Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instrument Procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Gravimetric maps of the Central African Republic

Gravimetric maps of the Central African Republic are described including a map of Bouguer anomalies at 1/1,000,000 in two sections (eastern sheet, western sheet) and a map, in color, of Bouguer anomalies at 1/2,000,000. Instrumentation, data acquisition, calibration, and data correction procedures are discussed.

Albouy, J.↗

Production and analysis of output data products for Landsat-4 in the engineering check-out phase

The Landsat-D (now Landsat-4) program was initiated by NASA in the mid-1970's. The spacecraft was launched on July 16, 1982. Instruments on the satellite include the fourth Multispectral Scanner (MSS) and the new higher-resolution Thematic Mapper (TM). In order to achieve the planned engineering and scientific objectives, attention has to be given to the validation of spacecraft and instrument performance, the adjustment of ground processing procedures, and the definition of the measures of the TU utility. To satisfy these requirements, a Landsat Assessment System (LAS) was conceived, and the Applications Developmental Data System (ADDS) was instituted. The set of component systems collectively became known as the 'Scrounge' system. The present investigation is concerned with the Scrounge system and the results of radiometric and geometric data evaluations. Attention is given to the TM geometric correction, TM data resampling, a radiometric correction functional description, and the results of the TM geometric and radiometric correction.

Lyon, J. C.↗

Launch operations of the SSME

The mission profile, performance over the first eight flights, and inspection and repair procedures for the Shuttle main engines (SSME) are outlined. The Orbiter has three SSMEs, each delivering 470,000 lb thrust at rated level and 512,000 lb thrust at full power level. The engines each have a design lifetime of 55 launches and 27,000 sec operating life. After eight STS flights the SSME maintenance requirements and part replacements have generally followed those experiences during ground tests, i.e., routine checkout of some items are performed every flight, some after a few flights, and replacements are made as needed or scheduled. Hot-fire tests are performed only if a generic defect has been recognized and corrective action taken. Attention is also given to engine sensors to verify functioning status. Details of the inspection procedures, unscheduled maintenance, and inspection tools and instruments are provided.

Klatt, F. P.↗

Radiocarbon tracer measurements of atmospheric hydroxyl radical concentrations

The usefulness of the C-14 tracer in measurements of atmospheric hydroxyl radical concentration is discussed. The apparatus and the experimental conditions of three variations of a radiochemical method of atmosphere analysis are described and analyzed: the Teflon bag static reactor, the flow reactor (used in the Wallops Island tests), and the aircraft OH titration reactor. The procedure for reduction of the aircraft reactor instrument data is outlined. The problems connected with the measurement of hydroxyl radicals are discussed. It is suggested that the gas-phase radioisotope methods have considerable potential in measuring tropospheric impurities present in very low concentrations.

Campbell, M. J.↗

Balloon Intercomparison Campaigns - Results of remote sensing measurements of HCl

The balloon-borne instruments used in the two Balloon Intercomparison Campaigns in 1982 and 1983 to measure stratospheric HCl included five different IR spectrometers, three of which operated in the solar absorption mode and two in emission mode (at distinctly different wavelengths). This paper describes the instruments and the data reduction and analysis procedures used in each case, together with the sources and estimated magnitudes of associated errors. Comparisons are made between different techniques (absorption vs emission) used on the same gondola, as well as between the same technique used on different gondolas. The final results yield a mean profile of HCl concentration between 18 and 40 km altitude. The absolute accuracy of the final profile is estimated to be no worse than 10 percent.

Farmer, C. B.↗

A numerical algorithm to propagate navigation error covariance matrices associated with generalized strapdown inertial measurement units

The design and operation of a Strapdown Navigation Analysis Program (SNAP) developed to perform covariance analysis on spacecraft inertial-measurement-unit (IMU) navigation errors are described and demonstrated. Consideration is given to the IMU modeling subroutine (with user-specified sensor characteristics), the data input procedures, state updates and the simulation of instrument failures, the determination of the nominal trajectory, the mapping-matrix and Monte Carlo covariance-matrix propagation methods, and aided-navigation simulation. Numerical results are presented in tables for sample applications involving (1) the Galileo/IUS spacecraft from its deployment from the Space Shuttle to a point 10 to the 8th ft from the center of the earth and (2) the TDRS-C/IUS spacecraft from Space Shuttle liftoff to a point about 2 h before IUS deployment. SNAP is shown to give reliable results for both cases, with good general agreement between the mapping-matrix and Monte Carlo predictions.

Weir, Kent A.↗

Evolution of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) flight and ground data processing system

The modifications made to both the AVIRIS instrument and the data processing facility since the instrument made its initial flight in the summer of 1987 are described. Historical development of the data system is discussed and attention is given to enhancements to instrument stability and noise performance. AVIRIS data facility objectives include rapid and automated decommutation and archiving of data, the ability to assess the quality of the data and health of the instrument, and the provision of an automated procedure for applying radiometric corrections to the data and providing responsive processing of data requests from investigators. The modifications described have resulted in an overall radiometric stability of better than 10 percent, with stability of only a few percent during a single flight.

Porter, Wallace M.↗

Aerosol and cloud observations with a CO2 backscatter lidar on the NASA DC-8 GLOBE Pacific Missions

The paper presents an airborne backscatter lidar developed to fly multiple times on the NASA DC-8 research aircraft and measure vertical profiles of aerosol and cloud backscatter throughout the vertical extent of the troposphere, with emphasis on coverage of the range of latitudes. The lidar instrument characteristics are summarized and the calibration procedures are described. Results of aerosol and cloud observations are presented.

Menzies, Robert T.↗

SAO mission support software and data standards, version 1.0

This document defines the software developed by the SAO AXAF Mission Support (MS) Program and defines standards for the software development process and control of data products generated by the software. The SAO MS is tasked to develop and use software to perform a variety of functions in support of the AXAF mission. Software is developed by software engineers and scientists, and commercial off-the-shelf (COTS) software is used either directly or customized through the use of scripts to implement analysis procedures. Software controls real-time laboratory instruments, performs data archiving, displays data, and generates model predictions. Much software is used in the analysis of data to generate data products that are required by the AXAF project, for example, on-orbit mirror performance predictions or detailed characterization of the mirror reflection performance with energy.

Hsieh, P.↗

Oscillating-flow regenerator test rig

This report summarizes work performed in setting up and performing tests on a regenerator test rig. An earlier status report presented test results, together with heat transfer correlations, for four regenerator samples (two woven screen samples and two felt metal samples). Lessons learned from this testing led to improvements to the experimental setup, mainly instrumentation as well as to the test procedure. Given funding and time constraints for this project it was decided to complete as much testing as possible while the rig was set up and operational, and to forego final data reduction and analysis until later. Additional testing was performed on several of the previously tested samples as well an on five newly fabricated samples. The following report is a summary of the work performed at OU, with many of the final test results included in raw data form.

Wood, J. G.↗

Simulation of landsat thematic mapper imagery using AVIRIS hyperspectral imagery

In this paper we present a methodology for simulating multispectral imagery (MSI) using hyperspectral imagery (HSI), and present a validation of the technique using one nearly coincident Landsat TM and AVIRIS data set. Generation of MSI from HSI supports several investigations including selection of multispectral sensor band edges, and engineering trade studies related to on-board or ground-based aggregation of HSI to simulate MSI. In addition, the utility of this technique as a potential procedure for monitoring calibration changes in spaceborne instrument is also addressed.

Kalman, Linda S.↗

Dynamic Stability Instrumentation System (DSIS): User Manual - Volume 3

The paper is an operating manual for the Dynamic Stability Instrumentation System in specific NASA Langley wind tunnels. The instrumentation system performs either a synchronous demodulation or a Fast Fourier Transform on dynamic balance strain gage signals, and ultimately computes aerodynamic coefficients. The dynamic balance converts sting motor rotation into pitch or yaw plane or roll axis oscillation, with timing information provided by a shaft encoder. Additional instruments control model attitude and balance temperature and monitor sting vibrations. Other instruments perform self-calibration and diagnostics. Procedures for conducting calibrations and wind-off and wind-on tests are listed.

Daniels, Taumi S.↗

Upward Flame Propagation and Wire Insulation Flammability: 2006 Round Robin Data Analysis

This viewgraph document reviews test results from tests of different material used for wire insulation for flame propagation and flammability. The presentation focused on investigating data variability both within and between laboratories; evaluated the between-laboratory consistency through consistency statistic h, which indicates how one laboratory s cell average compares with averages from other labs; evaluated the within-laboratory consistency through the consistency statistic k, which is an indicator of how one laboratory s within-laboratory variability compares with the variability of other labs combined; and extreme results were tested to determine whether they resulted by chance or from nonrandom causes (human error, instrument calibration shift, non-adherence to procedures, etc.)

Hirsch, David B.↗

TPSAS-NF1676L-31382-DND

Agenda - Review: Data Analysis - Review: Aeroelasticity & ASE - Motivation and Test objectives - Transonic Dynamics Tunnel - Model Design and Fabrication - Model Instrumentation - Model Validation (GVT, Stiffness, …) - Model Testing Procedure - Case Studies

Walter A. Silva↗

The Mg 280-nm doublet as a monitor of changes in solar ultraviolet irradiance

Solar irradiance data gathered with the Nimbus 7 spacecraft from 1978-1985 are compared with atmospheric MG 289-nm doublet emission line data to evaluate the possibility of using the rotational line data to calculate the total solar UV input. The satellite instrumentation is described, including the calibration equipment and procedures. The spacecraft records solar irradiance once per day and the remainder of the time records irradiance scattered by the atmosphere. The measured irradiances are converted to equivalent brightness temperatures, which can be interpolated for specific layers of the atmosphere. Sample daily data are provided to illustrate the correlation between variations in the Mg-II core radiation and the soalr UV irradiance. Techniques are defined for correcting for periodic variations in instrument performance to quantify long-term solar UV radiance variations. Using the atmospheric Mg-II doublet radiation for measuring soalr UV irradiance is concluded of value for characterizing the effects of solar radiation on the atmosphere.

Heath, D. F.↗

Laser light scattering instrument advanced technology development

The objective of this advanced technology development (ATD) project has been to provide sturdy, miniaturized laser light scattering (LLS) instrumentation for use in microgravity experiments. To do this, we assessed user requirements, explored the capabilities of existing and prospective laser light scattering hardware, and both coordinated and participated in the hardware and software advances needed for a flight hardware instrument. We have successfully breadboarded and evaluated an engineering version of a single-angle glove-box instrument which uses solid state detectors and lasers, along with fiber optics, for beam delivery and detection. Additionally, we have provided the specifications and written verification procedures necessary for procuring a miniature multi-angle LLS instrument which will be used by the flight hardware project which resulted from this work and from this project's interaction with the laser light scattering community.

Wallace, J. F.↗

Optimization studies for the development of adaptive wall wind tunnel

The development of adaptive wall wind tunnels makes it possible to establish interference-free boundaries in the region of the model. It is, therefore, feasible to simulate free air conditions. However, the amount of total testing time involved in establishing the required conditions and the complexity of the needed instrumentation prevent currently the use of such methods for routine production testing. Optimization studies have been proposed with the objective to find approaches which will make a more extended application of adaptive wall techniques possible. A new 25cm x 11cm adaptive wall test section was designed and installed to carry out some of these studies. Investigations envisaged are related to the development of a one step convergence method to reduce total testing time, and to measurement procedures which will permit a simplification of the instrumentation. Attention is given to the proposed concept, the test section, instrumentation, and the influence coefficients.

Bodapati, S.↗