Search NASA⌕ Search

SEARCH · Search NASA

Results for “INTERFEROMETER SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Proceedings from the 2nd International Symposium on Formation Flying Missions and Technologies

Topics discussed include: The Stellar Imager (SI) "Vision Mission"; First Formation Flying Demonstration Mission Including on Flight Nulling; Formation Flying X-ray Telescope in L2 Orbit; SPECS: The Kilometer-baseline Far-IR Interferometer in NASA's Space Science Roadmap Presentation; A Tight Formation for Along-track SAR Interferometry; Realization of the Solar Power Satellite using the Formation Flying Solar Reflector; SIMBOL-X : Formation Flying for High-Energy Astrophysics; High Precision Optical Metrology for DARWIN; Close Formation Flight of Micro-Satellites for SAR Interferometry; Station-Keeping Requirements for Astronomical Imaging with Constellations of Free-Flying Collectors; Closed-Loop Control of Formation Flying Satellites; Formation Control for the MAXIM Mission; Precision Formation Keeping at L2 Using the Autonomous Formation Flying Sensor; Robust Control of Multiple Spacecraft Formation Flying; Virtual Rigid Body (VRB) Satellite Formation Control: Stable Mode-Switching and Cross-Coupling; Electromagnetic Formation Flight (EMFF) System Design, Mission Capabilities, and Testbed Development; Navigation Algorithms for Formation Flying Missions; Use of Formation Flying Small Satellites Incorporating OISL's in a Tandem Cluster Mission; Semimajor Axis Estimation Strategies; Relative Attitude Determination of Earth Orbiting Formations Using GPS Receivers; Analysis of Formation Flying in Eccentric Orbits Using Linearized Equations of Relative Motion; Conservative Analytical Collision Probabilities for Orbital Formation Flying; Equations of Motion and Stability of Two Spacecraft in Formation at the Earth/Moon Triangular Libration Points; Formations Near the Libration Points: Design Strategies Using Natural and Non-Natural Ares; An Overview of the Formation and Attitude Control System for the Terrestrial Planet Finder Formation Flying Interferometer; GVE-Based Dynamics and Control for Formation Flying Spacecraft; GNC System Design for a New Concept of X-Ray Distributed Telescope; GNC System for the Deployment and Fine Control of the DARWIN Free-Flying Interferometer; Formation Algorithm and Simulation Testbed; and PLATFORM: A Formation Flying, RvD and Robotic Validation Test-bench.

Source record↗

Development of non-intrusive instrumentation for NASA-Ames Ballistic Range and Shock Tunnel

The use of nonintrusive instrumentation in high-enthalpy facilities offers the opportunity to collect data that has previously been difficult or impossible to obtain. Three such instruments, now under development, are described: an OH absorption system which can measure OH species concentration and temperature, a holographic interferometer for flow visualization and density measurement at low density, and a telemetry system which allows the measurement of surface quantities on model in free-flight at hypervelocity. The challenges and opportunities encountered when employing these advanced diagnostics to high-enthalpy facilities are discussed.

Strawa, A. W.↗

Swept Frequency Laser Metrology System

A swept frequency laser ranging system having sub-micron accuracy that employs multiple common-path heterodyne interferometers, one coupled to a calibrated delay-line for use as an absolute reference for the ranging system. An exemplary embodiment uses two laser heterodyne interferometers to create two laser beams at two different frequencies to measure distance and motions of target(s). Heterodyne fringes generated from reflections off a reference fiducial X(sub R) and measurement (or target) fiducial X(sub M) are reflected back and are then detected by photodiodes. The measured phase changes Delta phi(sub R) and Delta phi (sub m) resulting from the laser frequency swept gives target position. The reference delay-line is the only absolute reference needed in the metrology system and this provides an ultra-stable reference and simple/economical system.

Zhao, Feng↗

Internal measurements of electromagnetic geodesic acoustic mode (GAM) in EAST plasmas

Velocity, density, and magnetic fluctuations of the geodesic acoustic mode (GAM) have been measured using the Doppler backscattering system, Faraday-effect polarimeter-interferometer, and external pick-up coils in the Experimental Advanced Superconducting Tokamak. Simultaneous measurements of density and velocity fluctuations at the midplane and top of plasmas demonstrate that m = 1 density fluctuations are quantitatively balanced by the compression of perpendicular flow fluctuations. Furthermore, internal magnetic fluctuations associated with GAM have now been directly measured by laser-based Faraday-effect polarimetry for the first time. Line-averaged magnetic fluctuations (up to 16 Gauss, B̃¯R,GAMBT∼0.066%) are significantly larger than those extrapolated from edge coils (a few Gauss) and that magnetic fluctuations increase with β. The observed discrepancy between finite β theory and experimental data indicates the need for further theoretical investigations.

Physics↗

Aircraft altitude determination using multipath information in an angle-measuring navigation satellite system

In an angle-measuring navigation satellite system using a pair of crossed interferometers located on a satellite in synchronous orbit, three parameters are needed to determine a user's position unambiguously. These are the phase differences between received signals which were transmitted by the two antennas on each of the two interferometers, and the user's altitude. The two phase difference measurements yield a line of possible user locations, and the addition of the altitude measurement reduces this line to a single point. A method is proposed which makes use of the navigation signals received after reflection off the earth's surface. The iterative procedure employs the arrival time difference between direct and reflected signals. Based on previous calculations of errors in measuring the electrical parameters it is concluded that, for North Atlantic coverage and specular reflection, altitude measurements can be made with a 1-sigma error of 65 meters.

Kurjan, D.↗

Laser measuring system for incremental assemblies

Wire-wrapped frame assemblies used in spark chambers and the like can be measured using a system which utilizes a laser, an interferometer, and a retroreflector to precisely measure distance. A light source and a photodetector are located adjacent the incremental assembly and mounted on a movable carriage. The interferometer is also mounted on the movable carriage, while the laser and retroreflector are positioned at either end of the carriage track. The carriage is moved along one edge of the incremental assembly between the retroreflector and the laser, and as the carriage is moved, the light from the light source to the photodetector is interrupted. This produces a trigger command to a control unit which in turn causes a distance measurement to be made. A printout is provided for each sampling trigger command to list such items as ideal position, actual position and amount of error.

Etzel, J. G.↗

Facility for interferometric testing of 1.25-m mirrors at liquid helium temperatures

A concept is presented for a national cryogenic optics test facility capable of optical characterization of 1.25 m diameter optics having focal lengths up to 6.2 m at temperatures from 300 K to near 4 K. The facility will be comprised of a large Dewar with a phase shift interferometer, a two-stage vacuum system employing a turbomolecular pump, and an integral vibration isolation system. The entire facility will be housed in a concrete site with a massive floor to assist in reducing vibration during optical tests. By providing interchangeable sections, the overall height of the Dewar can be adjusted to provide for testing of shorter focal length optics. The background for the facility is discussed along with the facility location, and the requirements and the performance considerations which drive the Dewar design with respect to the vibration isolation system, vacuum system, and optical interferometry.

Salerno, Louis J.↗

Wide Angle, Single Screen, Gridded Square-Loop Frequency Selective Surface for Diplexing Two Closely Separated Frequency Bands

The design and performance of a wide angle, single screen, frequency selective surface (FSS) with gridded square-loop path elements are described for diplexing closely separated signal bands, for example, X- and Ku-band signals in an Orbiting Very Long Baseline Interferometer (OVLBI) earth station reflector antenna system, as well as other applications such as military and commercial communications via satellites. Excellent agreement is obtained between the predicted and measured results of this FSS design using the gridded square-loop patch elements sandwiched between 0.0889 cm thick tetrafluoroethylene fluorocarbon polymer (PTFE) slabs. Resonant frequency drift is reduced by 1 GHz with an incidence angle from 0 deg normal to 40 deg from normal.

Wu, Te-Kao↗

Scientific Applications of Optical Instruments to Materials Research

Microgravity is a unique environment for materials and biotechnology processing. Microgravity minimizes or eliminates some of the effects that occur in one g. This can lead to the production of new materials or crystal structures. It is important to understand the processes that create these new materials. Thus, experiments are designed so that optical data collection can take place during the formation of the material. This presentation will discuss scientific application of optical instruments at MSFC. These instruments include a near-field scanning optical microscope, a miniaturized holographic system, and a phase-shifting interferometer.

Witherow, William K.↗

Lessons Learned During Cryogenic Optical Testing of the Advanced Mirror System Demonstrators (AMSDs)

Optical testing in a cryogenic environment presents a host of challenges above and beyond those encountered during room temperature testing. The Advanced Mirror System Demonstrators (AMSDs) are 1.4 m diameter, ultra light-weight (<20 kg/mA2), off-axis parabolic segments. They are required to have 250 nm PV & 50 nm RMS surface figure error or less at 35 K. An optical testing system, consisting of an Instantaneous Phase Interferometer (PI), a diffractive null corrector (DNC), and an Absolute Distance Meter (ADM), was used to measure the surface figure & radius-of-curvature of these mirrors at the operational temperature within the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center (MSFC). The Ah4SD program was designed to improve the technology related to the design, fabrication, & testing of such mirrors in support of NASA s James Webb Space Telescope (JWST). This paper will describe the lessons learned during preparation & cryogenic testing of the AMSDs.

Hadaway, James↗

On the Antenna Pattern of Orbitting Interferometer

We consider the response of an interferometer moving with respect to a fixed reference frame, and derive a simple expression for the beam-pattern factors and the polarization-averaged antenna power pattern...Then, we consider a class of motions where the detector's plane is constrained to move on the surface of a cone of constant aperture; at the same time, the two arms are rotating around a vertical axis...In addition, we consider the case of an Earth-based interferometer...Finally, we discuss LISA's response to circularly polarized sinusoidal waves, coming from a few known binary systems in our Galaxy.

interferometer interferometry antenna motions LISA↗

Solar Confocal Interferometers for Sub-Picometer-Resolution Spectral Filters

The confocal Fabry-Perot interferometer allows sub-picometer spectral resolution of Fraunhofer line profiles. Such high spectral resolution is needed to keep pace with the higher spatial resolution of the new set of large-aperture solar telescopes. The line-of-sight spatial resolution derived for line profile inversions would then track the improvements of the transverse spatial scale provided by the larger apertures. The confocal interferometer's unique properties allow a simultaneous increase in both etendue and spectral power. Methods: We have constructed and tested two confocal interferometers. Conclusions: In this paper we compare the confocal interferometer with other spectral imaging filters, provide initial design parameters, show construction details for two designs, and report on the laboratory test results for these interferometers, and propose a multiple etalon system for future testing of these units and to obtain sub-picometer spectral resolution information on the photosphere in both the visible and near-infrared.

Gary, G. Allen↗

Black Holes, Gravitational Waves, and LISA

Binary black hole mergers are central to many key science objectives of the Laser Interferometer Space Antenna (LISA). For many systems the strongest part of the signal is only understood by numerical simulations. Gravitational wave emissions are understood by simulations of vacuum General Relativity (GR). I discuss numerical simulation results from the perspective of LISA's needs, with indications of work that remains to be done. Some exciting scientific opportunities associated with LISA observations would be greatly enhanced if prompt electromagnetic signature could be associated. I discuss simulations to explore this possibility. Numerical simulations are important now for clarifying LISA's science potential and planning the mission. We also consider how numerical simulations might be applied at the time of LISA's operation.

Baker, John↗

Laser Mode Behavior of the Cassini CIRS Fourier Transform Spectrometer at Saturn

The CIRS Fourier transform spectrometer aboard the NASA/ESA/ASI Cassini orbiter has been acquiring spectra of the Saturnian system since 2004. The CIRS reference interferometer employs a laser diode to trigger the interferogram sampling. Although the control of laser diode drive current and operating temperature are stringent enough to restrict laser wavelength variation to a small fraction of CIRS finest resolution element, the CIRS instrument does need to be restarted every year or two, at which time it may start in a new laser mode. By monitoring the Mylar absorption features in uncalibrated spectra due to the beam splitter Mylar substrate, it can be shown that these jumps are to adjacent modes and that most of the eight-year operation so far is restricted to three adjacent modes. For a given mode, the wavelength stability appears consistent with the stability of the laser diode drive curren.t and operating temperature.

Brasunas, John C.↗

Khayyam; Progress and Prospects of Coupling a Spatial Heterodyne Spectrometer (SHS) to a Cassegrain Telescope for Optical Interferometry

In the temporal study of faint, extended sources at high resolving power, Spatial Heterodyne Spectrometer (SHS) can offer significant advantages about conventional dispersive grating spectrometers. We describe here a four-year continuous progress in Mt. Hamilton, Lick Observatory, toward development of a prototype reflective Spacial Heterodyne Spectrometer, Khayyam, instrument-telescope configuration to combine all of the capabilities necessary to obtain high resolving power visible band spectra of diffuse targets from small aperture on-axis telescopes where significant observing time can be obtained. We will discuss the design considerations going into this new system, installation, testing of the interferometer-telescope combination, the technical challenges and procedures moving forward.

extended targets↗