Search NASA⌕ Search

SEARCH · Search NASA

Results for “Long duration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Interpretation of Hydraulic Fractures Based on Microseismic Response in the Marcellus Shale, Monongalia County, West Virginia, USA: Implications for Shale Gas Production

Summary Hydraulic fracturing is critical for extracting shale gas in the subsurface. The treatment technique of multistage hydraulic fracturing is widely used to maximize production. In multistage hydraulic fracturing, not all pumping stages make the same contribution for production, although the designed stimulation process is almost same in every pumping stage. In this study, we characterize the microseismic responses of hydraulic fracturing. Significant variations of microseismic characteristics are observed among the different pumping stages. Pre-existing natural fractures are examined along the horizontal well in selected stages. Combined with the Mohr’s circle analysis, results of the fracture study show that induced hydraulic fractures can be captured by pre-existing natural fractures. Induced hydraulic fractures are simulated by the unconventional fracture model (UFM), and the result reveals that the stress-shadow effect diverts the direction of hydraulic fractures. The diverted hydraulic fracture affects the development of the hydraulic fracture network, which has influence on production. The treatment of two-step pumping is investigated by application of hydraulic diffusivity. Hydraulic fracturing performance and production could be optimized by the treatment of two-step pumping in a single stage. The second pumping creates new fractures and fills the fractures with additional proppants to maintain production for a long duration.

Energy & Fuels↗

Regenerative Fuel Cell System (Cooperative Research and Development Final Report, CRADA Number CRD-16-635)

Grid energy storage is required to maintain reliable electricity delivery from energy producers to their customers. As electrical loads on the grid change throughout the day, stored energy supplies electricity during increased power demand periods. Further, as more renewable and alternative energy sources are added, energy storage will maximize the usefulness of these technologies. Currently, the United States has over 24.6 GW of grid storage, about 2% of the total electrical production capacity. About 95% of energy storage comes from pumped hydro. However, pumped hydro energy storage is dependent on existing geographic features, making it difficult to integrate with widespread renewable energy sources. As energy demands continue to expand, and more renewable energy (i.e. wind and solar) is added to the grid, new energy storage technologies will be needed that are not dependent on geographic features. Battery technologies can provide energy storage for some applications, but are not economically well-suited for long duration charge/discharges, such as load-leveling of renewable energy. Consequently, development of new energy storage devices will augment the existing grid and reduce the capital investment in construction upgrades. As ever-increasing mandates for renewable energy are implemented, lower-cost energy storage solutions for renewable energy will be necessary to keep electricity costs low for consumers.

13 HYDRO ENERGY↗

Collaboration to Enable Higher Penetrations of Solar Power Generation Using the Natural Gas Pipeline System for Energy Storage (CRADA CRD-14-00567)

This unique project explored one possible solution for photovoltaic (PV) generation to become a reliable and dispatchable energy resource similar to conventional baseload fossil fuel electricity generation. Solar power generation is a renewable resource that varies naturally from day-to-day as well as seasonally. To use solar power as a baseload generation asset requires a flexible storage system that can recover power on both a daily and seasonal basis. Converting solar power to natural gas (i.e., first to hydrogen and then to methane) and having access to utility-scale storage in the natural gas network has the potential to make solar power generation a baseload asset. This will: 1) Increase the net energy yield from solar resources by increasing the effective capacity factor and maximize the energy produced during the assets’ lifetimes. 2) Improve the economics of energy storage for solar project developers, thereby accelerating the deployment of new solar generation. 3) Reduce the impact of increasing solar penetration on congestion of the electrical transmission system by shifting power delivery in time using the gas pipeline network for long-duration storage. 4) Reduce the impact of increasing solar generation on electrical distribution system control. 5) Offer alternative revenue sources for solar power generation beyond electricity including: hydrogen (H 2 ) production for stationary fuel cells and fuel cell electric vehicles, conversion of carbon dioxide (CO 2 ) to methane (CH 4 ) as a direct drop-in replacement for fossil natural gas use, and transmission as high volumetrically-dense CH 4 for use in transportation, heating, power generation, chemical production or conversion back to H2 at the point of use. Additional work was added to this CRADA in modification 4 having a primary objective to characterize the performance of the electrolyzer, Southern California Gas (SoCalGas) bioreactor and balance of plant to demonstrate production of renewable natural gas (RNG) from renewable H 2 and CO 2 using single-cell, self-replicating organisms. The additional scope of work allowed researchers to ramp up gas flowrates and pressure of the system over the designed range to grow the cells and begin to show the load-following capabilities of this anaerobic gas fermentation process. These activities enabled the research team to predict system performance at much greater scales; namely 10’s of mega-watts (MWs) of electrolyzer nameplate capacity.

14 SOLAR ENERGY↗

Development of Energy Storage: Cost models

Energy storage technologies offer a promising solution to electric grid stability issues associated with the integration of variable renewable generators. The capability to match the electrical power output to instantaneous fluctuations in grid demand is crucial to ensure continuity of service. Including energy storage capability in an integrated energy system (IES) can provide the flexibility needed to meet variable electric demand and reduce the load following demands place on the reactor. In this report, economic data collected for energy storage (ES) technologies are described to support the objective of assessing the profitability of ES integration within the IES framework. In particular, there is a growing interest in thermal energy storage (TES) given its unique capability for long-duration storage for improving electricity reliability at a low levelized cost. It is common practice to evaluate the total lifetime cost and profitability before commercializing new technologies. In this report we identify and examine the models needed to better understand the economics of thermal energy storage. We extend the TES cost model in RAVEN in the context of a balance of plant (BOP) that incorporates thermal storage. To focus the discussion, following a general overview of the most promising TES technologies, we consider a use case that involves a sensible heat, two-tank, molten-salt system. Structural and operational details are reported to identify the source of construction capital expenditure and operation and maintenance cost. A detailed description of the different cost items is provided as well as the cost scaling with different storage capacity and power ratings for capacity optimization purpose. In addition, the capital expenditure and the recurring cost of representative two-tank, molten salt coupled with concentrated solar plants are provided for readers’ reference. The ES use case is noteworthy as it is in the pilot stage of commercialization. We identify those areas that would benefit from an increased economic focus to obtain a more complete compilation of cost data. We also describe the thermal coupling issues that arise from integration of the two-tank molten salt thermal energy storage system with a BOP, which is the subject of our current research. Some components of costs will need to be evaluated through dedicated technoeconomic analysis in future modeling activities using modeling procedures proposed in this report. With the data presented and the procedures described in this report, sufficiently accurate models can be implemented for the solution of both the power dispatch and the capacity expansion problems within the RAVEN-based HYBRID framework.

25 ENERGY STORAGE↗

Immobilization of Uranium in a Wetland 8-km Downstream from an Industrial Source (Report)

A three-day walk-over survey with portable gamma detecting equipment was conducted over a uranium-contaminated wetland located 8-km downstream from a former fuel fabrication facility. 97,000 spectra were collected, individually processed to extract uranium activity data, and then integrated with topographical information (LIDAR) to create maps. These maps reveal that 50 years after being released into the environment, 11% of the uranium is retained in the 9-ha wetland area. Combined with measurement collected closer to the source, it was determined that 94% of the released uranium is presently being held in downstream wetlands. This demonstrates that wetlands can be very effective at immobilizing contaminants for long durations. The survey also showed that previous flyover maps overestimated the size of the contaminated areas by 140% but had the advantage of being completed in orders-of-magnitude fewer labor hours. Depending on project needs, the walk-over technique may be useful to include in tandem with flyover measurements to acquire maps with greater sensitivity and spatial resolution.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solar Steam on Demand

INTRODUCTION: This Report summarizes the research and development project performed by Sunvapor and the subrecipient National Renewable Energy Laboratory (NREL) during the period of 10/01/2018-9/30/2021. The work was aimed at the economic integration of solar steam with an industrial process, and in particular, the advantages that a novel type of thermal energy storage and collector design could bring to the system. The completed work includes experimental research on the storage material, design of the collector, engineering of a complete solar steam plant, and economic analysis. The plant was, in the end, not constructed, due to COVID-19 impacts to the project host. PURPOSE: The purpose of the project was to test the hypothesis that a levelized cost of heat (LCOH) of 2¢/kWh delivered to a steam-consuming process, including energy discharged from storage, could be feasibly achieved. PROJECT OBJECTIVES: For Budget Period 1 our objectives were to engineer a prototype industrial solar steam generation system, and design and test a Latent Heat Energy Storage (LHES) lab-scale system. For Budget Period 2 our objectives were to construct and test the solar steam prototype plant, and to build and factory-test a full LHES module. For Budget Period 3 our objective was to integrate the storage module with the solar steam generator, show successful long duration energy tests of the combined system, and use the results to project the LCOH of delivered steam to a second-generation plant. PROJECT OUTCOMES: Various phase change materials (PCMs) for the LHES were tested for compatibility with industrial steam uses as measured by phase change temperature, stability of latent heat of fusion, and their corrosive effects on steel (the heat exchanger material). Two of these materials (sodium formate and sodium/ potassium) showed potential to meet the technical criteria. The estimated cost of a complete LHES module with these materials did not meet economic targets. The developmental collector design builds from previous work to exploit the potential cost advantages of a spaceframe of lumber construction. Design improvements were achieved in assembly efficiency and structural performance. A complete engineering package was completed for the solar steam system without storage that included the developmental as well as commercial arrays. The plant was permitted for construction. The storage CAPEX for a reference plant was estimate to be greater than $\$ 57$/kWh. The LCOH of the system without storage and with developmental collectors of lumber construction was projected to be 2¢/kWh, assuming a FCR of 8.2% over thirty years. PROJECT MILESTONES: The Milestones fully achieved in the first Budget Period includes obtaining a Letter of Intent from an industrial steam-consuming project host, issuance of a construction permit, and corrosion resistance. The Milestone that was partly achieved was the degradation in the latent heat of fusion. Milestones associated with Budget Periods 2 and 3, related to the construction and operation of the plant were not achieved as a result of the host shutting down the plant due to COVID-19 impacts. CONCLUSIONS: Sunvapor was able to secure an agreement with a host to build a fully engineered and permitted solar steam plant that met the host’s economic goals. As a basis for comparison, the solar field design was comprised of eight commercial collector arrays and one developmental Green Parabolic Trough Collector (GPTC) array. The projected LCOH with a solar field entirely populated with a second generation GPTC met the goal of 2¢/kWh. The experimental program concerning the PCM indicated the feasibility of meeting their technical requirements for industrial steam uses. The cost of the complete LHES exceeded its $\$ 14$/kWh target, and therefore the inclusion of LHES could not be economically justified. Due to COVID-19 impacts on the host, the solar steam plant was not constructed.

14 SOLAR ENERGY↗

Illinois Compressed Air Energy Storage

Compressed Air Storage Energy (CAES) is one of the few mid- technology readiness level (TRL) energy storage technologies that can address the long-duration infrastructure needed for dealing with variable electric output from renewable energy sources and be reliable backup source for replacing natural gas during supply interruptions. In CAES the goal is to capture and store compressed air in subsurface sedimentary strata when off-peak power is available, or there is a need for grid balancing. The stored high-pressure air is returned to the surface and used to power turbines during reductions in either renewable energy or supply issues with fossil fuels. The Illinois CAES project evaluates the feasibility of capturing surplus electrical energy from renewable sources and off-peak energy at a fossil fuel power plant at the University of Illinois Urbana - Champaign (UIUC) campus. The UIUC Abbott Power Plant uses natural gas and coal to generate electricity (capacity: 35 MWe by coal and 49 MWe by NG). UIUC receives additional electricity from on campus solar farm, and off-campus wind farm. Also, UIUC offsets electricity usage by integrating geothermal energy systems into building heating Also, UIUC offsets steam, hot and chilled water usage by integrating geothermal energy systems into building heating and cooling systems. Furthermore, the two UIUC solar farms (Solar Farm 1 is 21 acres and Solar Farm 2 is 54 acres) to generate 4.68 megawatts (MW) and 12.1 MW, respectively. Campus receives 8.6% of the wind-generated electricity from the Rail Splitter Wind Farm. The project objectives were to design an integrated system to 1) capture surplus electrical energy from renewable sources and the Abbott Power Plant using a CAES system, 2) store both the compressed air and the thermal heat generated by compression in the subsurface as part of an adiabatic system, 3) simulate the movement of the air and heat in the subsurface, 4) recover the compressed air and stored thermal heat to rotate turbine generators during sustained interruption due to weather events or fossil fuel disruptions.

03 NATURAL GAS↗

Atmospheric Cold Plasma Jet Coating and Surface Treatment for Improved Adhesive Bonding Performance of Dissimilar Material Joints Subject to Harsh Environmental Exposure

The program goal was the development and demonstration of a novel material coating system using an innovative atmospheric cold microwave plasma jet to enable surface functionalization for corrosion protection, wear resistance and improved bonding strength. The technical approach was directed towards proof-of-concept demonstration of advanced point-of-manufacturing material bonding to improve adhesive joint performance subject to harsh environmental exposure. The assembled team, consisting of the researchers at the University of Illinois, end-users at General Motors and small business manufacturer Starfire Industries, successfully demonstrated a single, cost-effective, high-volume production process that meets the requirements of multi-material combinations relevant to the energy-intensive transportation industry (e.g. Al-steel, Mg-steel, Al-Mg and Al-CFRP joints for body-in-white structures) while eliminating offline pretreatment for Al and Mg alloy substrates that are energy intensive, have chemical waste disposal issues, and add cost. Technical demonstration of dissimilar material joining while maintaining bonding strength and cohesion after long-duration environmental exposure was accomplished for all materials of interest. This novel approach has broad applicability for manufacturing in automotive, aerospace, marine, railcar, and specialty consumer goods, etc.

36 MATERIALS SCIENCE↗

Valuation of Hydrogen Technology on the Electric Grid Using Production Cost Modeling: Cooperative Research and Development Final Report, CRADA Number CRD-18-00736

This research project will estimate the value to the United States electric grid of deploying hydrogen technology (such as electrolyzers and hydrogen-fueled generation) under projected conditions of high renewable penetration. The analysis will advance the state of the art in systems-level cost-benefit analysis of hydrogen technology for the electric grid by incorporating production cost modeling results in the analysis. Large-scale grid simulation tools will be used to evaluate total system production cost and grid operation when hydrogen technology is deployed for applications such as energy storage and demand response. Scenarios will include one or more future grid mixes in the Western Interconnect (WI) with a high proportion of intermittent renewables. Electric Power Research Institute (EPRI) will work with four utility companies to refine scenarios. Results of the analysis will include comparing the net cost of hydrogen to other technologies for long duration storage, and of power-to-gas (P2G) scenarios including merchant hydrogen sale and hydrogen-fueled generation.

08 HYDROGEN↗

Clean Condensing Gas Furnace

Natural gas furnaces are the most common space heating equipment in the U.S. residential and commercial building markets. However, current residential natural gas condensing furnaces generate substantial acidic condensate as well as significant emissions of sulfur oxides (SOx), nitrogen oxides (NOx), carbon monoxide (CO), hydrocarbons (HC), and methane (CH 4 ) contributing to environmental degradation of air, water, and soil. This report describes a novel solution to reduce the environmental impact of natural gas condensing furnaces based on the technology of a monolithic acidic gas reduction (AGR) catalyst for SOx trapping, NOx redox to nitrogen, and oxidation of formic acid, CO, HC, and CH 4 . The AGR technology offers the following benefits: (1) a neutral furnace condensate with a pH of ~7, allowing its safe release into the sewer system thus eliminating a second drainage system; (2) trapping and removing nearly all SOx emissions; (3) NOx emissions nearly at nearly 1-2 ng/J, more than 95% lower than new emissions standards in California; (4) the use of a low-cost heat exchanger as a condensing heat exchanger (HX) since the condensate is not acidic, avoiding the need for expensive stainless steel alloys; and (5) unburnt fuel energy recovery to boost efficiency.The AGR component and AGR-enabled furnace performance were broadly tested to determine their effects on long-term reliability and durability, as well as SOx storage and regeneration activity. The AGR regeneration does not impair the performance in achieving neutral condensate and ultra-low NOx emissions, and the AGR catalyst subjected to regeneration activities continued to function well and achieved slightly better annual fuel utilization efficiency (AFUE). The 400-hour reliability and durability test of the retrofitted condensing furnace with the AGR component shows that the furnace unit still achieves a neutral furnace condensate with a pH of ~7 and enables 0~3 ng/J of NOx emissions. However, the 400-hour operation slightly degraded the AFUE because of soot particle accumulation caused by frequent incomplete combustion owing to inappropriate condensate drainage during testing. Thus, proper condensate drainage is critical for AGR-enabled furnaces. Furthermore, neutron computed tomography was employed to survey the aged AGR component and demonstrate high-resolution 2D and 3D representations for the nondestructive diagnosis of the AGR component. The tomography showed that the AGR component did not deform or suffer broken AGR channels. A new AGR catalyst with low precious metal loading was preliminarily explored to identify a pathway of optimizing AGR material loading and maximizing acidic gas reduction at low cost. The new AGR component can reduce precious metal loading by 38% and still achieve neutral condensate and ultralow NOx emissions. The furnace with the AGR component of low Pt/Rh loading enables a maximum AFUE of 97%, which is meaningfully higher than the original furnace. Long-duration testing for the furnace enabled with the low precious metal loading AGR component will be vital in future research. Although the current work demonstrates a proof of concept for the AGR-enabled furnace, the AGR assembly needs to be optimized and integrated into the design of new OEM furnace products. Furthermore, the AGR technology can be applied not only for residential gas furnaces, but also for commercial rooftop units, gas heat pumps, gas-fired water heaters, combustion boilers, and other systems.

03 NATURAL GAS↗

Advanced Hydropower and PSH Capacity Expansion Modeling (Final Report on HydroWIRES D1 Improvements to Capacity Expansion Modeling)

Hydropower and pumped-storage hydropower (PSH) have played a key role in providing flexible, low-carbon electricity to the U.S. electricity system for over a century. As variable generation (VG) deployment increases the demand for flexible, dispatchable generation, it is important to use all available methods for understanding how hydropower and PSH interfaces with VG in a future low-carbon grid. Capacity expansion models (CEMs) of electricity systems are often used to study future electricity scenarios, but these tools often have difficulty representing site- and technology-details of hydropower and PSH due to limited spatial, temporal, or process resolution. This report demonstrates a set of model advancements to improve hydropower and PSH representations in CEMs and other models that consider hydropower and PSH's role in electricity systems. Model advancements include new data integration to define closed-loop PSH resource availability and cost, along with site-level parameterizations of existing PSH capacity and energy storage specifications. Shifting energy across seasons for both hydropower and PSH is explored to demonstrate the potential value of long-duration storage. New representations of hydropower upgrades offer opportunities to increase dispatchability, add pumps, or independently add capacity or energy depending on what is most valuable. New model structures and data are demonstrated individually and in combination to observe their impact on model results and provide initial insights into what is most important for analysts, electricity system planners, and hydropower decision-makers to consider when assessing future roles of hydropower. Improving flexibility of existing hydropower assets has the potential to reduce CO 2 emissions through complementing VG technologies and/or improve electricity system economics by reducing the need to deploy higher-cost systems. Large-scale energy storage is also shown to provide opportunities for balancing seasonal differences in VG, particularly solar photovoltaics (PV). Initial analysis with a new closed-loop PSH resource and cost dataset also demonstrate the potential for new PSH deployment to offer new grid flexibility opportunities. Future analysis and modeling of hydropower's role in the U.S. and other electricity systems could include methodological improvements based on those discussed here along with sensitivity analysis to better represent current and future potential hydropower and PSH flexibility. Improvements to geospatial and site-level data can further improve the understanding of how hydropower and PSH can be upgraded and operated in response to future electricity system needs. This work lays the groundwork to use advanced planning models to explore the range of roles hydropower and PSH can play in the grid of the future.

13 HYDRO ENERGY↗

Net-zero Microgrid Program Report: Microrred de la Montaña Feasibility Study (Executive Summary Extended)

This feasibility study provides the technical and economic rationale for the Microrred de la Montaña as a viable solution for supplying reliable and resilient electricity to an underserved region in Puerto Rico – a region that is the first to be disconnected from the grid and the last to be restored, enduring months long outages. It begins the process of the development of the microgrid through conceptual design, engineering, detailed electrical design, implementation, and operation. The Microrred de la Montaña is organized under the governance of the Cooperativa Hidroeléctrica de la Montaña (Cooperativa) which has legal status as a cooperative and power provider under the laws of Puerto Rico. The members are the municipalities of Adjuntas, Jayuya, Lares and Utuado with a combined population of 90,000. These municipalities are in central Puerto Rico – a mountainous region that is extremely vulnerable to weather events and excessive, long-duration power outages and are among the poorest and most disadvantaged regions in Puerto Rico. Funding from external sources is necessary to acquire the resources for a resilient power delivery system. Regulatory support is necessary to establish operational relationships with the incumbent power providers. The Microrred de la Montaña is envisioned as a resilient microgrid that manages distributed energy resources – local solar, storage, and hydroelectricity over an upgraded distribution network within the boundaries of four municipalities. This feasibility study provides the results of an extensive techno-economic analysis to form a sound basis for decision-making by community leaders, their constituents, funding and investment agencies, and regulators to realize the benefits that are achievable by fully implementing the design and planning recommended for the Microrred de la Montaña.

13 HYDRO ENERGY↗

Powertrain Performance and Total Cost of Ownership Analysis for Class 8 Yard Tractors and Refuse Trucks

Advanced powertrain technologies, specifically fuel cell electric powertrains, have gained attention as viable alternatives for medium- and heavy-duty (M/HD) vehicles. However, it is unclear how these alternative powertrain vehicles stack up against their diesel counterparts in terms of performance and total cost of ownership (TCO). Furthermore, there are vehicle segments within the M/HD sector that have remained unstudied for fuel cell electric applications. This analysis aims to provide a comparative scoping-level TCO and performance analysis for two heavy-duty vocation vehicles (Class 8 U.S. port-side yard tractor and Class 8 U.S.-based refuse truck) for both conventional diesel and heavy-duty fuel cell electric (HDFC) powertrains. The refuse truck analysis also considered compressed natural gas powertrains (CNG) for comparison. The analysis includes seven timeframes (2020, 2025, 2030, 2035, 2040, 2045, and 2050) for comparison. This simplified TCO analysis includes only direct costs (fuel price, glider purchase price, and operating & maintenance costs) and excludes any associated indirect cost (e.g., dwell time costs and other opportunity based costs). Representative drive cycles for each vehicle were based on on-board GPS logged data and chosen by the analysis team to represent average, non-extreme driving conditions. At the time the analysis was performed, the Inflation Reduction Act was not in effect and therefore any potential subsidies and future cost reductions enacted under the Inflation Reduction Act were not included. Based on the operational setpoints used in this analysis, HDFC powertrains for both yard tractors and refuse trucks have the potential to achieve TCO advantages over conventional diesel powertrains (and CNG for refuse truck applications) in the near- to mid-term future while meeting the necessary duty cycle performance requirements. Yard tractors and refuse trucks spend a significant amount of time operating at low speeds, with long durations of idling, and experience numerous start/stop occurrences. These operational characteristics favor fuel cell performance as fuel cells operate with higher efficiencies at lower percentages of total power output. Conversely, conventional diesel and CNG engines are most efficient at higher percentages of total power output. This helps HDFC powered yard tractors and refuse trucks realize improved fuel economy when compared to their diesel counterparts, which helps reduce total fuel costs and therefore, total TCO. The analysis demonstrates that fuel prices play a significant role in determining TCO for each vehicle and should remain an R&D focus area. Overall, under the analysis' specified conditions, HDFC yard tractors have the potential to achieve cost parity with diesel yard tractors as early as 2025. For refuse trucks, HDFC refuse trucks have the potential to achieve cost parity with diesel and CNG refuse trucks in 2030 and 2040, respectively.

33 ADVANCED PROPULSION SYSTEMS↗

Damage Accumulations Predictions for Boiler Components Via Microstructurally Informed Material Models

The goal of the project was to model material behavior and degradation during cyclic plasticity— with and without hold time—for nickel-based superalloys used in USC (ultra-super-critical) and A-USC (advanced-ultra-super-critical) boiler components. The study provided physically informed models, capturing the microstructural changes taking place in the industrial components under cyclic loading and long duration stress (up to 300,000 hours) and high temperature exposure (1100°F/593°C to 1400°F/760°C). The major developments were: 1) Qualitative and quantitative understanding of microstructure evolution (gamma prime precipitates), deformation (dislocation density), and damage mechanisms of Haynes ® 282 alloy. 2) Qualitative understanding of microstructural features generating local strain variations. 3) A continuum damage mechanics model (CDM) for Haynes ® 282 alloy at 1100°F to 1400°F capturing cyclic behavior with and without hold time. 4) Structural analysis for creep and LCF life predictions of an USC thick-wall Grade 91 superheater steel header and understanding life sensitivity to wall thickness of an AUSC Haynes ® 282 header.

20 FOSSIL-FUELED POWER PLANTS↗

PUR-1 Water Processing and Cooling System Upgrade

The project objective was to purchase equipment related to the safety and operational capability of PUR-1. Following a 10x power uprate and the return to an active operational cycle, a water process system replacement is required to maintain the bulk coolant temperature within the bounds of the Technical Specification limit at the PUR-1. The replacement project will ensure safety and availability of the PUR-1 for long duration operational cycles and applicability to the largest possible customer base. The equipment to be purchased for this work includes a new main coolant pump rated to at least 30 gallons per minute, a heat exchanger to remove heat from the primary coolant, and a chiller system to release the heat to the environment via city water. The proposed system exactly replicates the installed system with a slight increase in capacity.

42 ENGINEERING↗

Distributed Energy Resource (DER) Reliability for Backup Electric Power Systems

Hospitals, emergency services, military bases, ports, airports, industries, commercial facilities, and others rely on backup power systems to provide electricity for their critical loads during grid outages. The purpose of this report it to provide accurate reliability information on commonly deployed distributed energy resources (DERs) to improve quantitative estimates for the reliability of these backup power systems during a grid outage. A backup power system consists of DERs, an electric distribution system with its associated switches and other devices, and mechanisms to control and manage the flow of electricity. Too often, facilities and campuses fail to properly quantify the reliability of their backup power systems. DERs are assumed to be 100% reliable, with the only concern being the availability of fuel. Such assumptions can lead to gross errors in the backup system's reliability estimates, particularly for long-duration outages. This report provides a set of estimates for reliability of emergency diesel generators (EDGs), natural gas prime generators and combined heat and power (CHP) prime movers, solar photovoltaics (PV), wind turbines, and Li-ion battery energy storage systems (BESS). The estimates are derived from empirical data when available and supplemented by modeling results when needed. These reliability estimates are for the DERs ability to provide power during a grid outage, ranging from an hour to 2 weeks.

14 SOLAR ENERGY↗

Liquid Air Combined Cycle TM for Power and Storage

Liquid Air Combined Cycle (LACC) is a hybrid liquid air energy storage (LAES) system combining energy storage with a combustion turbine to enable large-scale, long-duration energy storage (LDES) while reducing fuel intensity compared to the current state-of-the-art. The LACC technical approach employs proven equipment (cryogenic refrigeration, storage, tanks, pumps, gas turbines, exhaust heat recovery equipment, and turbines) to limit technical risk to a novel organic Rankine cycle (ORC), which was evaluated during this project and found to be feasible. Moreover, LACC storage is safe and relatively compact, to facilitate siting close to loads and within metropolitan regions. The air storage medium is freely available and eliminates supply chain constraints. LACC uses cryogenic air as a storage medium and a gas turbine as the source of heat to drive the discharge process. LACC is distinguished from other LAES technologies by several factors. The charge and discharge processes are decoupled so that cryogenic liquid air is the only storage medium. Other systems also store the higher temperature thermal energy from the liquefaction process in an additional medium. Subsequently, LACC focuses on maximization of the discharge energy and power. LACC also permits the use of commercially available cryogenic refrigeration and storage technologies to increase competition. This project identified product requirements to support market entry and commercialization of the LACC in modular units of approximately 117 MW, each drawing liquid air from customary cryogenic storage tanks capable of storing 75 GWh of dispatchable energy, more than pumped storage hydro or compressed air energy storage technologies. An economic analysis identified the specific liquid air consumption (quantity of liquid air per unit of discharge energy) as a critical parameter. Minimizing the air consumption reduces the specific capital cost ($\$ $/kW) for charging and discharging equipment by reducing the size of piping and turbomachinery. Likewise, the specific cost of energy capacity ($\$ $/kWh) is reduced by increasing the energy deliverable from a given size tank. The cycle was analyzed to identify the optimal equipment selection and operating conditions, which in turn were combined with quotes and cost estimates to calculate the cost of energy from an LACC system. A substantial effort was focused on the ORC, which draws low-temperature heat from the gas turbine exhaust and condenses at low temperature using the cryogenic liquid air as a heat sink. Alternative turbomachinery arrangements were evaluated for feasibility and cost. A technology maturation plan lays out a low-risk approach to development of the novel ORC components and demonstration of LACC technology at pilot scale.

25 ENERGY STORAGE↗

Guidelines for Determining the Load Resistance of Thin-Glass Triple-Pane Insulating Glass Unit Configurations

This guideline is intended to provide information relevant to the specification of triple- pane insulating glass (IG) units where the thickness of lite number 2 (center lite) is less than or equal to the thickness of lite numbers 1 and 3. Procedures and charts are presented to determine the load resistance (LR) of common soda-lime glass thicknesses from 0.7 mm (3/128 in.) to 1.8 mm (9/128 in.) exposed to a uniform lateral load of short or long duration, for a 0.008 probability of breakage. Deflection under load, horizontal self-weight deflection, and natural frequency procedures and charts are also included to aide in the selection of glass thickness to meet manufacturing and/or loading criteria determined by the user.

42 ENGINEERING↗