Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Temperature Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Gallium Oxide Heterojunction Diodes for 400 °C High‐Temperature Applications

β ‐Ga 2 O 3 ‐based semiconductor devices are expected to have significantly improved high‐power and high‐temperature performance due to its ultrawide bandgap of close to 5 eV. However, the high‐temperature operation of these ultrawide‐bandgap devices is usually limited by the relatively low 1–2 eV built‐in potential at the Schottky barrier with most high‐work‐function metals. Herein, heterojunction p ‐NiO/n‐ β ‐Ga 2 O 3 diodes fabrication and optimization for high‐temperature device applications are reported, demonstrating a current rectification ratio ( I ON / I OFF ) of more than 10 6 at 410 °C. The NiO heterojunction diode can achieve higher turn‐on ( V ON ) voltage and lower reverse leakage current compared to the Ni‐based Schottky diode fabricated on the same single‐crystal β ‐Ga 2 O 3 substrate, despite charge transport dominated by interfacial recombination. Electrical characterization and device modeling show that these advantages are due to a higher built‐in potential and additional band offset. These results suggest that heterojunction p–n diodes based on β ‐Ga 2 O 3 can significantly improve high‐temperature electronic device and sensor performance.

Sohel, Shahadat H.↗

Multifunctional Nanowire/film Composites based Bi-modular Sensors for In-situ and Real-time High Temperature Gas Detection

This final report to the Department of Energy/National Energy Technology Laboratory for DE-FE0000870 covers the period from 2009 to June, 2013 and summarizes the main research accomplishments, which can be divided in sensing materials innovation, bimodular sensor demonstration, and new understanding and discoveries. As a matter of fact, we have successfully completed all the project tasks in June 1, 2013, and presented the final project review presentation on the 9th of July, 2013. Specifically, the major accomplishments achieved in this project include: 1) Successful development of a new class of high temperature stable gas sensor nanomaterials based on composite nano-array strategy in a 3D or 2D fashion using metal oxides and perovskite nanostructures. 2) Successful demonstration of bimodular nanosensors using 2D nanofibrous film and 3D composite nanowire arrays using electrical resistance mode and electrochemical electromotive force mode. 3) Series of new discoveries and understandings based on the new composite nanostructure platform toward enhancing nanosensor performance in terms of stability, selectivity, sensitivity and mass flux sensing. In this report, we highlight some results toward these accomplishments.

47 OTHER INSTRUMENTATION↗

HEAT Sensor: Harsh Environment Adaptable Thermionic Sensor

This document is the final report for the “HARSH ENVIRONMENT ADAPTABLE THERMIONIC SENSOR” project under NETL’s Crosscutting contract DE-FE0013062. This report addresses sensors that can be made with thermionic thin films along with the required high temperature hermetic packaging process. These sensors can be placed in harsh high temperature environments and potentially be wireless and self-powered.

01 COAL, LIGNITE, AND PEAT↗

Support of the eight-foot high-temperature tunnel modifications project

An ultrasonic level sensor was developed to measure the liquid level in a storage vessel under high pressures, namely up to 6000 psi. The sensor is described. A prototype sensor was installed in the cooling-water storage vessel of the Eight-Foot High-Temperature Tunnel. Plans are being made to install the readout instrument in the control room, so that tunnel operators can monitor the water level during the course of a tunnel run. It was discovered that the sensor will operate at cryogenic temperatures. Consequently, a sensor will be installed in the modified Eight-Foot High-Temperature Tunnel to measure the sound speed of liquid oxygen (LOX) as it is transferred from a storage vessel to the tunnel combustor at pressure of about 3000 psi. The sound speed is known to be a reliable indicator of contamination of LOX by pressurized gaseous nitrogen, which will be used to effect the transfer. Subjecting the sensor to a temperature cycle from room temperature to liquid nitrogen temperature and back again several times revealed no deterioration in sensor performance. The method using this sensor is superior to the original method, which was to bleed samples of LOX from the storage vessel to an independent chamber for measurement of the sound speed.

Hodges, Donald Y.↗

Measurement of atmospheric turbulence strength at high altitude with balloon-borne temperature sensors

A technique to measure a vertical profile of the optical strength of turbulence employs the measurement of a root mean square temperature difference between two microthermal probes carried aloft as part of a balloon payload. Microthermal fluctuations provide a measure for the density fluctuations of turbulence. Examination of recorded profiles of refractive-index structure coefficients reveals a turbulence structure which is organized into multiple, thin groupings of strong turbulence separated by relatively quiescent intervals of variable length.

Bufton, J. L.↗

A diamond-based scanning probe spin sensor operating at low temperature in ultra-high vacuum

We present the design and performance of an ultra-high vacuum (UHV) low temperature scanning probe microscope employing the nitrogen-vacancy color center in diamond as an ultrasensitive magnetic field sensor. Using this center as an atomic-size scanning probe has enabled imaging of nanoscale magnetic fields and single spins under ambient conditions. In this article we describe an experimental setup to operate this sensor in a cryogenic UHV environment. This will extend the applicability to a variety of molecular systems due to the enhanced target spin lifetimes at low temperature and the controlled sample preparation under UHV conditions. The instrument combines a tuning-fork based atomic force microscope (AFM) with a high numeric aperture confocal microscope and the facilities for application of radio-frequency (RF) fields for spin manipulation. We verify a sample temperature of <50 K even for strong laser and RF excitation and demonstrate magnetic resonance imaging with a magnetic AFM tip.

36 MATERIALS SCIENCE↗

Temperature and Pressure Sensors Based on Spin-Allowed Broadband Luminescence of Doped Orthorhombic Perovskite Structures

Systems and methods that are capable of measuring pressure or temperature based on luminescence are discussed herein. These systems and methods are based on spin-allowed broadband luminescence of sensors with orthorhombic perovskite structures of rare earth aluminates doped with chromium or similar transition metals, such as chromium-doped gadolinium aluminate. Luminescence from these sensors can be measured to determine at least one of temperature or pressure, based on either the intense luminescence of these sensors, even at high temperatures, or low temperature techniques discussed herein.

Eldridge, Jeffrey I.↗

Very high temperature silicon on silicon pressure transducers

A silicon on silicon pressure sensor has been developed for use at very high temperatures (1000 F). The design principles used to fabricate the pressure sensor are outlined and results are presented of its high temperature performance.

Kurtz, Anthony D.↗

Research sensors

The LeRC program in research sensors is directed at development of sensors and sensing techniques for research applications on turbine engines and propulsion systems. In general, the sensors are used either to measure to response of an engine component to the imposed environment. Locations of concern are generally within the gas path and, for the most part, are within the hot section of the engine. Since these sensors are used for research testing as opposed to operational use, a sensor lifetime of the order of 50 hr is considered sufficient. The following discussion presents a sample of this work, describing programs to develop a dynamic gas temperature measuring system, total heat flux sensors, a variety of thin-film sensors, and high-temperature strain measuring systems.

Englund, David R.↗

Irradiation Testing of Ultrasonic Transducers

Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of single, small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of existing knowledge of ultrasonic transducer material survivability under irradiation conditions. For this reason, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate promising magnetostrictive and piezoelectric transducer performance in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2 (E> 0.1 MeV). The goal of this research is to characterize magnetostrictive and piezoelectric transducer survivability during irradiation, enabling the development of novel radiation tolerant ultrasonic sensors for use in Material and Test Reactors (MTRs). As such, this test will be an instrumented lead test and real-time transducer performance data will be collected along with temperature and neutron and gamma flux data. The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers.

harsh-environment sensors↗

Measurement of Void Fraction Distribution in Steam-Water Two-Phase Flow in a 44 Bundle at 2 MPa

To contribute to the clarification of the Fukushima Daiichi Accident, JAEA is working on getting instantaneous void fraction distribution data in steam-water two-phase flow in rod bundle geometry under high pressure, high temperature condition, with using Wire Mesh Sensor (WMS) developed at JAEA for high pressure, high temperature condition (Up to 2.8 MPa, 230 deg. C), focusing on the low flow rate condition after the reactor scram. The data is expected to be used in the validation of the detailed two-phase flow codes TPFIT and ACE3D developed at JAEA. The time and space averaged void fraction data is also expected being used in the validation of the drift-flux models implemented in the two fluids codes, such as TRACE code. We are still in the middle of the data analyses and here we only report a part of the results. For the present bundle rod geometry, the void fraction shows easily gathered at the center area surrounded by 4 rods and the void fraction in the sub - channels between two adjacent rods are low. Under the same steam vapor flow rate condition, void faction increase with the decrease of the water flow rate. Under the same water flow rate, the void fraction increases with the increase of the steam vapor flow rate. In recent future, we will perform more experiments under further low water flow rate condition, including stagnation condition, to confirm this changing tendency. In the present experimental range, no effect of pressure on void fraction was observed. A 3-layer WMS, with a vertical distance between the adjacent layers of 1.3 mm, was used to measure the local instantaneous void fraction in this research. By using the correlation coefficient method, we can determine the time delay between the bubble detections from the upper and the lower layer sensors. Then the speed of the bubble, and its length, can be calculated. We are working on the establishment of the databank for the slug-churn bubbles information. (authors)

42 ENGINEERING↗

Fiber optic and laser sensors IX; Proceedings of the Meeting, Boston, MA, Sept. 3-5, 1991

The present volume on fiber-optic and laser sensors discusses industrial applications of fiber-optic sensors, fiber-optic temperature sensors, fiber-optic current sensors, fiber-optic pressure/displacement/vibration sensors, and generic fiber-optic systems. Attention is given to a fiber-sensor design for turbine engines, fiber-optic remote Fourier transform IR spectroscopy, near-IR fiber-optic temperature sensors, and an intensity-type fiber-optic electric current sensor. Topics addressed include fiber-optic magnetic field sensors based on the Faraday effect in new materials, diaphragm size and sensitivity for fiber-optic pressure sensors, a microbend pressure sensor for high-temperature environments, and linear position sensing by light exchange between two lossy waveguides. Also discussed are two-mode elliptical-core fiber sensors for measurement of strain and temperature, a fiber-optic interferometric X-ray dosimeter, fiber-optic interferometric sensors using multimode fibers, and optical fiber sensing of corona discharges.

Depaula, Ramon P.↗

Chemical Gas Sensors for Aeronautic and Space Applications 2

Aeronautic and Space applications require the development of chemical sensors with capabilities beyond those of commercially available sensors. Areas of most interest include launch vehicle safety monitoring emission monitoring and fire detection. This paper discusses the needs of aeronautic and space applications and the point-contact sensor technology being developed to address these needs. The development of these sensor is based on progress two types of technology: 1) Micro-machining and micro-fabrication technology to fabricate miniaturized sensors. 2) The development of high temperature semiconductors, especially silicon carbide. Sensor development for each application involves its own challenges in the fields of materials science and fabrication technology. The number of dual-use commercial applications of this micro-fabricated gas sensor technology make this area of sensor development a field of significant interest.

Hunter, G. W.↗

Chemical Gas Sensors for Aeronautic and Space Applications 2

Aeronautic and space applications require the development of chemical sensors with capabilities beyond those of commercially available sensors. Areas of interest include launch vehicle safety monitoring, emission monitoring, and fire detection. This paper discusses the needs of aeronautic and space applications and the point-contact sensor technology being developed to address these needs. The development of these sensors is based on progress in two types of technology: 1) Micromachining and microfabrication technology to fabricate miniaturized sensors. 2) The development of high temperature semiconductors, especially silicon carbide. Sensor development for each application involves its own challenges in the fields of materials science and fabrication technology. The number of dual-use commercial applications of this microfabricated gas sensor technology make this area of sensor development a field of significant interest.

Hunter, Gary W.↗

Chemical Gas Sensors for Aeronautics and Space Applications III

Aeronautic and space applications require the development of chemical sensors with capabilities beyond those of commercially available sensors. Areas of interest include launch vehicle safety monitoring, emission monitoring, and fire detection. This paper discusses the needs of aeronautic and space applications and the point-contact sensor technology being developed to address these needs. The development of these sensors is based on progress in two types of technology: 1) Micromachining and microfabrication technology to fabricate miniaturized sensors. 2) The development of high temperature semiconductors, especially silicon carbide. Sensor development for each application involves its own challenges in the fields of materials science and fabrication technology. The number of dual-use commercial applications of this microfabricated gas sensor technology make this area of sensor development a field of significant interest.

Hunter, G. W.↗

Absorption spectroscopy based high-speed oxygen concentration measurements at elevated gas temperatures

A sensor built upon tunable diode laser absorption spectroscopy (TDLAS) has been developed for concentration measurements in high-temperature (up to 800 K) gas streams; while the sensor measures gas oxygen and water concentration, temperature and pressure, this work focuses on the challenges and solutions to transient oxygen measurement. A 760-nm diode laser was used to probe a pair of oxygen absorption transitions, and a Herriott cell based multi-pass arrangement was utilized to compensate for the extremely weak oxygen absorption as well as the high gas temperature. This multi-pass arrangement provides a 4297.4-mm absorption path length across a 76.2-mm diameter duct, and an O 2 detection limit ([O 2 ] where SNR=1) of ca. 0.1%. Laboratory validation of the HITRAN spectral parameters of the chosen absorption transitions was performed over a range of high temperatures and oxygen concentrations relevant to engine-exhaust applications. The insensitivity of the Herriott cell arrangement to vibrations and spatial temperature gradients was demonstrated. Conclusions from applications to single- and multi-cylinder engine exhaust are presented and demonstrate the new sensor’s ability to measure fast intra-cycle gas-property transients, and provide insights relevant to advancing internal-combustion-engine technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thin-Film Ceramic Thermocouples Fabricated and Tested

The Sensors and Electronics Technology Branch of the NASA Glenn Research Center is developing thin-film-based sensors for surface measurement in propulsion system research. Thin-film sensors do not require special machining of the components on which they are mounted, and they are considerably thinner than wire- or foil-based sensors. One type of sensor being advanced is the thin-film thermocouple, specifically for applications in high-temperature combustion environments. Ceramics are being demonstrated as having the potential to meet the demands of thin-film thermocouples in advanced aerospace environments. The maximum-use temperature of noble metal thin-film thermocouples, 1500 C (2700 F), may not be adequate for components used in the increasingly harsh conditions of advanced aircraft and next-generation launch vehicles. Ceramic-based thermocouples are known for their high stability and robustness at temperatures exceeding 1500 C, but are typically in the form of bulky rods or probes. As part of ASTP, Glenn's Sensors and Electronics Technology Branch is leading an in-house effort to apply ceramics as thin-film thermocouples for extremely high-temperature applications as part of ASTP. Since the purity of the ceramics is crucial for the stability of the thermocouples, Glenn's Ceramics Branch and Case Western Reserve University are developing high-purity ceramic sputtering targets for fabricating high-temperature sensors. Glenn's Microsystems Fabrication Laboratory, supported by the Akima Corporation, is using these targets to fabricate thermocouple samples for testing. The first of the materials used were chromium silicide (CrSi) and tantalum carbide (TaC). These refractory materials are expected to survive temperatures in excess of 1500 C. Preliminary results indicate that the thermoelectric voltage output of a thin-film CrSi versus TaC thermocouple is 15 times that of the standard type R (platinum-rhodium versus platinum) thermocouple, producing 20 mV with a 200 C temperature gradient. The photograph on the left shows the CrSi-TaC thermocouple in a test fixture at Glenn, and the resulting output signal is shown on the right. The temperature differential across the sample, from the center of the sample inside the oven to the sample mount outside the oven, is measured using a type R thermocouple on the sample.

Wrbanek, John D.↗