Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENT ORIENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Overview of the PHENIX Longitudinal and Transverse Spin Physics Program

The PHENIX experiment uses polarized p+p collisions at RHIC to explore the spin structure of the proton. The p+p collisions, while complementary to deep inelastic lepton scattering experiments, offer distinct advantages for the determination of the helicity preferences of gluons, the flavor-dependence of sea antiquark polarizations, and parton transverse motion or spin orientation preferences inside polarized protons. The PHENIX experiment has been measuring the double longitudinal spin asymmetry of several inclusive probes to understand the gluon polarization in the allowed kinematic range. In addition, PHENIX experiment also has been studying the single spin asymmetries with a variety of final state particles in different kinematic regimes to shed light on the transverse spin structure. A brief overview is given of results to date and planned future directions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multi-Axis Accelerometer Calibration System

A low-cost, portable, and simplified system has been developed that is suitable for in-situ calibration and/or evaluation of multi-axis inertial measurement instruments. This system overcomes facility restrictions and maintains or improves the calibration quality for users of accelerometer-based instruments with applications in avionics, experimental wind tunnel research, and force balance calibration applications. The apparatus quickly and easily positions a multi-axis accelerometer system into a precisely known orientation suitable for in-situ quality checks and calibration. In addition, the system incorporates powerful and sophisticated statistical methods, known as response surface methodology and statistical quality control. These methods improve calibration quality, reduce calibration time, and allow for increased calibration frequency, which enables the monitoring of instrument stability over time.

Finley, Tom↗

Polarimetric calibration of the Multi-Angle Imager for Aerosols (MAIA)

NASA’s Multi-Angle Imager for Aerosols (MAIA) mission, under development at the Jet Propulsion Laboratory, is designed to study the adverse health effects of different types of particulate air pollution. Planned for launch in 2023 for a 3-year mission, the MAIA satellite instrument will focus on a selected set of metropolitan target areas, where air quality monitors and health data are available. Aerosol concentration and speciation are inferred from multi-angle measurements of backscattered sunlight in 14 spectral bands from 350-2200 nm, with bands near 442, 645 and 1040 nm measuring the degree (DoLP) and angle of linear polarization (AoLP) in addition to radiance. The pushbroom camera has a ~240-km cross-track field of view with a nadir resolution of ~200 m, and is mounted onto a biaxial gimbal to provide along-track view angles within ±60°, to extend the field of regard to ±48°, and to view the instrument’s onboard calibrator (OBC) and dark target. The OBC consists of a sunlit transmissive diffuser, followed by 12 polarizers at different orientations. MAIA’s polarimetry is implemented using miniature wire grid polarizers on the focal plane array, and dual photoelastic modulators (PEMs) and achromatic quarter-wave plates to rapidly rotate the polarization. The resulting ~26-Hz intensity modulation encodes the linearly polarized and total radiance in each pixel, leaving the DoLP and AoLP insensitive to gain calibration. We report on the polarimetric calibration of the MAIA camera using a vacuum-compatible polarization state generator, consisting of a 1600W Xenon lamp, 12-inch integrating sphere, and rotating high-extinction polarizer. Mueller-matrix-based calibration coefficients for each detector pixel are derived from measurements at multiple polarizer angles, and are used to correct the measurements for instrumental polarization aberrations. Prior to flight, the calibrated MAIA camera is panned across the OBC to characterize its output, using uniform illumination with an irradiance similar to the Sun.

Werne, Thomas↗

A Laser Interferometric Miniature Sensor

This is the second year of a Phase II Small Business Innovation Research (SBIR) contract geared towards the development of a new seismic sensor. Ground-based seismic monitoring systems have proven to be very capable in identifying nuclear tests, and can provide somewhat precise information on the location and yield of the explosive device. Making these measurements, however, currently requires very expensive and bulky seismometers that are difficult to deploy in places where they are most needed. A high performance, compact device can enable rapid deployment of large scale arrays, which can in turn be used to provide higher quality data during times of critical need. The use of a laser interferometer-based device has shown considerable promise, while also presenting significant challenges. The greatest strength of this optical readout technique is the ability to decouple the mechanical design from the transducer, thus enabling a miniaturized design that is not accessible with conventional sensing techniques. However, the nonlinearity in the optical response must be accounted for in the sensor output. Previously, we had proposed using a force-feedback approach to position the sensor at a point of maximum linearity. However, it can be shown that the combined nonlinearities of the optical response and the force-feedback curve necessarily results in a significant amount of unwanted noise at low frequencies. Having realized this, we have developed a new approach that eliminates force feedback, allowing the proof mass to move freely at all times. This takes advantage of some advanced optical spatial filtering that was developed at Symphony Acoustics for other types of sensors, and was recently adapted to this work. After processing the signals in real time, the digital output of the device is intrinsically linear, and the sensor can operate at any orientation with the same level of resolution, while instantly adapting to significant changes in orientation. Ultimately, we expect the dynamic range to be up to 180 dB. Currently, we have observed the noise floor in a 0.1 Hz to 10 Hz bandwidth to be near -160 dB/Hz relative to 1 m2/s4. To meet the objectives of this program, we are finalizing the design of a 3 axis sensor for shallow borehole deployments, with a diameter of 40 mm and a length a 150 mm.

47 OTHER INSTRUMENTATION↗

Modern Material Analysis Instruments Add a New Dimension to Materials Characterization and Failure Analysis

Modern analytical tools can yield invaluable results during materials characterization and failure analysis. Scanning electron microscopes (SEMs) provide significant analytical capabilities, including angstrom-level resolution. These systems can be equipped with a silicon drift detector (SDD) for very fast yet precise analytical mapping of phases, as well as electron back-scattered diffraction (EBSD) units to map grain orientations, chambers that admit large samples, variable pressure for wet samples, and quantitative analysis software to examine phases. Advanced solid-state electronics have also improved surface and bulk analysis instruments: Secondary ion mass spectroscopy (SIMS) can quantitatively determine and map light elements such as hydrogen, lithium, and boron - with their isotopes. Its high sensitivity detects impurities at parts per billion (ppb) levels. X-ray photo-electron spectroscopy (XPS) can determine oxidation states of elements, as well as identifying polymers and measuring film thicknesses on coated composites. This technique is also known as electron spectroscopy for chemical analysis (ESCA). Scanning Auger electron spectroscopy (SAM) combines surface sensitivity, spatial lateral resolution (10 nm), and depth profiling capabilities to describe elemental compositions of near and below surface regions down to the chemical state of an atom.

Panda, Binayak↗

Performance of a beam-multiplexing diamond crystal monochromator at the Linac Coherent Light Source

A double-crystal diamond monochromator was recently implemented at the Linac Coherent Light Source. It enables splitting pulses generated by the free electron laser in the hard x-ray regime and thus allows the simultaneous operations of two instruments. Both monochromator crystals are High-Pressure High-Temperature grown type-IIa diamond crystal plates with the (111) orientation. The first crystal has a thickness of ∼100 μm to allow high reflectivity within the Bragg bandwidth and good transmission for the other wavelengths for downstream use. The second crystal is about 300 μm thick and makes the exit beam of the monochromator parallel to the incoming beam with an offset of 600 mm. Here we present details on the monochromator design and its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CO{sub 2} laser-based dispersion interferometer utilizing orientation-patterned gallium arsenide for plasma density measurements

A dispersion interferometer based on the second-harmonic generation of a carbon dioxide laser in orientation-patterned gallium arsenide has been developed for measuring electron density in plasmas. The interferometer includes two nonlinear optical crystals placed on opposite sides of the plasma. This instrument has been used to measure electron line densities in a pulsed radio-frequency generated argon plasma. A simple phase-extraction technique based on combining measurements from two successive pulses of the plasma has been used. The noise-equivalent line density was measured to be 1.7 × 10{sup 17} m{sup −2} in a detection bandwidth of 950 kHz. One of the orientation-patterned crystals produced 13 mW of peak power at the second-harmonic wavelength from a carbon dioxide laser with 13 W of peak power. Two crystals arranged sequentially produced 58 mW of peak power at the second-harmonic wavelength from a carbon dioxide laser with 37 W of peak power.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full-Scale Field Test of Wake Steering

Wind farm control, in which turbine controllers are coordinated to improve farmwide performance, is an active field of research. One form of wind farm control is wake steering, in which a turbine is yawed to the inflow to redirect its wake away from downstream turbines. Wake steering has been studied in depth in simulations as well as in wind tunnels and scaled test facilities. This work performs a field test of wake steering on a full-scale turbine. In the campaign, the yaw controller of the turbine has been set to track different yaw misalignment set points while a nacelle-mounted lidar scans the wake at several ranges downwind. The lidar measurements are combined with turbine data, as well as measurements of the inflow made by a highly instrumented meteorological mast. In conclusion, these measurements are then compared to the predictions of a wind farm control-oriented model of wakes.

17 WIND ENERGY↗

Recent developments of MCViNE and its applications at SNS

Abstract MCViNE is an open source, object-oriented Monte Carlo neutron ray-tracing simulation software package. Its design allows for flexible, hierarchical representations of sophisticated instrument components such as detector systems, and samples with a variety of shapes and scattering kernels. Recently this flexible design has enabled several applications of MCViNE simulations at the Spallation Neutron Source (SNS) at Oak Ridge National Lab, including assisting design of neutron instruments at the second target station and design of novel sample environments, as well as studying effects of instrument resolution and multiple scattering. Here we provide an overview of the recent developments and new features of MCViNE since its initial introduction (Jiao et al 2016 Nucl. Instrum. Methods Phys. Res., Sect. A 810 , 86–99), and some example applications.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exploring team avionics systems by simulation

Configurations of software and hardware in a no-critical-element team architecture are under study for future general aviation aircraft avionics. The team integrated avionics system, based on microprocessors, can monitor and partially interpret all flight instrument data, engine parameters, and navigation information faster than a human pilot. Simulation programs based on an event-oriented simulation language are being used to design team architectures.

Brent, G. A.↗

Small ultrahigh vacuum compatible hyperthermal oxygen atom generator

The development of a compact, ultrahigh vacuum (UHV) compatible instrument for generating a flux of pure hyperthermal oxygen atoms for NASA applications has been achieved. The instrument combines the mechanisms of O2 dissociation and transport through a hot Ag membrane to provide a continuous source of O atoms to a vacuum interface where they are subsequently emitted into the vacuum space by electron-stimulated desorption (ESD). A flux of neutral O atoms 4.5 X 10(exp 13) cm(exp-2) s(exp-l)(P-3) with a mean ion kinetic energy of approximately 5eV and a full width at half maximum of 4eV was detected at a quadrupole mass spectrometer located 10 cm away. The geometry of the instrument is such that it is mounted on a 7 cm flange and can be tailored in length and orientation to fit most UHV systems. The data presented here are for ESD-controlled conditions where increases in the flux are strictly linear with electron bombardment current. Calculation shows that transport-controlled conditions can be achieved at temperatures as low as 350 C with membrane thicknesses on the order of 10 micron.

Outlaw, R. A.↗

A Distributed Data Architecture for 2001 Mars Odyssey Data Distribution

Newer instruments and communications techniques have given scientists unprecedented amounts of data, more than can be feasibly distributed through traditional methods such as mailed CD-ROM's. Leveraging the web makes sense since it enables scientists to request specific data and retrieve products as soon as they're available. Yet defining the middleware system to support such an application has remained just out of reach, until Odyssey. For the first time ever, data from all Odyssey mission instruments were made available through a single system immediately upon delivery to the Planetary Data System (PDS). The Object Oriented Data Technology (OODT) software made such an application possible.

distributed↗

A General Closed-Form Solution for the Lunar Reconnaissance Orbiter (LRO) Antenna Pointing System

The National Aeronautics and Space Administration s (NASA) Lunar Reconnaissance Orbiter (LRO) launched on June 18, 2009 from the Cape Canaveral Air Force Station aboard an Atlas V launch vehicle into a direct insertion trajectory to the Moon LRO, designed, built, and operated by the NASA Goddard Space Flight Center in Greenbelt, MD, is gathering crucial data on the lunar environment that will help astronauts prepare for long-duration lunar expeditions. During the mission s nominal life of one year its six instruments and one technology demonstrator will find safe landing site, locate potential resources, characterize the radiation environment and test new technology. To date, LRO has been operating well within the bounds of its requirements and has been collecting excellent science data images taken from the LRO Camera Narrow Angle Camera (LROC NAC) of the Apollo landing sites have appeared on cable news networks. A significant amount of information on LRO s science instruments is provided at the LRO mission webpage. LRO s Attitude Control System (ACS), in addition to controlling the orientation of the spacecraft is also responsible for pointing the High Gain Antenna (HGA). A dual-axis (or double-gimbaled) antenna, deployed on a meter-long boom, is required to point at a selected Earth ground station. Due to signal loss over the distance from the Moon to Earth, pointing precision for the antenna system is very tight. Since the HGA has to be deployed in spaceflight, its exact geometry relative to the spacecraft body is uncertain. In addition, thermal distortions and mechanical errors/tolerances must be characterized and removed to realize the greatest gain from the antenna system. These reasons necessitate the need for an in-flight calibration. Once in orbit around the moon, a series of attitude maneuvers was conducted to provide data needed to determine optimal parameters to load onboard, which would account for the environmental and mechanical errors at any antenna orientation. The nominal geometry for the HGA involves an outer gimbal axis that is exactly perpendicular to the inner gimbal axis, and a target direction that is exactly perpendicular to the outer gimbal axis. For this nominal geometry, closed-form solutions of the desired gimbal angles are simple to get for a desired target direction specified in the spacecraft body fame. If the gimbal axes and the antenna boresight are slightly misaligned, the nominal closed-form solution is not sufficiently accurate for computing the gimbal angles needed to point at a target. In this situation, either a general closed-form solution has to be developed for a mechanism with general geometries, or a correction scheme has to be applied to the nominal closed-form solutions. The latter has been adopted for Solar Dynamics Observatory (SDO) as can be seen in Reference 1, and the former has been used for LRO. The advantage of the general closed-form solution is the use of a small number of parameters for the correction of nominal solutions, especially in the regions near singularities. Singularities here refer to cases when the nominal closed-form solutions have two or more solutions. Algorithm complexity, however, is the disadvantage of the general closed-form solution.

Shah, Neerav↗

Early stage of nanocrystal growth

Berkeley Lab researchers at the Molecular Foundry have elucidated important mechanisms behind oriented attachment, the phenomenon that drives biomineralization and the growth of nanocrystals. This electron microscopy movie shows the early stage of nanocrystal growth. Nanoparticles make transient contact at many points and orientations until their lattices are perfectly matched. The particles then make a sudden jump-to-contact to form attached aggregates. (Movie courtesy of Jim DeYoreo)

47 OTHER INSTRUMENTATION↗

Avalanche photodiode based detector for beam emission spectroscopy

An avalanche photodiode based (APD) detector for the visible wavelength range was developed for low light level, high frequency beam emission spectroscopy (BES) experiments in fusion plasmas. This solid state detector has higher quantum efficiency than photomultiplier tubes, and unlike normal photodiodes, it has internal gain. This paper describes the developed detector as well as the noise model of the electronic circuit. By understanding the noise sources and the amplification process, the optimal amplifier and APD reverse voltage setting can be determined, where the signal-to-noise ratio is the highest for a given photon flux. The calculations are compared to the absolute calibration results of the implemented circuit. It was found that for a certain photon flux range, relevant for BES measurements ({approx_equal}10{sup 8}-10{sup 10} photons/s), the new detector is superior to both photomultipliers and photodiodes, although it does not require cryogenic cooling of any component. The position of this photon flux window sensitively depends on the parameters of the actual experimental implementation (desired bandwidth, detector size, etc.) Several detector units based on these developments have been built and installed in various tokamaks. Some illustrative results are presented from the 8-channel trial BES system installed at Mega-Ampere Spherical Tokamak (MAST) and the 16-channel BES system installed at the Torus Experiment for Technology Oriented Research (TEXTOR).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Turn indicator

This report presents a study of an instrument that can warn the pilot of the turning of his airplane. This instrument must satisfy three conditions: 1) It must give useful indication immediately from take-off; 2) The indications must be instantaneous and require no exertion by the pilot; 3) The indicator must be sensitive only to changes of orientation in the horizontal plane. Different solutions are presented such as a gyroscope driven by the suction of a Venturi tube.

INSTRUMENTS - TURN INDICATORS↗

Instrumentation optimization in Fourier spectroscopy. I - Far infrared beam splitters

Computations of the reflectivity, transmissivity, and efficiency properties for TE, TM, and T45 deg waves of far-infrared beam splitters and of the polarizations induced at both reflection and transmission are described. Effects of variations in the state of polarization, orientation, pointing accuracy, and wavelength of the incident light, as well as variations in refractive index and thickness of the beam splitters, are discussed. These results apply directly to Fourier interferometer-spectrometers. They can be used for optimizing the performance of these instruments. They indicate, in particular, that some advantages may be gained by the use of incident polarized light (angle of polarization smaller than about 45 deg or negative elliptical polarization) or light of large incidence angle (larger than approximately 60 deg) or both.

Deuze, J. L.↗

Resonant soft X-ray scattering in polymer science

Resonant soft X-ray scattering (RSoXS) is an emerging, powerful technique to probe the nano-to-mesoscale structure of polymers and other molecules. It joins together small-angle X-ray scattering (a statistical nanoprobe) with X-ray spectroscopy that brings with it unique chemical and bond-orientation sensitivity. Through over a decade of discovery and development, RSoXS is moving from a niche technique applied to organic electronic thin films to a mature tool applicable to a plethora of polymeric and molecular systems, encompassing new modalities, analyses, and simulation methods. This development promises to deliver increasingly quantitative answers to challenging questions in polymer science as well as expand its usefulness to complementary fields. Here, this review presents a full synopsis of the technique, including background on the theoretical underpinnings, measurement best practices, and examples of recent RSoXS applications and discoveries provided here to accelerate the transition to a broader range of soft matter and polymeric fields.

36 MATERIALS SCIENCE↗