Search NASA⌕ Search

SEARCH · Search NASA

Results for “Long duration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

The 2024 July 16 solar event: a challenge to the coronal mass ejection origin of long-duration gamma-ray flares

We present a multi-spacecraft analysis of the 2024 July 16 long-duration gamma-ray flare (LDGRF) detected by the Large Area Telescope on the Fermi satellite. The measured > 100 MeV γ-ray emission persisted for over seven hours after the flare impulsive phase, and was characterized by photon energies exceeding 1 GeV and a remarkably hard parent-proton spectrum. In contrast, the phenomena related to the coronal mass ejection (CME)-driven shock linked to this eruption were modest, suggesting an inefficient proton acceleration unlikely to achieve energies well above the 300 MeV pion-production threshold to account for the observed γ-ray emission. Specifically, the CME was relatively slow (∼600 km/s) and the accompanying interplanetary type-II/III radio bursts were faint and short-lived, unlike those typically detected during large events. In particular, the type-II emission did not extend to kilohertz frequencies and disappeared ∼5.5 hours prior to the LDGRF end time. Furthermore, the associated solar energetic particle (SEP) event was very weak, short-duration, and limited to a few tens of MeV, even at magnetically well-connected spacecraft. These findings demonstrate that a very fast CME resulting in a high-energy SEP event is not a necessary condition for the occurrence of LDGRFs, challenging the idea that the high-energy γ-ray emission is produced by the back-precipitation of shock-accelerated ions into the solar surface. The alternative origin scenario based on local particle trapping and acceleration in large-scale coronal loops is instead favored by the observation of giant arch-like structures of hot plasma over the source region that persisted for the entire duration of this LDGRF.

Sun: UV radiation↗

Long-duration Energy Storage Technology Analysis and Development

This project develops a new low-cost and flexible long-duration energy storage (LDES) technology based on simultaneous regeneration technology. In lieu of the technology development, the project team also conducts a complete cost analysis for LDES based on various currently available technologies, as well as grid economic and environmental benefits analysis for LDES. There are three tasks in this project: Task 1. Fe-H2 flow cell fabrication, testing, demonstration; Task 2. Dynamic modeling, simulation and control architecture of power system; Task 3. Cost and grid analysis.

25 ENERGY STORAGE↗

The geometry of stellar occultation measurements on long-duration atmospheric monitoring missions

Geometrical considerations are presented for analyzing use of the stellar occultation technique on long-duration earth atmosphere monitoring missions. Simulated mission data are presented for three representative orbits. Bright near-IR stars are used as examples of how extensive global longitude-latitude coverage can be obtained by performing occultation measurements on several stars during the course of a 1-year mission. A brief comparison is made with similar missions using the sun as a light source.

Brooks, D. R.↗

The Long Duration Exposure Facility (LDEF) photographic survey special publication

During the construction, integration, launch, retrieval and deintegration of the Long Duration Exposure Facility (LDEF), photographic surveys were made. Approximately 10,000 photographs were taken during the various phases of the LDEF project. These surveys are of technical and scientific importance because they revealed the pre and post flight conditions of the experiment trays as well as the spacecraft. Visual inspection of the photographs reveal valuable data such as space environment's effects and the earth atmosphere's effects post-retrieval. Careful files and records have been kept of these photographs. Each photograph has a Kennedy Space Center photo number or a Johnson Spaceflight Center photo number as well as a Langley Research Center photo number. The tray number, row number, and experiment number are also noted. Out of the 10,000 photographs taken, approximately 700 selected photographs were chosen for publication in a NASA Special Publication (SP) because they reveal the effects of space exposure to the viewer. These photographs will give researchers and spacecraft designers visual images of the effects of the space environment on specific materials, systems and spacecraft in general. One can visually see the degradation of thermal blankets, meteoroid craters, outgassing discoloration, atomic oxygen erosion, etc.

Oneal, Robert L.↗

Leak Mitigation in Mechanically Pumped Fluid Loops for Long Duration Space Missions

Mechanically pumped fluid loops (MPFLs) are increasingly considered for spacecraft thermal control. A concern for long duration space missions is the leak of fluid leading to performance degradation or potential loop failure. An understanding of leak rate through analysis, as well as destructive and non-destructive testing, provides a verifiable means to quantify leak rates. The system can be appropriately designed to maintain safe operating pressures and temperatures throughout the mission. Two MPFLs on the Mars Science Laboratory Spacecraft, launched November 26, 2011, maintain the temperature of sensitive electronics and science instruments within a -40 deg C to 50 deg C range during launch, cruise, and Mars surface operations. With over 100 meters of complex tubing, fittings, joints, flex lines, and pumps, the system must maintain a minimum pressure through all phases of the mission to provide appropriate performance. This paper describes the process of design, qualification, test, verification, and validation of the components and assemblies employed to minimize risks associated with excessive fluid leaks from pumped fluid loop systems.

thermal controls↗

Capability Considerations for Enhancing Safety on Long Duration Crewed Missions: Insights from a Technical Interchange Meeting on Autonomous Crew Operations

As future flight crews on long duration deep space missions are expected to operate more autonomously, considerations must be given to onboard capabilities and human-computer teaming that will fortify the safety net traditionally provided by the Mission Control Center. In August 2018, the Human Factors and Behavioral Performance Element of NASA's Human Research Program convened a Technical Interchange Meeting (TIM) on Autonomous Crew Operations at NASA Ames Research Center to address how intelligent technologies can be utilized to augment crew capabilities to support real-time anomaly response. In this paper, we highlight three topic areas discussed at the TIM that have direct implications for future crew anomaly response capabilities: smart structures, cognitive assistants, and manpower.

autonomous crew operations↗

Quantification of Ophthalmic Changes After Long-Duration Spaceflight, and Subsequent Recovery

A subset of crewmembers are subjected to ophthalmic structure changes due to long-duration spaceflight (>6 months). Crewmembers who experience these changes are described as having Spaceflight Associated Neuro-Ocular Syndrome (SANS). Characteristics of SANS include optic disk edema, cotton wool spots, choroidal folds, refractive error, and posterior globe flattening. SANS remains a major obstacle to deep-space and planetary missions, requiring a better understanding of its etiology. Quantification of ocular, structural changes will improve our understanding of SANS pathophysiology. Methods were developed to quantify 3D optic nerve (ON) and ON sheath (ONS) geometries, ON tortuosity, and posterior globe deformation using MR imaging.

Sater, S. H.↗

The role of hydrogen as long-duration energy storage and as an international energy carrier for electricity sector decarbonization

With countries and economies around the globe increasingly relying on non-dispatchable variable renewable energy (VRE), the need for effective energy storage and international carriers of low-carbon energy has intensified. This study delves into hydrogen's prospective, multifaceted contribution to decarbonizing the electricity sector, with emphasis on its utilization as a scalable technology for long-duration energy storage and as an international energy carrier. Using Japan as a case study, based on its ambitious national hydrogen strategy and plans to import liquefied hydrogen as a low-carbon fuel source, we employ advanced models encompassing capacity expansion and hourly dispatch. We explore diverse policy scenarios to unravel the timing, quantity, and operational intricacies of hydrogen deployment within a power system. Our findings highlight the essential role of hydrogen in providing a reliable power supply by balancing mismatches in VRE generation and load over several weeks and months and reducing the costs of achieving a zero-emission power system. The study recommends prioritizing domestically produced hydrogen, leveraging renewables for cost reduction, and strategically employing imported hydrogen as a risk hedge against potential spikes in battery storage and renewable energy costs. Furthermore, the strategic incorporation of hydrogen mitigates system costs and enhances energy self-sufficiency, informing policy design and investment strategies aligned with the dynamic global energy landscape.

08 HYDROGEN↗

Solar+Storage for Household Back-up Power: Implications of building efficiency, load flexibility, and electrification for backup during long-duration power interruptions [Slides]

The study analyzes the evolving role of solar+storage for home backup power during long-duration power interruptions. In particular, it evaluates how required storage sizing is impacted as homes become more efficient, flexible, and electrified. The study relies on NREL’s ResStock building modeling platform to create statistically representative distributions of the existing building stock in ten locations across the United States. It then shows how the amount battery storage required for backup power rises or falls as a series of building envelope efficiency, load flexibility, and electrification measures are applied across the building stock in each region. The study also includes sensitivities to show how backup power requirements are impacted by the timing and duration of power interruptions, and explores variation in backup power requirements across the building stock within each study location. The results demonstrate the value of pairing solar+storage with efficiency upgrades, smart home controls, and (in mild winter climates) efficient heat pump retrofits. That value comes in the form of reducing the amount of storage required and/or extending the range of interruption conditions over which a given system can provide backup power (i.e., more extreme weather and/or longer interruptions). Heat pumps in cold-weather climates can pose a challenge for solar+storage backup power, given the amount of storage required, though are a vast improvement over electric-resistance heating. Retaining existing fossil-based heating systems for occasional use during power interruptions, as either the primary or supplementary source of heat, can mitigate this challenge. Other forms of building electrification (e.g., cooking and water heating) generally have marginal impacts on backup battery sizing, given their relatively small energy demand.

14 SOLAR ENERGY↗

Long-Duration High-Resolution Large-Eddy Simulations of Hurricane Laura (2020) for Infrastructure Design

This dataset provides long-duration large-eddy simulations (LES) of Hurricane Laura (2020), capturing the turbulent boundary-layer wind field during the storm's passage at horizontal grid spacings of 55.55 m and 10 m. Hurricane Laura made landfall as a Category 4 storm in southwestern Louisiana at 06:00 UTC on 27 August 2020, producing widespread damage to coastal infrastructure. The simulations characterize the spatial and temporal variability of the turbulent wind at heights spanning the lowest 300 m of the boundary layer, throughout the approach and passage of the storm's eyewall over a fixed location. To resolve the spatial heterogeneity of wind and turbulence conditions across the storm, seven independent refined LES runs are performed at radial locations spanning the storm relative to its direction of motion. The refinement positions are defined on a normalized radial coordinate r ̂=r/R, where R≈21 km is Laura's radius of maximum wind, and lie between r ̂=-1.5 and r ̂=+1.5 in ∆r ̂=0.5 increments along a line perpendicular to the storm's track at the midpoint of the simulation. Negative r ̂ corresponds to locations south-southwest of the storm center and positive r ̂ to locations north-northeast. The dataset is segmented into seven radial refinement groups.

17 WIND ENERGY↗

Experiment Definition Using the Space Laboratory, Long Duration Exposure Facility, and Space Transportation System Shuttle

Candidate experiments designed for the space shuttle transportation system and the long duration exposure facility are summarized. The data format covers: experiment title, Experimenter, technical abstract, benefits/justification, technical discussion of experiment approach and objectives, related work and experience, experiment facts space properties used, environmental constraints, shielding requirements, if any, physical description, and sketch of major elements. Information was also included on experiment hardware, research required to develop experiment, special requirements, cost estimate, safety considerations, and interactions with spacecraft and other experiments.

Sheppard, Albert P.↗

A search for solar neutrons on a long duration balloon flight

The EOSCOR 3 detector, designed to measure the flux of solar neutrons, was flown on a long duration RACOON balloon flight from Australia during Jan. through Feb, 1983. The Circum-global flight lasted 22 days. No major solar activity occurred during the flight and thus only an upper limit to the solar flare neutrons flux is given. The atmospheric neutron response is compared with that obtained on earlier flights from Palestine, Texas.

Koga, R.↗

Space Human Factors Engineering Challenges in Long Duration Space Flight

The focus of this panel is on identifying and discussing the critical human factors challenges facing long duration space flight. Living and working aboard the International Space Station (ISS) will build on the experience humans have had to date aboard the Shuttle and MIR. More extended missions, involving lunar and planetary missions to Mars are being planned. These missions will involve many human factors challenges regarding a number of issues on which more research is needed.

Garland, Daniel J.↗

Determining Simulation Fidelity Necessary for Evaluating Onboard Vehicle Capabilities and Crew Roles on Long Duration Exploration Missions Beyond Low-Earth Orbit

Identification of onboard vehicle capabilities and crew roles and responsibilities necessary for achieving effective human-systems collaboration will require iterative cycles of concept development and empirical evaluation of human performance in complex operations. This report presents the results of an effort to lay the groundwork for determining the level of fidelity of simulated environments most suitable for validating concepts and evaluating implementations of a new Human Systems Integration Architecture (HSIA) that will support the flight crew on long duration exploration missions beyond low-Earth orbit. To do that, we conducted a literature review on simulation fidelity and surveyed simulation capabilities inside and outside of NASA used in NASA-sponsored research. We also analyzed two International Space Station (ISS) vehicle anomalies to identify the types of scenario events and crew activities that may need to be simulated. Our survey findings reveal that most NASA simulation facilities are designed to achieve high physical fidelity while HSIA risk mitigation requires simulation emphasizing task and functional fidelity aspects. A trade analysis shows that, for standard and requirement development, evaluation conducted using synthetic task environments with inexperienced participants will support testing a wide variety of conditions and yield findings robust enough to be generalized to a wide variety of designs on which developed standards and requirements might be levied while allowing human performance standard measures to be collected using consistent methods across tasks and conditions. For technology/tool development, because findings will only need to be generalized to the actual target environment in which the technology/tool will be used, it is more suitable to evaluate the prototypes in a scaled world that preserves functional relationships present in the actual target environment with intended user populations. To wrap up, we give an overview of a well-known synthetical task environment in the space domain and discuss what it takes to construct a synthetic task environment.

simulation fidelity↗

Economically Viable Intermediate to Long Duration Hydrogen Energy Storage Solutions for Fossil Fueled Assets

This report was prepared as an account of work sponsored by the Office of Fossil Energy and Carbon Management of U.S. Department of Energy under Funding Opportunity Announcement Number DE-FOA-0002332 “Energy Storage for Fossil Power Generation”. The work aimed to explore and advance an innovative hydrogen energy storage system – the synergistically integrated hydrogen energy storage system (SIHES) – that has the following characteristics: • Compatible with existing or new coal and gas fuel electricity generation units, • best suited for intermediate to long duration energy storage, from 12 hours to weeks even months, and • capable of storing energy at the utility scale – hundreds of MWh to GWh energy storage with power output level in tens to hundreds of MW. Preliminary front-end engineering design (Pre-FEED) studies was carried out to develop and refine a site-specific SIHES as peaking power generation units (so named as HyPeaker) as the first market entry point, to demonstrate both the technical feasibility and the economic viability to integrate the HyPeaker “within the fence” of a fossil power plant. This specific site was TVA’s Johnsonville Combustion Turbine Plant. The HyPeaker was designed and engineered to integrate with a 60MW aeroderivative gas turbine unit already available at TVA’s Johnsonville site. This site-specific HyPeaker consists of an alkaline electrolyzer to produce hydrogen from CO 2 free electricity sources, an innovative low-cost high-pressure hydrogen storage system (Big-Ton) and the aero gas turbine to generate electricity using blend of hydrogen and natural gas. A holistic system level technoeconomic analysis tool specific to HyPeaker was developed to optimize the engineering design of the Johnsonville site-specific HyPeaker for cost and performance. The optimal design and specification of the Johnsonville site-specific HyPeaker are the following: • Alkaline electrolyzer: 3MW • Big-Ton storage vessel: 11,000kg H 2 at 3000psi. • 4-stage diaphragm hydrogen compressor: 55kg-H 2 /hr from 150psi to 3000psi. The HyPeaker is designed to provide sufficient hydrogen for 90% continuous operation of the HyPeaker. All major components have design life of 30 years. The capex of HyPeaker is estimated at $\$$7.1M. This included $\$$1.5M for the electrolyzer, $\$$5.6M for the storage vessel and compressor. The cost of aero gas turbine was included as it is already available at the site. Key findings are: • HyPeaker can be designed, manufactured, installed and integrated with the fossil power plants, with sub-systems and components commercially available on the market today, even when it is scaled up to an order of magnitude larger than the one at the Johnsonville site. HyPeaker is a technologically viable solution to cover a wide range of energy storage duration needs, from daily peaking operation to seasonal shifting for fossil fueled assets. • The cost advantage of SCCV based Big-Ton H 2 storage vessel made it possible to “oversize” the H 2 storage subsystem to achieve overall system level cost optimization. The benefits are two-fold. First, it allows to significantly reduce the capacity and cost of electrolyzer by spreading H 2 production over a much longer period of time when the fuel cost for electricity production is low. Second, it allows to balance the hydrogen production and usage shift over weeks to months to meet the peak demands. As such, the capital cost of HyPeaker system using the Big-Ton was less than half of the cost of a system with today’s steel tube based H 2 storage system. The HyPeaker has even better cost advantage Li-ion battery based energy storage system. The estimated capital cost of Li-Ion battery system would be at $\$$38M, under the same projected 20-year electricity generation profile of the Johnsonville site. This is over 5 times more expensive than the HyPeaker system. • Since industry scale energy storage systems do not have 100% energy conversion and storage efficiency, energy storage systems using fossil fuel generated electricity would increase the CO 2 emission. This is particularly the case for HyPeaker due to its low round trip efficiency. Therefore, a more sensible solution would be to the excessive or curtailed electricity from CO 2 emission free sources such as solar farms, wind farms or nuclear power plants, to produce hydrogen, and integrate them with the HyPeaker. Electricity from TVA’s nuclear power plants was used for the Johnsonville HyPeaker. • The economic viability of HyPeaker is expected to be further improved when global supply chains are taken into consideration. For the same Johnsonville site specific HyPeaker, the capex would be reduced to ~$\$$3.6M from ~$\$$7.1M, and the added LCOE is reduced to ~$\$$85/MWh. With the bipartisan Infrastructure Investment and Jobs Act, the cost of domestically produced HyPeaker sub-systems would be at the level of today’s global suppliers. Since the peaking units generally operate at peak usage period, thereby demanding higher price, the projected $\$$85/MWh LCOE would be within the realm of financial viability for utility operators.

08 HYDROGEN↗