Search NASA⌕ Search

SEARCH · Search NASA

Results for “Initialization method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Partition-of-unity finite-element method for large scale quantum molecular dynamics on massively parallel computational platforms

Over the course of the past two decades, quantum mechanical calculations have emerged as a key component of modern materials research. However, the solution of the required quantum mechanical equations is a formidable task and this has severely limited the range of materials systems which can be investigated by such accurate, quantum mechanical means. The current state of the art for large-scale quantum simulations is the planewave (PW) method, as implemented in now ubiquitous VASP, ABINIT, and QBox codes, among many others. However, since the PW method uses a global Fourier basis, with strictly uniform resolution at all points in space, and in which every basis function overlaps every other at every point, it suffers from substantial inefficiencies in calculations involving atoms with localized states, such as first-row and transition-metal atoms, and requires substantial nonlocal communications in parallel implementations, placing critical limits on scalability. In recent years, real-space methods such as finite-differences (FD) and finite-elements (FE) have been developed to address these deficiencies by reformulating the required quantum mechanical equations in a strictly local representation. However, while addressing both resolution and parallel-communications problems, such local real-space approaches have been plagued by one key disadvantage relative to planewaves: excessive degrees of freedom (grid points, basis functions) needed to achieve the required accuracies. And so, despite critical limitations, the PW method remains the standard today. In this work, we show for the first time that this key remaining disadvantage of real-space methods can in fact be overcome: by building known atomic physics into the solution process using modern partition-of-unity (PU) techniques in finite element analysis. Indeed, our results show order-of-magnitude reductions in basis size relative to state-of-the-art planewave based methods. The method developed here is completely general, applicable to any crystal symmetry and to both metals and insulators alike. We have developed and implemented a full self-consistent Kohn-Sham method, including both total energies and forces for molecular dynamics, and developed a full MPI parallel implementation for large-scale calculations. We have applied the method to the gamut of physical systems, from simple insulating systems with light atoms to complex d- and f-electron systems, requiring large numbers of atomic-orbital enrichments. In every case, the new PU FE method attained the required accuracies with substantially fewer degrees of freedom, typically by an order of magnitude or more, than the current state-of-the-art PW method. Finally, our initial MPI implementation has shown excellent parallel scaling of the most time-critical parts of the code up to 1728 processors, with clear indications of what will be required to achieve comparable scaling for the rest. Having shown that the key remaining disadvantage of real-space methods can in fact be overcome, the work has attracted significant attention: with sixteen invited talks, both domestic and international, so far; two papers published and another in preparation; and three new university and/or national laboratory collaborations, securing external funding to pursue a number of related research directions. Having demonstrated the proof of principle, work now centers on the necessary extensions and optimizations required to bring the prototype method and code delivered here to production applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mode Initialization for On-line Estimation of Power System Electromechanical Modes

Measurement-based mode estimation methods are utilized to estimate electromechanical modes of a power system using phasor measurement units (PMU) data. These methods need to extract a certain amount of information before they can give useable mode estimation. Traditionally, the information is gathered solely from measurement data. Priori mode information from other resources (e.g. model eigenvalue analysis, engineering knowledge) are not fully utilized. For real time application, this means that mode estimation takes time to converge. By adding a mode regularization term in the objective function, this paper proposes a mode initialization method to include priori mode information in a regularized robust recursive least squares (R3LS) algorithm for on-line mode estimation. The proposed method is tested using a simple model, a 17 machine model and is shown to be able to shorten the convergence period of the R3LS algorithm. The proposed method is also applied on the measurement data recorded right before a major power outage in the western North American Grid on August 10th 1996 to show its potential applica-tion in detecting an approaching small signal stability problem.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancements to the RAVEN code in FY16

The RAVEN code has been under development at the Idaho National Laboratory since 2012. Its main goal is to create a multi-purpose platform for the deploying of all the capabilities needed for Probabilistic Risk Assessment, uncertainty quantification, data mining analysis and optimization studies. RAVEN has currently reached a good level of maturity in terms of deployed state-of-art and advanced capabilities. The main subject of this report is to show the activities that have been recently accomplished: • Implementation of ensemble modeling for time-series, and • initial implementation of model validation for surrogate models, and • advanced visualization capability for topology based data analysis The development of ensemble modeling for time-series has been performed in order to begin tackling the needs of those RISMC applications that need to communicate 1-Dimensional information (e.g. power histories, etc.) among different models. In this document the implementation details and an application example is reported. The second subject of this report is about the initial development of methods, within the RAVEN framework, to assess the validity of the predictive capabilities of surrogate models. Indeed, after the construction of a surrogate tight to a certain physical model, it is crucial to assess the goodness of its representation, in order to be confident with its prediction. In this initial activity, a cross-validation technique has been employed. This report will highlight the implementation details and proof its correct implementation by an application example. The final subject of this report is about the implementation of advanced visualization capability in RAVEN, for interactive data analysis. Indeed, RAVEN offers several post-processing capabilities that can structurally decompose data extracted from experimental results offering both data clustering/partitioning and dimensionality reduction techniques. A disadvantage of the workflow available in RAVEN is that it treats these as black box operations and the user is expected to know specific information about their data including the number of partitions to expect in some cases or the “correct” parameter settings for a particular algorithm. In order to overcome this limitation, it has been added an interactive user interface that can be run in RAVEN to explore different parameter settings on the fly specifically for the topological post-processor and allows the user to explore the data interactively. The design of this user interface is generalizable to other algorithms and can be used as a model to generate more dynamic and user-friendly visualization capabilities within RAVEN.

97 MATHEMATICS AND COMPUTING↗

Reducing noise in cosmological N-body simulations with neutrinos

In this study, we present a new method for generating initial conditions for numerical cosmological simulations in which massive neutrinos are treated as an extra set of N-body (collisionless) particles. It allows us to accurately follow the density field for both Cold Dark Matter (CDM) and neutrinos at both high and low redshifts. At high redshifts, the new method is able to reduce the shot noise in the neutrino power spectrum by a factor of more than 107 compared to previous methods, where the power spectrum was dominated by shot noise at all scales. We find that our new approach also helps to reduce the noise on the total matter power spectrum on large scales, whereas on small scales the results agree with previous simulations. Our new method also allows for a systematic study of clustering of the low velocity tail of the distribution function of neutrinos. Lastly, this method also allows for the study of the evolution of the overall velocity distribution as a function of the environment determined by the CDM field.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantifying Initial State Fluctuations in Heavy Ion Collisions

Quantum fluctuations induce interesting structures in the initial state profiles for hydrodynamic calculations of the hot and dense quark-gluon plasma phase of heavy ion collisions. Especially, after the discovery of non-zero odd higher flow coefficients, there has been a lot of theoretical effort to quantify the correlation lengths of energy density fluctuations. A new method to characterize initial state profiles based on a 2D Fourier analysis is presented and an outlook on how this analysis can lead to a better quantitative understanding of the properties of hot and dense nuclear matter is given.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Restoration of the covariant gauge α in the initial field of gravity in de Sitter spacetime

The gravitational field generated by a mass term and the initial surface through covariant retarded Green's function for linearized gravity in de Sitter spacetime was studied recently [4, 5] with the covariant gauges set to β = 2/3 and α = 5/3. In this paper we extend the work to restore the gauge parameter α in the field coming from the initial data using the method of shifting the parameter. The α terms in the initial field cancels exactly with the one coming from the source term. Consequently, the correct field configuration, with two equal mass points moving in its geodesic, one located at the North pole and another one located at the South pole, is reproduced in the whole manifold of de Sitter spacetime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Automatic registration between reference and on-board digital tomosynthesis images for positioning verification

The authors developed a hybrid multiresolution rigid-body registration technique to automatically register reference digital tomosynthesis (DTS) images with on-board DTS images to guide patient positioning in radiation therapy. This hybrid registration technique uses a faster but less accurate static method to achieve an initial registration, followed by a slower but more accurate adaptive method to fine tune the registration. A multiresolution scheme is employed in the registration to further improve the registration accuracy, robustness, and efficiency. Normalized mutual information is selected as the criterion for the similarity measure and the downhill simplex method is used as the search engine. This technique was tested using image data both from an anthropomorphic chest phantom and from eight head-and-neck cancer patients. The effects of the scan angle and the region-of-interest (ROI) size on the registration accuracy and robustness were investigated. The necessity of using the adaptive registration method in the hybrid technique was validated by comparing the results of the static method and the hybrid method. With a 44 deg. scan angle and a large ROI covering the entire DTS volume, the average of the registration capture ranges in single-axis simulations was between -31 and +34 deg. for rotations and between -89 and +78 mm for translations in the phantom study, and between -38 and +38 deg. for rotations and between -58 and +65 mm for translations in the patient study. Decreasing the DTS scan angle from 44 deg. to 22 deg. mainly degraded the registration accuracy and robustness for the out-of-plane rotations. Decreasing the ROI size from the entire DTS volume to the volume surrounding the spinal cord reduced the capture ranges to between -23 and +18 deg. for rotations and between -33 and +43 mm for translations in the phantom study, and between -18 and +25 deg. for rotations and between -35 and +39 mm for translations in the patient study. Results also showed that the hybrid registration technique had much larger capture ranges than the static method alone in registering the out-of-plane rotations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Sedov Blast Wave as a Radial Piston Verification Test

The Sedov blast wave is of great utility as a verification problem for hydrodynamic methods. The typical implementation uses an energized cell of finite dimensions to represent the energy point source. We avoid this approximation by directly finding the effects of the energy source as a boundary condition (BC). Furthermore, the proposed method transforms the Sedov problem into an outward moving radial piston problem with a time-varying velocity. A portion of the mesh adjacent to the origin is removed and the boundaries of this hole are forced with the velocities from the Sedov solution. This verification test is implemented on two types of meshes, and convergence is shown. Our results from the typical initial condition (IC) method and the new BC method are compared.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An adaptive regularization parameter choice strategy for multispectral bioluminescence tomography

Purpose: Bioluminescence tomography (BLT) provides an effective tool for monitoring physiological and pathological activities in vivo. However, the measured data in bioluminescence imaging are corrupted by noise. Therefore, regularization methods are commonly used to find a regularized solution. Nevertheless, for the quality of the reconstructed bioluminescent source obtained by regularization methods, the choice of the regularization parameters is crucial. To date, the selection of regularization parameters remains challenging. With regards to the above problems, the authors proposed a BLT reconstruction algorithm with an adaptive parameter choice rule. Methods: The proposed reconstruction algorithm uses a diffusion equation for modeling the bioluminescent photon transport. The diffusion equation is solved with a finite element method. Computed tomography (CT) images provide anatomical information regarding the geometry of the small animal and its internal organs. To reduce the ill-posedness of BLT, spectral information and the optimal permissible source region are employed. Then, the relationship between the unknown source distribution and multiview and multispectral boundary measurements is established based on the finite element method and the optimal permissible source region. Since the measured data are noisy, the BLT reconstruction is formulated as l{sub 2} data fidelity and a general regularization term. When choosing the regularization parameters for BLT, an efficient model function approach is proposed, which does not require knowledge of the noise level. This approach only requests the computation of the residual and regularized solution norm. With this knowledge, we construct the model function to approximate the objective function, and the regularization parameter is updated iteratively. Results: First, the micro-CT based mouse phantom was used for simulation verification. Simulation experiments were used to illustrate why multispectral data were used rather than monochromatic data. Furthermore, the study conducted using an adaptive regularization parameter demonstrated our ability to accurately localize the bioluminescent source. With the adaptively estimated regularization parameter, the reconstructed center position of the source was (20.37, 31.05, 12.95) mm, and the distance to the real source was 0.63 mm. The results of the dual-source experiments further showed that our algorithm could localize the bioluminescent sources accurately. The authors then presented experimental evidence that the proposed algorithm exhibited its calculated efficiency over the heuristic method. The effectiveness of the new algorithm was also confirmed by comparing it with the L-curve method. Furthermore, various initial speculations regarding the regularization parameter were used to illustrate the convergence of our algorithm. Finally, in vivo mouse experiment further illustrates the effectiveness of the proposed algorithm. Conclusions: Utilizing numerical, physical phantom and in vivo examples, we demonstrated that the bioluminescent sources could be reconstructed accurately with automatic regularization parameters. The proposed algorithm exhibited superior performance than both the heuristic regularization parameter choice method and L-curve method based on the computational speed and localization error.

61 RADIATION PROTECTION AND DOSIMETRY↗

Patient-bounded extrapolation using low-dose priors for volume-of-interest imaging in C-arm CT

Purpose: Three-dimensional (3D) volume-of-interest (VOI) imaging with C-arm systems provides anatomical information in a predefined 3D target region at a considerably low x-ray dose. However, VOI imaging involves laterally truncated projections from which conventional reconstruction algorithms generally yield images with severe truncation artifacts. Heuristic based extrapolation methods, e.g., water cylinder extrapolation, typically rely on techniques that complete the truncated data by means of a continuity assumption and thus appear to be ad-hoc. It is our goal to improve the image quality of VOI imaging by exploiting existing patient-specific prior information in the workflow. Methods: A necessary initial step prior to a 3D acquisition is to isocenter the patient with respect to the target to be scanned. To this end, low-dose fluoroscopic x-ray acquisitions are usually applied from anterior–posterior (AP) and medio-lateral (ML) views. Based on this, the patient is isocentered by repositioning the table. In this work, we present a patient-bounded extrapolation method that makes use of these noncollimated fluoroscopic images to improve image quality in 3D VOI reconstruction. The algorithm first extracts the 2D patient contours from the noncollimated AP and ML fluoroscopic images. These 2D contours are then combined to estimate a volumetric model of the patient. Forward-projecting the shape of the model at the eventually acquired C-arm rotation views gives the patient boundary information in the projection domain. In this manner, we are in the position to substantially improve image quality by enforcing the extrapolated line profiles to end at the known patient boundaries, derived from the 3D shape model estimate. Results: The proposed method was evaluated on eight clinical datasets with different degrees of truncation. The proposed algorithm achieved a relative root mean square error (rRMSE) of about 1.0% with respect to the reference reconstruction on nontruncated data, even in the presence of severe truncation, compared to a rRMSE of 8.0% when applying a state-of-the-art heuristic extrapolation technique. Conclusions: The method we proposed in this paper leads to a major improvement in image quality for 3D C-arm based VOI imaging. It involves no additional radiation when using fluoroscopic images that are acquired during the patient isocentering process. The model estimation can be readily integrated into the existing interventional workflow without additional hardware.

60 APPLIED LIFE SCIENCES↗

A Second Look at Neutron Resonance Transmission Analysis as a Spent Fuel NDA Technique

Many different nondestructive analysis techniques are currently being investigated as a part of the United States Department of Energy's Next Generation Safeguards Initiative (NGSI) seeking methods to quantify plutonium in spent fuel. Neutron Resonance Transmission Analysis (NRTA) is one of these techniques. Having first been explored in the mid-1970s for the analysis of individual spent-fuel pins a second look, using advanced simulation and modeling methods, is now underway to investigate the suitability of the NRTA technique for assaying complete spent nuclear fuel assemblies. The technique is similar to neutron time-of-flight methods used for cross-section determinations but operates over only the narrow 0.1-20 eV range where strong, distinguishable resonances exist for both the plutonium (239, 240, 241,242Pu) and uranium (235,236,238U) isotopes of interest in spent fuel. Additionally, in this energy range resonances exists for six important fission products (99Tc, 103Rh, 131Xe, 133Cs, 145Nd, and 152Sm) which provide additional information to support spent fuel plutonium assay determinations. Initial modeling shows excellent agreement with previously published experimental data for measurements of individual spent-fuel pins where plutonium assays were demonstrated to have a precision of 2-4%. Within the simulation and modeling analyses of this project scoping studies have explored fourteen different aspects of the technique including the neutron source, drift tube configurations, and gross neutron transmission as well as the impacts of fuel burn up, cooling time, and fission-product interferences. These results show that NRTA may be a very capable experimental technique for spent-fuel assay measurements. The results suggest sufficient transmission strength and signal differentiability is possible for assays through up to 8 pins. For an 8-pin assay (looking at an assembly diagonally), 64% of the pins in a typical 17 ? 17 array of a pressurized water reactor fuel assembly can be part of a complete transmission assay measurement with high precision. Analysis of rows with up to 12 pins may also be feasible but with diminished precision. Preliminary data analysis of an NRTA simulation has demonstrated the simplicity of the technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensor Anomaly Detection for Nuclear Reactor Systems Utilizing Linear Regression and K-Means Unsupervised Machine Learning

Nuclear reactors and related systems are becoming increasingly complex due to advancing technologies in next-generation power reactors. This increased complexity necessitates enhanced automation and data management capabilities. To successfully realize autonomous systems, methods must be developed to handle vast volumes of data and effectively distinguish anomalous data from noise and expected data. While impressive models utilizing digital twins and similar approaches are under development, here we propose a simplified model for analyzing fundamental methods and techniques. Initially, we created a general dataset by using initial data from PCTRAN in order to represent ideal steady-state conditions. We then inserted anomalies based on prevalent sensor anomaly types (e.g., point anomalies, linear drift, and downward deviations), along with unusual anomalies such as exponential drift and upward deviations. To detect anomalies, we developed a program that employs data partitioning and linear regression to preprocess and filter the anomalous data. A K-Means machine learning (ML) method was then applied to separate and count the data within the anomalous partition. The results from all datasets—apart from exponential growth—demonstrated positive outcomes, with each returning multiple instances of greaterthan-95% accuracy. We conducted further investigations using Idaho National Laboratory’s RAVEN software to perform a sensitivity analysis on the input variables (R 2 Tolerance, Slope Tolerance, and Window Size) and found that the output variables (Accuracy and Time) were most sensitive to the Window Size. Despite the promising results published, further development is required to effectively apply these methods to nuclear systems. Nevertheless, the strengths of this approach are evident and hold promise for future applications in the field.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Generic Modeling and Development Approach for WECC Composite Load Model

The composite load model (CLM) proposed by Western Electricity Coordinating Council (WECC) gains increasing traction in the industry, particularly in North America. At the same time, it is recognized that further improvements in the structure, initialization and aggregation methods are needed. However, lack of an open implementation of WECC CLM becomes a roadblock for many researchers to work on improving it. This paper presents the first open reference implementation of WECC CLM. Individual load components and the CLM are first developed and tested in Matlab, then translated to the high performance computing (HPC), parallel simulation platform GridPACK. Main contributions of the paper include: 1) presenting some important yet undocumented details of modeling and initializing the CLM, particularly for a parallel simulation platform like GridPACK; 2) implementation details of the load components such as the single-phase air conditioner motor; 3) implementing the CLM in a modular and extensible manner. The implementation has been tested at both the component as well as system levels and bench-marked against commercial simulation programs.

Huang, Qiuhua↗

Vulnerability of larval and juvenile white sturgeon to barotrauma: can they handle the pressure?

Techniques were developed to determine which life stages of fish are vulnerable to barotrauma from expansion of internal gases during decompression. Eggs, larvae and juvenile hatchery-reared white sturgeon (Acipenser transmontanus; up to 91 days post hatch; dph), were decompressed to assess vulnerability to barotrauma and identify initial swim bladder inflation. Barotrauma related injury and mortality were first observed 9 dph, on the same day as initial exogenous feeding. However, barotrauma related injury did not occur again until swim bladder inflation 75 dph (visible from necropsy and x-ray radiographs). Swim bladder inflation was not consistent among individuals, with only 44% being inflated 91 dph. Additionally, swim bladder inflation did not appear to be size dependent among fish ranging in total length from 61-153 mm at 91 dph. The use of a combination of decompression tests and x-ray radiography was validated as a method to determine initial swim bladder inflation and vulnerability to barotrauma. Extending these techniques to other species and life history stages would help to determine fish susceptibility to hydroturbine passage and aid in fish conservation.

barotrauma↗

Photometry of Outer Solar System Objects from the Dark Energy Survey. I. Photometric Methods, Light-curve Distributions, and Trans-Neptunian Binaries

We report the methods of and initial scientific inferences from the extraction of precision photometric information for the >800 trans-Neptunian objects (TNOs) discovered in the images of the Dark Energy Survey (DES). Scene-modeling photometry is used to obtain shot-noise-limited flux measures for each exposure of each TNO, with background sources subtracted. Comparison of double-source fits to the pixel data with single-source fits are used to identify and characterize two binary TNO systems. A Markov Chain Monte Carlo method samples the joint likelihood of the intrinsic colors of each source as well as the amplitude of its flux variation, given the time series of multiband flux measurements and their uncertainties. A catalog of these colors and light-curve amplitudes A is included with this publication. We show how to assign a likelihood to the distribution q(A) of light-curve amplitudes in any subpopulation. Using this method, we find decisive evidence (i.e., evidence ratio <0.01) that cold classical (CC) TNOs with absolute magnitude 6 < H$_{r}$ < 8.2 are more variable than the hot classical (HC) population of the same H$_{r}$, reinforcing theories that the former form in situ and the latter arise from a different physical population. Resonant and scattering TNOs in this H$_{r}$ range have variability consistent with either the HCs or CCs. DES TNOs with H$_{r}$ < 6 are seen to be decisively less variable than higher-H$_{r}$ members of any dynamical group, as expected. More surprising is that detached TNOs are decisively less variable than scattering TNOs, which requires them to have distinct source regions or some subsequent differential processing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SELF-CONSISTENT ORBITS AND PHYSICAL PROPERTIES FOR EIGHT SINGLE-LINED SPECTROSCOPIC BINARIES

For single-lined spectroscopic binaries (SB1s), self-consistent orbits can be determined via a simultaneous fit including both radial velocity data and the Hipparcos Intermediate Astrometric Data. Using the ratio λ of the semimajor axes of the photocenter to the primary orbits, the present paper develops an iterative fitting method. First, an initial orbit of an SB1 is determined with the assumption that λ equals 1. On the basis of this orbit, we use a stellar evolutionary model to distribute the total mass and luminosity to the primary and the secondary and update λ from the component mass and luminosity ratios. Then the orbit is updated using the updated value of λ, which completes a step of the iterative process. If this process is convergent, the resulting orbit is compatible with the physical properties of component stars. By using this method, the orbital solutions of eight SB1s as well as the physical properties are determined. We find that the component magnitude differences of these systems are very large, except for HIP 7143 and 45333. This suggests that only the secondaries of the two systems can be resolved with the present-day observational techniques, which is in agreement with recent observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Nonunitary Variational Quantum Eigensolver with the Localized Active Space Method and Cost Mitigation

Accurately describing strongly correlated systems with affordable quantum resources remains a central challenge for quantum chemistry applications on near and intermediate term quantum computers. The localized active space self-consistent field (LASSCF) approximates the complete active space self-consistent field (CASSCF) by generating active space-based wave functions within specific fragments while treating interfragment correlation with mean-field approach, hence is computationally less expensive. Hardware-efficient ansatzes (HEA) offer affordable and shallower circuits, yet they often fail to capture the necessary correlation. Previously, Jastrow-factor-inspired nonunitary qubit operators were proposed to use with HEA for variational quantum eigensolver (VQE) calculations (so-called nuVQE), as they do not increase circuit depths and recover correlation beyond the mean-field level for Hartree–Fock initial states. Here, in this study, we explore running nuVQE with LASSCF as the initial state. The method, named LAS-nuVQE, is shown to recover interfragment correlations, reach chemical accuracy with a small number of gates (<70) in both H 4 and square cyclobutadiene (C 4 H 4 ), and produces more accurate energetics than its HEA counterparts at all circuit depths. To further address the inherent symmetry-breaking in HEA, we implemented spin-constrained LAS-nuVQE to extend the capabilities of HEA further and show spin-pure results for square cyclobutadiene. We also mitigate the increased measurement overhead of nuVQE via Pauli grouping and shot-frugal sampling, reducing measurement costs by up to 2 orders of magnitude compared to ungrouped operator, and show that one can achieve better accuracy with a small number of shots (10 3–4 ) per one expectation value calculation compared to noiseless simulations with one or two orders of magnitude more shots. Finally, wall clock time estimates show that, with our measurement mitigation protocols, nuVQE becomes a cheaper and more accurate alternative than vanilla VQE with HEA. Taken together, these developments illustrate a practical pathway toward performing multireference chemical simulations with accuracy and affordable resources on today’s quantum hardware, achieving both accuracy and affordability in challenging correlated systems.

Wang, Qiaohong [Univ. of Chicago, IL (United State↗

Binary-black-hole initial data with nearly extremal spins

There is a significant possibility that astrophysical black holes with nearly extremal spins exist. Numerical simulations of such systems require suitable initial data. In this paper, we examine three methods of constructing binary-black-hole initial data, focusing on their ability to generate black holes with nearly extremal spins: (i) Bowen-York initial data, including standard puncture data (based on conformal flatness and Bowen-York extrinsic curvature), (ii) standard quasiequilibrium initial data (based on the extended-conformal-thin-sandwich equations, conformal flatness, and maximal slicing), and (iii) quasiequilibrium data based on the superposition of Kerr-Schild metrics. We find that the two conformally flat methods (i) and (ii) perform similarly, with spins up to about 0.99 obtainable at the initial time. However, in an evolution, we expect the spin to quickly relax to a significantly smaller value around 0.93 as the initial geometry relaxes. For quasiequilibrium superposed Kerr-Schild data [method (iii)], we construct initial data with initial spins as large as 0.9997. We evolve superposed Kerr-Schild data sets with spins of 0.93 and 0.97 and find that the spin drops by only a few parts in 10{sup 4} during the initial relaxation; therefore, we expect that superposed Kerr-Schild initial data will allow evolutions of binary black holes with relaxed spins above 0.99. Along the way to these conclusions, we also present several secondary results: the power-law coefficients with which the spin of puncture initial data approaches its maximal possible value; approximate analytic solutions for large spin puncture data; embedding diagrams for single spinning black holes in methods (i) and (ii); nonunique solutions for method (ii). All of the initial-data sets that we construct contain subextremal black holes, and when we are able to push the spin of the excision boundary surface into the superextremal regime, the excision surface is always enclosed by a second, subextremal apparent horizon. The quasilocal spin is measured by using approximate rotational Killing vectors, and the spin is also inferred from the extrema of the intrinsic scalar curvature of the apparent horizon. Both approaches are found to give consistent results, with the approximate-Killing-vector spin showing the least variation during the initial relaxation.

79 ASTRONOMY AND ASTROPHYSICS↗