Search NASA⌕ Search

SEARCH · Search NASA

Results for “High vacuum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Tribomaterial factors in space mechanism brake performance

The asbestos/phenolic pads of Shuttle Remote Manipulator System (SRMS) brakes are unsuitable for use in long life space mechanisms because their friction decreases on extended sliding in high vacuum. Dehydration of the material and accumulation of wear debris in the conforming interface of this tribosystem induces the permanent friction changes. Other polymer and some ceramic based materials exhibit similar frictional torque behavior due to the development of minimal contact patches by the interfacial debris. In contrast, high friction occurs when other ceramics form many small contacts throughout fine debris beds. Generating this latter interfacial structure during run-in ensures that the in-vacuo friction remains stable thereafter. Such materials with low wear rates are potential candidates for friction elements in SSRMS and similar mechanisms.

Hawthorne, H. M.↗

NASA Ames' COSmIC Laboratory Astrophysics Facility: Recent Results and Progress

The COSmIC facility was developed at NASA Ames to study interstellar, circumstellar and planetary analogs in the laboratory]. COSmIC stands for "Cosmic Simulation Chamber" and is dedicated to the study of neutral and ionized molecules and nanoparticles under the low temperature and high vacuum conditions that are required to simulate space environments. COSmIC integrates a variety of instruments that allow generating; processing and monitoring simulated space conditions in the laboratory. It is composed of a Pulsed Discharge Nozzle (PDN) expansion that generates a plasma in a free supersonic jet expansion coupled to high-sensitivity, complementary in situ diagnostic tools, used for the detection and characterization of the species present in the expansion: a Cavity Ring Down Spectroscopy (CRDS) and fluorescence spectroscopy systems for photonic detection, and a Reflectron Time-Of-Flight Mass Spectrometer (ReTOF-MS) for mass detection. Recent advances achieved in laboratory astrophysics using COSmIC will be presented, in particular in the domain of the diffuse interstellar bands (DIBs) and the monitoring, in the laboratory, of the formation of dust grains and aerosols from their gasphase molecular precursors in environments as varied as circumstellar outflows and planetary atmospheres. Plans for future laboratory experiments on cosmic molecules and grains in the growing field of laboratory astrophysics (NIR-MIR CRDS, Laser Induced Fluorescence spectra of cosmic molecule analogs and the laser induced incandescence spectra of cosmic grain analogs) will also be addressed as well as the implications of the on-going studies for astronomy.

Laboratory Astrophysics↗

Electron spectroscopy analysis

The Surface Science Laboratories at the University of Alabama in Huntsville (UAH) are equipped with x-ray photoelectron spectroscopy (XPS or ESCA) and Auger electron spectroscopy (AES) facilities. These techniques provide information from the uppermost atomic layers of a sample, and are thus truly surface sensitive. XPS provides both elemental and chemical state information without restriction on the type of material that can be analyzed. The sample is placed into an ultra high vacuum (UHV) chamber and irradiated with x-rays which cause the ejection of photoelectrons from the sample surface. Since x-rays do not normally cause charging problems or beam damage, XPS is applicable to a wide range of samples including metals, polymers, catalysts, and fibers. AES uses a beam of high energy electrons as a surface probe. Following electronic rearrangements within excited atoms by this probe, Auger electrons characteristic of each element present are emitted from the sample. The main advantage of electron induced AES is that the electron beam can be focused down to a small diameter and localized analysis can be carried out. On the rastering of this beam synchronously with a video display using established scanning electron microscopy techniques, physical images and chemical distribution maps of the surface can be produced. Thus very small features, such as electronic circuit elements or corrosion pits in metals, can be investigated. Facilities are available on both XPS and AES instruments for depth-profiling of materials, using a beam of argon ions to sputter away consecutive layers of material to reveal sub-surface (and even semi-bulk) analyses.

Gregory, John C.↗

Retention latch mechanism for the Wake Shield Facility

The Wake Shield Facility (WSF) is a space transportation system (STS) payload that is scheduled for launch on STS-60 in November, 1993. It is being designed, tested and integrated into the STS by Space Industries Inc. for the University of Houston's Space Vacuum Epitaxy Center, a NASA Center for the Commercial Development of Space. The WSF is composed of two main components: a cross-bay carrier and a free-flying experimental platform. The WSF's primary objective is the epitaxial growth of thin films by controlled beam techniques in the ultra-high vacuum that exists in the wake of the free-flyer. The Retention Latch Mechanism (RLM) has been developed to act as the structural interface between the free-flyer and the carrier.

Vendrely, Timothy G.↗

Adhesion and friction of single-crystal diamond in contact with transition metals

An investigation was conducted to examine the adhesion and friction of single-crystal diamond in contact with various transition metals and the nature of metal transfer to diamond. Sliding friction experiments were conducted with diamond in sliding contact with the metals yttrium, titanium, zirconium, vanadium, iron, cobalt, nickel, tungsten, platinum, rhenium and rhodium. All experiments were conducted with loads of 0.05 to 0.3 N, at a sliding velocity of 0.003 m per minute, in a vacuum of 10 to the -8th Pa, at room temperature, and on the (111) plane of diamond with sliding in the 110 line type direction. The results of the investigation indicate that the coefficient of friction for diamond in contact with various metals is related to the relative chemical activity of the metals in high vacuum. The more active the metal, the higher the coefficient of friction. All the metals examined transferred to the surface of diamond in sliding.

Miyoshi, K.↗

Augmenting the Space Environment Complex's Thermal Vacuum Capabilities for Artemis 1 Orion Spacecraft Testing

The Space Environments Complex at Glenn Research Center’s Neil A Armstrong Test Facility (formerly Plum Brook Station) recently successfully completed Artemis 1 thermal vacuum testing. The Space Environments Complex boasts the world’s largest thermal vacuum chamber with a 122-foot tall, 100-foot diameter aluminum assembly vacuum chamber. The fifty-year old chamber has been adapted over its history to conduct several unique test campaigns in a variety of test environments. Artemis 1 Orion spacecraft testing is the most complex test campaign the Space Environments Complex has undergone to date, with temperature limits between -250 F to +300F in a high vacuum with significant requirements for quality data and contamination control of a flight vehicle. This presentation covers the improvements and innovations in the cryoshroud and thermal systems, data acquisition, as well as contamination and cleanliness to accommodate the rigors of a flight vehicle during a six-week thermal vacuum test. Additionally, the presentation covers successes and lessons learned from the testing.

Erin Reed↗

Measurement and Control of Oxygen Partial Pressure in an Electrostatic Levitator

Recently the NASA Marshall Space Flight Center electrostatic levitation (ESL) laboratory has been upgraded to include an oxygen control system. This system allows the oxygen partial pressure within the vacuum chamber to be measured and controlled, at elevated temperatures, theoretically in the range from 10(exp -36) to 10(exp 0) bar. The role of active surface agents in liquid metals is fairly well known; however, published surface tension data typically has large scatter, which has been hypothesized to be caused by the presence of oxygen. The surface tension of metals is affected by even a small amount of adsorption of oxygen. It has even been shown that oxygen partial pressures may need to be as low as 10(exp -24) bar to avoid oxidation. While electrostatic levitation is done under high vacuum, oxide films or dissolved oxygen may have significant effects on materials properties, such as surface tension and viscosity. Therefore, the ability to measure and control the oxygen partial pressure within the chamber is highly desirable. The oxygen control system installed at MSFC contains a potentiometric sensor, which measures the oxygen partial pressure, and an oxygen ion pump. In the pump, a pulse-width modulated electric current is applied to yttrium-stabilized zirconia, resulting in oxygen transfer into or out of the system. Also part of the system is a control unit, which consists of temperature controllers for the sensor and pump, PID-based current loop for the ion pump, and a control algorithm. This system can be used to study the effects of oxygen on the thermophysical properties of metals, ceramics, glasses, and alloys. It can also be used to provide more accurate measurements by processing the samples at very low oxygen partial pressures. The oxygen control system will be explained in more detail and an overview of its use and limitations in an electrostatic levitator will be described. Some preliminary measurements have been made, and the results to date will be provided.

SanSoucie, Michael P.↗

The Mobile Chamber

A document discusses a simulation chamber that represents a shift from the thermal-vacuum chamber stereotype. This innovation, currently in development, combines the capabilities of space simulation chambers, the user-friendliness of modern-day electronics, and the modularity of plug-and-play computing. The Mobile Chamber is a customized test chamber that can be deployed with great ease, and is capable of bringing payloads at temperatures down to 20 K, in high vacuum, and with the desired metrology instruments integrated to the systems control. Flexure plans to lease Mobile Chambers, making them affordable for smaller budgets and available to a larger customer base. A key feature of this design will be an Apple iPad-like user interface that allows someone with minimal training to control the environment inside the chamber, and to simulate the required extreme environments. The feedback of thermal, pressure, and other measurements is delivered in a 3D CAD model of the chamber's payload and support hardware. This GUI will provide the user with a better understanding of the payload than any existing thermal-vacuum system.

Scharfstein, Gregory↗

Implementation Concept of Operation for a Multi-Purpose Cassegrain Solar Concentrator, Micro-Spectrometers, and Electrostatic Neutralizers to Enable In Situ Construction Activities plus Lunar, Planetary, and Deep Space Science Exploration on the Moon

The ability to utilize regolith would support human missions to the Moon and Mars by both stabilizing the surface as well as the use of indigenous resources. Precision landing requirements include surface stabilization to prevent damage or contamination due to regolith projectiles as a result of plume interaction with regolith. The use of indigenous resources rather than hauling materials from Earth appears to be economically a palatable option by converting indigenous resources to usable products. However, such activities have new technical challenges to overcome the issues related to lunar environmental conditions, a wide range of temperature fluctuation, extremely high vacuum, and electrostatically charged fine regolith dusts. For both the regolith sintering and extraction of resources onsite, a Cassegrain solar concentrator was studied for not only sintering lunar regolith into a hardened stabilized surface, but also other multiple applications. This report illustrates a Cassegrain solar concentrator that has multi-functional capabilities for space missions. Proper design and implementation of high-performance lightweight composite materials for the primary mirror of the Cassegrain concentrator can offer multiple capabilities to be performed on the Moon. The multiple applications studied with Cassegrain concentrators are (1) Solar sintering for landing pad and habitats, (2) Harvest of volatiles: H2O, O2, H2, and He-3, (3) Space antenna for telemetry and telecommunication, and (4) Space telescope with 20-meter aperture that exceeds the space telescopes to date in terms of the State-of-Art (SOA) in resolution and aperture diameter. In this study, a key emphasis was placed on the NASA Langley-developed boron nitride nanotube (BNNT) nanocomposite technology which is ideal for the segmented primary mirror structure of the Cassegrain system because it promises a very low coefficient of thermal expansion (CTE) and negligible Poisson ratio. Also, BNNT nanocomposites offer several noticeable benefits, such as light weight, radiation shielding capability, and mechanical strength for structural applications. Additionally, the NASA Langley-developed bullet-like micro-spectrometer and electrostatic power generator were reviewed for mineral mapping applications and electrostatic power generation and dust mitigation from electrostatically charged regolith.

landing pad↗

Effect of additional heat treatment of 2024-T3 on the growth of fatigue crack in air and in vacuum

In order to determine the influence of ductility on the fatigue crack growth rate of aluminum alloys, fatigue tests were carried out on central notched specimens of 2024-T3 and 2024-T8 sheet material. The 2024-T8 material was obtained by an additional heat treatment applied on 2024-T3 (18 hours at 192 C), which increased the static yield strength from 43.6 to 48.9 kgf/sq mm. A change in the ultimate strength was not observed. Fatigue tests were carried out on both materials in humid air and in high vacuum. According to a new crack propagation model, crack extension is supported to be caused by a slip-related process and debonding triggered by the environment. This model predicts an effect of the ductility on the crack growth rate which should be smaller in vacuum than in humid air; however, this was not confirmed. In humid air the crack-growth rate in 2024-T8 was about 2 times faster than in 2024-T3, while in vacuum the ratio was about 2.5. Crack closure measurements gave no indications that crack closure played a significant role in both materials. Some speculative explanations are briefly discussed.

Louwaard, E. P.↗

A facility for the simulation of low orbit atmospheric oxygen bombardment

A molecular beam facility to simulate the space environment of a spacecraft at low orbit was designed with the intent of studying the effect on the properties of optical elements of oxygen atoms impacting at orbital velocity. The four-stage differentially pumped molecular beam facility includes a variety of oxygen atom beam sources which cover a wide range of velocities (1 km/sec to approximately 8 km/sec), in addition to the ultra-clean experimental environmental of an ultra-high vacuum chamber and an optical diagnostic set-up. The primary oxygen atom beam source used to obtain the 8 km/sec O atoms is an arc heated source. It consists of a modified commercially available plasma torch. The modifications include attachments which provide for a nozzle which is used to expand the atomic beam into the vacuum system, and exhaust channels to dispose of excess torch gas. The torch operates in the 'nontransferred' mode of operation, that is the electric arc is confined within the torch. A plasma is formed in helium by a dc arc. A small amount of O2 is injected downstream from the arc where it is thermally dissociated by the hot He into oxygen atoms. The high temperature and isentropic expansion give the oxygen atoms their velocity. Using seeded beam techniques, oxygen atom beams of approximately 3.5 and approximately 1.5 km/sec, respectively, are obtained.

Arnold, G. S.↗

A Study of Space Environment Effect on Highly Thermally Conductive Hybrid Carbon Fiber Polymer Composites

A set of novel highly thermally conductive hybrid carbon fiber (CF) polymer composites has been developed for lightweight thermal radiator applications in space missions. This study investigates the effects of the space environment on these materials following exposure in low-Earth orbit (LEO) during the Materials International Space Station Experiment (MISSE)-17 flight mission, where samples experienced 159 days of combined atomic oxygen (AO), ultraviolet (UV) radiation, high vacuum, space radiation and thermal cycling. Post-flight characterization included weight loss, surface morphology, thermo-optical properties, molecular structures, glass transition temperature, thermal degradation and thermal conductivity analyses. The pyrolytic graphite sheet (PGS) samples exhibited negligible weight loss, stable thermo-optical property, and only minor oxidation signature on the exposed surface. Although AO erosion of the epoxy polymer matrix was evident, carbon nanotube (CNT)-infused PGS/CF epoxy composites retained high thermal emissivity and preserved their high thermal conductivities. These results demonstrate that the novel highly thermally conductive hybrid CF composites possess strong environmental resilience and are promising candidates for lightweight thermal radiators and thermal management components in future space exploration missions.

Space Environment↗

Space simulation ultimate pressure lowered two decades by removal of diffusion pump oil contaminants during operation

The complex problem why large space simulation chambers do not realize the true ultimate vacuum was investigated. Some contaminating factors affecting diffusion pump performance have been identified and some advances in vacuum/distillation/fractionation technology have been achieved which resulted in a two decade or more lower ultimate pressure. Data are presented to show the overall or individual contaminating effect of commonly used phthalate ester plasticizers of 390 to 530 molecular weight on diffusion pump performance. Methods for removing contaminants from diffusion pump silicone oil during operation and reclaiming contaminated oil by high vacuum molecular distillation are described.

Buggele, A. E.↗

Implications of Adhesion Studies for Dust Mitigation on Thermal Control Surfaces

Experiments measuring the adhesion forces under ultrahigh vacuum conditions (10 (exp -10) torr) between a synthetic volcanic glass and commonly used space exploration materials have recently been described. The glass has a chemistry and surface structure typical of the lunar regolith. It was found that Van der Waals forces between the glass and common spacecraft materials was negligible. Charge transfer between the materials was induced by mechanically striking the spacecraft material pin against the glass plate. No measurable adhesion occurred when striking the highly conducting materials, however, on striking insulating dielectric materials the adhesion increased dramatically. This indicates that electrostatic forces dominate over Van der Waals forces under these conditions. The presence of small amounts of surface contaminants was found to lower adhesive forces by at least two orders of magnitude, and perhaps more. Both particle and space exploration material surfaces will be cleaned by the interaction with the solar wind and other energetic processes and stay clean because of the extremely high vacuum (10 (exp -12) torr) so the atomically clean adhesion values are probably the relevant ones for the lunar surface environment. These results are used to interpret the results of dust mitigation technology experiments utilizing textured surfaces, work function matching surfaces and brushing. They have also been used to reinterpret the results of the Apollo 14 Thermal Degradation Samples experiment.

Gaier, James R.↗

Recent Progress in Laboratory Astrophysics and Astrochemistry Achieved with the COSmIC Facility

We describe the characteristics and the capabilities of the laboratory facility, COSmIC, that was developed at NASA Ames to generate, process and analyze interstellar, circumstellar and planetary analogs in the laboratory. COSmIC stands for "Cosmic Simulation Chamber" and is dedicated to the study of neutral and ionized molecules and nanoparticles under the low temperature and high vacuum conditions that are required to simulate various space environments such as diffuse interstellar clouds, circumstellar outflows and planetary atmospheres. COSmIC integrates a variety of state-of-the-art instruments that allow recreating simulated space conditions to generate, process and monitor cosmic analogs in the laboratory. The COSmIC experimental setup is composed of a Pulsed Discharge Nozzle (PDN) expansion, that generates a plasma in the stream of a free supersonic jet expansion, coupled to high-sensitivity, complementary in situ diagnostics: cavity ring down spectroscopy (CRDS) and laser induced fluorescence (LIF) systems for photonic detection, and Reflectron Time-Of-Flight Mass Spectrometer (ReTOF-MS) for mass detection. Recent results obtained using COSmIC will be highlighted. In particular, the progress that has been achieved in the domain of the diffuse interstellar bands (DIBs) and in monitoring, in the laboratory, the formation of circumstellar dust grains and planetary atmosphere aerosols from their gas-phase molecular precursors. Plans for future laboratory experiments on interstellar and planetary molecules and grains will also be addressed, as well as the implications of the studies underway for astronomical observations and past and future space mission data analysis.

Salama, Farid↗

High temperature (1200 C) ceramic-to-metal seal development

Two phases have been completed, of a program whose ultimate objective is the development of an alkali metal resistant, thermal shock resistant, leak-tight, and neutron radiation resistant ceramic-to-metal seal capable of operation at 1200 C for three to five years. The first phase involved the screening of platinum-base, vanadium-base and vanadium-niobium base brazes for the joining of Cb-1Zr or T-111 alloys to high purity alumina. The second phase involved studies of the performance of sealed capsule samples during 5000-hour aging tests at 800, 1000, and 1200 C in high vacuum. Sealed capsules which were made using pure vanadium braze, and were brazed at 1850 C for one minute, survived 64 thermal cycles to 1200 C at the heating/cooling rate of 100 C/minute. Vanadium braze samples survived 5000-hour aging tests at 800, 1000, and 1200 C. One thermally cycled sample survived a subsequent 5000-hour aging period at 1000 C, but another, at 1200 C, did not survive. It was concluded that a pure vanadium braze used to bond high purity alumina to Cb-1Zr alloy is the best of the systems studied, but that additional studies must be performed to establish its service temperature limitations for the desired three to five years' service.

Mckisson, R. L.↗

Rotating Molten Metallic Drops and Related Phenomena: A New Approach to the Surface Tension Measurement

Molten aluminum and tin drops were levitated in a high vacuum by controlled electric fields, and they were systematically rotated by applying by a rotating magnetic field. When the evolution of the drop shape was measured as a function of rotation frequency, it agreed quantitatively well with the Brown and Scriven's theoretical prediction. The normalized rotation frequencies at the bifurcation point agreed with the predicted value 0.559, within 2%. An anomalous phenomenon which totally deviated from the prediction was observed in rotating molten tin drops when they were kept in a high rotation rate for several hours. No anomaly was observed in aluminum drops when they underwent similar condition. It was speculated that under the strong centrifugal force in the drop the tin isotopes must be separating. Since Al-27 is essentially the only naturally abundant isotope in the aluminum drops, the same anomaly is not expected. Based on the shape deformation of a rotating drop, an alternate approach to the surface tension measurement was verified. This new surface tension measurement technique was applied to a glassforming alloy, Zr(41.2)Ti(13.8)Cu(12.5)Ni(10.0)Be(22.5) in its highly viscous states. Also demonstrated in the paper was a use of a molten aluminum drop to verify the Busse's prediction of the influence of the drop rotation on the drop oscillation frequency.

Rhim, Won-Kyu↗

On the distribution of noble gases in Allende - A differential oxidation study

The investigation makes use of an oxidizing technique which is based on methods widely employed in light stable isotope analysis. The utilization of closed-system differential combustion in molecular oxygen in an ultra-high vacuum system on-line with a spectrometer makes it possible to conduct precise abundance and isotopic measurements of all gases released in progressive oxidation and/or thermal outgassing of the host phases. Attention is given to the noble gases mobilized in progressive oxidation of a carbon-rich acid residue and a fine-grained matrix separate. The progressive oxidation of the Allende matrix is discussed. Release occurred over three distinct intervals, characterized by oxidation below 600 C, gas mobilization between 630 and 750 C, and high-temperature diffusive release.

Frick, U.↗