Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hourly Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

AP1000{sup R} nuclear power plant safety overview for spent fuel cooling

The AP1000{sup R} plant is an 1100-MWe class pressurized water reactor with passive safety features and extensive plant simplifications that enhance construction, operation, maintenance, safety and costs. The AP1000 design uses passive features to mitigate design basis accidents. The passive safety systems are designed to function without safety-grade support systems such as AC power, component cooling water, service water or HVAC. Furthermore, these passive features 'fail safe' during a non-LOCA event such that DC power and instrumentation are not required. The AP1000 also has simple, active, defense-in-depth systems to support normal plant operations. These active systems provide the first level of defense against more probable events and they provide investment protection, reduce the demands on the passive features and support the probabilistic risk assessment. The AP1000 passive safety approach allows the plant to achieve and maintain safe shutdown in case of an accident for 72 hours without operator action, meeting the expectations provided in the U.S. Utility Requirement Document and the European Utility Requirements for passive plants. Limited operator actions are required to maintain safe conditions in the spent fuel pool via passive means. In line with the AP1000 approach to safety described above, the AP1000 plant design features multiple, diverse lines of defense to ensure spent fuel cooling can be maintained for design-basis events and beyond design-basis accidents. During normal and abnormal conditions, defense-in-depth and other systems provide highly reliable spent fuel pool cooling. They rely on off-site AC power or the on-site standby diesel generators. For unlikely design basis events with an extended loss of AC power (i.e., station blackout) or loss of heat sink or both, spent fuel cooling can still be provided indefinitely: - Passive systems, requiring minimal or no operator actions, are sufficient for at least 72 hours under all possible pool heat load conditions. - After 3 days, several different means are provided to continue spent fuel cooling using installed plant equipment as well as off-site equipment with built-in connections. Even for beyond design basis accidents with postulated pool damage and multiple failures in the passive safety-related systems and in the defense-in-depth active systems, the AP1000 multiple spent fuel pool spray and fill systems provide additional lines of defense to prevent spent fuel damage. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Packed Bed thermal storage for compact Light water-cooled Small Modular Reactors

Nuclear power plants (NPPs) have less flexibility to follow grid load demand than their natural-gas fueled counterparts. Most of the natural-gas power plants can supply peak-loads by adding more fuel, and thus, can generate far more revenue during those peak hours. On the other hand, use of NPPs for peak load following is quite complex due to technical constraints associated with reactor behavior. These technical challenges include the adequate handling of reactivity swings caused by time-varying fuel and moderator temperatures, a higher fuel-failure probability due to thermal-structural cycling, and spatial variations in xenon concentration. Although there are presently some reactors around the world that are operating with flexible load-following capabilities, such operation is restricted to slowly-varying powers, 2-3 times a day, and only up to 80% of the fuel cycle. Thus, a more convenient and effective method to facilitate load following by NPPs would be to integrate energy storage Authors have previously developed models and performed exergy analysis for integrating liquid type TES with LWRs and SMRs. These exergy based models show that technical feasibility index of integrating thermal energy storage is very high. But most of these previous studies include integration based on existing layout of NPPs with heat exchange between storage Heat Transfer Fluid (HTF) and Reactor Coolant (RC). However, most of the Light Water-cooled Small modular reactor (LW-SMR) based NPP designs can not accommodate additional heat exchange equipment. Although power production is only reduced to 1/20 scale, the containment volume in thus NuScale LW-SMR is reduced to {approx} 1/170 scale. As steam is the secondary or working fluid which exits out of the reactor containment in LW-SMRs, the simplest and most practical way to integrate thermal storage with LW-SMRs is to directly store the energy from steam. Indirect heat exchange between steam and another heat transfer fluid during the storage process, and then heat recovery again via indirect heat exchange is inefficient process due to heat transfer resistance. This inefficiency is due to what is called as 'Pinch point' which occurs whenever there is indirect heat transfer between two media where one undergoes phase change and other undergoes change in sensible heat. Another existing popular option is to use a steam accumulator which stores dry or wet steam directly inside the pressure vessels, however, due to large volumetric requirements it is not a viable option. This work proposes a new method of integrating packed bed TES systems with LW-SMRs, where steam produced in the secondary side of LW-SMRs can be injected into the packed bed of inert particles with sufficient thermal conductivity and capacity to efficiently store energy with high energy density. The changes in the load demand will not effect the LWSMR operation and the excess steam will be diverted to TES. When the demand increases this stored energy in hot packed beds can be recovered by injecting cold pressurized water. Although there are some existing packed bed TES designs and models which consider steam as HTFs, these models have not been extended for wide range of process parameters important for this integration. Authors have previously developed a packed bed thermal model for steam injection and validated it using experimental data. This thermal model is extended to assess behavior of packed bed thermal energy storage (TES) system under storage and recovery cycles. Steam is the only heat transfer fluid (HTF) which exits the reactor vessel, so any application such as process heat or TES integration should be evaluated with steam as process fluid. This project will develop a process system integration model of LW-SMR with packed bed type TES using steam as HTF. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Machine Learning Approach for Hourly Traffic Prediction Used in EV-Charging Sites

Reliable forecasting of hourly traffic volumes on highways is critical for planning and operating electric-vehicle charging infrastructure without overloading the grid. In this work, we develop and evaluate a station-specific machine-learning approach based on NeuralProphet, enhanced with conditional seasonality to better distinguish weekday, weekend, and holiday patterns. For each station, the model automatically retrieves the same calendar day from the prior years as an AR-Net initialization, fits trend and Fourier-based seasonality components, and then applies short-term auto-regressive corrections. We train and test on 2021 and 2022 TMAS data, respectively, and validate performance over the whole year. We chose to demonstrate how the model performs on a typical weekday (3/15/2022), weekend (3/27/2022), and a special holiday (12/25/2022). Our results yield MAPE of 7.4%, 23.6%, and 32.0%, respectively. Over the entire year 2022, the overall MAPE was 17%. This demonstrates that station-specific models with conditional seasonality can achieve accurate, scalable hourly forecasts for EV-charging load planning.

99 - GENERAL AND MISCELLANEOUS↗

Effect of residual stresses induced by prestressing on rolling element fatigue life

A mechanical prestress cycle suitable to induce compressive stress beneath the surface of the inner race of radially loaded 207-size bearings was determined. Compressive residual stress in excess 0.69 x 10 to the 9th power N/sq m (100,000 psi), as measured by X-ray diffraction, were induced at the depth of maximum shearing stress. The prestress cycle consisted of running the bearings for 25 hours at 2750 rpm at a radial load which produced a maximum Hertz stress of 3.3 x 10 to the 9th power N/sq m (480,000 psi) at the contact of the inner race and the heaviest loaded ball. Bearings subjected to this prestress cycle and subsequently fatigue tested gave a 10 percent fatigue life greater than twice that of a group of baseline bearings.

Parker, R. J.↗

Quantifying Load Uncertainty Using Real Smart Meter Data

As we get closer to customers in distribution systems, load stochasticity increases. In the past, due to lack of real-time data, the comprehensive knowledge of load behavior was limited, and simplistic assumptions had to be made for distribution system modeling and analysis, especially in the processes of network design and expansion. With the deployment of Advanced Metering Infrastructure (AMI), ample real-time smart meter data has become available to utilities. In this paper, using real hourly smart meter data, we have quantified load uncertainty in terms of average, maximum and maximum noncoincident demands on a daily basis, as well as load factor and diversity factor. These uncertainty metrics are examined for individual residential, commercial and industrial customers, as well as distribution transformers serving residential customers. This paper provides a benchmark on load uncertainty quantification for practicing engineers and researchers.

Bu, Fankun↗

The Effect of Inverter Loading Ratio on Energy Estimate Bias: Preprint

Subhourly effects, particularly variability in solar irradiance, can lead to underestimation of inverter clipping losses and overestimation of energy in hourly photovoltaic system performance models, particularly for systems with high inverter loading ratios. Direct simulation of this error can be complicated by factors such as the representation of spatial and temporal variability in hourly weather data and transient system conditions. In this work we take an alternative approach using real system power measurements to show that energy predictions from typical industry models suffer from a bias that increases with inverter loading ratio. We also show that this loading ratio-dependent bias is strongly correlated with an empirical subhourly inverter clipping bias derived from real power plant data. Finally, we show that this bias is not necessarily specific to any one model or weather dataset by recreating similar biases with alternatives of each.

clipping↗

Effects of microgravity on osteoblast growth

Studies from space flights over the past two decades have demonstrated that basic physiological changes occur in humans during space flight. These changes include cephalic fluid shifts, loss of fluid and electrolytes, loss of muscle mass, space motion sickness, anemia, reduced immune response, and loss of calcium and mineralized bone. The cause of most of these manifestations is not known and until recently, the general approach was to investigate general systemic changes, not basic cellular responses to microgravity. Recently analyzed data from the 1973-1974 Skylabs disclose that there is a rise in the systemic hormone, cortisol, which may play a role in bone loss in flight. In two flights where bone growth was measured (Skylabs 3 and 4), the crew members had a significant loss of calcium accompanied by a rise in 24 hour urinary cortisol during the entire flight period. In ground-based work on osteoblasts, we have demonstrated that equivalent amounts of glucocorticoids can inhibit osteoblast cell growth. In addition, this laboratory has recently studied gene growth and activation of mouse osteoblasts (MC3T3-E1) during spaceflight. Osteoblast cells were grown on glass coverslips, loaded in the Biorack plunger boxes 18 hours before launch and activated 19 hours after launch in the Biorack incubator under microgravity conditions. The osteoblasts were launched in a serum deprived state, activated and collected in microgravity. Samples were collected at 29 hours after sera activation (0-g, n=4; 1-g, n=4). The osteoblasts were examined for changes in gene expression and cell morphology. Approximately one day after growth activation, remarkable differences were observed in gene expression in 0-g and 1-g flight samples. The 0-g activated cells had increased c-fos mRNA when compared to flight 1-g controls. The message of immediate early growth gene, cox-2 was decreased in the microgravity activated cells when compared to ground or 1-g flight controls. Cox-1 was not detected in any of the samples. There were no significant differences in the expression of actin mRNA between the 0-g and 1-g samples. These data indicate that quiescent osteoblasts are slower to enter the cell cycle in microgravity, suggesting that the force of gravity itself may be a significant factor in bone loss in spaceflight. Preliminary data from our STS 76 flight experiment support our hypothesis that a basic biological response occurs at the tissue, cellular, and molecular level in 0-g. Here we examine ground-based and space flown data on osteoblast growth in ground-based experiments mimicking space flight conditions and in microgravity to simulate lack of gravity stress to help us understand the mechanism of bone loss by experiments.

NASA Experiment Number 9403056↗

An ICA-Based HVAC Load Disaggregation Method Using Smart Meter Data

This paper presents an independent component analysis (ICA) based unsupervised-learning method for heat, ventilation, and air-conditioning (HVAC) load disaggregation using row-resolution (i.e., 15 minutes) smart meter data. We first demonstrate that the electricity consumption profiles on mild-temperature days can be used to approximate the base load on hot days. A residual load profile can then be calculated by subtracting the mild-day load profile from the hot-day load profile. The residual load profiles are processed using ICA for HVAC load extraction. An optimization-based algorithm is proposed for post-adjustment of the ICA results, considering two bounding factors for enhancing the robustness of the ICA algorithm. First, we use the hourly HVAC energy bounds computed from the relationship between HVAC load and temperature to remove unrealistic HVAC load spikes. Second, we exploit the dependency between the daily nocturnal and diurnal loads extracted from historical meter data to smooth the base load profile. Pecan Street data with sub-metered HVAC data were used to test and verify the proposed methods. Simulation results demonstrated that the proposed method is computationally efficient and robust across multiple customers.

Kim, Hyeonjin↗

Substorm recurrence during steady and variable solar wind driving: Evidence for a normal mode in the unloading dynamics of the magnetosphere

Farrugia et al (1993) have recently studied substorm activity driven by the passage of an interplanetary magnetic cloud during which the interplanetary magnetic field turned southward for approximately 18 hours. It was shown that both the epsilon and the VB(sub s) parameters varied slowly on the timescale of a substorm but changed considerably over the interval as a whole. The substorm occurrence rate did not reflect the variation in magnetospheric energy loading rate as measured by these parameters but, rather, remained roughly constant with a 50-min average period. Klimas et al. (1992) showed that the Faraday loop analog model of geomagnetic activity predicts this single unloading rate under various constant loading rates. However, various model parameters were adjusted to yield a 1-hour unloading period in agreement with the Bargatze et al. (1985) linear prediction filters and in approximate agreement with the Farrugia et al. (1993) results. It has since been found necessary to add a slow relaxation mechanism to the Faraday loop model to allow for its approach to a ground state during long periods of inactivity. It is proposed that the relaxation mechanism is provided by slow convection of magnetic flux out of the magnetotail to the dayside magnetosphere. In addition, a rudimentary representation of magnetotail-ionosphere coupling has been added to enable comparison of model output to measured AL. The present study is of the modified Faraday loop model response to solar wind input from the Bargatze et al. data set with comparison of its output to concurrent AL. This study has removed the degree of freedom in parameter choice that had earlier allowed adjustments toward the 1-hour unloading period and has, instead, yielded the 1-hour unloading period under various constant loading rates. It is demonstrated that the second peak of the bimodal Bargatze et al. linear prediction filters at approximately equal 1-hour lag and the approximately constant substorm recurrence rate observed by Farrugia et al. can be interpreted as both being due to the existence of a normal unloading recurrence period in the dynamics of the magnetosphere.

Klimas, A. J.↗

Capabilities and Limitations of Space-Borne Passive Remote Sensing of Dust

Atmospheric dust particles have significant effects on the climate and the environment and despite notable recent advances in modeling and observation, wind-blown dust radiative effects remain poorly quantified in both magnitude and sign [IPCC, 2001]. To address this issue, many scientists are using passive satellite observations to study dust properties and to constrain emission/transport models, because the information provided is both time-resolved and global in coverage. In order to assess the effects of individual dust outbreaks on atmospheric radiation and circulation, relatively high temporal resolution (of the order of hours or days) is required in the observational data. Data should also be available over large geographical areas, as dust clouds may cover hundreds of thousands of square kilometers and will exhibit significant spatial variation in their vertical structure, composition and optical properties, both between and within dust events. Spatial and temporal data continuity is necessary if the large-scale impact of dust loading on climate over periods ranging from hours to months is to be assessed.

Kalashnikova, Olga↗

Identifying Challenging Operating Hours for Solar Intergration in the NV Energy System

Abstract-- In this paper, the ability of the Nevada (NV) Energy generation fleet to meet its system balancing requirements under different solar energy penetration scenarios is studied. System balancing requirements include capacity, ramp rate, and ramp duration requirements for load following and regulation. If, during some operating hours, system capability is insufficient to meet these requirements, there is certain probability that the balancing authority’s control and reliability performance can be compromised. These operating hours are considered as “challenging” hours. Five different solar energy integration scenarios have been studied. Simulations have shown that the NV Energy system will be potentially able to accommodate up to 942 MW of solar photovoltaic (PV) generation. However, the existing generation scheduling procedure should be adjusted to make it happen. Fast-responsive peaker units need to be used more frequently to meet the increasing ramping requirements. Thus, the NV Energy system operational cost can increase. Index Terms—Solar Generation, Renewables Integration, Balancing Process, Load Following, Regulation.

capacity↗

Characterization of Ceramic Matrix Composite Fasteners Exposed in a Combustion Liner Rig Test

Combustion tests on SiC/SiC CMC (Ceramic Matrix Composite) components were performed in an aircraft combustion environment using the Rich-burn, Quick-quench, Lean-burn (RQL) sector rig. SiC/SiC fasteners were used to attach several of these components to the metallic rig structure. The effect of combustion exposure on the fastener material was characterized via microstructural examination. Fasteners were also destructively tested, after combustion exposure, and the failure loads of fasteners exposed in the sector rig were compared to those of as-manufactured fasteners. Combustion exposure reduced the fastener failure load by 50% relative to the as-manufactured fasteners for exposure times ranging from 50 to 260 hours. The fasteners exposed in the combustion environment demonstrated failure loads that varied with failure mode. Fasteners that had the highest average failure load, failed in the same manner as the unexposed fasteners.

Verrilli, Michael J.↗

Use of Residential Smart Appliances for Peak-Load Shifting and Spinning Reserves Cost/Benefit Analysis

In this report, we present the results of an analytical cost/benefit study of residential smart appliances from a utility/grid perspective in support of a joint stakeholder petition to the ENERGY STAR program within the Environmental Protection Agency (EPA) and Department of Energy (DOE). The goal of the petition is in part to provide appliance manufacturers incentives to hasten the production of smart appliances. The underlying hypothesis is that smart appliances can play a critical role in addressing some of the societal challenges, such as anthropogenic global warming, associated with increased electricity demand, and facilitate increased penetration of renewable sources of power. The appliances we consider include refrigerator/freezers, clothes washers, clothes dryers, room air-conditioners, and dishwashers. The petition requests the recognition that providing an appliance with smart grid capability, i.e., products that meet the definition of a smart appliance, is at least equivalent to a corresponding five percent in operational machine efficiencies. It is then expected that given sufficient incentives and value propositions, and suitable automation capabilities built into smart appliances, residential consumers will be adopting these smart appliances and will be willing participants in addressing the aforementioned societal challenges by more effectively managing their home electricity consumption. The analytical model we utilize in our cost/benefit analysis consists of a set of user-definable assumptions such as the definition of on-peak (hours of day, days of week, months of year), the expected percentage of normal consumer electricity consumption (also referred to as appliance loads) that can shifted from peak hours to off-peak hours, the average power rating of each appliance, etc. Based on these assumptions, we then formulate what the wholesale grid operating-cost savings, or benefits, would be if the smart capabilities of appliances were invoked, and some percentage of appliance loads were shifted away from peak hours to run during off-peak hours, and appliance loads served power-system balancing needs such as spinning reserves that would otherwise have to be provided by generators. The rationale is that appliance loads can be curtailed for about ten minutes or less in response to a grid contingency without any diminution in the quality of service to the consumer. We then estimate the wholesale grid operating-cost savings based on historical wholesale-market clearing prices (location marginal and spinning reserve) from major wholesale power markets in the United States. The savings derived from the smart grid capabilities of an appliance are then compared to the savings derived from a five percent increase in traditional operational machine efficiencies, referred to as cost in this report, to determine whether the savings in grid operating costs (benefits) are at least as high as or higher than the operational machine efficiency credit (cost).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Satellite control of electric power distribution

An L-band frequencies satellite link providing the medium for direct control of electrical loads at individual customer sites from remote central locations is described. All loads supplied under interruptible-service contracts are likely condidates for such control, and they can be cycled or switched off to reduce system loads. For every kW of load eliminated or deferred to off-peak hours, the power company reduces its need for additional generating capacity. In addition, the satellite could switch meter registers so that their readings automatically reflected the time of consumption. The system would perform load-shedding operations during emergencies, disconnecting large blocks of load according to predetermined priorities. Among the distribution operations conducted by the satellite in real time would be: load reconfiguration, voltage regulation, fault isolation, and capacitor and feeder load control.

Bergen, L.↗

In-Flight Microbial Monitor

Previous research has shown that potential human pathogens have been detected on the International Space Station (ISS). New microorganisms are introduced with every exchange of crew and cargo. Microorganisms introduced to the ISS are readily transferred between crew and subsystems (i.e., ECLSS, environmental control and life support systems). Current microbial characterization methods require a culture-based enrichment of microorganisms and at least a 48-hour incubation time. This increases the microbial load while detecting only a limited number of microorganisms. The culture-based method detects approximately 1-10% of the total organisms present and provides no identification. To identify and enumerate ISS samples requires that the microbes be returned to Earth for complete analysis. Therefore, a more expedient, low-cost, inflight method of microbial detection, identification, and enumeration is needed. The RAZOR EX, a ruggedized, commercial off the shelf, real-time PCR field instrument was tested for its ability to detect microorganisms at low concentrations within one hour. Escherichia coli, Salmonella enterica Typhimurium, and Pseudomonas aeruginosa were detected at low levels using real-time DNA amplification. Total heterotrophic counts could also be detected using a 16S gene marker that can identify up to 98% of all bacteria. To reflect viable cells found in the samples, RNA was also detectable using a modified, single-step reverse transcription reaction.

Technology Portfolio System↗

Inflight Microbial Monitoring-An Alternative Method to Culture Based Detection Currently Used on International Space Station

Previous research has shown that microorganisms and potential human pathogens have been detected on the International Space Station (ISS). The potential to introduce new microorganisms occurs with every exchange of crew or addition of equipment or supplies. Previous research has shown that microorganisms introduced to the ISS are readily transferred between crew and subsystems and back (i.e. ECLSS, environmental control and life support systems). Current microbial characterization methods require enrichment of microorganisms and a 48-hour incubation time. This increases the microbial load while detecting a limited number of microorganisms. The culture based method detects approximately 1-10% of the total organisms present and provides no identification, To identify and enumerate ISS samples requires that samples to be returned to Earth for complete analysis. Therefore, a more expedient, low-cost, in-flight method of microbial detection, identification, and enumeration is warranted. The RAZOR EX, a ruggedized, commercial off the shelf, real-time PCR field instrument was tested for its ability to detect microorganism at low concentrations within one hour. Escherichia coli, Salmonella enterica Typhimurium, and Pseudomonas aeruginosa were detected at low levels using real-time DNA amplification. Total heterotrophic counts could also be detected using a 16S gene marker that can identify up to 98% of all bacteria. To reflect viable cells found in the samples, RNA was also detectable using a modified, single-step reverse transcription reaction.

Inflight Microbial↗

Inflight Microbial Monitoring- An Alternative Method to Culture Based Detection Currently Used on the International Space Station

Previous research has shown that potentially destructive microorganisms and human pathogens have been detected on the International Space Station (ISS). The likelihood of introducing new microorganisms occurs with every exchange of crew or addition of equipment or supplies. Microorganisms introduced to the ISS are readily transferred between crew and subsystems (i.e. ECLSS, environmental control and life support systems). Current microbial characterization methods require enrichment of microorganisms and at least a 48-hour incubation time. This increases the microbial load while detecting only a limited number of the total microorganisms. The culture based method detects approximately 1-10% of the total organisms present and provides no identification. To identify and enumerate ISS microbes requires that samples be returned to Earth for complete analysis. Therefore, a more expedient, low-cost, in-flight method of microbial detection, identification, and enumeration is warranted. The RAZOR EX, a ruggedized, commercial off the shelf, real-time PCR field instrument was tested for its ability to detect microorganisms at low concentrations within one hour. Escherichia coli, Salmonella enterica Typhimurium, and Pseudomonas aeruginosa were detected at low levels using real-time DNA amplification. Total heterotrophic counts could also be detected using a 16S gene marker that can identify up to 98% of all bacteria. To reflect viable cells found in the samples, RNA was also detectable using a modified, single-step reverse transcription reaction.

Inflight Microbial↗

Advanced waste form and Melter development for treatment of troublesome high-level wastes

A number of waste components in US defense high level radioactive wastes (HLW) have proven challenging for current Joule heated ceramic melter (JHCM) operations and have limited the ability to increase waste loadings beyond already realized levels. Many of these “troublesome" waste species cause crystallization in the glass melt that can negatively impact product quality or have a deleterious effect on melter processing. Recent efforts at US Department of Energy laboratories have focused on understanding crystallization behavior within HLW glass melts and investigating approaches to mitigate the impacts of crystallization so that increases in waste loading can be realized. Advanced glass formulations have been developed to highlight the unique benefits of next-generation melter technologies such as the Cold Crucible Induction Melter (CCIM). Crystal-tolerant HLW glasses have been investigated to allow sparingly soluble components such as chromium to crystallize in the melter but pass out of the melter before accumulating.The Hanford site AZ-101 tank waste composition represents a waste group that is waste loading limited primarily due to high concentrations of Fe 2 O 3 (also with high Al 2 O 3 concentrations). Systematic glass formulation development utilizing slightly higher process temperatures and higher tolerance to spinel crystals demonstrated that an increase in waste loading of more than 20% could be achieved for this waste composition, and by extension higher loadings for wastes in the same group. An extended duration CCIM melter test was conducted on an AZ-101 waste simulant using the CCIM platform at the Idaho National Laboratory (INL). The melter was continually operated for approximately 80 hours demonstrating that the AZ-101 high waste loading glass composition could be readily processed using the CCIM technology. The resulting glass was close to the targeted composition and exhibited excellent durability in both the as poured state and after being slowly cooled according to the canister centerline cooling (CCC) profile. Glass formulation development was also completed on other Hanford tank wastes that were identified to further challenge waste loading due to the presence of appreciable quantities (>750 g) of plutonium in the waste tanks. In addition to containing appreciable Pu quantities, the C-102 waste tank and the 244-TX waste tank contain high concentrations of aluminum and iron, respectively that will further challenge vitrification processing. Glass formulation testing also demonstrated that high waste loadings could be achieved with these tank compositions using the attributes afforded by the CCIM technology.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗