Search NASA⌕ Search

SEARCH · Search NASA

Results for “High contrast imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

The incommensurate modulation of tetragonal tungsten bronze quantified by high resolution 4D STEM

Many members of the tetragonal tungsten bronze (TTB) family of oxides display an incommensurate periodic lattice distortion, the nature of which has been the subject of some controversy. Here we present a study of this structural modulation in the relaxor ferroelectric Ba 5 SmSn 3 Nb 7 O 30 (BSSN) by quantitative scanning transmission electron microscopy (STEM). Additionally, we characterize the modulation in BSSN by employing a fast, pixelated direct electron detector to perform high resolution phase contrast STEM imaging of the crystalline lattice. By quantitatively analyzing the images, we visualize the atomic structural correlations present in the material on both the cation and anion sublattices. This analysis reveals the incommensurate structure to have an octahedral tilting pattern and cooperative A2 site cation displacements, analogous to an Ama2 commensurate cell. Finally, we show that the modulation is composed of a structural motif with a period of 3 x $d_{1\bar{1}0}$ and modified by discommensurations, likely arise from frustrated octahedral tilting in the odd-valued periodicity.

Differential phase contrast↗

Single Electron Self-coherence and Its Wave/Particle Duality in the Electron Microscope

Intensities in high-resolution phase-contrast images from electron microscopes build up discretely in time by detecting single electrons. A wave description of pulse-like coherent-inelastic interaction of an electron with matter implies a time-dependent coexistence of coherent partial waves. Their superposition forms a wave package by phase decoherence of 0.5 - 1 radian with Heisenbergs energy uncertainty ΔE H = $\hbar$/2 Δt -1 matching the energy loss ΔE of a coherent-inelastic interaction and sets the interaction time Δt. In these circumstances, the product of Planck's constant and the speed of light hc is given by the product of the expression for temporal coherence λ 2 /Δλ and the energy loss ΔE. Experimentally, the self-coherence length was measured by detecting the energy-dependent localization of scattered, plane matter waves in surface proximity exploiting the Goos–Hänchen shift. Chromatic-aberration Cc-corrected electron microscopy on boron nitride (BN) proves that the coherent crystal illumination and phase contrast are lost if the self-coherence length shrinks below the size of the crystal unit cell at ΔE > 200 eV. Finally, in perspective, the interaction time of any matter wave compares with the lifetime of a virtual particle of any elemental interaction, suggesting the present concept of coherent-inelastic interactions of matter waves might be generalizable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Visible Motion Blur

A method of measuring motion blur is disclosed comprising obtaining a moving edge temporal profile r(sub 1)(k) of an image of a high-contrast moving edge, calculating the masked local contrast m(sub1)(k) for r(sub 1)(k) and the masked local contrast m(sub 2)(k) for an ideal step edge waveform r(sub 2)(k) with the same amplitude as r(sub 1)(k), and calculating the measure or motion blur Psi as a difference function, The masked local contrasts are calculated using a set of convolution kernels scaled to simulate the performance of the human visual system, and Psi is measured in units of just-noticeable differences.

Watson, Andrew B.↗

Self‐gated, dynamic contrast‐enhanced magnetic resonance imaging with compressed‐sensing reconstruction for evaluating endothelial permeability in the aortic root of atherosclerotic mice

High‐risk atherosclerotic plaques are characterized by active inflammation and abundant leaky microvessels. We present a self‐gated, dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI) acquisition with compressed sensing reconstruction and apply it to assess longitudinal changes in endothelial permeability in the aortic root of Apoe −/− atherosclerotic mice during natural disease progression. Twenty‐four, 8‐week‐old, female Apoe −/− mice were divided into four groups (n = 6 each) and imaged with self‐gated DCE‐MRI at 4, 8, 12, and 16 weeks after high‐fat diet initiation, and then euthanized for CD68 immunohistochemistry for macrophages. Eight additional mice were kept on a high‐fat diet and imaged longitudinally at the same time points. Aortic‐root pseudo‐concentration curves were analyzed using a validated piecewise linear model. Contrast agent wash‐in and washout slopes ( b 1 and b 2 ) were measured as surrogates of aortic root endothelial permeability and compared with macrophage density by immunohistochemistry. b 2 , indicating contrast agent washout, was significantly higher in mice kept on an high‐fat diet for longer periods of time ( p = 0.03). Group comparison revealed significant differences between mice on a high‐fat diet for 4 versus 16 weeks ( p = 0.03). Macrophage density also significantly increased with diet duration ( p = 0.009). Spearman correlation between b 2 from DCE‐MRI and macrophage density indicated a weak relationship between the two parameters (r = 0.28, p = 0.20). Validated piecewise linear modeling of the DCE‐MRI data showed that the aortic root contrast agent washout rate is significantly different during disease progression. Further development of this technique from a single‐slice to a 3D acquisition may enable better investigation of the relationship between in vivo imaging of endothelial permeability and atherosclerotic plaques' genetic, molecular, and cellular makeup in this important model of disease.

Calcagno, Claudia↗

A Resolved Near-Infrared Image of the Inner Cavity in the GM Aur Transitional Disk

We present high-contrast H-band polarized intensity (PI) images of the transitional disk around the young solar like star GM Aur. The near-infrared direct imaging of the disk was derived by polarimetric differential imaging using the Subaru 8.2 m Telescope and HiCIAO. An angular resolution and an inner working angle of 0 07 and radius approximately 0 05, respectively, were obtained. We clearly resolved a large inner cavity, with a measured radius of 18+/ 2 au, which is smaller than that of a submillimeter interferometric image (28 au). This discrepancy in the cavity radii at near-infrared and submillimeter wavelengths may be caused by a 34M(sub Jup) planet about 20 au away from the star, near the edge of the cavity. The presence of a near-infrared inner cavity is a strong constraint on hypotheses for inner cavity formation in a transitional disk. A dust filtration mechanism has been proposed to explain the large cavity in the submillimeter image, but our results suggest that this mechanism must be combined with an additional process. We found that the PI slope of the outer disk is significantly different from the intensity slope obtained from HSTNICMOS, and this difference may indicate the grain growth process in the disk.

high-contrast H-band polarized intensity (PI)↗

Hard X-ray and gamma-ray imaging spectroscopy for the next solar maximum

The objectives and principles are described of a single spectroscopic imaging package that can provide effective imaging in the hard X- and gamma-ray ranges. Called the High-Energy Solar Physics (HESP) mission instrument for solar investigation, the device is based on rotating modulation collimators with germanium semiconductor spectrometers. The instrument is planned to incorporate thick modulation plates, and the range of coverage is discussed. The optics permit the coverage of high-contrast hard X-ray images from small- and medium-sized flares with large signal-to-noise ratios. The detectors allow angular resolution of less than 1 arcsec, time resolution of less than 1 arcsec, and spectral resolution of about 1 keV. The HESP package is considered an effective and important instrument for investigating the high-energy solar events of the near-term future efficiently.

Hudson, H. S.↗

X-Ray Diffraction and Imaging Study of Imperfections of Crystallized Lysozyme with Coherent X-Rays

Phase-sensitive x-ray diffraction imaging and high angular-resolution diffraction combined with phase contrast radiographic imaging are employed to characterize defects and perfection of a uniformly grown tetragonal lysozyme crystal in symmetric Laue case. The fill width at half-maximum (FWHM) of a 4 4 0 rocking curve measured from the original crystal is approximately 16.7 arcseconds, and defects, which include point defects, line defects, and microscopic domains, have been clearly observed in the diffraction images of the crystal. The observed line defects carry distinct dislocation features running approximately along the <110> growth front, and they have been found to originate mostly at a central growth area and occasionally at outer growth regions. Individual point defects trapped at a crystal nucleus are resolved in the images of high sensitivity to defects. Slow dehydration has led to the broadening of the 4 4 0 rocking curve by a factor of approximately 2.4. A significant change of the defect structure and configuration with drying has been revealed, which suggests the dehydration induced migration and evolution of dislocations and lattice rearrangements to reduce overall strain energy. The sufficient details of the observed defects shed light upon perfection, nucleation and growth, and properties of protein crystals.

Hu, Zheng-Wei↗

Deep Learning Segmentation of Complex Features in Atomic-Resolution Phase-Contrast Transmission Electron Microscopy Images

Phase-contrast transmission electron microscopy (TEM) is a powerful tool for imaging the local atomic structure of materials. TEM has been used heavily in studies of defect structures of two-dimensional materials such as monolayer graphene due to its high dose efficiency. However, phase-contrast imaging can produce complex nonlinear contrast, even for weakly scattering samples. It is, therefore, difficult to develop fully automated analysis routines for phase-contrast TEM studies using conventional image processing tools. For automated analysis of large sample regions of graphene, one of the key problems is segmentation between the structure of interest and unwanted structures such as surface contaminant layers. In this study, we compare the performance of a conventional Bragg filtering method with a deep learning routine based on the U-Net architecture. We show that the deep learning method is more general, simpler to apply in practice, and produces more accurate and robust results than the conventional algorithm. We provide easily adaptable source code for all results in this paper and discuss potential applications for deep learning in fully automated TEM image analysis.

47 OTHER INSTRUMENTATION↗

Laboratory Testbed Verification of Data Post-Processing Strategies for the WFIRST Coronagraph Instrument

One of the objectives of the WFIRST Coronagraph Instrument is to demonstrate post-processing algorithms for space-based exoplanet imaging data in the regime of very high contrast ratios (< 1E-8). We analyzed two 15-hour time series of laboratory images acquired with prototype coronagraph designs on a vacuum chamber testbed at JPL. These data sets enabled us to test the performance of reference differential imaging (RDI) PSF subtraction as a function of time and Euclidean (L2) speckle pattern distance. Starting from an analytical relationship between speckle pattern stability and classical subtraction gain, we compared the classical subtraction result to those of the KLIP RDI algorithm. In both data sets, KLIP RDI contrast gains are typically 3-4× greater than those of classical subtraction. These results suggest that a diverse reference PSF library will enable a significant gain in sensitivity beyond that suggested by the raw, frame-to-frame speckle pattern stability.

Ygouf, Marie↗

MISR Calibration Issues in High-Contrast Scenes, and Empirical Corrections

We diagnose the potential causes for the Multi-angle Imaging SpectroRadiometer's (MISR) persistent high aerosol optical depth (AOD) bias at low AOD with the aid of coincident MODerate-resolution Imaging Spectroradiometer (MODIS) imagery from NASA's Terra satellite. Internal reflections within the MISR instrument are responsible for a large portion of the high AOD bias in high-contrast scenes, which are especially common as broken-cloud situations over ocean. Discrepancies between MODIS and MISR nadir-viewing near-infrared (NIR) images are used to optimize nine parameters, along with a background reflectance modulation term (that was modeled separately), to represent the observed features. Independent, surface-based AOD measurements from the AErosol RObotic NETwork (AERONET) and the Marine Aerosol Network (MAN) are compared with MISR Research Algorithm (RA) AOD retrievals for 1118 coincidences to validate the corrections when applied to the nadir and off-nadir cameras. Additionally, the calibration coefficients for the red and NIR channels used for MISR over-water aerosol retrievals were reassessed with the RA to be consistent on a camera-by-camera basis. With these corrections, plus the baseline RA corrections applied (except enhanced cloud screening), the median AOD bias in the mid-visible (green) band decreases from 0.010 to 0.002, the RMSE decreases by approx. 10%, and the slope and correlation of the MISR vs. sun photometer Ångström Exponent improves. For AOD558 nm < 0.10 and with additional cloud screening, the median bias for the RA-retrieved AOD in the green band decreases from 0.011 to 0.003, compared to ~ 0.023 for the Standard Algorithm (SA). RMSE decreases by ~ 20% compared to the baseline (uncorrected) RA and by 17-53% compared to the SA. After all corrections and cloud screening are implemented, for AOD558 nm < 0.10, which includes about half the validation data, 68% absolute AOD errors for the RA have dropped to < 0.02 (approx. 0.018).

MISR↗

Measurement of helicon waves with phase contrast imaging on DIII-D – A theoretical feasibility study

A DIII-D high-beta H-mode discharge, with I p = 850 kA, B t = 2.1 T n e = 4 10 19 m –3 , has been designed to validate full wave modeling of helicon waves by optimizing the expected response of the Phase Contrast Imaging diagnostic. Helicon waves have been predicted to have high current drive efficiency off-axis without facing the accessibility issues of lower-hybrid waves. To test these predictions experimentally, DIII-D has recently commissioned a high-power helicon antenna. To confidently predict the behavior of helicon waves in future devices, measurements of their fundamental properties and validation against models will be essential. Phase contrast imaging (PCI) is an absolutely calibrated internal reference interferometer able to measure density fluctuations with radial wavenumbers k R between 1.5 cm –1 and 20 cm –1 . For helicon waves 2 cm –1 < k R < 10 cm –1 is expected, allowing PCI to measure their envelope and wavenumber spectrum. This makes PCI a powerful tool for the validation of state-of-the-art models, like the AORSA full wave code. AORSA is used to compute the density perturbations measured by the PCI with 2D calculations corresponding to 11 different toroidal mode numbers combined to resolve the trajectory of the helicon wave in 3D. This is necessary because the waves travel 120 degrees toroidally from the antenna to the PCI. Here, a cold plasma finite element model (CPFEM) [4] is used to predict propagation through the scrape-off layer. The result of the CPFEM model is connected to AORSA by creating an artificial Gaussian antenna on the last closed flux surface. PCI shows best results for waves with small vertical wavenumbers k z . Modeling the helicon waves for several past DIII-D experiments shows that k z is minimized if the intersection of the helicon and the PCI laser beams occurs in the midplane. For such an optimized scenario the predicted signal level is two orders of magnitude larger than the background density fluctuations arising from broadband turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Finding the lost river gas field - Lineament density analysis in hydrocarbon exploration

A comparative trial analysis of lineament density in 1:500,000 Landsat and 1:48,000 aerial Landsat-simulator images of a gas-field region in West Virginia is presented. The high-contrast, band 4, 5, 7 color composite Landsat image was interpreted independently by two analysts. The slightly different lineament maps were evaluated in terms of lineament-density variation in 10 x 10-km areas, and the resulting areal-variation maps are found to be statistically equivalent. High lineament density is shown to be associated with productive gas wells. Comparison of ground-based substructural contour maps and lineament-density analyses of the Landsat-simulator images reveals good correlation between density maxima or isopleths and substructural features associated with hydrocarbon formations. A hydrocarbon-exploration strategy using both Landsat and aerial images is proposed.

Lang, H. R.↗

Electron image contrast analysis of mosaicity in rutile nanocrystals using direct electron detection

Direct electron detection provides high detective quantum efficiency, significantly improved point spread function and fast read-out which have revolutionized the field of cryogenic electron microscopy. However, these benefits for high-resolution electron microscopy (HREM) are much less exploited, especially for in situ study where major impacts on crystallographic structural studies could be made. By using direct detection in electron counting mode, rutile nanocrystals have been imaged at high temperature inside an environmental transmission electron microscope. The improvements in image contrast are quantified by comparison with a charge-coupled device (CCD) camera and by image matching with simulations using an automated approach based on template matching. Together, these approaches enable a direct measurement of 3D shape and mosaicity (~1°) of a vacuum-reduced TiO 2 nanocrystal about 50 nm in size. Thus, this work demonstrates the possibility of quantitative HREM image analysis based on direct electron detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of Data Acquisition Algorithms on X-ray Phase Contrast Imaging Computed Tomography

X-ray phase contrast imaging (XPCI) is a non-destructive evaluation technique that enables high-contrast detection of low-attenuation materials that are largely transparent in traditional radiography. Extending a grating based Talbot-Lau XPCI system to three- dimensional imaging with computed tomography (CT) imposes two motion requirements: the analyzer grating must translate transverse to the optical axis to capture image sets for XPCI reconstruction, and the sample must rotate to capture angular data for CT reconstruction. The acquisition algorithm choice determines the order of movement and positioning of the two stages. The choice of image acquisition algorithm for XPCI CT is instrumental to collecting high fidelity data for reconstruction. We investigate how data acquisition influences XPCI CT by comparing two simple data acquisition algorithms and determine that capturing a full phase-stepping image set for a CT projection before rotating the sample results in higher quality data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AI-enabled high-resolution scanning coherent diffraction imaging

Ptychographic imaging is a powerful means of imaging beyond the resolution limits of typical x-ray optics. Capturing recovered images from raw ptychographic data, however, requires the solution of an inverse problem, namely, phase retrieval. Phase retrieval algorithms are computationally expensive, which precludes real-time imaging. In this work, we propose PtychoNN, an approach to solve the ptychography data inversion problem based on a deep convolutional neural network. We demonstrate how the proposed method can be used to predict real-space structure and phase at each scan point solely from the corresponding far-field diffraction data. Our results demonstrate the practical application of machine learning to recover high fidelity amplitude and phase contrast images of a real sample hundreds of times faster than current ptychography reconstruction packages. Furthermore, by overcoming the constraints of iterative model-based methods, we can significantly relax sampling constraints on data acquisition while still producing an excellent image of the sample. Besides drastically accelerating acquisition and analysis, this capability has profound implications for the imaging of dose sensitive, dynamic, and extremely voluminous samples.

47 OTHER INSTRUMENTATION↗

Image Quality Indicator for Infrared Inspections

The quality of images generated during an infrared thermal inspection depends on many system variables, settings, and parameters to include the focal length setting of the IR camera lens. If any relevant parameter is incorrect or sub-optimal, the resulting IR images will usually exhibit inherent unsharpness and lack of resolution. Traditional reference standards and image quality indicators (IQIs) are made of representative hardware samples and contain representative flaws of concern. These standards are used to verify that representative flaws can be detected with the current IR system settings. However, these traditional standards do not enable the operator to quantify the quality limitations of the resulting images, i.e. determine the inherent maximum image sensitivity and image resolution. As a result, the operator does not have the ability to optimize the IR inspection system prior to data acquisition. The innovative IQI described here eliminates this limitation and enables the operator to objectively quantify and optimize the relevant variables of the IR inspection system, resulting in enhanced image quality with consistency and repeatability in the inspection application. The IR IQI consists of various copper foil features of known sizes that are printed on a dielectric non-conductive board. The significant difference in thermal conductivity between the two materials ensures that each appears with a distinct grayscale or brightness in the resulting IR image. Therefore, the IR image of the IQI exhibits high contrast between the copper features and the underlying dielectric board, which is required to detect the edges of the various copper features. The copper features consist of individual elements of various shapes and sizes, or of element-pairs of known shapes and sizes and with known spacing between the elements creating the pair. For example, filled copper circles with various diameters can be used as individual elements to quantify the image sensitivity limit. Copper line-pairs of various sizes where the line width is equivalent to the spacing between the lines can be used as element-pairs to quantify the image resolution limit.

Burke, Eric↗

Modulation transfer function measurement technique for small-pixel detectors

A modulation transfer function (MTF) measurement technique suitable for large-format, small-pixel detector characterization has been investigated. A volume interference grating is used as a test image instead of the bar or sine wave target images normally used. This technique permits a high-contrast, large-area, sinusoidal intensity distribution to illuminate the device being tested, avoiding the need to deconvolve raw data with imaging system characteristics. A high-confidence MTF result at spatial frequencies near 200 cycles/mm is obtained. We present results at several visible light wavelengths with a 6.8-micron-pixel CCD. Pixel response functions are derived from the MTF results.

Marchywka, Mike↗