Transient heat transfer gauge Patent
Transient heat transfer gage for measuring total radiant intensity from far ultraviolet and ionized high temperature gases
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Transient heat transfer gage for measuring total radiant intensity from far ultraviolet and ionized high temperature gases
Heat sink capabilities of Jet-A fuel - heat transfer and coking studies
Heat transfer and flow characteristics of UF6 flowing in a gas core reactor were analyzed through solution of the energy equation. The thermal-physical properties of UF6 are given.
The problem of turbulent flow heat transfer in a concentric circular tube annulus with fully developed velocity profile and constant heat rate per unit of length is considered. Experimentally obtained solutions are presented for the thermal entry length for a fluid with P(sub r) = 0·7. Asymptotic solutions (fully developed velocity and temperature profiles) are developed for a wide range of radius ratio, Reynolds number, and Prandtl number. The solutions are based on empirical velocity and eddy diffusivity profiles, and the validity of the solutions is demonstrated experimentally for P(sub r) = 0·7. A superposition method is demonstrated for solving the problem of asymmetric heating from the two surfaces of an annulus, and experimental data on asymmetric heating are presented which are in excellent agreement with the analysis. This paper is the third in a series (1, 2) culminating a four year study of heat transfer in annular passages.
Heat transfer between cladding and coolant during transient scenarios remains a critical area of uncertainty in understanding nuclear reactor safety. To advance the understanding of transient and accident scenarios involving critical heat flux (CHF), an in-pile experiment for the Transient Reactor Test (TREAT) facility at Idaho National Laboratory was developed. The experiment named CHF-Static Environment Rodlet Transient Test Apparatus (CHF-SERTTA), consists of a hollow borated stainless steel heater rod submerged in a static water pool which is heated via the (n, a) reaction in boron-10. This paper presents a novel inverse heat transfer method to determine CHF by using the optimization and uncertainty software DAKOTA to calibrate a RELAP5-3D model of CHF-SERTTA to temperature measurements obtained from a thermocouple welded to the surface of the rod.
The proposed paper compares predicted turbine vane heat transfer for a rough surface over a wide range of test conditions with experimental data. Predictions were made for the entire vane surface. However, measurements were made only over the suction surface of the vane, and the leading edge region of the pressure surface. Comparisons are shown for a wide range of test conditions. Inlet pressures varied between 3 and 15 psia, and exit Mach numbers ranged between 0.3 and 0.9. Thus, while a single roughened vane was used for the tests, the effective rougness,(k(sup +)), varied by more than a factor of ten. Results were obtained for freestream turbulence levels of 1 and 10%. Heat transfer predictions were obtained using the Navier-Stokes computer code RVCQ3D. Two turbulence models, suitable for rough surface analysis, are incorporated in this code. The Cebeci-Chang roughness model is part of the algebraic turbulence model. The k-omega turbulence model accounts for the effect of roughness in the application of the boundary condition. Roughness causes turbulent flow over the vane surface. Even after accounting for transition, surface roughness significantly increased heat transfer compared to a smooth surface. The k-omega results agreed better with the data than the Cebeci-Chang model. However, the low Reynolds number k-omega model did not accurately account for roughness when the freestream turbulence level was low. The high Reynolds number version of this model was more suitable when the freestream turbulence was low.
An experimental investigation is presented that was performed to determine the effect of a surface-to-gap wall temperature discontinuity on the heat transfer within space shuttle, reusable surface insulation, tile gaps submerged in a thick turbulent boundary layer. Heat-transfer measurements were obtained on a flat-plate, single-gap model submerged in a turbulent tunnel wall boundary layer at a nominal free-stream Mach number of 10.3 and free-stream Reynolds numbers per meter of 1.5 million, 3.3 million and 7.8 million. Surface-to-gap wall temperature discontinuities of varying degree were created by heating the surface of the model upstream of the instrumented gap. The sweep angle of the gap was varied between 0 deg and 60 deg; gap width and depth were held constant. A surface-to-gap wall temperature discontinuity (surface temperature greater than gap wall temperature) results in increased heat transfer to the near-surface portion of the gap, as compared with the heat transfer under isothermal conditions, while decreasing the heat transfer to the deeper portions of the gap. The nondimensionalized heat transfer to the near-surface portion of the gap is shown to decrease with increasing Reynolds number; in the deeper portion of the gap, the heat transfer increases with Reynolds number.
An experimental investigation was performed to determine the effect of pressure gradient on the heat transfer within space shuttle reusable surface insulation (RSI) tile-array gaps under thick, turbulent boundary-layer conditions. Heat-transfer and pressure measurements were obtained on a curved array of full-scale simulated RSI tiles in a tunnel-wall boundary layer at a nominal free-stream Mach number and free-stream Reynolds numbers. Transverse pressure gradients of varying degree were induced over the model surface by rotating the curved array with respect to the flow. Definition of the tunnel-wall boundary-layer flow was obtained by measurement of boundary-layer pitot pressure profiles, wall pressure, and heat transfer. Flat-plate heat-transfer data were correlated and a method was derived for prediction of heat transfer to a smooth curved surface in the highly three-dimensional tunnel-wall boundary-layer flow. Pressure on the floor of the RSI tile-array gap followed the trends of the external surface pressure. Heat transfer to the surface immediately downstream of a transverse gap is higher than that for a smooth surface at the same location. Heating to the wall of a transverse gap, and immediately downstream of it, at its intersection with a longitudinal gap is significantly greater than that for the simple transverse gap.
An experimental study of heat transfer into a thin liquid film on a rotating heated disk is described. Deionized water was introduced at the center of a heated. horizontal disk with a constant film thickness and uniform radial velocity. Radial distribution of the disk surface temperatures was measured using a thermocouple/slip ring arrangement. Experiments were performed for a range of liquid flow rates between 3.01pm and 15.01pm. The angular speed of the disk was varied from 0 rpm to 500 rpm. The local heat transfer coefficient was determined based on the heat flux supplied to the disk and the temperature difference between the measured disk surface temperature and the liquid entrance temperature onto the disk. The local heat transfer coefficient was seen to increase with increasing flow rate as well as increasing angular velocity of the disk. Effect of rotation on heat transfer was largest for the lower liquid flow rates with the effect gradually decreasing with increasing liquid flow rates. Semi-empirical correlations are presented in this study for the local and average Nusselt numbers.
A set of analyses was conducted to determine the heat transfer characteristics of metallized gelled liquid propellants in a rocket engine. The analyses used the data from experiments conducted with a small 30- to 40-lbf thrust engine composed of a modular injector, igniter, chamber and nozzle. The fuels used were traditional liquid RP-1 and gelled RP-1 with 0-wt %, 5-wt%, and 55-wt% loadings of aluminum with silicon dioxide gellant, and gaseous oxygen as the oxidizer. Heat transfer was computed based on measurements using calorimeter rocket chamber and nozzle hardware with a total of 31 cooling channels. A gelled fuel coating formed in the 0-, 5- and 55-wt% engines, and the coating was composed of unburned gelled fuel and partially combusted RP-1. The coating caused a large decrease in calorimeter engine heat flux in the last half of the chamber for the 0- and 5-wt% RP-1/Al. This heat flux reduction effect was analyzed by comparing engine runs and the changes in the heat flux during a run as well as from run to run. Heat transfer and time-dependent heat flux analyses and interpretations are provided. The 5- and 55-wt% RP-1/Al fueled engines had the highest chamber heat fluxes, with the 5-wt% fuel having the highest throat flux. This result is counter to the predicted result, where the 55 wt% fuel has the highest combustion and throat temperature, and therefore implies that it would deliver the highest throat heat flux. The 5-wt% RP-1/Al produced the most influence on the engine heat transfer and the heat flux reduction was caused by the formation of a gelled propellant layer in the chamber and nozzle.
In order to meet the future needs of thermal management and control in space applications such as the Space Lab, new heat-transfer technology capable of much larger heat fluxes must be developed. To this end, we describe complementary numerical and experimental investigations into the fundamental fluid mechanics and heat-transfer processes involved in a radically new, self contained, heat transfer cell for microgravity applications. In contrast to conventional heat pipes, the heat transfer in this cell is based on a forced droplet evaporation process using a fine spray. The spray is produced by a novel fluidic technology recently developed at Georgia Tech. This technology is based on a vibration induced droplet atomization process. In this technique, a liquid droplet is placed on a flexible membrane and is vibrated normal to itself. When the proper drop size is attained, the droplet resonates with the surface motion of the membrane and almost immediately bursts into a shower of very fine secondary droplets. The small droplets travel to the opposite end of the cell where they impact a heated surface and are evaporated. The vapor returns to the cold end of the cell and condenses to form the large droplets that are fragmented to form the spray. Preliminary estimates show that a heat transfer cell based on this technology would have a heat-flux capacity that is an order of magnitude higher than those of current heat pipes designs used in microgravity applications.
The rate of heat transfer by natural convection between the wall and electrolyte of an electrolytic cell that produces magnesium (Mg) from magnesium oxide (MgO) at temperatures near 1000 °C in a molten fluoride salt electrolyte is presented. An experimental model of the cell was developed that enabled measurements of the heat transfer in the absence of electrolysis and at temperatures less than 100 °C over ranges of Rayleigh numbers from 1 × 10 -7 to 7 × 10 -8 and Prandtl numbers from 2 to 6200, ranges that include those anticipated in the operation of the MgO electrolytic cell. The model avoids the substantial experimental challenges associated with the high-temperature, corrosive molten salt to enable a conservative estimate of the heat transfer at a lower cost and greater accuracy than would otherwise be possible. The results are correlated by the expression Nu = 0.412Ra 0.23 Pr 0.15 with Nusselt numbers spanning 30–80. The application of the correlation shows that the heat transfer between the cell wall and the molten fluoride electrolyte at ≈1000 °C is characterized by convection coefficients between 100 and 600 W/m 2 -K and is fast enough to enable heat fluxes up to 10 W/cm 2 without compromising the structural integrity of the steel cell wall.
A numerical modeling is to examine the effects of coolant convective heat transfer coefficient and frictional heating on the local temperature characteristics of a ball element in Space Shuttle Main Engine (SSME) High Pressure Oxidizer Turbopump (HPOTP) bearing. The present modeling uses a control-volume based, finite-difference method to solve the non-dimensionalized heat conduction equation in spherical coordinate system. The dimensionless temperature is found as a function of Biot number, heat flux ratio between the two race contacts, and location in the ball. The current results show that, for a given cooling capability, the ball temperature generally increases almost linearly with the heat input from the race-contacts. This increase is always very high at one of the two contacts. An increase in heat transfer coefficient generally reduces the ball temperature and alleviates the temperature gradient, except for the regions very close to the race contacts. For a 10-fold increase of heat transfer coefficient, temperature decrease is 35 percent for the average over entire ball, and 10 percent at the inner-race contact. The corresponding change of temperature gradient displays opposing trends between the regions immediately adjacent to the contacts and the remaining portion of the ball. The average temperature gradient in the vicinity of both contacts increases approximately 70 to 100 percent. A higher temperature gradient produces excessive thermal stress locally which may be detrimental to the material integrity. This, however, is the only unfavorable issue for an increase of heat transfer coefficient.
A technique for fabricating uniform thin-wall metallic heat-transfer models and which simulates a Shuttle thermal protection system tile is described. Two 6- by 6- by 2.5-in. tiles were fabricated to obtain local heat transfer rates. The fabrication process is not limited to any particular geometry and results in a seamless thin-wall heat-transfer model which uses a one-wire thermocouple to obtain local cold-wall heat-transfer rates. The tile is relatively fragile because of the brittle nature of the material and the structural weakness of the flat-sided configuration; however, a method was developed and used for repairing a cracked tile.
Local heat transfer coefficients were measured on a smooth and roughened NACA 0012 airfoil. Heat transfer measurements on the 0.533 m chord airfoil were made both in flight on the NASA Lewis Twin Otter Icing Research Aircraft and in the NASA Icing Research Tunnel (IRT). Roughness was obtained by the attachment of uniform 2 mm diameter hemispheres to the airfoil surface in 4 distinct patterns. Flight data were taken for the smooth and roughened airfoil at various Reynolds numbers based on chord in the range 1.24 to 2.50 x 10 (exp 6) and at various angles of attack up to 4 deg. During these flight tests, the free stream velocity turbulence intensity was found to be very low (less than 0.1 percent). Wind tunnel data were acquired in the Reynolds number range 1.20 to 4.25 x 10 (exp t) and at angles of attack from -4 to 8 deg. The turbulence intensity in the IRT was 0.5 to 0.7 percent with the cloud generating sprays off. A direct comparison was made between the results obtained in flight and in the IRT. The higher level of turbulence in the IRT vs. flight had little effect on the heat transfer for the lower Reynolds numbers but caused a moderate increase in heat transfer at the high Reynolds numbers. Roughness generally increased the heat transfer.
Local heat transfer coefficients were measured on a smooth and roughened NACA 0012 airfoil. Heat transfer measurements on the 0.533 m chord airfoil were made both in flight on the NASA Lewis Twin Otter Icing Research Aircraft and in the NASA Lewis Icing Research Tunnel (IRT). Roughness was obtained by the attachment of uniform 2 mm diameter hemispheres to the airfoil surface in 4 distinct patterns. Flight data were taken for the smooth and roughened airfoil at various Reynolds numbers based on chord in the range 1.24 to 2.50 x 10(exp 6) and at various angles of attack up to 4 deg. During these flight tests, the free stream velocity turbulence intensity was found to be very low (less than 0.1 percent). Wind tunnel data were acquired in the Reynolds number range 1.20 to 4.25 x 10(exp 6) and at angles of attack from -4 to 8 deg. The turbulence intensity in the IRT was 0.5 to 0.7 percent with the cloud generating sprays off. A direct comparison was made between the results obtained in flight and in the IRT. The higher level of turbulence in the IRT vs. flight had little effect on the heat transfer for the lower Reynolds numbers but caused a moderate increase in heat transfer at the high Reynolds numbers. Roughness generally increased the heat transfer.
A heat transfer (exchange) composition comprising a halide salt matrix having dispersed therein nanoparticles comprising elemental carbon in the absence of water and surfactants, wherein said halide is fluoride or chloride, wherein the halide salt may be an alkali halide salt (e.g., lithium fluoride, sodium fluoride, potassium fluoride, rubidium fluoride, sodium chloride, potassium chloride, rubidium chloride, and eutectic mixtures thereof) or an alkaline earth halide salt (e.g., fluoride or chloride salt of beryllium, magnesium, calcium, strontium, or barium), and wherein the nanoparticles comprising elemental carbon may be solid or hollow, and wherein the composition may further include nanoparticles comprising a fissile material (e.g., U, Th, or Pu) dispersed within the composition. Molten salt reactors (MSRs) containing these heat transfer compositions in coolant loops in thermal exchange with a reactor core, as well operation of such MSRs, are also described.
Unsteady heat transfer characterization on the combustion surfaces of Rotational Detonation Engines (RDE) is not well understood. It is generally thought that the complex nature of the unsteady, reacting, compressible fluid flow inside the combustion anulus of the RDE causes the convective heat transfer coefficient to be significantly higher than it is in other applications. Empirical models that have been used to analyze this strictly apply to steady flows where dimensionless groups can be employed. The reacting flow fields that are characteristic of RDEs are inherently compressible, three dimensional, unsteady, and turbulent, having properties that change by orders of magnitude throughout the flow field. They will therefore contain multiple length scales and time scales operating everywhere in the flow during all times. Because of this it is not likely that the RDE flow fields will lend themselves to explanation using simple dimensionless parameters. The dimensionless groups have meaning only in situations where length scales and time scales are singular and well defined. In spite of this it may be possible to get a relatively good idea of what the convection heat transfer coefficient is. In this work a numerical study is performed where the inside wall surface temperature distribution in the RDE outer body is systematically changed over a given range that would be characteristic of the start-up flows inside an RDE. For each case, temperature distributions inside the outer containment wall of the RDE was calculated and compared with experimental data. The closet match can then be used to directly calculate the convection heat transfer coefficient on the inside surface of the RDE.