Characterization of SimulCam, a standoff Raman system for scientific support of SuperCam operations on Mars

During the development activities of SuperCam Calibration Target, target intended for one of the two first Raman instruments to be deployed on another planetary body, our group developed a laboratory instrument that could simulate to some extent the Raman capabilities of one of such instruments and could provide data with similar quality. The use of this kind of laboratory instruments has demonstrated its utility in the evaluation of potential calibration targets or anticipating the science outcome that an instrument could provide. The present work describes our laboratory setup to support SuperCam, evaluating similarities between both instruments, despite of differences in the hardware. Evaluation of data gathered by SuperCam on Mars and the availability of one replica of SuperCam’s Calibration Target allowed the comparison on the same set of targets, demonstrating how similar Signal-to-Noise Ratio (SNR) could be achieved from both instruments. The higher energy per pulse on SimulCam is compensated by a greater analytical footprint and the use of smaller collection optics. The results show how spectra obtained at representative distances of SuperCam are comparable. Operational principles are also comparable in terms of time resolution, and close in terms of spectral resolution. This similarity has allowed different science support works using SimulCam data, as well as the support to Mars detections using our setup. We provide examples of this support that will be shared with the community in different papers, as well as examples of possible operations activities that could benefit from experiments performed with SimulCam. We show how this setup can complement the two laboratory replicas in Los Alamos and Toulouse in providing support data to different experiments.

47 OTHER INSTRUMENTATION↗

Reverse image search for scientific data within and beyond the visible spectrum

The explosion in the rate, quality and diversity of image acquisition instruments has propelled the development of expert systems to organize and query image collections more efficiently. Recommendation systems that handle scientific images are rare, particularly if records lack metadata. This paper introduces new strategies to enable fast searches and image ranking from large pictorial datasets with or without labels. The main contribution is the development of pyCBIR, a deep neural network software to search scientific images by content. This tool exploits convolutional layers with locality sensitivity hashing for querying images across domains through a user-friendly interface. Our results report image searches over databases ranging from thousands to millions of samples. We test pyCBIR search capabilities using three convNets against four scientific datasets, including samples from cell microscopy, microtomography, atomic diffraction patterns, and materials photographs to demonstrate 95% accurate recommendations in most cases. Furthermore, all scientific data collections are released.

97 MATHEMATICS AND COMPUTING↗

The development of a 6 Li-based pixelated neutron detector for neutron reflectometry at the Spallation Neutron Source

We present a high-rate 6 Li-based pixelated neutron detector developed for neutron reflectometry instruments at the Spallation Neutron Source (SNS). The neutron detector has a pixelated design: each 6 Li scintillator element has its own photosensor and independent channel readout. This paper focuses on the general overview of the detector design and construction, the characterization of the pixelated detector, and the results of the first neutron reflectivity experiments conducted using the pixelated neutron detector at the SNS Liquid Reflectometer (BL-4B). The pixelated neutron detector demonstrated a global time-average count rate of ≥ 1.8 x 10 6 cps, at least 3 orders of magnitude higher than that of the existing neutron detector ( 3 He-based Multi-Wire Proportional Counter), and a local instantaneous count rate of ≥ 1.73 x 10 6 cps / cm 2 . The maximum counting rate of the detector has not yet been determined as the detector is capable of handling the maximum flux available at the beamline. Furthermore, the outcome of the neutron reflectivity experiments showed that the pixelated neutron detector is a promising candidate for next-generation neutron reflectometry instruments at the SNS.

6Li, silicon photomultiplier↗

Tandem Mass-Selective Cryogenic Digital Ion Traps for Enhanced Cluster Formation

We present the implementation of tandem mass-selective cryogenic ion traps, designed to enhance the range of ion processing capabilities that can be performed prior to spectroscopic interrogation. We show that both the formation of ion clusters and mass filtering steps can be combined in a single cryogenic linear quadrupole ion trap driven by RF square waves. Mass filtering and mass isolation can be achieved by manipulation of the RF frequency and duty cycle. Very importantly, this scheme circumvents the need for high-amplitude RF voltages that can be incompatible with typical cryogenic ion processing conditions. In addition, proper adjustment of the stability boundaries during the clustering process allows for the preferential formation of a specific cluster size rather than a broad distribution of sizes. Lastly, we show that a specific cluster size can be formed, mass-selected, and then transferred to another ion trap for a second completely separate ion processing step. Furthermore, the instrumentation and modular design developed here expand the scope of ionic species and clusters that can be accessed by processing electrosprayed ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray Photoelectron Spectroscopy Analysis of Nafion-Containing Samples: Pitfalls, Protocols, and Perceptions of Physicochemical Properties

X-ray photoelectron spectroscopy (XPS) is one of the most common techniques used to analyze the surface composition of catalysts and support materials used in polymer electrolyte membrane (PEM) fuel cells and electrolyzers, providing important insights for further improvement of their properties. Characterization of catalyst layers (CLs) is more challenging, which can be at least partially attributed to the instability of ionomer materials such as Nafion during measurements. This work explores the stability of Nafion during XPS measurements, illuminating and addressing Nafion degradation concerns. The extent of Nafion damage as a function of XPS instrumentation, measurement conditions, and sample properties was evaluated across multiple instruments. Results revealed that significant Nafion damage to the ion-conducting sulfonic acid species (>50% loss in sulfur signal) may occur in a relatively short time frame (tens of minutes) depending on the exact nature of the sample and XPS instrument. This motivated the development and validation of a multipoint XPS data acquisition protocol that minimizes Nafion damage, resulting in reliable data acquisition by avoiding significant artifacts from Nafion instability. The developed protocol was then used to analyze both thin film ionomer samples and Pt/C-based CLs. Comparison of PEM fuel cell CLs to Nafion thin films revealed several changes in Nafion spectral features attributed to charge transfer due to interaction with conductive catalyst and support species. This study provides a method to reliably characterize ionomer-containing samples, facilitating fundamental studies of the catalyst-ionomer interface and more applied investigations of structure-processing-performance correlations in PEM fuel cell and electrolyzer CLs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Achievements and Prospects of Global Broadband Seismographic Networks After 30 Years of Continuous Geophysical Observations

Global seismographic networks (GSNs) emerged during the late nineteenth and early twentieth centuries, facilitated by seminal international developments in theory, technology, instrumentation, and data exchange. The mid- to late-twentieth century saw the creation of the World-Wide Standardized Seismographic Network (1961) and International Deployment of Accelerometers (1976), which advanced global geographic coverage as seismometer bandwidth increased greatly allowing for the recording of the Earth's principal seismic spectrum. The modern era of global observations and rapid data access began during the 1980s, and notably included the inception of the GEOSCOPE initiative (1982) and GSN (1988). Through continual improvements, GEOSCOPE and the GSN have realized near-real time recording of ground motion with state-of-art data quality, dynamic range, and timing precision to encompass 180 seismic stations, many in very remote locations. Data from GSNs are increasingly integrated with other geophysical data (e.g., space geodesy, infrasound and Interferometric Synthetic Aperture Radar). Globally distributed seismic data are critical to resolving crust, mantle, and core structure; illuminating features of the plate tectonic and mantle convection system; rapid characterization of earthquakes; identification of potential tsunamis; global nuclear test verification; and provide sensitive proxies for environmental changes. As the global geosciences community continues to advance our understanding of Earth structure and processes controlling elastic wave propagation, GSN infrastructure offers a springboard to realize increasingly multi-instrument geophysical observatories. Here, we review the historical, scientific, and monitoring heritage of GSNs, summarize key discoveries, and discuss future associated opportunities for Earth Science.

58 GEOSCIENCES↗

Isotope-resolved atomic beam laser spectroscopy of natural uranium

Here, we present our results on the development of a technique for conducting laser absorption spectroscopy of uranium in a collimated atomic beam using a compact and potentially fieldable device. A solid natural uranium metal sample is vaporized in a modest vacuum of several mTorr via resistive heating of a tantalum foil micro-crucible. A temperature of over 2000 °C is reached by applying only 200 W of electrical power to the crucible. At this temperature, the vapor pressure of uranium is large enough to generate a stable atomic beam. A diode laser is tuned around the 861.031 nm uranium transition, which allows the observation of absorption bands from both the 238 U and 235 U isotopes. The isotopic composition of uranium Standard Reference Material 960 is obtained from the absorption signal, in excellent agreement with the nominal value. In conclusion, our approach can be readily applied to the isotopic analysis of other actinides, and it is expected to lead to the development of compact, fieldable instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-Ray Imaging and Spectroscopy Mission

The X-Ray Imaging and Spectroscopy Mission (XRISM) is a joint mission between the Japan Aerospace Exploration Agency (JAXA) and the National Aeronautics and Space Administration (NASA) in collaboration with the European Space Agency (ESA). In addition to the three space agencies, universities and research institutes from Japan, North America, and Europe have joined to contribute to developing satellite and onboard instruments, data-processing software, and the scientific observation program. XRISM is the successor to the ASTRO-H (Hitomi) mission, which ended prematurely in 2016. Its primary science goal is to examine astrophysical problems with precise, high-resolution X-ray spectroscopy. XRISM promises to discover new horizons in X-ray astronomy. It carries a 6 × 6 pixelized X-ray microcalorimeter on the focal plane of an X-ray mirror assembly (Resolve) and a co-aligned X-ray CCD camera (Xtend) that covers the same energy band over a large field of view. XRISM utilizes the Hitomi heritage, but all designs were reviewed. The attitude and orbit control system was improved in hardware and software. The spacecraft was launched from the JAXA Tanegashima Space Center on 2023 September 6 (UTC). During the in-orbit commissioning phase, the onboard components were activated. Although the gate valve protecting the Resolve sensor with a thin beryllium X-ray entrance window was not yet opened, scientific observation started in 2024 February with the planned performance verification observation program. The nominal observation program commenced with the following guest observation program beginning in 2024 September.

Astronomy and AstroPhysics↗

Accounting for spectroscopic effects in laser‐based open‐path eddy covariance flux measurements

Abstract A significant portion of the production and consumption of trace gases (e.g. CO 2 , CH 4 , N 2 O, NH 3 , etc.) by world ecosystems occurs in areas without sufficient infrastructure or easily available grid power to run traditional closed‐path flux stations. Open‐path analyzer design allows such measurements with power consumption 10–150 times below present closed‐path technologies, helping to considerably expand the global coverage and improve the estimates of gas emissions and budgets, informing the remote sensing and modeling communities and policy decisions, all the way to IPCC reports. Broad‐band nondispersive infrared devices have been used for open‐path CO 2 and H 2 O measurements since the late 1970s, but since recently, a growing number of new narrow‐band laser‐based instruments are being rapidly developed. The new design comes with its own challenges, specifically: (a) mirror contamination, and (b) uncontrolled air temperature, pressure and humidity, affecting both the gas density and the laser spectroscopy of the measurements. While the contamination can be addressed via automated cleaning, and density effects can be addressed via the Webb‐Pearman‐Leuning approach, the spectroscopic effects of the in situ temperature, pressure and humidity fluctuations on laser‐measured densities remain a standing methodological question. Here we propose a concept accounting for such effects in the same manner as Webb et al. proposed to account for respective density effects. Derivations are provided for a general case of flux of any gas, examined using a specific example of CH 4 fluxes from a commercially available analyzer, and then tested using “zero‐flux” experiment. The proposed approach helps reduce errors in open‐path, enclosed, and temperature‐ or pressure‐uncontrolled closed‐path laser‐based flux measurements due to the spectroscopic effects from few percents to multiple folds, leading to methodological advancement and geographical expansion of the use of such systems providing reliable and consistent results for process‐level studies, remote sensing and Earth modeling applications, and GHG policy decision‐making.

Burba, George↗

Optimization of X-ray event screening using ground and in-orbit data for the Resolve instrument onboard the XRISM satellite

The X-Ray Imaging and Spectroscopy Mission (XRISM) satellite was successfully launched and put into a low-Earth orbit on September 6, 2023 (UT). The Resolve instrument onboard XRISM hosts an X-ray microcalorimeter detector, which was designed to achieve a high-resolution ( ≤ 7 eV FWHM at 6 keV), high-throughput, and non-dispersive spectroscopy over a wide energy range. It also excels in a low background with a requirement of < 2 × 10 -3 s -1 keV -1 (0.3 to 12.0 keV), which is equivalent to only one background event per spectral bin per 100-ks exposure. Event screening to discriminate X-ray events from background is a key to meeting the requirement. We present the result of the Resolve event screening using data sets recorded on the ground and in orbit based on the heritage of the preceding X-ray microcalorimeter missions, in particular, the Soft X-ray Spectrometer onboard ASTRO-H. We optimize and evaluate 19 screening items of three types based on (1) the event pulse shape, (2) relative arrival times among multiple events, and (3) good time intervals. We show that the initial screening, which is applied for science data products in the performance verification phase, reduces the background rate to 1.8 × 10 -3 s -1 keV -1 meeting the requirement. We further evaluate the additional screening utilizing the correlation among some pulse shape properties of X-ray events and show that it further reduces the background rate, particularly in the < 2 keV band. Over 0.3 to 12 keV, the background rate becomes 1.0 × 10 -3 s -1 keV -1 .

47 OTHER INSTRUMENTATION↗

Dispersion of the refractive index in high-k dielectrics

A brief review of the optical properties of oxide materials that are used at present as dielectrics in modern microelectronics is presented. Using spectral ellipsometry, dispersion dependencies for different materials are measured. A brief comparative analysis of different dielectric coatings is carried out. The results of our research will be useful in further studies of the properties of dielectrics, as well as in technologies that are employed in the development of new semiconductor instruments and devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cloud System Evolution in the Trades (CSET): Following the Evolution of Boundary Layer Cloud Systems with the NSF–NCAR GV

The Cloud System Evolution in the Trades (CSET) study was designed to describe and explain the evolution of the boundary layer aerosol, cloud, and thermodynamic structures along trajectories within the North Pacific trade winds. The study centered on seven round trips of the National Science Foundation–National Center for Atmospheric Research (NSF–NCAR) Gulfstream V (GV) between Sacramento, California, and Kona, Hawaii, between 7 July and 9 August 2015. The CSET observing strategy was to sample aerosol, cloud, and boundary layer properties upwind from the transition zone over the North Pacific and to resample these areas two days later. Global Forecast System forecast trajectories were used to plan the outbound flight to Hawaii with updated forecast trajectories setting the return flight plan two days later. Two key elements of the CSET observing system were the newly developed High-Performance Instrumented Airborne Platform for Environmental Research (HIAPER) Cloud Radar (HCR) and the high-spectral-resolution lidar (HSRL). Together they provided unprecedented characterizations of aerosol, cloud, and precipitation structures that were combined with in situ measurements of aerosol, cloud, precipitation, and turbulence properties. The cloud systems sampled included solid stratocumulus infused with smoke from Canadian wildfires, mesoscale cloud–precipitation complexes, and patches of shallow cumuli in very clean environments. Ultraclean layers observed frequently near the top of the boundary layer were often associated with shallow, optically thin, layered veil clouds. In conclusion, the extensive aerosol, cloud, drizzle, and boundary layer sampling made over open areas of the northeast Pacific along 2-day trajectories during CSET will be an invaluable resource for modeling studies of boundary layer cloud system evolution and its governing physical processes.

54 ENVIRONMENTAL SCIENCES↗

Are Atmospheric Models Too Cold in the Mountains? The State of Science and Insights from the SAIL Field Campaign

Mountains play an outsized role in water resource availability, and the amount and timing of water they provide depend strongly on temperature. To that end, we ask the question: How well are atmospheric models capturing mountain temperatures? We synthesize results showing that high-resolution, regionally relevant climate models produce 2-m air temperature (T2m) measurements colder than what is observed (a “cold bias”), particularly in snow-covered midlatitude mountain ranges during winter. We find common cold biases in 44 studies across global mountain ranges, including single-model and multimodel ensembles. We explore the factors driving these biases and examine the physical mechanisms, data limitations, and observational uncertainties behind T2m. Our analysis suggests that the biases are genuine and not due to observation sparsity or resolution mismatches. Cold biases occur primarily on mountain peaks and ridges, whereas valleys are often warm biased. Our literature review suggests that increasing model resolution does not clearly mitigate the bias. By analyzing data from the Surface Atmosphere Integrated Field Laboratory (SAIL) field campaign in the Colorado Rocky Mountains, we test various hypotheses related to cold biases and find that local wind circulations, longwave (LW) radiation, and surface-layer parameterizations contribute to the T2m biases in this particular location. We conclude by emphasizing the value of coordinated model evaluation and development efforts in heavily instrumented mountain locations for addressing the root cause(s) of T2m biases and improving predictive understanding of mountain climates.

54 ENVIRONMENTAL SCIENCES↗

Are Atmospheric Models Too Cold in the Mountains? The State of Science and Insights from the SAIL Field Campaign

Mountains play an outsized role in water resource availability, and the amount and timing of water they provide depend strongly on temperature. To that end, we ask the question: How well are atmospheric models capturing mountain temperatures? We synthesize results showing that high-resolution, regionally relevant climate models produce 2-m air temperature (T2m) measurements colder than what is observed (a “cold bias”), particularly in snow-covered midlatitude mountain ranges during winter. We find common cold biases in 44 studies across global mountain ranges, including single-model and multimodel ensembles. We explore the factors driving these biases and examine the physical mechanisms, data limitations, and observational uncertainties behind T2m. Our analysis suggests that the biases are genuine and not due to observation sparsity or resolution mismatches. Cold biases occur primarily on mountain peaks and ridges, whereas valleys are often warm biased. Our literature review suggests that increasing model resolution does not clearly mitigate the bias. By analyzing data from the Surface Atmosphere Integrated Field Laboratory (SAIL) field campaign in the Colorado Rocky Mountains, we test various hypotheses related to cold biases and find that local wind circulations, longwave (LW) radiation, and surface-layer parameterizations contribute to the T2m biases in this particular location. We conclude by emphasizing the value of coordinated model evaluation and development efforts in heavily instrumented mountain locations for addressing the root cause(s) of T2m biases and improving predictive understanding of mountain climates.

54 ENVIRONMENTAL SCIENCES↗

Irradiation Characterization of Pressure Transducers

The advancement of reactor technologies for space and remote applications requires further investigation into the long-term operation of instrumentation without the chance for standard scheduled maintenance. Specifically, the degradation of instrumentation due to exposure to nuclear radiation needs to be understood. Determining the methods of degradation can improve material selection for instrument construction and provide foundational data for the development of corrective algorithms. Initial work has been focused on the development of nuclear thermal rocket technology and the instrumentation needs that will led to its eventual deployment.

Floyd, Dan↗

In-Pile Instrumentation Advanced Manufacturing: Devleopment of Pt, Mo, and Nb Inks

This report summarizes the nanoparticle ink synthesis for in–pile nuclear sensor applications. Bulk nanopowders of Pt, Mo, and Nb were dispersed in aqueous solvents and printed into in–pile nuclear sensor structures to demonstrate their compatibility with aerosol jet printing and plasma jet printing. While we did not directly demonstrate plasma jet printing, due to delays in equipment installation from the manufacturer, compatibility with aerosol jet printing technology is expected to transfer to the plasma jet printer based upon the manufacturer’s specifications for ink compatibility.

36 MATERIALS SCIENCE↗

Status of Mock-up and Integration for Ultrasonic Deformation Sensor for TREAT Experiments

Fuel deformation (both axial and radial) information provides insights into fuel performance and failure limits. Traditionally, fuel deformation has been quantified using post-irradiation examinations due to the lack of an appropriate sensor for monitoring deformation in situ. Recent developments in sensor and instrumentation design have led to the use of linear variable differential transducers (LVDT) for monitoring axial strain in fuel during irradiation. Size and operational constraints limit the use of LVDT sensors for radial deformation monitoring, and alternatives are needed. One possible alternative to LVDT sensors is an ultrasonic sensor. Ultrasonic sensors monitor the interaction of high-frequency stress waves with the test object. The resulting response may be analyzed to determine the properties of the material, including stress, strain, microstructure, presence of defects, and the elastic constants. While ultrasonic measurements have been successfully applied for monitoring strain in a number of applications, their use for in-core measurements has been limited. Largely, the limitations are due to the challenges associated with designing sensors that can operate under typical in-core conditions. This report documents progress to date toward planning, construction, and testing of a mock-up test capsule/facility to be used for in-lab testing of ultrasonic displacement sensor designs and toward integration of the sensor into prototypic TREAT experiment designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration Testing of Ultrasonic Deformation Sensor for TREAT Experiments

Fuel deformation (both axial and radial) information provides insights into fuel performance and failure limits. Traditionally, fuel deformation has been quantified using post-irradiation examinations due to the lack of an appropriate sensor for monitoring deformation in situ. Recent developments in sensor and instrumentation design have led to the use of linear variable differential transformers (LVDT) for monitoring axial strain in fuel during irradiation. Size and operational constraints limit the use of LVDT sensors for radial deformation monitoring, and alternatives are needed. One possible alternative to LVDT sensors is an ultrasonic sensor. Ultrasonic sensors monitor the interaction of high-frequency stress waves with the test object. The resulting response may be analyzed to determine the properties of the material, including stress, strain, microstructure, presence of defects, and the elastic constants. While ultrasonic measurements have been successfully applied for monitoring strain in a number of applications, their use for in-core measurements has been limited. Largely, the limitations are due to the challenges associated with designing sensors that can operate under typical in-core conditions. This report documents testing performed to confirm that the prototypic ultrasonic deformation sensor can be integrated into TREAT irradiation experiments using the SETH capsule.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗