Search NASA⌕ Search

SEARCH · Search NASA

Results for “Infrared sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

An infrared survey of Galactic supernova remnants

A survey of Galactic supernova remnants (SNRs) in the infrared has been completed. Flux densities or upper limits on the flux densities have been measured for 157 objects in each of the four broad bands surveyed by the Infrared Astronomical Satellite (IRAS). Nearly one-third of the known SNRs exhibit some evidence of infrared emission. Confusion with other Galactic sources is a serious problem. Contour maps and halftone images are presented for 51 SNRs which are probable infrared sources. Initial analysis indicates that both the infrared spectra or colors and the ratio of infrared to radio brightnesses can discriminate between the youngest SNRs and older SNRs. In general, however, SNRs cannot be distinguished from other Galactic sources solely on the basis of their infrared colors. No apparent relation is found between the infrared surface brightnesses and the diameters of SNRs.

Arendt, Richard G.↗

ARACHNID: A prototype object-oriented database tool for distributed systems

This paper discusses the results of a Phase 2 SBIR project sponsored by NASA and performed by MIMD Systems, Inc. A major objective of this project was to develop specific concepts for improved performance in accessing large databases. An object-oriented and distributed approach was used for the general design, while a geographical decomposition was used as a specific solution. The resulting software framework is called ARACHNID. The Faint Source Catalog developed by NASA was the initial database testbed. This is a database of many giga-bytes, where an order of magnitude improvement in query speed is being sought. This database contains faint infrared point sources obtained from telescope measurements of the sky. A geographical decomposition of this database is an attractive approach to dividing it into pieces. Each piece can then be searched on individual processors with only a weak data linkage between the processors being required. As a further demonstration of the concepts implemented in ARACHNID, a tourist information system is discussed. This version of ARACHNID is the commercial result of the project. It is a distributed, networked, database application where speed, maintenance, and reliability are important considerations. This paper focuses on the design concepts and technologies that form the basis for ARACHNID.

Younger, Herbert↗

Measuring Irradiance Over Large Areas

Relatively simple experimental technique yields data processed, via straightforward mathematical model, into map of thermal irradiance over large area. Imaging infrared radiometer makes temperature map of sheet. Irradiance distribution at sheet location then deduced from temperature map. Used to obtain rapid measurements of incident-flux distribution over broad spectral range at specific locations relative to such heat sources as infrared heat lamps or lasers.

Glazer, Stuart D.↗

High resolution spectroscopy in the microwave and far infrared

High resolution rotational spectroscopy has long been central to remote sensing techniques in atmospheric sciences and astronomy. As such, laboratory measurements must supply the required data to make direct interpretation of data for instruments which sense atmospheres using rotational spectra. Spectral measurements in the microwave and far infrared regions are also very powerful tools when combined with infrared measurements for characterizing the rotational structure of vibrational spectra. In the past decade new techniques were developed which have pushed high resolution spectroscopy into the wavelength region between 25 micrometers and 2 mm. Techniques to be described include: (1) harmonic generation of microwave sources, (2) infrared laser difference frequency generation, (3) laser sideband generation, and (4) ultrahigh resolution interferometers.

Pickett, Herbert M.↗

Best Practices for Body Temperature Measurement with Infrared Thermography: External Factors Affecting Accuracy

Infrared thermographs (IRTs) are commonly used during disease pandemics to screen individuals with elevated body temperature (EBT). To address the limited research on external factors affecting IRT accuracy, we conducted benchtop measurements and computer simulations with two IRTs, with or without an external temperature reference source (ETRS) for temperature compensation. The combination of an IRT and an ETRS forms a screening thermograph (ST). We investigated the effects of viewing angle (θ, 0–75°), ETRS set temperature (T ETRS , 30–40 °C), ambient temperature (T atm , 18–32 °C), relative humidity (RH, 15–80%), and working distance (d, 0.4–2.8 m). We discovered that STs exhibited higher accuracy compared to IRTs alone. Across the tested ranges of T atm and RH, both IRTs exhibited absolute measurement errors of less than 0.97 °C, while both STs maintained absolute measurement errors of less than 0.12 °C. The optimal T ETRS for EBT detection was 36–37 °C. When θ was below 30°, the two STs underestimated calibration source (CS) temperature (T CS ) of less than 0.05 °C. The computer simulations showed absolute temperature differences of up to 0.28 °C and 0.04 °C between estimated and theoretical temperatures for IRTs and STs, respectively, considering d of 0.2–3.0 m, T atm of 15–35 °C, and RH of 5–95%. The results highlight the importance of precise calibration and environmental control for reliable temperature readings and suggest proper ranges for these factors, aiming to enhance current standard documents and best practice guidelines. These insights enhance our understanding of IRT performance and their sensitivity to various factors, thereby facilitating the development of best practices for accurate EBT measurement.

47 OTHER INSTRUMENTATION↗

Tunable Mid-Infrared Interband Emission from Tensile-Strained InGaAs Quantum Dots

We demonstrate the ability to tailor self-assembled growth of In 0.5 Ga 0.5 As quantum dots (QDs) on GaSb(111)A surfaces by molecular beam epitaxy. Spontaneous formation via the Volmer–Weber growth mode produces QDs with excellent structural and optical quality. By harnessing tensile strain to reduce their band gap energy, these QDs are characterized by light emission that extends into the midwave infrared wavelength range of 3.2–3.9 μm (0.318–0.388 eV). As we increase QD size, we can tune the band alignment from type-III to type-II, where light emission occurs due to interband recombination between quantum confined electrons in the InGaAs QDs and holes in the GaSb barriers. Of particular interest is an unusual blue-shift in emission wavelength with increasing QD size, which we attribute to the incorporation of Sb into the InGaAs QDs from the GaSb barriers. By expanding this approach to produce tensile-strained QDs from other narrow band gap semiconductors, we anticipate the development of a range of highly tunable mid-infrared light sources.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of Carbon Dioxide Sensors for the Constellation Space Suit Life Support System for Surface Exploration

This paper presents the findings of the trade study to evaluate carbon dioxide (CO2) sensing technologies for the Constellation (Cx) space suit life support system for surface exploration. The trade study found that nondispersive infrared absorption (NDIR) is the most appropriate high Technology Readiness Level (TRL) technology for the CO2 sensor for the Cx space suit. The maturity of the technology is high, as it is the basis for the CO2 sensor in the Extravehicular Mobility Unit (EMU). The study further determined that while there is a range of commercial sensors available, the Cx CO2 sensor should be a new design. Specifically, there are light sources (e.g., infrared light emitting diodes) and detectors (e.g., cooled detectors) that are not in typical commercial sensors due to cost. These advanced technology components offer significant advantages in performance (weight, volume, power, accuracy) to be implemented in the new sensor. The exact sensor design (light source, transmitting optics, path length, receiving optics and detector) will be specific for the Cx space suit and will be determined by the performance requirements of the Cx space suit. The paper further identifies specifications for some of the critical performance parameters as well as discussing the engineering aspects of implementing the sensor into the Portable Life Support System (PLSS). The paper then presents testing results from three CO2 sensors with respect to issues important to Extravehicular Activity (EVA) applications; stability, humidity dependence and low pressure compatibility. The three sensors include two NDIR sensors, one commercial and one custom-developed by NASA (for a different purpose), and one commercial electrochemical sensor. The results show that both NDIR sensors have excellent stability, no dependence on ambient humidity (when the ambient temperature is above the dew point) and operate in low pressure conditions and after being exposed to a full vacuum. The commercial electrochemical sensor was not suitable for the Cx space suit for surface exploration. Finally, the paper identifies a number of techniques currently under development that offer significant advantages for EVA applications. These include miniaturized, room temperature, solid electrolyte systems and advanced optical detectors.

Dietrich, Daniel L.↗

Far-infrared observations of a luminous dust-shrouded source in the nucleus of NGC 4945

High-resolution far-infrared observations of the galaxy NGC 4945 have been obtained from the Kuiper Airborne Observatory. Using new observational techniques and nonlinear deconvolution routines, it is found that virtually all of the far-infrared luminosity originates from a nuclear source no larger than 12 arcsec x 9 arcsec (225 pc x 170 pc) in extent. This size constraint, coupled with the far-infrared dust temperature, indicates that the source is deeply embedded in dust: the lower limit for the 100 micron optical depth is 0.35, which is by far the largest yet measured in an external galaxy. Published optical spectra of NGC 4945 reveal a heavily obscured nonthermal source which exhibits broad line profiles typical of a Seyfert 2 active nucleus; it is concluded that the far-infrared emission is probably due to thermal radiation from dust grains surrounding the nonthermal nuclear source. A compact cluster of massive young stars may also contribute to the infrared luminosity, but the evidence for such star-forming activity is weak.

Brock, David↗

A search for precursors of ultracompact H II regions in a sample of luminous IRAS sources. III. Circumstellar dust properties

The James Clerk Maxwell Telescope has been used to obtain submillimeter and millimeter continuum photometry of a sample of 30 IRAS sources previously studied in molecular lines and centimeter radio continuum. All the sources have IRAS colours typical of very young stellar objects (YSOs) and are associated with dense gas.

(astronomical) pre-main-sequence stars radiosource↗

Interpretation of Beta Lyrae. III - A study of the disk around the secondary component

Light curves of Beta Lyrae available in the far-ultraviolet, visual, and infrared regions of the spectrum at numerous phases in eclipse are analyzed in order to investigate the physical and radiative nature of the disk surrounding the secondary component. The results of this analysis together with those of other investigators lead to the proposal that the outer regions of the disk are dominated by free electrons. This electron-scattering envelope is most likely the source of infrared radiation as well as the cause of the observed polarization. However, the radiation in the region from the optical to the far-ultraviolet comes mainly from submerged layers where local thermodynamic equilibrium prevails. These layers represent the photosphere of either the disk or the secondary component itself.

Brown, D. A.↗

Object-Based Comparison of Data-Driven and Physics-Driven Satellite Estimates of Extreme Rainfall

The Global Precipitation Measurement (GPM) constellation of spaceborne sensors provides a variety of direct and indirect measurements of precipitation processes. Such observations can be employed to derive spatially and temporally consistent gridded precipitation estimates either via data-driven retrieval algorithms or by assimilation into physically based numerical weather models. We compare the data-driven Integrated Multisatellite Retrievals for GPM (IMERG) and the assimilation-enabled NASA-Unified Weather Research and Forecasting (NU-WRF) model against Stage IV reference precipitation for four major extreme rainfall events in the southeastern United States using an object-based analysis framework that decomposes gridded precipitation fields into storm objects. As an alternative to conventional ‘‘grid-by-grid analysis,’’ the object-based approach provides a promising way to diagnose spatial properties of storms, trace them through space and time, and connect their accuracy to storm types and input data sources. The evolution of two tropical cyclones are generally captured by IMERG and NU-WRF, while the less organized spatial patterns of two mesoscale convective systems pose challenges for both. NU-WRF rain rates are generally more accurate, while IMERG better captures storm location and shape. Both show higher skill in detecting large, intense storms compared to smaller, weaker storms. IMERG’s accuracy depends on the input microwave and infrared data sources; NU-WRF does not appear to exhibit this dependence. Findings highlight that an object-oriented view can provide deeper insights into satellite precipitation performance and that the satellite precipitation community should further explore the potential for ‘‘hybrid’’ data-driven and physics-driven estimates in order to make optimal usage of satellite observations.

extreme events↗

Infrared Astronomical Satellite (IRAS) analysis, introduction

Stray light transmittance analysis on a design of the Infrared Astronomical Satellite (IRAS) is presented. The system was evaluated for scattered radiation propagation with the use of the APART (Arizon's Paraxial Analysis of Radiation Transfer), and the propagation of diffracted energy with both PADE (Paraxial Analysis of Diffracted Energy) and the GUERAP II programs. The scattered radiation analysis was performed by using both a 5% diffuse black on the baffle and vane surfaces and by using a mathematical model of the Martin Black scattering characteristics. The sources of infrared radiation and of radiation in the visible wavelengths are identified. Diffraction effects are dominant only at the large off-axis angles, except for a few specific cases and smaller angles. At the longer wavelengths the diffraction contributions go up significantly. It is the comparative increase which determines which propagation process predominates. Combined transmittance values are presented.

Source record↗

Recent progress in development of mid-IR interband cascade lasers

Type-II interband cascade lasers are promising in becoming efficient and compact mid-infrared light sources for many applications. Significant progress toward such a goal has recently been made in terms of lowering their threshold current densities and raising operation temperature. Also, continuous wave operation of single-mode distributed feedback interband cascade lasers has been demonstrated. We review the recent progress of the Sb-based mid-IR interband cascade lasers and present some latest results.

lasers↗

ROSAT X-Ray Observation of the Second Error Box for SGR 1900+14

The positions of the two error boxes for the soft gamma repeater (SGR) 1900+14 were determined by the "network synthesis" method, which employs observations by the Ulysses gamma-ray burst and CGRO BATSE instruments. The location of the first error box has been observed at optical, infrared, and X-ray wavelengths, resulting in the discovery of a ROSAT X-ray point source and a curious double infrared source. We have recently used the ROSAT HRI to observe the second error box to complete the counterpart search. A total of six X-ray sources were identified within the field of view. None of them falls within the network synthesis error box, and a 3 sigma upper limit to any X-ray counterpart was estimated to be 6.35 x 10(exp -14) ergs/sq cm/s. The closest source is approximately 3 min. away, and has an estimated unabsorbed flux of 1.5 x 10(exp -12) ergs/sq cm/s. Unlike the first error box, there is no supernova remnant near the second error box. The closest one, G43.9+1.6, lies approximately 2.dg6 away. For these reasons, we believe that the first error box is more likely to be the correct one.

Li, P.↗

Recent progress in the development of antimonide-based mid-ir interband cascade lasers

Antimonide-based type-II interband cascade lasers are promising in becoming efficient and compact mid-infrared light sources for many applications such as gas sensing and environmental monitoring. Significant progress toward such a goal has recently been made in terms of achieving low threshold current densities, high temperature operation, and continuous wave operation of single-mode distributed feedback lasers. We review the recent progress of Sb-based mid-IR IC lasers and address the requirements for further improvements in their performance.

semiconductor superlattices↗

Far-infrared observations of H 2 regions and associated galactic and extragalactic sources

Using imaging techniques maps were made at 50 and 100 micrometers with one foot resolution of a region around the galactic center about one-half degree in extent. Higher resolution maps were made of the central portion of the galaxy at 30, 50, and 100 micrometers. Resolution maps of a reflection nebula were also made. Infrared sources associated with molecular clouds were investigated.

Source record↗

Multicolor Inks of Black Phosphorus for Midwave‐Infrared Optoelectronics

Abstract Black phosphorus (bP) based ink with a bulk bandgap of 0.33 eV ( λ = 3.7 µm) has recently been shown to be promising for large‐area, high performance mid‐wave infrared (MWIR) optoelectronics. However, the development of multicolor bP inks expanding across the MWIR wavelength range has been challenging. Here a multicolor ink process based on bP with spectral emission tuned from 0.28 eV ( λ = 4.4 µm) to 0.8 eV ( λ = 1.5 µm) is demonstrated. Specifically, through the reduction of bP particle size distribution (i.e., lateral dimension and thickness), the optical bandgap systematically blueshifts, reaching up to 0.8 eV. Conversely, alloying bP with arsenic (bP 1− x As x ) induces a redshift in the bandgap to 0.28 eV. The ink processed films are passivated with an infrared‐transparent epoxy for stable infrared emission in ambient air. Utilizing these multicolor bP‐based inks as an infrared light source, a gas sensing system is demonstrated that selectively detects gases, such as CO 2 and CH 4 whose absorption band varies around 4.3 and 3.3 µm, respectively. The presented ink formulation sets the stage for the advancement of multiplex MWIR optoelectronics, including spectrometers and spectral imaging using a low‐cost material processing platform.

Kim, Jae Ik↗