Search NASA⌕ Search

SEARCH · Search NASA

Results for “LASER TARGETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Orbital Express Advanced Video Guidance Sensor

In May 2007 the first US fully autonomous rendezvous and capture was successfully performed by DARPA's Orbital Express (OE) mission. Since then, the Boeing ASTRO spacecraft and the Ball Aerospace NEXTSat have performed multiple rendezvous and docking maneuvers to demonstrate the technologies needed for satellite servicing. MSFC's Advanced Video Guidance Sensor (AVGS) is a primary near-field proximity operations sensor integrated into ASTRO's Autonomous Rendezvous and Capture Sensor System (ARCSS), which provides relative state knowledge to the ASTRO GN&C system. This paper provides an overview of the AVGS sensor flying on Orbital Express, and a summary of the ground testing and on-orbit performance of the AVGS for OE. The AVGS is a laser-based system that is capable of providing range and bearing at midrange distances and full six degree-of-freedom (6DOF) knowledge at near fields. The sensor fires lasers at two different frequencies to illuminate the Long Range Targets (LRTs) and the Short Range Targets (SRTs) on NEXTSat. Subtraction of one image from the other image removes extraneous light sources and reflections from anything other than the corner cubes on the LRTs and SRTs. This feature has played a significant role for Orbital Express in poor lighting conditions. The very bright spots that remain in the subtracted image are processed by the target recognition algorithms and the inverse-perspective algorithms, to provide 3DOF or 6DOF relative state information. Although Orbital Express has configured the ASTRO ARCSS system to only use AVGS at ranges of 120 m or less, some OE scenarios have provided opportunities for AVGS to acquire and track NEXTSat at greater distances. Orbital Express scenarios to date that have utilized AVGS include a berthing operation performed by the ASTRO robotic arm, sensor checkout maneuvers performed by the ASTRO robotic arm, 10-m unmated operations, 30-m unmated operations, and Scenario 3-1 anomaly recovery. The AVGS performed very well during the pre-unmated operations, effectively tracking beyond its 10-degree Pitch and Yaw limit-specifications, and did not require I-LOAD adjustments before unmated operations. AVGS provided excellent performance in the 10-m unmated operations, effectively tracking and maintaining lock for the duration of this scenario, and showing good agreement between the short and long range targets. During the 30-m unmated operations, the AVGS continuously tracked the SRT to 31.6 m, exceeding expectations, and continuously tracked the LRT from 8.8 m out to 31.6 m, with good agreement between these two target solutions. After this scenario was aborted at a 10-m separation during remate operations, the AVGS tracked the LRT out 54.3 m, until the relative attitude between the vehicles was too large. The vehicles remained apart for eight days, at ranges from 1 km to 6 km. During the approach to remate in this recovery operation, the AVGS began tracking the LRT at 150 m, well beyond the OE planned limits for AVGS ranges, and functioned as the primary sensor for the autonomous rendezvous and docking.

Howard, Ricky↗

Low Power Consumption Lasers for Next Generation Miniature Optical Spectrometers for Major Constituent and Trace Gas Analysis

The air quality of any manned spacecraft needs to be continuously monitored in order to safeguard the health of the crew. Air quality monitoring grows in importance as mission duration increases. Due to the small size, low power draw, and performance reliability, semiconductor laser-based instruments are viable candidates for this purpose. The minimum instrument size requires lasers with emission wavelength coinciding with the absorption of the fundamental frequency of the target gases which are mostly in the 3.0-5.0 micrometers wavelength range. In this paper we report on our progress developing high wall plug efficiency type-I quantum-well GaSb-based diode lasers operating at room temperatures in the spectral region near 3.0-3.5 micrometers and quantum cascade (QC) lasers in the 4.0-5.0 micrometers range. These lasers will enable the development of miniature, low-power laser spectrometers for environmental monitoring of the spacecraft.

semiconductor lasers↗

A Gene Expression and Histologic Approach to Study Production and Outflow of Cerebrospinal Fluid in Hindlimb Suspended Rats

INTRODUCTION: The Spaceflight Associated Neuro-ocular Syndrome (SANS) is thought to be associated with weightlessness-induced cephalad fluid shift, possibly associated with a chronic elevation of intracranial pressure (ICP) during long-duration ISS missions. Changes in cerebrospinal fluid (CSF) dynamics and cranial compliance might be involved in the ICP increase. It is not known whether CSF production and/or outflow are altered in microgravity, but changes at the molecular and cellular level in the structures that produce and regulate the transcellular and paracellular secretion and reabsorption of CSF may be relevant. In this study, we used the rat hindlimb suspension (HS) model to examine the relationship between intracranial pressure (ICP) and the cellular responses to the prolonged change in body posture elicited specifically in the choroid plexus (CP). This was evaluated by transcriptomics, histopathology and ultrastructure of the CP and arachnoid villi (AV). METHODS: ICP was measured by telemetry. The morphology, ultrastructure, and gene expression profile of the CP was examined using male 9-month-old Long Evans rats subjected to HS for 14 and 90 days. A subset of animals completing 90-day HS returned to normal posture for 14 and 90 additional days of recovery. All HS rats had age-matched cage controls maintained in normal posture. A group of animals was maintained in conditions of 1% CO2 throughout the entire protocol. The rat brains were carefully removed and preserved for various analyses, including transmission electron microscopy (TEM), immunohistochemical analysis of specific targets involved in CSF regulation, and RNA sequencing analysis of laser capture micro-dissected CP tissue from the lateral ventricles. SUMMARY OF RESULTS: The ICP record was limited, which impacted any conclusions derived from the results. However, the ICP of rats in the CO2-enriched atmosphere appeared increased compared to those in a normal air composition. HS of rats resulted in an altered transcriptomics profile in the choroid plexus compared to animals maintained at normal posture. This was observed during both the HS period and during normal posture recovery period following 90 days of suspension. The greatest number of differentially expressed genes was observed at 90 days HS. Elevated CO2 also led to a different transcriptomics profile in the CP. The histology and ultrastructure results should be considered preliminary due to the limited number of samples. Examination of the CP by TEM showed blood vessel congestion and microvilli swelling in the CP, as well as some subpial and periventricular gliosis, but no associations were observed with treatment. There was no evidence of a reduced clearance of b-amyloid in the periventricular, perivascular and subpial regions of the brain in HS animals versus those in normal posture. Immunohistochemical staining of aquaporin 4, showed the localization to the subpial region and ependyma with increased immunoreactivity in the brains of CO2 exposed rats. This work was supported by awards NNX15AW48G to S.Z. Animal tissue and live data was provided under a tissue/data sharing agreement with Dr. Charles Fuller, UC Davis.

S B Zanello↗

A Gene Expression and Histologic Approach to Study Production and Outflow of Cerebrospinal Fluid in Hindlimb Suspended RATS

INTRODUCTION: The Spaceflight Associated Neuro-ocular Syndrome (SANS) is thought to be associated with weightlessness-induced cephalad fluid shift, possibly associated with a chronic elevation of intracranial pressure (ICP) during long-duration ISS missions. Changes in cerebrospinal fluid (CSF) dynamics and cranial compliance might be involved in the ICP increase. It is not known whether CSF production and/or outflow are altered in microgravity, but changes at the molecular and cellular level in the structures that produce and regulate the transcellular and paracellular secretion and reabsorption of CSF may be relevant. In this study, we used the rat hindlimb suspension (HS) model to examine the relationship between intracranial pressure (ICP) and the cellular responses to the prolonged change in body posture elicited specifically in the choroid plexus (CP). This was evaluated by transcriptomics, histopathology and ultrastructure of the CP and arachnoid villi (AV). METHODS: ICP was measured by telemetry. The morphology, ultrastructure, and gene expression profile of the CP was examined using male 9-month-old Long Evans rats subjected to HS for 14 and 90 days. A subset of animals completing 90-day HS returned to normal posture for 14 and 90 additional days of recovery. All HS rats had age-matched cage controls maintained in normal posture. A group of animals was maintained in conditions of 1% CO2 throughout the entire protocol. The rat brains were carefully removed and preserved for various analyses, including transmission electron microscopy (TEM), immunohistochemical analysis of specific targets involved in CSF regulation, and RNA sequencing analysis of laser capture micro-dissected CP tissue from the lateral ventricles. SUMMARY OF RESULTS: The ICP record was limited, which impacted any conclusions derived from the results. However, the ICP of rats in the CO2-enriched atmosphere appeared increased compared to those in a normal air composition. HS of rats resulted in an altered transcriptomics profile in the choroid plexus compared to animals maintained at normal posture. This was observed during both the HS period and during normal posture recovery period following 90 days of suspension. The greatest number of differentially expressed genes was observed at 90 days HS. Elevated CO2 also led to a different transcriptomics profile in the CP. The histology and ultrastructure results should be considered preliminary due to the limited number of samples. Examination of the CP by TEM showed blood vessel congestion and microvilli swelling in the CP, as well as some subpial and periventricular gliosis, but no associations were observed with treatment. There was no evidence of a reduced clearance of b-amyloid in the periventricular, perivascular and subpial regions of the brain in HS animals versus those in normal posture. Immunohistochemical staining of aquaporin 4, showed the localization to the subpial region and ependyma with increased immunoreactivity in the brains of CO2 exposed rats. This work was supported by awards NNX15AW48G to S.Z. Animal tissue and live data was provided under a tissue/data sharing agreement with Dr. Charles Fuller, UC Davis.

S B Zanello↗

Laser Truss Sensor for Segmented Telescope Phasing

A paper describes the laser truss sensor (LTS) for detecting piston motion between two adjacent telescope segment edges. LTS is formed by two point-to-point laser metrology gauges in a crossed geometry. A high-resolution (<30 nm) LTS can be implemented with existing laser metrology gauges. The distance change between the reference plane and the target plane is measured as a function of the phase change between the reference and target beams. To ease the bandwidth requirements for phase detection electronics (or phase meter), homodyne or heterodyne detection techniques have been used. The phase of the target beam also changes with the refractive index of air, which changes with the air pressure, temperature, and humidity. This error can be minimized by enclosing the metrology beams in baffles. For longer-term (weeks) tracking at the micron level accuracy, the same gauge can be operated in the absolute metrology mode with an accuracy of microns; to implement absolute metrology, two laser frequencies will be used on the same gauge. Absolute metrology using heterodyne laser gauges is a demonstrated technology. Complexity of laser source fiber distribution can be optimized using the range-gated metrology (RGM) approach.

Liu, Duncan T.↗

GLRS-R 2-colour retroreflector target design and predicted performance

This paper reports on the retroreflector ground-target design for the GLRS-R spaceborne dual-wavelength laser ranging system. The described passive design flows down from the requirements of high station autonomy, high global FOV (up to 60 degrees zenith angle), little or no multiple pulse returns, and adequate optical cross section for most ranging geometries. The proposed solution makes use of 5 hollow cube-corner retroreflectors of which one points to the zenith and the remaining four are inclined from the vertical at uniform azimuthal spacings. The need for fairly large (is approximately 10 cm) retroreflectors is expected (within turbulence limitations) to generate quite narrow diffraction lobes, thus placing non-trivial requirements on the vectorial accuracy of velocity aberration corrections. A good compromise solution is found by appropriately spoiling just one of the retroreflector dihedral angles from 90 degrees, thus generating two symmetrically oriented diffraction lobes in the return beam. The required spoil angles are found to have little dependence on ground target latitude. Various link budget analyses are presented, showing the influence of such factors as point-ahead optimization, turbulence, ranging angle, atmospheric visibility and ground target thermal deformations.

Lund, Glenn↗

Polarization effects on hard target calibration of lidar systems

The theory of hard target calibration of lidar backscatter data, including laboratory measurements of the pertinent target reflectance parameters, is extended to include the effects of polarization of the transmitted and received laser radiation. The bidirectional reflectance-distribution function model of reflectance is expanded to a 4 x 4 matrix allowing Mueller matrix and Stokes vector calculus to be employed. Target reflectance parameters for calibration of lidar backscatter data are derived for various lidar system polarization configurations from integrating sphere and monostatic reflectometer measurements. It is found that correct modeling of polarization effects is mandatory for accurate calibration of hard target reflectance parameters and, therefore, for accurate calibration of lidar backscatter data.

Kavaya, Michael J.↗

High pulse rate high resolution optical radar system

The system is composed of an optical cavity with a laser and a mode locking means to build up an optical pulse. An optical switch is also provided within the cavity to convert the polarization of the optical pulse generated within the cavity. The optical switch comprises an electro-optical crystal driven by a time delayed driver circuit which is triggered by a coincident signal made from an optical pulse signal and a gating pulse signal. The converted optical pulse strikes a polarization sensitive prism and is deflected out of the cavity toward the pending target in the form of a pulse containing most of the optical energy generated by the laser in the pulse build-up period. After striking the target, the reflected energy is picked up by a transceiver with the total travel time of the pulse being recorded.

Goss, W. C.↗

Low Power Consumption Lasers for Miniature Optical Spectrometers for Trace Gas Analysis

The air quality of any manned spacecraft needs to be continuously monitored in order to safeguard the health of the crew. Air quality monitoring grows in importance as mission duration increases. Due to the small size, low power draw, and performance reliability, semiconductor laser-based instruments are viable candidates for this purpose. Achieving a minimum instrument size requires lasers with emission wavelength coinciding with the absorption of the fundamental absorption lines of the target gases, which are mostly in the 3.0-5.0 micron wavelength range. In this paper we report on our progress developing high wall plug efficiency type-I quantum-well GaSb-based diode lasers operating at room temperatures in the spectral region near 3.0-3.5 micron and quantum cascade (QC) lasers in the 4.0-5.0 micron range. These lasers will enable the development of miniature, low-power laser spectrometers for environmental monitoring of the spacecraft.

Distributed Feedback (DFB) Diode Lasers↗

Low Power Consumption Laser for Next Generation Miniature Optical Spectrometers for Trace Gas Analysis

The air quality of any manned spacecraft needs to be continuously monitored in order to safeguard the health of the crew. Air quality monitoring grows in importance as mission duration increases. Due to the small size, low power draw, and performance reliability, semiconductor laser-based instruments are viable candidates for this purpose. Achieving a minimum instrument size requires lasers with emission wavelength coinciding with the absorption of the fundamental absorption lines of the target gases, which are mostly in the 3.0-5.0 mu m wavelength range. In this paper we report on our progress developing high wall plug efficiency type-I quantum-well GaSb-based diode lasers operating at room temperatures in the spectral region near 3.0-3.5 mu m and quantum cascade (QC) lasers in the 4.0-5.0 mu m range. These lasers will enable the development of miniature, low-power laser spectrometers for environmental monitoring of the spacecraft

distributed feedback laser (DFB↗

Differential absorption lidar measurements of atmospheric water vapor using a pseudonoise code modulated AlGaAs laser

Lidar measurements using pseudonoise code modulated AlGaAs lasers are reported. Horizontal path lidar measurements were made at night to terrestrial targets at ranges of 5 and 13 km with 35 mW of average power and integration times of one second. Cloud and aerosol lidar measurements were made to thin cirrus clouds at 13 km altitude with Rayleigh (molecular) backscatter evident up to 9 km. Average transmitter power was 35 mW and measurement integration time was 20 minutes. An AlGaAs laser was used to characterize spectral properties of water vapor absorption lines at 811.617, 816.024, and 815.769 nm in a multipass absorption cell using derivative spectroscopy techniques. Frequency locking of an AlGaAs laser to a water vapor absorption line was achieved with a laser center frequency stability measured to better than one-fifth of the water vapor Doppler linewidth over several minutes. Differential absorption lidar measurements of atmospheric water vapor were made in both integrated path and range-resolved modes using an externally modulated AlGaAs laser. Mean water vapor number density was estimated from both integrated path and range-resolved DIAL measurements and agreed with measured humidity values to within 6.5 percent and 20 percent, respectively. Error sources were identified and their effects on estimates of water vapor number density calculated.

Rall, Jonathan A. R.↗

Vibration-Induced Linewidth Broadening in Long Range FMCW Lidar

We analyze performance changes on a NASA-developed lidar system resulting from vibration loads expected during spacecraft landing. Vibration-induced laser linewidth broadening and reduced measurement precision are demonstrated and related to vibration level and target range.

Lidar↗

High repetition rate sealed CO2 TEA lasers using heterogeneous catalysts

The significant operational advantages offered by CO2 lasers, operating in the 10.6 micron region of the spectrum, over current solid state lasers, emitting in the near IR region, have prompted increased interest in the development of compact, reliable, rugged CO2 laser sources. Perhaps the most critical aspect associated with achieving a laser compatible with military use is the development of lasers which require no gas replenishment. Sealed, single shot, CO2 TEA lasers have been available for a number of years. Stark et al were first to demonstrate reliable sealed operation in single shot CO2 TEA lasers in 1975 using gas catalysis. GEC Avionics reported the compact, environmentally qualified, MKIII CO2 TEA laser with a pulse life of greater than 10 to the 6th power pulses in 1980. A sealed laser lifetime of greater than 10 to the 6th power pulses is acceptable for single shot cases, such as direct detection rangefinders for tank laser sights. However, in many other applications, such as tracking of fast moving targets, it is essential that a repetition rate of typically 30Hz to 100Hz is employed. In such cases, a pulse lifetime of 10 to the 6th power pulses is no longer sufficient and a minimum pulse lifetime 10 to the 7th power pulses is essential to ensure a useful service life. In 1983 Stark el al described a sealed, 100Hz CO2 TEA laser, with a life of greater than 2.6 x 10 to the 6th power, which employed heterogeneous catalysis. Following this pioneering work, GEC Avionics has been engaged in the development of sealed high repetition rate lasers with a pulse lifetime of 20 million pulses.

Price, H. T.↗

Laser ranging application to time transfer using geodetic satellite and to other Japanese space programs

Communications Research Laboratory (CRL) has been developing a laser time transfer system using a satellite laser ranging (SLR) system. We propose Japanese geodetic satellite 'AJISAI', launched in 1986 as a target satellite. The surface is covered not only with corner cube reflectors but also with mirrors. The mirrors are originally designed for observation of flushing solar light reflected by the separate mirrors while the satellite is spinning. In the experiment, synchronized laser pulses are transferred via specified mirror from one station to another while the satellite is up on the horizon to both stations. The system is based on the epoch timing ranging system with 40 ps ranging precision, connected together with UTC(CRL). Simulation study indicates that two stations at thousands of km distance from each other can be linked with signal strength of more than 10 photons and the distributed images of laser beam from AJISAI mirrors give many chances for two stations to link each other during a single AJISAI pass. Retro-reflector In Space for Advanced Earth Observation Satellite (ADEOS) and RendDezVous docking mission of Experimental Technology Satellite-7 (ETS-7) are briefly presented.

Kunimori, Hiroo↗

Arrival time of satellite-broadened laser pulses

A method for measuring the time of arrival of very narrow laser pulses which have been reflected and randomly broadened by a target is examined. It is known that these return pulses from the target have very small rise times. A threshold detection algorithm that detects the rising edge of the pulse is used for obtaining the pulse arrival times. The errors of the scheme are evaluated numerically for different pulse shapes, and a loose bound on the errors of detecting a typical pulse is obtained. A gamma-density model is used to characterize the random gain processes of the optical receiver, and the effect of such random gains on the errors of threshold detection is analyzed.

Iyer, R. S.↗

Ion beams from laser-generated plasmas

The paper describes the space-charge-limited beams produced by the plasma blowoffs generated by 20-MW bursts of 1.06-micron radiation from an active Q-switched Nd:YAG laser. Laser power densities near 10 to the 11th/sq cm on solid targets generate thermalized plasma plumes which drift to a 15-kV gridded extraction gap where the ions are extracted, accelerated, and electrostatically focused; the spatially defined ion beams are then magnetically analyzed to determine the charge state content in the beams formed from carbon, aluminum, copper, and lead targets. This technique preserves time-of-flight (TOF) information in the plasma drift region, which permits plasma ion temperatures and mass flow velocities to be determined from the Maxwellian ion curve TOF shapes for the individual charge species.

Hughes, R. H.↗

High sensitivity detection of trace gases at atmospheric pressure using tunable diode lasers

A detailed study of the detection of trace gases at atmospheric pressure using tunable diode lasers is described. The influence of multipass cells, retroreflectors and topographical targets is examined. The minimum detectable infrared absorption ranges from 0.1 percent for a pathlength of 1.2 km to 0.01 percent over short pathlengths. The factors which limit this sensitivity are discussed, and the techniques are illustrated by monitoring atmospehric CO2 and CH4.

Reid, J.↗

MLRS - A lunar/artificial satellite laser ranging facility at the McDonald Observatory

Experience from lunar and satellite laser ranging experiments carried out at McDonald Observatory has been used to design the McDonald Laser Ranging Station (MLRS). The MLRS is a dual-purpose installation designed to obtain observations from the LAGEOS satellite and lunar targets. The instruments used at the station include a telescope assembly 0.76 meters in diameter; a Q-switched doubled neodymium YAG laser with a pulse rate of three nanoseconds; and a GaAs photodetector with Fabry-Perot interferometric filter. A functional diagram of the system is provided. The operating parameters of the instruments are summarized in a table.

Shelus, P. J.↗