Search NASA⌕ Search

SEARCH · Search NASA

Results for “Low temperature plasma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Implementation of a portable diagnostic system for Thomson scattering measurements on an electrothermal arc source

To fulfill the increasing needs of diagnostic support for researchers in plasma technology, a portable diagnostic package (PDP) equipped for both laser Thomson scattering (TS) and optical emission spectroscopy has been designed and constructed at Oak Ridge National Laboratory (ORNL), aiming to measure the temperature and number density of electrons and temperatures of ions in plasma devices. The PDP has been initially implemented on a high density and low temperature electrothermal arc source (ET-arc) at ORNL to test its TS capability. TS from the plasmas in the ET-arc has been obtained using the PDP. The electron temperature and number density were determined from TS spectra. These results were then compared to measurements from previous studies on the ET-arc. The TS diagnostic measured 0.8 ± 0.1, 1.3 ± 0.2, and 0.7 ± 0.1 eV and (4.4 ± 0.5) × 1021, (5.9 ± 0.7) × 1021, and (4.3 ± 0.5) x 1021 m-3, respectively, from three lines of sight that transect the plasma column.

He, Z. (ORCID:0000000183159882)↗

Electron heat flux dropouts in the solar wind - Evidence for interplanetary magnetic field reconnection?

An examination of ISEE-3 data from 1978 reveal 25 electron heat flux dropout events ranging in duration from 20 min to over 11 hours. The heat flux dropouts are found to occur in association with high plasma densities, low plasma velocities, low ion and electron temperatures, and low magnetic field magnitudes. It is suggested that the heat flux dropout intervals may indicate that the spacecraft is sampling plasma regimes which are magnetically disconnected from the sun and instead are connected to the outer heliosphere at both ends.

Mccomas, D. J.↗

First in operando transient grating spectroscopy measurements on tungsten during high flux plasma operation in PISCES-RF

This work details the construction and first in operando transient grating spectroscopy measurements conducted on PISCES-RF during plasma operation. A preliminary study on a tungsten sample with varied plasma species (Ar and D 2 ), ion flux (4 × 10 21 to 6 × 10 22 ion/m 2 /s), ion energy (5 to 80 eV), and surface temperature (20 to 200 °C) is presented. Prior to plasma exposure, the thermal diffusivity and surface acoustic wave (SAW) speed, (6.9 ± 0.2) × 10 −5 m 2 /s and (2.66 ± 0.02) km/s, were measured in situ with a thermal grating period of 12.5 μm. During Ar plasma exposure, these two quantities vary according to the sample surface temperature. At low flux and varied ion energy, D 2 plasma exposure also results in thermal diffusivity and SAW speed varying with surface temperature alone. At high flux, D 2 plasma exposure results in no convincing change to the thermal diffusivity, but the SAW speed is reduced. After returning to 20 °C, post plasma exposures, the thermal diffusivity and SAW speed almost recover to the initial value prior to exposure.

Surface acoustic wave SAW↗

Probe and radar electron temperatures in an isotropic nonequilibrium plasma.

Electron temperatures measured by electrostatic probes and radar backscatter are distinct physical quantities, the temperature from each technique determined from a different moment of the electron-distribution function. Numerical inequality of temperatures results from a non-Maxwellian electron-distribution function or, equivalently, from a nonequilibrium electron plasma. Probe and backscatter electron temperatures are studied for low- and high-energy (isotropic) distortions of the distribution function. The nonequilibrium plasma generally produces higher probe than backscatter temperatures; however, the temperature difference is small for distortions due to realistic photoelectron populations. If the ionosphere is in a highly nonequilibrium state, probe and backscatter temperatures would differ from the temperature characterizing the average electron kinetic energy, and a single temperature applicable to a variety of physical processes would no longer exist.

Hoegy, W. R.↗

Time-resolved measurements of HO 2 radical in a heated plasma flow reactor

Time-resolved, absolute HO 2 number density in diluted H 2 –O 2 –Ar, CH 4 –O 2 -Ar, and C 2 H 4 –O 2 –Ar mixtures excited by a repetitive ns pulse discharge in a heated plasma flow reactor is measured by Cavity Ringdown Spectroscopy (CRDS). The experimental results are obtained at $\textit{T}$ = 300-600 K and $\textit{P}$ = 130 Torr, both during the discharge pulse burst and in the afterglow. In this work, the HO 2 number density is inferred from the CRDS data using a spectral model exhibiting good agreement with previous measurements of absolute HO 2 absorption cross sections. In the room-temperature H 2 –O 2 mixture, as well as in CH 4 –O 2 and C 2 H 4 –O 2 mixtures over the entire temperature range studied, HO2 is generated only during the discharge burst and decays in the afterglow. However, in the H 2 –O 2 mixture at elevated temperatures, $\textit{T}$ = 400-600 K, HO 2 persists in the afterglow up to 10 ms after the discharge burst, comparable with the flow residence time in the reactor. Comparison with kinetic modeling shows that the sustained reactivity after the source of radicals is turned off is due to a chain propagation / hydrogen oxidation process, which dominates the radical recombination reactions. The kinetic modeling predictions are in good agreement with the relative HO 2 number density measured in all three mixtures, although the model underpredicts the absolute number densities in H 2 –O 2 at $\textit{T}$ = 400-600 K by up to a factor of two. Detection of the sustained low-temperature reactivity in H 2 –O 2 , initiated by the radical generation in the plasma, suggests that the plasma excitation may also affect kinetics of oxidation and reforming of fuels exhibiting low-temperature chemistry below hot ignition point.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma-Catalyst Reactivity Control of Surface Nitrogen Species through Plasma-Temperature-Programmed Hydrogenation to Ammonia

Nonthermal plasma activation of N 2 can facilitate nitrogen adsorption on metal catalysts at low bulk temperatures and atmospheric pressure. Here, we apply a plasma-assisted temperature-programmed reaction (plasma-TPRxn) for ammonia (NH 3 ) synthesis using sequential exposure of a silica-supported metal catalyst to N 2 plasma followed by thermal hydrogen treatment while ramping the temperature to decouple the plasma activation of N 2 from surface catalyzed hydrogenation steps. This approach eliminates the effects from bulk plasma phase reactions, thereby allowing for direct interrogation of plasma activated nitrogen on the active metal surfaces. We confirm previously reported spectroscopic observations that show plasma-generated surface nitrogen can be converted to NH 3 through surface catalyzed pathways. Further, we demonstrate that the ammonia desorption peak temperature is sensitive to metal, with Pt desorbing NH 3 at the lowest temperature. Unsteady state microkinetic models of desorption kinetics as a function of initial N coverage and metal recover observed trends in NH 3 desorption temperatures and confirm that observed results reflect hydrogenation of plasma-induced N accommodation at each surface. In total, we show that the hydrogenation ability of the catalyst after plasma activation of N 2 is responsible for the reactivity trends observed in plasma-assisted NH 3 synthesis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deuterium in carbonaceous chondrites

Hydrogen isotopic compositions in seven carbonaceous chondrites lie in the range -70 to +771 per thousand relative to standard mean ocean water. These values decrease, to a range from -145 to +219 per thousand, after low-temperature oxidation in an oxygen plasma. Deuterium enrichment is therefore concentrated in the organic matter, the hydrous silicates probably lying close to the terrestrial range for such material. Calculated values for delta D of the organic fraction are +450 per thousand for Orgueil and Ivuna and up to +1600 per thousand for Renazzo. These enrichments, at least for Orgueil and Ivuna, suggest equilibration with protosolar hydrogen at very low temperatures. Assuming a value of 2.5 x 10 to the -5th for the protosolar D/H ratio, nominal equilibration temperatures of 230 K for silicates and 180 K for organic matter may be derived.

Kolodny, Y.↗

Deciphering the influence of high-flux helium plasma exposure on tungsten nanostructure growth using real-time, in situ spectroscopic ellipsometry

In situ analysis of surfaces during high-flux plasma exposure represents a long-standing challenge in the study of plasma–material interactions. While post-mortem microscopy can provide a detailed picture of structural and compositional changes, in situ techniques can capture the dynamic evolution of the surface. In this study, we demonstrate how spectroscopic ellipsometry can be applied to the real-time characterization of W nanostructure (also known as “fuzz”) growth during exposure to low temperature, high-flux He plasmas. Strikingly, over a wide range of sample temperatures and helium fluences, the measured ellipsometric parameters (Ψ,Δ) collapse onto a single curve that can be directly correlated with surface morphologies characterized by ex situ helium ion microscopy. The initial variation in the (Ψ,Δ) parameters appears to be governed by small changes in surface roughness (<50 nm) produced by helium bubble nucleation and growth, followed by the emergence of 50 nm diameter W tendrils. This basic behavior appears to be reproducible over a wide parameter space, indicating that the spectroscopic ellipsometry may be of general practical use as a diagnostic to study surface morphologies produced by high-flux He implantation in refractory metals. An advantage of the methods outlined here is that they are applicable at low incident ion energies, even below the sputtering threshold. As an example of this application, we apply in situ ellipsometry to examine how W fuzz growth is affected both by varying ion energy and the temperature of the surface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel method for thermal noise reduction, enabling measurements of broadband, low-amplitude electron temperature fluctuations using individual radiometer channels

A new analysis method has been developed for measurements of broadband, low-amplitude turbulent electron temperature fluctuations in fusion plasmas using individual radiometer channels of a correlation electron cyclotron emission diagnostic. This method takes advantage of differences in the correlation time of thermal noise compared to the correlation time of plasma fluctuations in fusion reactors. The validation of this single-channel method is demonstrated using comparisons with the standard dual-channel radiometer spectral decorrelation method for measurements of turbulent electron temperature fluctuations in the core and edge of low confinement (L), improved confinement (I), and high confinement (H)-mode plasmas at the ASDEX Upgrade tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Positive ion observations in the middle magnetosphere of Jupiter

The positive ion data gathered by the Voyager Plasma Science experiment in the middle magnetosphere of Jupiter are considered. It is pointed out that the experiment measures positive ions with energies per charge between 10 and 5950 V. The observations are analyzed to derive the mass and charge densities, velocity components, and temperatures of the low-energy plasma population. The reduced data set is discussed in terms of the outstanding questions concerning this plasma population and its dynamics. It is found that on the dayside there exists a transonic to highly supersonic positive ion population which tends to move azimuthally but does not rigidly corotate with the planet.

Mcnutt, R. L., Jr.↗

Three-dimensional measurements of fundamental plasma parameters in pulsed ICP operation

Radio frequency inductively coupled plasma sources are widely used in low temperature industrial processing. Recent computer simulations and experiments indicate significant improvement in processing results with the use of pulsed plasmas. We report three dimensional spatial and temporal measurements of fundamental plasma parameters in a pulsed Argon plasma in an industrial etch tool modified for diagnostic access. The pulse repetition rate is 1 kHz with 50% duty cycle. The density does not decay to zero at the end of the afterglow period, and this affects the initial conditions for the beginning of the next powered phase. At 5 mTorr, the plasma starts in the E-mode for each pulse and grows into a “ring” shape density profile. Subsequently, the profile evolves to peak in the middle of the chamber as it reaches a steady state toward the end of the active-glow. At 25 mTorr, the plasma density profile always peaks at the center of the chamber throughout the entire pulse.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron cyclotron resonance (ECR) magnetometry with a plasma reservoir

The local magnetic field in a Penning–Malmberg trap is found by measuring the temperatures that result when electron plasmas are illuminated by microwave pulses. Multiple heating resonances are observed as the pulse frequencies are swept. The many resonances are due to electron bounce and plasma rotation sidebands. The heating peak corresponding to the cyclotron frequency resonance is identified to determine the magnetic field. A new method for quickly preparing low density electron plasmas for destructive temperature measurements enables a rapid and automated scan of microwave frequencies. This technique can determine the magnetic field to high precision, obtaining an absolute accuracy better than 1 ppm and a relative precision of 26 ppb. One important application is in situ magnetometry for antihydrogen-based tests of charge-parity-time symmetry and of the weak equivalence principle.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Room temperature plasma-etching and surface passivation of far-ultraviolet Al mirrors using electron beam generated plasmas

The development of optical systems operating in the far ultraviolet range (FUV, λ=100-200 nm) is limited by the efficiency of passivated aluminum (Al) mirrors. Although it is presently possible to obtain high-reflectivity FUV mirrors through physical vapor deposition, the process involves deposition with substrates at high temperatures, which is technically challenging for large optical elements. A novel passivation procedure for bare Al mirrors is reported. The treatment consisted of using a low-temperature electron-beam generated plasma produced in a gas mixture of Ar and SF6 to etch away the native oxide layer from the Al film, while simultaneously promoting the generation of a thin aluminum tri-fluoride (AlF3) layer on the Al surface. In the first section we analyze the effect of varying both ion energy and SF6 concentration on the FUV reflectance, thickness, composition, and surface morphology of the resulting AlF3 protective layers. In the second section, the reflectivity of samples is optimized at selected important FUV wavelengths for astronomical observations. Notably, samples attained state-of-the-art reflectances of 75% at 108.5 nm (He Lyman γ), 91% at 121.6 nm (H Lyman α), 90% at 130.4 nm (OI), and of 95% at 155.0 nm (C IV). The stability over time of these passivated mirrors is also investigated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Euler equations and the Sod shock tube problem

The Euler equations are a subset of the magnetohydrodynamic (MHD) equations in the infinitely collisional, unmagnetized limit. MHD modeling is central to many areas of plasma physics, ranging from low-temperature glow discharges to inertial confinement fusion. An important aspect of the Euler equations is their ability to describe states with discontinuities, such as shock waves. A standard benchmark test for numerical implementation of the Euler equations is the Sod shock tube. In this test, the system is initialized at rest with a pressure and density discontinuity, which results in a shock wave traveling into the low-pressure region and a rarefaction wave traveling into the high-pressure region. Starting with the presentation of the Euler equations, a numerical algorithm is presented here to solve these equations in one dimension. This is followed by an overview of the Sod shock tube problem that includes the precise initial setup and the analytic solution. Finally, the analytic solution is compared with results from numerical simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The low energy plasma in the Jovian magnetosphere

Measurements below 6 keV from the plasma science experiment on the Voyager spacecraft show that positive ions with temperatures as low as 30 eV to several keV are observed to distances at least as great as 40 Jupiter radii in the dayside Jovian magnetosphere. When velocity determinations are possible between 10 and 40 Jupiter radii, the plasma velocity component along the rigid corotation direction is found to be consistently less than the full corotation speed. Positive ion measurements above 28 keV from the low energy charged particle experiment on Voyager demonstrate the existence of positive ions with temperatures of 20-30 keV at all distances greater than 30 Jupiter radii. Taken together, these observations suggest that the low energy plasma population from 30 to at least 40 Jupiter radii frequently contains both a cold and a hot component. A two-component plasma of this nature may indicate different sources, acceleration mechanisms, or time histories for the disparate components. It may also be indicative of a single acceleration mechanism which is highly energy dependent.

Belcher, J. W.↗

The impact of collisionality on the runaway electron avalanche during a tokamak disruption

The exponential growth (avalanching) of runaway electrons (REs) during a tokamak disruption continues to be a large uncertainty in RE modeling. The present work investigates the impact of tokamak geometry on the efficiency of the avalanche mechanism across a broad range of disruption scenarios. It is found that the parameter ν *,crit ⁠, describing the collisionality at the critical energy to run away, delineates how toroidal geometry impacts RE formation. In particular, utilizing a reduced but self-consistent description of plasma power balance, it is shown that for a high-density deuterium-dominated plasma, ν *,crit is robustly less than one, resulting in a substantial decrease in the efficiency of the RE avalanche compared to predictions from slab geometry. In contrast, for plasmas containing a substantial quantity of neon or argon, ν *,crit ≳1, no reduction of the avalanche is observed due to toroidal geometry. This sharp contrast in the impact of low- vs high-Z material results primarily from the relatively strong radiative cooling from high-Z impurities, enabling the plasma to be radiatively pinned at low temperatures and thus large electric fields, even for modest quantities of high-Z material.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Energetic particle transport and loss induced by helically-trapped energetic-ion-driven resistive interchange modes in the Large Helical Device

Here, energetic-ion confinement and loss due to energetic-ion driven magnetohydrodynamic modes are studied using comprehensive neutron diagnostics and orbit-following numerical simulations for the Large Helical Device (LHD). The neutron flux monitor is employed in order to obtain global confinement of energetic ions and two installed vertical neutron cameras (VNCs) viewing different poloidal cross-sections are utilized in order to measure the radial profile of energetic ions. A strong helically-trapped energetic-ion-driven resistive interchange mode (EIC) excited in relatively low-density plasma terminated high-temperature state in LHD. Changes in the neutron emission profile due to the EIC excitation are clearly visualized by the VNCs. The reduction in the neutron signal for the helical ripple valley increases with EIC amplitude, which reaches approximately 50%. In addition to the EIC experiment, orbit-following simulations using the DELTA5D code with EIC fluctuations were performed to assess the energetic-ion transport and loss. Two-dimensional temporal evolution results show that the neutron emissivity at the helical ripple decreases significantly due to the EIC. The rapid reduction in neutron emissivity shows that the helically-trapped beam ions immediately escape from the plasma. The reduction in the VNC signals for the helical ripple valley and the total neutron emission rate increase with increasing EIC amplitude, as observed in the experiment. Calculated line-integrated neutron emission results show that the profile measured by VNC1 has one peak, whereas the profile measured by VNC2 has two peaks, as observed in the experiment. Although the neutron emission profile for VNC2 has a relatively wide peak compared with the experimental results, the significant decrease in neutron signal corresponding to the helical ripple valley was successfully reproduced.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗