Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Early results in the search for extreme coronal line emitters with the Dark Energy Spectroscopic Instrument

Here, we present the results of our search through the early data release (EDR) of the Dark Energy Spectroscopic Instrument (DESI) for extreme coronal line emitters (ECLEs) – a rare classification of galaxies displaying strong, high-ionization iron coronal emission lines within their spectra. With the requirement of a strong X-ray continuum to generate the coronal emission, ECLEs have been linked to both active galactic nuclei (AGNs) and tidal disruption events (TDEs). We focus our search on identifying TDE-linked ECLEs. We identify three such objects within the EDR sample, highlighting DESI’s effectiveness for discovering new nuclear transients, and determine a galaxy-normalized TDE-linked ECLE rate of RG=5 −3+5×10−6 galaxy−1 yr−1 at a median redshift of z=0.2 – broadly consistent with previous work. Additionally, we identify more than 200 AGNs displaying coronal emission lines, which serve as the primary astrophysical contaminants in searches for TDE-related events. We also include an outline of the custom python code developed for this search.

Clark, Peter [Southampton U.; Portsmouth U., ICG] ↗

High-resolution electron time-of-flight spectrometers for angle-resolved measurements at the SQS Instrument at the European XFEL

A set of electron time-of-flight spectrometers for high-resolution angle-resolved spectroscopy was developed for the Small Quantum Systems (SQS) instrument at the SASE3 soft X-ray branch of the European XFEL. The resolving power of this spectrometer design is demonstrated to exceed 10 000 (E/ΔE), using the well known Ne 1s –1 3p resonant Auger spectrum measured at a photon energy of 867.11 eV at a third-generation synchrotron radiation source. At the European XFEL, a width of ~0.5 eV full width at half-maximum for a kinetic energy of 800 eV was demonstrated. It is expected that this linewidth can be reached over a broad range of kinetic energies. An array of these spectrometers, with different angular orientations, is tailored for the Atomic-like Quantum Systems endstation for high-resolution angle-resolved spectroscopy of gaseous samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct LiF imaging diagnostics on refractive X-ray focusing at the EuXFEL High Energy Density instrument

The application of fluorescent crystal media in wide-range X-ray detectors provides an opportunity to directly image the spatial distribution of ultra intense X-ray beams including investigation of the focal spot of free-electron lasers. Here the capabilities of the micro- and nano-focusing X-ray refractive optics available at the High Energy Density instrument of the European XFEL are reported, as measured in situ by means of a LiF fluorescent detector placed into and around the beam caustic. The intensity distribution of the beam focused down to several hundred nanometers was imaged at 9 keV photon energy. A deviation from the parabolic surface in a stack of nanofocusing Be compound refractive lenses (CRLs) was found to affect the resulting intensity distribution within the beam. Comparison of experimental patterns in the far field with patterns calculated for different CRL lens imperfections allowed the overall inhomogeneity in the CRL stack to be estimated. The precise determination of the focal spot size and shape on a sub-micrometer level is essential for a number of high energy density studies requiring either a pin-size backlighting spot or extreme intensities for X-ray heating.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Python Instrument Control and Data Acquisition Suite for Reproducible Research

Tools that standardize and automate experimental data collection are needed for greater confidence in research results. The National Synchrotron Light Source-II (NSLS-II) has generated an open-source Python data acquisition, management, and analysis software suite that automates X-ray experiments and collects an experimental record that facilitates complete reproducibility. Here, we show that the NSLS-II tools are not only useful for X-ray science at large-scale facilities by presenting an add-on package that adapts these tools for use in a small laboratory with common physics and electrical engineering instruments. The composite software suite eases and automates the execution of experiments, records extensive metadata, stores data in portable containers, and speeds up the analysis through tools for comprehensive searches. In total, this software suite increases the reproducibility of laboratory experiments. We demonstrate the software via the evaluation of two lock-in amplifiers-the miniature ADA2200 and the ubiquitous Stanford Research Systems (SRS) SR810. The frequency resolution, signal-to-noise ratio, and dynamic reserve of the lock-in amplifiers are measured and presented. The usage of the software suite is described throughout these measurements so that the reader can implement the tools in their lab.

97 MATHEMATICS AND COMPUTING↗

Calibration, modeling, parameterization, and verification of the instrument transfer function of an interferometric microscope

Interferometric microscopes are used to measure surface roughness, from which the computed power spectral density function can be used to extract bandwidth-limited values of the various surface properties, such as root-mean-square (rms) height and slope errors. Measurements with a microscope equipped with different objectives that have an overlapping spatial frequency range usually give different rms results over the common frequency bandwidth. This is a result of different instrument transfer functions (ITFs) that attenuate spatial frequencies by different amounts over the overlapping range. We report on the use of binary pseudo-random array (BPRA) standards to characterize the ITF of an interferometric microscope with the various objectives. We use a simple model of a 1D binary Results show that the spectrum for an undersampled array is a cosine function, rather than a straight line, constant white noise spectrum. We have an analytical model of the ITF that includes the effects of an obscured aperture and defocus, in addition to the usual parameters of numerical aperture, wavelength, and sampling period. In addition, the model includes the effect of aliasing of spatial frequency components beyond the Nyquist back into the sub-Nyquist region. We compare the model PSD predictions to the measurements performed with different objectives. Departures of the measured PSDs from the model predictions indicate that there are higher-order ITF corrections yet to be identified and included in the model.

Takacs, PZ↗

Instrumentation and Techniques in High Energy Physics

This book provides an introduction of some of the technology and techniques of modern particle physics. Each chapter is a deep dive into the relevant subject, which includes silicon pixel detectors, plastic scintillator in a high radiation environment, Cerenkov detectors, particle jet identification, noble gas neutrino detectors, and machine learning. The target audience is graduate students and more senior researchers who wish to learn a new technology or technique. The text pedagogical in nature and each chapter is a standalone treatment of a specific topic. The coverage focuses on state-of-the-art techniques, rather than describing the technology's history. Written by acknowledged experts in the subject matter, Instrumentation and Techniques in High Energy Physics, is an important addition to the library of any particle physicist.

Lincoln, Don↗

Quantum Instrumentation Control Kit Defect Arbitrary Waveform Generator (QICKDAWG) v.0

SAND2024-08598O The Quantum Instrumentation Control Kit Defect Arbitrary Waveform Generator (QICKDAWG) characterizes nitrogen-vacancy centers in diamond and other defects. It does this by using a radio frequency system-on-a-chip (RFSoC) field programmable gate array (FPGA). QICKDAWG synthesizes microwave pulses from the RFSoC to change the spin state of the defects. The software also allows for laser control using the RFSoC, which optically pumps defects. Ultimately, QICKDAWG supports the implementation of RFSoC FPGAs in defect characterization. This replaces the slow, expensive, traditional hardware, thus lowering the cost and time for defect characterization. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

SciDAC↗

Scientific Directions for Cloud Chamber Research: Instrumentation, Modeling, New Chambers, and Emerging Chamber Concepts

The Workshop on Scientific Directions for Cloud Chamber Research was held 13-14 July 2024 at the National Institute for Meteorological Sciences, Jeju, South Korea. Here, over 75 scientists from 13 countries gathered to learn about and discuss the latest scientific research results from large laboratory cloud chamber facilities, as well as new developments in cloud chamber instrumentation and modeling efforts, and emerging cloud chamber designs that will open new scientific research directions.

54 ENVIRONMENTAL SCIENCES↗

An Instrumented Capsule Design to Measure Thermal Conductivity in Miniature UO2 Specimens

Numerous separate effects irradiations of miniature nuclear fuel specimens have been conducted in the High Flux Isotope Reactor (HFIR) under the experimental platform designated as MiniFuel. MiniFuel is a static irradiation capability in which microstructural evolution and fuel performance phenomena are observed during postirradiation examination thereby offering a snapshot of the terminal fuel characteristics. This approach inherently requires fielding an irradiation where the experimental conditions are determined using predictive models and the pertinent outcomes are measured at the end of the test. Static irradiations can provide useful insights to the relationships between fuel performance and the pivotal irradiation conditions, namely temperature and burnup, but the ability to monitor fuel performance in situ would further support fuel development and qualification. To this end, an instrumented experiment design is being developed at Oak Ridge National Laboratory to capture thermal conductivity degradation and fission gas release during HFIR irradiation. These phenomena will be monitored using unique capsule designs that each target a different phenomenon. This paper details the thermal conductivity capsule (TCC) design and its expected performance envelope as determined using computer models. Each TCC will contain a miniature UO2 disc specimen (~0.5 mm thick × 5 mm diameter) sandwiched between metallic slugs with embedded thermocouples. The coupling of in situ temperature measurements, known thermal conductivity of the metallic components, and heat generation rates computed using high-fidelity neutronics models make the thermal conductivity measurement possible. This paper describes the reactor physics and heat transfer models used to predict the capsule’s performance and the methodology for calculating the fuel specimen’s thermal conductivity from the thermocouple measurements.

Gorton, Jacob [ORNL] (ORCID:0000000269806083)↗

Topography restoration in white-light interferometry using an instrument transfer function evaluated with binary pseudo-random arrays

Accurate knowledge of the instrument transfer function (ITF) is vital for topography measurements using white-light interferometry (WLI). To this end, we derive a complete set of analytical expressions for the power spectral density (PSD) of a discretely sampled binary pseudo-random array (BPRA) as a theoretical benchmark. We then determine the ITF by comparing this theoretical PSD with the measured PSD of the BPRA. For the Zygo ZeGage Pro HR with a objective, the determined ITF closely matches the nominal modulation transfer function (MTF). Accordingly, we integrate the nominal MTF into Fourier-domain restoration filters and apply them to practical WLI topography data, yielding restored topographies that show improved agreement with atomic force microscopy measurements. Overall, our integrated BPRA-based ITF measurement and filtering methodology offers a robust yet practical means of characterizing WLI performance and enhancing the accuracy of surface measurements.

Hirose, Shigenobu [Japan Agency for Marine Earth S↗

Beam Instrumentation at the Fermilab IOTA Ring

The Integrable Optics Test Accelerator (IOTA) is a storage ring located at the end of the Fermilab Accelerator Science and Technology (FAST) facility. The complex is intended to support accelerator R&D for the next generation of particle accelerators. The IOTA ring is currently operating with 100 MeV electrons injected from the FAST Linac and will also receive 2.5 MeV protons from the IOTA Proton Injector currently being installed. The current instrumentation and results from the first electron commissioning run will be presented along with future plans.

43 PARTICLE ACCELERATORS↗

AI-driven neutrino diagnostics and radiation-hard beam instrumentation for next-generation neutrino experiments

The Long Baseline Neutrino Facility (LBNF) at Fermilab will deliver a high-intensity, multi-megawatt neutrino beam to the Deep Underground Neutrino Experiment (DUNE), enabling precision tests of the three-neutrino paradigm, CP violation searches, neutrino mass ordering determination, and supernova neutrino studies. To accelerate DUNE’s physics reach and ensure robust beam operations, we propose an integrated AI-driven framework with real-time diagnostics and radiation-hardened instrumentation. At its core is a Real-Time Beam Integrity Monitor using a physics-informed Digital Twin. By reconstructing pion phase space from muon profiles and exploiting magnetic horn optic linearity, it enables spill-by-spill beam correction and flux stabilization. By using this approach, flux-related systematics could be reduced from 5% to 1%, potentially accelerating the discovery of CP violations by four to six years. Complementing this, a US–Japan R&D effort will deploy a LAPPD-based muon monitor in the NuMI beamline. ToF measurements can be acquired with picosecond precision using this radiation-hard system, enhancing sensitivity to horn chromatic effects. Simulations confirm strong response to these effects. ML models predict beam quality and horn current to sub-percent accuracy from muon data, enhancing anomaly detection and stability. This scalable, AI-enabled strategy improves beam fidelity, reduces systematics, and sets a new standard for high-power accelerator operations.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

Hardware-Control: Instrument control and automation package

Conducting experimental research often relies on the control of laboratory instruments to, for example, control power supplies, move stages, and measure data. Tasks, such as data logging or parameter scans, often need to be automated. Being able to easily create a user interface to the hardware and to be able to reuse code is highly desirable.

97 MATHEMATICS AND COMPUTING↗

Radar Wind Profiler (RWP) and Radio Acoustic Sounding System (RASS) Instrument Handbook

The radar wind profiler (RWP) is an active remote-sensing instrument that can routinely, and virtually unattended, observe wind and turbulence in the troposphere through scattering from clear-air irregularities of the atmospheric refractive index (Gage and Balsley 1978). The principle of Doppler radars in general is based on sending electromagnetic pulses in the vertical and several tilted directions (vertical and oblique beams) and measuring the signal that is scattered back by atmospheric turbulence at all heights and received at the antenna. The RWPs provides measurements of backscattered signal strength and wind profiles nominally between 0.1 km and 6 km. The RWP operation assumes that the wind field is homogeneous over the spatial separation of the antenna beams, which is a safe assumption under stable atmospheric conditions. However, the wind may be different between the beams due to significant changes in the wind field, resulting in erroneous wind calculations. Therefore, the radial measurements are averaged over a sufficient time period to validate the assumption of homogeneity.

54 ENVIRONMENTAL SCIENCES↗

Doppler Lidar (DL) Instrument Handbook

The Doppler lidar (DL) is an active remote sensing instrument that provides range- and time-resolved measurements of radial velocity and attenuated backscatter. The principle of operation is similar to radar in that pulses of energy are transmitted into the atmosphere; the energy scattered back to the transceiver is collected and measured as a time-resolved signal. From the time delay between each outgoing transmitted pulse and the backscattered signal, the distance to the scatterer is inferred. The radial or line-of-sight velocity of the scatterers is determined from the Doppler frequency shift of the backscattered radiation. The DL uses a heterodyne detection technique in which the return signal is mixed with a reference laser beam (i.e., local oscillator) of known frequency. An onboard signal processing computer then determines the Doppler frequency shift from the spectra of the heterodyne signal. The energy content of the Doppler spectra can also be used to determine attenuated backscatter.

99 GENERAL AND MISCELLANEOUS↗

Atmospheric Observation System for Greenhouse Gases (GHG) Instrument Handbook

The Greenhouse Gas (GhG) Measurement system is a combination of two systems in series: (1) the Tower Gas Processing (TGP) System, an instrument rack which pulls, pressurizes, and dries air streams from an atmospheric sampling tower through a series of control and monitoring components, and (2) the Picarro model G2301 cavity ringdown spectrometer (CRDS), which measures CO2, CH4, and H2O vapor; the primary measurements of the GhG system.

54 ENVIRONMENTAL SCIENCES↗