less flammable. work, learn how to operate and examine the data from Gas Chromatograph and Mass Spectrometer, and develop new ways in applying hollow fiber membrane technology to other areas of environmental engineering. The United States military currently uses air separation technology and their primary The other side of making air travel safer is to reformulate the fuel. Analyses of three My goal this summer is to learn about hollow fiber membrane technologies and how they

Huang, Stephen E.↗

A Technique to Measure Coronal Electron Density, Temperature, and Velocity Above 2.5 R⨀ from Sun Center using Polarized Brightness Spectrum

The current model for the polarized brightness (pB) spectrum has a decades-long history of progressively incorporating its dependence on electron density Ne, temperature Te, and flow velocity in the radial direction V e . The pB N e spectrum follows the exact shape of the photosphere spectrum, which is not smooth, which is expected from the thermal Doppler broadening of the photosphere spectrum due to the high coronal T e ; the pB N e T e spectrum is smooth, but the free coronal electrons remain static and unaffected by solar wind, and the pB N e T e V e spectrum is red-shifted by electrons seeing a red-shifted photosphere spectrum as they flow away from the Sun as solar wind, which takes a radial direction above 2.5 R ⨀ from Sun center. In this article, we review the progress of the above three model pB spectra in describing the observations and highlight the differences, first by comparing the three model pB spectra against wavelength using a model for Ne and constant values for T e and V e , and second by generating three model 2D pB maps by integrating over a selected wavelengthregion in the three model pB spectra along lines of sight passing through the 14 July 2000 (“Bastille Day”) coronal mass ejection (CME) model, which contains 3D information on N e , T e , and V e . In this regard, the COronal Diagnostic EXperiment (CODEX) on the International Space Station (ISS) in 2024 will measure N e , T e , and V e by matching the measured pB with modeled pB N e T e V e in selected wavelength regions using multiple filters.

Electron density↗

Deep-Sea Hydrothermal-Vent Sampler

An apparatus is being developed for sampling water for signs of microbial life in an ocean hydrothermal vent at a depth of as much as 6.5 km. Heretofore, evidence of microbial life in deep-sea hydrothermal vents has been elusive and difficult to validate. Because of the extreme conditions in these environments (high pressures and temperatures often in excess of 300 C), deep-sea hydrothermal- vent samplers must be robust. Because of the presumed low density of biomass of these environments, samplers must be capable of collecting water samples of significant volume. It is also essential to prevent contamination of samples by microbes entrained from surrounding waters. Prior to the development of the present apparatus, no sampling device was capable of satisfying these requirements. The apparatus (see figure) includes an intake equipped with a temperature probe, plus several other temperature probes located away from the intake. The readings from the temperature probes are utilized in conjunction with readings from flowmeters to determine the position of the intake relative to the hydrothermal plume and, thereby, to position the intake to sample directly from the plume. Because it is necessary to collect large samples of water in order to obtain sufficient microbial biomass but it is not practical to retain all the water from the samples, four filter arrays are used to concentrate the microbial biomass (which is assumed to consist of particles larger than 0.2 m) into smaller volumes. The apparatus can collect multiple samples per dive and is designed to process a total volume of 10 L of vent fluid, of which most passes through the filters, leaving a total possibly-microbe-containing sample volume of 200 mL remaining in filters. A rigid titanium nose at the intake is used for cooling the sample water before it enters a flexible inlet hose connected to a pump. As the water passes through the titanium nose, it must be cooled to a temperature that is above a mineral-precipitation temperature of 100 C but below the upper working temperature (230 C) of switching valves and tubes in the apparatus. The sample water then passes into a manifold tube, from whence the switching valves can direct the water through either a bypass tube or any one of the filter arrays, without contamination from a previous sample. Each filter array consists of series of filters having pore sizes decreasing in the direction of flow: 90-, 60-, 15-, and 7-micron prefilters and a large-surface-area 0.2-micron collection filter. All the filter taps are located between the intake and the bypass tube so that each time the bypass tube is used, the entire manifold tube is flushed as well.

Behar, Alberto E.↗

Magnetometer Based on Optoelectronic Microwave Oscillator

proposed instrument, intended mainly for use as a magnetometer, would include an optoelectronic oscillator (OEO) stabilized by an atomic cell that could play the role of a magnetically tunable microwave filter. The microwave frequency would vary with the magnetic field in the cell, thereby providing an indication of the magnetic field. The proposed magnetometer would offer a combination of high accuracy and high sensitivity, characterized by flux densities of less than a picotesla. In comparison with prior magnetometers, the proposed magnetometer could, in principle, be constructed as a compact, lightweight instrument: It could fit into a package of about 10 by 10 by 10 cm and would have a mass <0.5 kg. As described in several prior NASA Tech Briefs articles, an OEO is a hybrid of photonic and electronic components that generates highly spectrally pure microwave radiation, and optical radiation modulated by the microwave radiation, through direct conversion between laser light and microwave radiation in an optoelectronic feedback loop. As used here, "atomic cell" signifies a cell containing a vapor, the constituent atoms of which can be made to undergo transitions between quantum states, denoted hyperfine levels, when excited by light in a suitable wavelength range. The laser light must be in this range. The energy difference between the hyperfine levels defines the microwave frequency. In the proposed instrument (see figure), light from a laser would be introduced into an electro-optical modulator (EOM). Amplitude-modulated light from the exit port of the EOM would pass through a fiber-optic splitter having two output branches. The light in one branch would be sent through an atomic cell to a photodiode. The light in the other branch would constitute the microwave-modulated optical output. Part of the light leaving the atomic cell could also be used to stabilize the laser at a frequency in the vicinity of the desired hyperfine or other quantum transition. The microwave signal from the output of the photodiode would be amplified (if necessary, as explained below) and fed back into the EOM. This system would oscillate if the amplification in the closed loop exceeded the linear absorption of the loop. The microwave amplifier may be unnecessary to sustain stable oscillations, depending on the power of the laser radiation at the photodetector and on particular features of the modulator and optical delay line.

Maleki, Lute↗

Miniature Ion-Mobility Spectrometer

The figure depicts a proposed miniature ion-mobility spectrometer that would be fabricated by micromachining. Unlike prior ion-mobility spectrometers, the proposed instrument would not be based on a time-of-flight principle and, consequently, would not have some of the disadvantageous characteristics of prior time-of-flight ion-mobility spectrometers. For example, one of these characteristics is the need for a bulky carrier-gas-feeding subsystem that includes a shutter gate to provide short pulses of gas in order to generate short pulses of ions. For another example, there is need for a complex device to generate pulses of ions from the pulses of gas and the device is capable of ionizing only a fraction of the incoming gas molecules; these characteristics preclude miniaturization. In contrast, the proposed instrument would not require a carrier-gas-feeding subsystem and would include a simple, highly compact device that would ionize all the molecules passing through it. The ionization device in the proposed instrument would be a 0.1-micron-thick dielectric membrane with metal electrodes on both sides. Small conical holes would be micromachined through the membrane and electrodes. An electric potential of the order of a volt applied between the membrane electrodes would give rise to an electric field of the order of several megavolts per meter in the submicron gap between the electrodes. An electric field of this magnitude would be sufficient to ionize all the molecules that enter the holes. Ionization (but not avalanche arcing) would occur because the distance between the ionizing electrodes would be less than the mean free path of gas molecules at the operating pressure of instrument. An accelerating grid would be located inside the instrument, downstream from the ionizing membrane. The electric potential applied to this grid would be negative relative to the potential on the inside electrode of the ionizing membrane and would be of a magnitude sufficient to generate a moderate electric field. Positive ions leaving the membrane holes would be accelerated in this electric field. The resulting flux of ions away from the ionization membrane would create a partial vacuum that would draw more of the gas medium through the membrane. The figure depicts a filter electrode and detector electrodes located along the sides of a drift tube downstream from the accelerator electrode. These electrodes would apply a transverse AC electric field superimposed on a ramped DC electric field. The AC field would effect differential transverse dispersal of ions. At a given instant of time, the trajectories of most of the ions would be bent toward the electrodes, causing most of the ions to collide with the electrodes and thereby become neutralized. The DC field would partly counteract the dispersive effect of the AC field, straightening the trajectories of a selected species of ions; the selection would vary with the magnitude of the applied DC field. The straightening of the trajectories of the selected ions would enable them to pass into the region between the detector electrodes. Depending on the polarity of the voltage applied to the detector electrodes, the electric field between the detector electrodes would draw the selected ions to one of these electrodes. Hence, the current collected by one of the detector electrodes would be a measure of the abundance of ions of the selected species. The ramping of the filter- electrode DC voltage would sweep the selection of ions through the spectrum of ionic species.

Hartley, Frank T.↗

Solar Rotational Periodicities and the Semiannual Variation in the Solar Wind, Radiation Belt, and Aurora

The behavior of a number of solar wind, radiation belt, auroral and geomagnetic parameters is examined during the recent extended solar minimum and previous solar cycles, covering the period from January 1972 to July 2010. This period includes most of the solar minimum between Cycles 23 and 24, which was more extended than recent solar minima, with historically low values of most of these parameters in 2009. Solar rotational periodicities from S to 27 days were found from daily averages over 81 days for the parameters. There were very strong 9-day periodicities in many variables in 2005 -2008, triggered by recurring corotating high-speed streams (HSS). All rotational amplitudes were relatively large in the descending and early minimum phases of the solar cycle, when HSS are the predominant solar wind structures. There were minima in the amplitudes of all solar rotational periodicities near the end of each solar minimum, as well as at the start of the reversal of the solar magnetic field polarity at solar maximum (approx.1980, approx.1990, and approx. 2001) when the occurrence frequency of HSS is relatively low. Semiannual equinoctial periodicities, which were relatively strong in the 1995-1997 solar minimum, were found to be primarily the result of the changing amplitudes of the 13.5- and 27-day periodicities, where 13.5-day amplitudes were better correlated with heliospheric daily observations and 27-day amplitudes correlated better with Earth-based daily observations. The equinoctial rotational amplitudes of the Earth-based parameters were probably enhanced by a combination of the Russell-McPherron effect and a reduction in the solar wind-magnetosphere coupling efficiency during solstices. The rotational amplitudes were cross-correlated with each other, where the 27 -day amplitudes showed some of the weakest cross-correlations. The rotational amplitudes of the > 2 MeV radiation belt electron number fluxes were progressively weaker from 27- to 5-day periods, showing that processes in the magnetosphere act as a low-pass filter between the solar wind and the radiation belt. The A(sub p)/K(sub p) magnetic currents observed at subauroral latitudes are sensitive to proton auroral precipitation, especially for 9-day and shorter periods, while the A(sub p)/K(sub p) currents are governed by electron auroral precipitation for 13.5- and 27-day periodicities.

Emery, Barbara A.↗

An Accreting White Dwarf near the Chandrasekhar Limit in the Andromeda Galaxy

The iPTF (Intermediate Palomar Transient Factory) detection of the most recent outburst of the recurrent nova system RX J0045.4+4154 in the Andromeda Galaxy has enabled the unprecedented study of a massive (mass is greater than 1.3 solar masses) accreting white dwarf (WD). We detected this nova as part of the near daily iPTF monitoring of M31 to a depth of R (red band-pass filter) approximately equal to magnitude 21 and triggered optical photometry, spectroscopy and soft X-ray monitoring of the outburst. Peaking at an absolute magnitude of MR (red, mid-infrared band-pass filter) equals magnitude −6.6, and with a decay time of 1 magnitude per day, it is a faint and very fast nova. It shows optical emission lines of He/N and expansion velocities of 1900 to 2600 kilometers per second 1-4 days after the optical peak. The Swift monitoring of the X-ray evolution revealed a supersoft source (SSS) with kT (energy: Boltzmann constant times temperature) (sub eff (effective)) approximately equal to 90-110 electronvolts that appeared within 5 days after the optical peak, and lasted only 12 days. Most remarkably, this is not the first event from this system, rather it is a recurrent nova with a time between outbursts of approximately 1 year, the shortest known. Recurrent X-ray emission from this binary was detected by ROSAT in 1992 and 1993, and the source was well characterized as a mass greater than 1.3 solar masses WD SSS. Based on the observed recurrence time between different outbursts, the duration and effective temperature of the SS phase, MESA models of accreting WDs allow us to constrain the accretion rate to mass greater than 1.7x10 (sup −7) solar masses per year and WD mass greater than 1.30 solar masses. If the WD keeps 30 percent of the accreted material, it will take less than a million years to reach core densities high enough for carbon ignition (if made of C/O) or electron capture (if made of O/Ne) to end the binary evolution.

dwarf↗

Fast Offset Laser Phase-Locking System

Figure 1 shows a simplified block diagram of an improved optoelectronic system for locking the phase of one laser to that of another laser with an adjustable offset frequency specified by the user. In comparison with prior systems, this system exhibits higher performance (including higher stability) and is much easier to use. The system is based on a field-programmable gate array (FPGA) and operates almost entirely digitally; hence, it is easily adaptable to many different systems. The system achieves phase stability of less than a microcycle. It was developed to satisfy the phase-stability requirement for a planned spaceborne gravitational-wave-detecting heterodyne laser interferometer (LISA). The system has potential terrestrial utility in communications, lidar, and other applications. The present system includes a fast phasemeter that is a companion to the microcycle-accurate one described in High-Accuracy, High-Dynamic-Range Phase-Measurement System (NPO-41927), NASA Tech Briefs, Vol. 31, No. 6 (June 2007), page 22. In the present system (as in the previously reported one), beams from the two lasers (here denoted the master and slave lasers) interfere on a photodiode. The heterodyne photodiode output is digitized and fed to the fast phasemeter, which produces suitably conditioned, low-latency analog control signals which lock the phase of the slave laser to that of the master laser. These control signals are used to drive a thermal and a piezoelectric transducer that adjust the frequency and phase of the slave-laser output. The output of the photodiode is a heterodyne signal at the difference between the frequencies of the two lasers. (The difference is currently required to be less than 20 MHz due to the Nyquist limit of the current sampling rate. We foresee few problems in doubling this limit using current equipment.) Within the phasemeter, the photodiode-output signal is digitized to 15 bits at a sampling frequency of 40 MHz by use of the same analog-to-digital converter (ADC) as that of the previously reported phasemeter. The ADC output is passed to the FPGA, wherein the signal is demodulated using a digitally generated oscillator signal at the offset locking frequency specified by the user. The demodulated signal is low-pass filtered, decimated to a sample rate of 1 MHz, then filtered again. The decimated and filtered signal is converted to an analog output by a 1 MHz, 16-bit digital-to-analog converters. After a simple low-pass filter, these analog signals drive the thermal and piezoelectric transducers of the laser.

Shaddock, Daniel↗

HEASARC Software Archive

(1) Chandra Archive: SAO has maintained the interfaces through which HEASARC gains access to the Chandra Data Archive. At HEASARC's request, we have implemented an anonymous ftp copy of a major part of the public archive and we keep that archive up-to- date. SAO has participated in the ADEC interoperability working group, establishing guidelines or interoperability standards and prototyping such interfaces. We have provided an NVO-based prototype interface, intending to serve the HEASARC-led NVO demo project. HEASARC's Astrobrowse interface was maintained and updated. In addition, we have participated in design discussions surrounding HEASARC's Caldb project. We have attended the HEASARC Users Group meeting and presented CDA status and developments. (2) Chandra CALDB: SA0 has maintained and expanded the Chandra CALDB by including four new data file types, defining the corresponding CALDB keyword/identification structures. We have provided CALDB upgrades for the public (CIAO) and for Standard Data Processing. Approximately 40 new files have been added to the CALDB in these version releases. There have been in the past year ten of these CALDB upgrades, each with unique index configurations. In addition, with the inputs from software, archive, and calibration scientists, as well as CIAO/SDP software developers, we have defined a generalized expansion of the existing CALDB interface and indexing structure. The purpose of this is to make the CALDB more generally applicable and useful in new and future missions that will be supported archivally by HEASARC. The generalized interface will identify additional configurational keywords and permit more extensive calibration parameter and boundary condition specifications for unique file selection. HEASARC scientists and developers from SAO and GSFC have become involved in this work, which is expected to produce a new interface for general use within the current year. (3) DS9: One of the decisions that came from last year's HEADCC meeting was to make the ds9 image display program the primary vehicle for displaying line graphics (as well as images). The first step required to make this possible was to enhance the line graphics capabilities of ds9. SAO therefore spent considerable effort upgrading ds9 to use Tcl 8.4 so that the BLT line graphics package could be built and imported into ds9 from source code, rather than from a pre-built (and generally outdated) shared library. This task, which is nearly complete, allows us to extend BLT as needed for the HEAD community. Following HEADCC discussion concerning archiving and the display of archived data, we extended ds9 to support full access to many astronomical Web-based archives sites, including HEASARC, MAST, CHANDRA, SKYVIEW, ADS, NED, SIMBAD, IRAS, NVRO, SAO TDC, and FIRST. Using ds9's new internal Web access capabilities, these archives can be accessed via their Web page. FITS images, plots, spectra, and journal abstracts can be referenced, down-loaded, and displayed directly and easily in ds9. For more information, see: http://hea-www.harvard.edu/saord/ds9. Also after the HEADCC discussion concerning region filtering, we extended the Funtools sample implementation of region filtering as described in: http://hea-www.harvard.edu/saord/funtools/regions.html. In particular, we added several new composite regions for event and image filtering, including elliptical and box annuli. We also extended the panda (Pie AND Annulus) region support to include box pandas and elliptical pandas. These new composite regions are especially useful in programs that need to count photons in each separate region using only a single pass through the data. Support for these new regions was added to ds9. In the same vein, we developed new region support for filtering images using simple FITS image masks, i.e. 8-bit or 16-bit FITS images where the value of a pixel is the region id number for that pixel. Other important enhancements to DS9 this year, include supporor multiple world coordinate systems, three dimensional event file binning, image smoothing, region groups and tags, the ability to save images in a number of image formats (such as JPEG, TIFF, PNG, FITS), improvements in support for integrating external analysis tools, and support for the virtual observatory. In particular, a full-featured web browser has been implemented within D S 9 . This provides support for full access to HEASARC archive sites such as SKYVIEW and W3BROWSE, in addition to other astronomical archives sites such as MAST, CHANDRA, ADS, NED, SIMBAD, IRAS, NVRO, SA0 TDC, and FIRST. From within DS9, the archives can be searched, and FITS images, plots, spectra, and journal abstracts can be referenced, downloaded and displayed The web browser provides the basis for the built-in help facility. All DS9 documentation, including the reference manual, FAQ, Know Features, and contact information is now available to the user without the need for external display applications. New versions of DS9 maybe downloaded and installed using this facility. Two important features used in the analysis of high energy astronomical data have been implemented in the past year. The first is support for binning photon event data in three dimensions. By binning the third dimension in time or energy, users are easily able to detect variable x-ray sources and identify other physical properties of their data. Second, a number of fast smoothing algorithms have been implemented in DS9, which allow users to smooth their data in real time. Algorithms for boxcar, tophat, and gaussian smoothing are supported.

White, Nicholas↗

Biasable, Balanced, Fundamental Submillimeter Monolithic Membrane Mixer

This device is a biasable, submillimeter-wave, balanced mixer fabricated using JPL s monolithic membrane process a simplified version of planar membrane technology. The primary target application is instrumentation used for analysis of atmospheric constituents, pressure, temperature, winds, and other physical and chemical properties of the atmospheres of planets and comets. Other applications include high-sensitivity gas detection and analysis. This innovation uses a balanced configuration of two diodes allowing the radio frequency (RF) signal and local oscillator (LO) inputs to be separated. This removes the need for external diplexers that are inherently narrowband, bulky, and require mechanical tuning to change frequency. Additionally, this mixer uses DC bias-ability to improve its performance and versatility. In order to solve problems relating to circuit size, the GaAs membrane process was created. As much of the circuitry as possible is fabricated on-chip, making the circuit monolithic. The remainder of the circuitry is precision-machined into a waveguide block that holds the GaAs circuit. The most critical alignments are performed using micron-scale semiconductor technology, enabling wide bandwidth and high operating frequencies. The balanced mixer gets superior performance with less than 2 mW of LO power. This can be provided by a simple two-stage multiplier chain following an amplifier at around 90 GHz. Further, the diodes are arranged so that they can be biased. Biasing pushes the diodes closer to their switching voltage, so that less LO power is required to switch the diodes on and off. In the photo, the diodes are at the right end of the circuit. The LO comes from the waveguide at the right into a reduced-height section containing the diodes. Because the diodes are in series to the LO signal, they are both turned on and off simultaneously once per LO cycle. Conversely, the RF signal is picked up from the RF waveguide by the probe at the left, and flows rightward to the diodes. Because the RF is in a quasi- TEM (suspended, microstrip-like) mode, it impinges on the diodes in an anti-parallel mode that does not couple to the waveguide mode. This isolates the LO and RF signals. This operation is similar to a cross-bar mixer used at low frequencies, except the RF signal enters through the back-short end of the waveguide rather than through the side. The RF probe also conveys the down-converted intermediate frequency (IF) signal out to an off-chip circuit board through a simple LC low-pass filter to the left as indicated. The bias is brought to the diodes through a bypass capacitor at the top.

Siegel, Peter↗

High-Performance Wireless Telemetry

Prior technology for machinery data acquisition used slip rings, FM radio communication, or non-real-time digital communication. Slip rings are often noisy, require much space that may not be available, and require access to the shaft, which may not be possible. FM radio is not accurate or stable, and is limited in the number of channels, often with channel crosstalk, and intermittent as the shaft rotates. Non-real-time digital communication is very popular, but complex, with long development time, and objections from users who need continuous waveforms from many channels. This innovation extends the amount of information conveyed from a rotating machine to a data acquisition system while keeping the development time short and keeping the rotating electronics simple, compact, stable, and rugged. The data are all real time. The product of the number of channels, times the bit resolution, times the update rate, gives a data rate higher than available by older methods. The telemetry system consists of a data-receiving rack that supplies magnetically coupled power to a rotating instrument amplifier ring in the machine being monitored. The ring digitizes the data and magnetically couples the data back to the rack, where it is made available. The transformer is generally a ring positioned around the axis of rotation with one side of the transformer free to rotate and the other side held stationary. The windings are laid in the ring; this gives the data immunity to any rotation that may occur. A medium-frequency sine-wave power source in a rack supplies power through a cable to a rotating ring transformer that passes the power on to a rotating set of electronics. The electronics power a set of up to 40 sensors and provides instrument amplifiers for the sensors. The outputs from the amplifiers are filtered and multiplexed into a serial ADC. The output from the ADC is connected to another rotating ring transformer that conveys the serial data from the rotating section to the stationary section. From there, a cable conveys the serial data to the remote rack, where it is reconditioned to logic level specifications, de-serialized, and converted back to analog. In the rotating electronics are code generators to indicate the beginning of files for data synchronization.

Griebeler, Elmer↗