Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION PROBES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Isostructural bridging diferrous chalcogenide cores [Fe II (μ-E)Fe II ] (E = O, S, Se, Te) with decreasing antiferromagnetic coupling down the chalcogenide series

Iron compounds containing a bridging oxo or sulfido moiety are ubiquitous in biological systems, but substitution with the heavier chalcogenides selenium and tellurium, however, is much rarer, with only a few examples reported to date. Here we show that treatment of the ferrous starting material [( tBu pyrpyrr 2 )Fe(OEt 2 )] (1-OEt 2 ) ( tBu pyrpyrr 2 = 3,5- t Bu 2 -bis(pyrrolyl)pyridine) with phosphine chalcogenide reagents E = PR 3 results in the neutral phosphine chalcogenide adduct series [( tBu pyrpyrr 2 )Fe(EPR 3 )] (E = O, S, Se; R = Ph; E = Te; R = t Bu) (1-E) without any electron transfer, whereas treatment of the anionic starting material [K] 2 [( tBu pyrpyrr 2 )Fe 2 (μ-N 2 )] (2-N 2 ) with the appropriate chalcogenide transfer source yields cleanly the isostructural ferrous bridging mono-chalcogenide ate complexes [K] 2 [( tBu pyrpyrr 2 )Fe 2 (μ-E)] (2-E) (E = O, S, Se, and Te) having significant deviation in the Fe–E–Fe bridge from linear in the case of E = O to more acute for the heaviest chalcogenide. All bridging chalcogenide complexes were analyzed using a variety of spectroscopic techniques, including 1 H NMR, UV-Vis electronic absorbtion, and 57 Fe Mössbauer. The spin-state and degree of communication between the two ferrous ions were probed via SQUID magnetometry, where it was found that all iron centers were high-spin (S = 2) Fe II , with magnetic exchange coupling between the Fe II ions. Magnetic studies established that antiferromagnetic coupling between the ferrous ions decreases as the identity of the chalcogen is tuned from O to the heaviest congener Te.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RF Technologies for Future Colliders

Particle colliders remain indispensable scientific instruments to discover and study new elementary particles and fundamental forces of nature. Whether the collider is a factory (used to improve precision of measuring properties of already discovered particles or to enable studies of rare decay channels), an energy frontier machine (aimed at discovering new particles and forces), a heavy ion collider (allowing studies of what the universe looked like in the early moments after its creation), or an electron-hadron collider (where electrons are used for probing heavy ions or protons to study the fundamental force binding all visible matter), the radio frequency technologies play a key role in enabling the machine to reach its goals. This article considers challenges presented to the radio frequency technologies by the next generation of particle colliders and reviews R&D approaches and directions to address these challenges.

43 PARTICLE ACCELERATORS↗

An APFIM/AEM Study of Phase Decompositions in Fe-Ni Alloys at Low Temperatures

A combined atom probe field ion microscopy and analytical electron microscopy characterization has been performed on laboratory aged martensitic and austenitic specimens of FeNi and FeNiP alloys. These techniques revealed that the martensitic 24.1 and 28.6 at.% Ni alloys decomposed during aging for 1 year at 300 C to form face centered cubic precipitates of approx. 56 at.% Ni in a body centered cubic matrix containing approx. 20 at.% Ni. Some thin platelets were observed in the field ion micrographs of the austenitic Fe-42.9 at. % Ni alloy and the Fe-43.2 at.% Ni-0.44 at.% P alloy after aging at 400 and 350 C. Atom probe analysis revealed phosphorus clustering in the ternary alloy aged at 300 C.

Zhang, J.↗

Flowing Plasma Interaction with an Electric Sail Tether Element

Electric sails are a relatively new concept for providing high speed propellant-less propulsion. Employing multiple tethers biased to high positive voltage levels (kV), electric sails are designed to gain momentum from the solar wind by repelling solar wind protons. To maximize the area of the sail that interacts with the solar wind, electric sails rely on the formation of a large plasma sheath around each small diameter tether. Motivated by interest in advancing the development of electric sails, a set of laboratory tests has been conducted to study the interaction of a drifting plasma with a sheath formed around a small diameter tether element biased at positive voltages. The laboratory test setup was created with Debye length scaling in mind to offer a path to extrapolate (via modeling) to full scale electric sail missions. Using an instrument known as a Differential Ion Flux Probe (DIFP) the interaction between a positively biased tether element and a drifting plasma has been measured for several scenarios. Clear evidence of the tether element sheath deflecting ions has been obtained. Maps of the flow angle downstream from the tether element have been made and they show the influence of the plasma sheath. Finally, electron current collection measurements have been made for a wide range of plasma conditions and tether element bias voltages. The electron collection data will have an impact on electric sail power requirements, as high voltage power supplies and electron guns will have to be sized to accommodate the electron currents collected by each tether.

Schneider, Todd↗

Refractory rf ovens and sputter probes for electron cyclotron resonance ion source

Beams from electron cyclotron resonance ion source (ECRIS) with radio frequency ovens for refractory material (using a Mo coil) were recently demonstrated; results for Ti and V are here discussed, with temperature T{sub s}{>=}2300 K stably maintained and extracted current of about 1000 nA for V{sup 8+} and V{sup 9+}. The status of sputter probes is also reported, and the reason why trapping efficiency may be lower than in the oven case are investigated. The simple tubular probe concept show typical currents of Sn{sup 18+} about 250 nA, for the most abundant isotopes, but an operating pressure of about 300 {mu}Pa may be required. Some preliminary experiments were performed with Penning probes, showing that transmission of Sn or Pr from Penning cathode to ECRIS plasma is limited. Placement of tin onto anticathode and use of collimator between Penning and ECRIS are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ionotail of Venus - Its configuration and evidence for ion escape

The configuration and morphology of the plasma clouds in the ionotail of Venus (revealed by the Pioneer Venus Orbiter) are studied, and the rate of planetary ion escape, which may be associated with the dissipation and removal of the ionospheric plasma, is estimated. The data supplied by the Orbiter's instruments, the Orbiter electron temperature probe, the ion mass spectrometer, the neutral mass spectrometer, the magnetometer, and the plasma analyzer, are analyzed, and the results of the observations are discussed.

Brace, L. H.↗

Instrument for differential on flux vector measurements on Spacelab 2

The DIF (differential ion flux) probe used on the Spacelab-2 mission as part of the PDP (plasma diagnostic package) as well as the DIF design, operational characteristics and data reduction procedures required to obtain plasma properties are described. The basic principles, the sensor head design, and the electronics design are discussed. Plasma properties such as ion drift energy and temperature, ion flow direction, and ion flux density are explained, and in addition, calibration procedures and calibration data on detection of multiple ion streams and detection of ion streams superimposed on an isotropic plasma are analyzed. Finally, the mounting and role of the DIF probe on the PDP are briefly reviewed. Schematics of the instrument and of its control logic are included.

Stone, N. H.↗

Turbulent transport of fast ions in the Large Plasma Device

Strong drift wave turbulence is observed in the Large Plasma Device [H. Gekelman et al., Rev. Sci. Instrum. 62, 2875 (1991)] on density gradients produced by a plate limiter. Energetic lithium ions orbit through the turbulent region. Scans with a collimated ion analyzer and with Langmuir probes give detailed profiles of the fast ion spatial distribution and the fluctuating fields. The fast ion transport decreases rapidly with increasing fast ion gyroradius. Unlike the diffusive transport caused by Coulomb collisions, in this case the turbulent transport is nondiffusive. Analysis and simulation suggest that such nondiffusive transport is due to the interaction of the fast ions with stationary two-dimensional electrostatic turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Further observations of Space Shuttle plasma-electrodynamic effects from OSS-1/STS-3

Recent analyses of ion measurements obtained from the Differential Ion Flux Probe (DIFP) on the deployed Plasma Diagnostics Package (PDP) during the OSS-1/STS-3 mission have provided an additional insight into the plasma-electrodynamics of the Space Shuttle Orbiter: (1) Measured ion flow directions and energies suggest that the disturbance created in the ionospheric plasma by the Shuttle Orbiter may be confined to an interaction region that extends on the order of 10 m in the forward direction and has a boundary thickness of about 2 m. (2) A correlation between the DIFP and pressure gauge measurements indicates a direct, local proportionality between the neutral gas and ion densities. (3) Preliminary results from a theoretical model of the possible interaction between measured secondary, high inclination ion streams and the ambient plasma indicate the generation of broad-band electrostatic noise such as that observed by wave instruments on the PDP.

Stone, N. H.↗

Concentration and velocity profiles in a polymeric lithium-ion battery electrolyte

Predictive knowledge of ion transport in electrolytes which bridges microscopic and macroscopic length scales is imperative to design new ion conductors and to simulate device performance. Here, we employed a novel approach combining operando X-ray photon correlation spectroscopy, X-ray absorption microscopy, continuum modelling, and molecular dynamics simulations to probe the ion transport in a baseline polymeric lithium-ion battery electrolyte. In a Li/PEO–LiTFSI/Li symmetric cell under polarization, we determined and rationalized microscopic properties including local electrolyte velocities and ion correlations and connected this insight to measured and simulated macroscopic ion concentration gradients. By relating our results across length scales, we suggest a fairly concentration-independent transference number of about 0.2. Our study shows the broad applicability of operando X-ray photon correlation spectroscopy to the understanding of dynamic phenomena.

25 ENERGY STORAGE↗

Plant Available Nutrients, Utqiagvik (Barrow), Alaska, Ver. 1

This dataset reports measurements of plant available nutrients made using Plant Root Simulator (PRS) probes (Western Ag Innovations Inc.) during 2012 and 2013 at the Next-Generation Ecosystem Experiments (NGEE) Arctic field site near Utqiagvik (Barrow), Alaska. In 2012, Ca, Mg, K, P, Fe, Mn, Cu, Zn, B, S, Pb, Al, Cd, NO3-N and NH4-N availability were measured during spring, summer and winter from probes installed in the centers, edges and troughs of four polygons in each of four areas of contrasting moisture regime and polygon type (Areas A, B, C, and D of Intensive Site 1). In 2013, probes were installed in centers, edges and troughs of four polygons in each of two areas (A and B, with low-centered and high-centered polygons respectively) at two-week intervals and at 3 soil depths to capture fine-scale seasonal dynamics of NO3-N and NH4-N. PRS probes are ion exchange resin membranes held in plastic supports that are inserted into soil to measure ion supply in situ. The anion and cation exchange with the membrane is intended to mimic plant uptake and thus provide a relevant measure of soil nutrient bioavailability. Measurements are made per area of probe membrane and cannot be converted to concentrations or related to soil volume. This dataset includes five csv files and three pdf files.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Imaging Jupiter's aurorae from H3+ emissions in the 3-4 micrometers band

Since H3+ was first spectroscopically detected on Jupiter, there has been considerable interest in using this simple molecular ion to probe conditions existing in the planet's auroral regions. Here we present a series of images of Jupiter recorded at wavelengths sensitive to emission by H3+, which reveal the spatial distribution of excited H3+ molecular ions in the jovian ionosphere, as seen from Earth. We believe that they provide high-spatial-resolution images of polar aurorae on Jupiter. They suggest that the intensity of the auroral emission can vary on a timescale of an hour, a shorter period than had previously been noted. We also find that the spatial distribution of H3+ emissions correlates only partially with the loci of auroral activity inferred from ultraviolet and longer-wavelength infrared observations. The H3+ emission may therefore be controlled by auroral processes that are different from those responsible for the ultraviolet and infrared emissions.

Non-NASA Center↗

Ion-neutral Coupling During Deep Solar Minimum

The equatorial ionosphere under conditions of deep solar minimum exhibits structuring due to tidal forces. Data from instruments carried by the Communication Navigation Outage Forecasting System (CNOFS) which was launched in April 2008 have been analyzed for the first 2 years following launch. The Planar Langmuir Probe (PLP), Ion Velocity Meter (IVM) and Vector Electric Field Investigation (VEFI) all detect periodic structures during the 20082010 period which appear to be tides. However when the tidal features detected by these instruments are compared, there are distinctive and significant differences between the observations. Tides in neutral densities measured by the Gravity Recovery and Climate Experiment (GRACE) satellite were also observed during June 2008. In addition, Broad Plasma Decreases (BPDs) appear as a deep absolute minimum in the plasma and neutral density tidal pattern. These are co-located with regions of large downward-directed ion meridional velocities and minima in the zonal drifts, all on the nightside. The region in which BPDs occur coincides with a peak in occurrence rate of dawn depletions in plasma density observed on the Defense Meterological Satellite Program (DMSP) spacecraft, as well as a minimum in radiance detected by UV imagers on the Thermosphere Ionosphere Mesosphere Energetics and Dynamics (TIMED) and IMAGE satellites

IVM↗

Overestimation of Mach number due to probe shadow

Comparisons of the plasma ion flow speed measurements from Mach probes and laser induced fluorescence were performed in the Controlled Shear Decorrelation Experiment. We show the presence of the probe causes a low density geometric shadow downstream of the probe that affects the current density collected by the probe in collisional plasmas if the ion-neutral mean free path is shorter than the probe shadow length, L g = w 2 V drift /D ⊥ , resulting in erroneous Mach numbers. We also present a simple correction term that provides the corrected Mach number from probe data when the sound speed, ion-neutral mean free path, and perpendicular diffusion coefficient of the plasma are known. The probe shadow effect must be taken into account whenever the ion-neutral mean free path is on the order of the probe shadow length in linear devices and the open-field line region of fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗