Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC MATERIALS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Location of nanophase Fe-oxides in palagonitic soils: Implication for Martian pigments

Palagonitic materials from Mauna Kea, Hawaii, were identified as Mars analogs based on their spectral and magnetic properties. These materials probably resulted from hydrothermal alteration during eruption of the volcano and/or from weathering under ambient conditions. The reflectance spectra of the Mars surface obtained by Earth-based telescopes and the reflectance spectra of analogs obtained in the laboratory show features due to electronic transitions of Fe(III) in oxide particles that range in size from nanometer (nanophase) to micrometer sized or larger. The presence of Fe(III) suggests oxidizing conditions during the alteration process in Mars that may have occurred in the past or during a slow ongoing process. Two naturally altered basaltic samples from Hawaii (HWMK12 and HWMK13) and a laboratory-altered (PH-13-DCGT2) basaltic glass similar in elemental composition to the above two samples was examined. All three samples exhibited spectral characteristics similar to martian bright-region spectra. Chemical and mineralogical changes occurring at the surface of these basalts were studied in order to understand the basis for their Mars-like properties. The spectral properties of the three samples were examined after the removal of Fe oxides by chemical extractants.

Golden, D. C.↗

Physical Models for Accreting Pulsars at High Luminosity

A new window for better understanding the accretion onto strongly magnetized neutron stars in X-ray binaries is opening. In these systems the accreted material follows the magnetic field lines as it approaches the neutron star, forming accretion columns above the magnetic poles. The plasma falls toward the neutron star surface at near-relativistic speeds, losing energy by emitting X-rays. The X-ray spectral continua are commonly described using phenomenological models, i.e., power laws with different types of curved cut-offs at higher energies. Here we consider high luminosity pulsars. In these systems the mass transfer rate is high enough that the accreting plasma is thought to be decelerated in a radiation-dominated radiative shock in the accretion columns. While the theory of the emission from such shocks had already been developed by 2007, a model for direct comparison with X-ray continuum spectra in xspec or isis has only recently become available. Here we analyze the broadband X-ray spectra of the accreting pulsars Centaurus X-3 and 4U1626-67 obtained withNuSTAR. We present results from traditional empirical modeling as well as successfully apply the radiation-dominated radiative shock model. We also fit the energy-dependent pulse profiles of 4U 1626-67 using a new relativistic light bending model.

Pottschmidt, Katja↗

The development of a containment vessel and Dewar for the particle astrophysics magnet facility (ASTROMAG)

The ASTROMAG facility is the heart of a large charged particle detection and resolution system. ASTROMAG utilizes a superconducting magnet consisting of a large superconducting magnet coil with a stored magnetic energy of approximately 15 MJ. The active coil will have a mass of 1200 kg. This magnet will be cooled by a cryostat using a liquid helium Dewar for storage. The cryostat will have a series of gas-cooled shields with an external guard vacuum shield and an internal Dewar. The magnet and cryostat will be designed for shuttle or Delta launch and will be designed to withstand the internal pressure of expanded helium under full quench conditions when venting is prevented. The external guard vacuum shell is required to maintain a vacuum for Earth based testing and for cold launch of the cryostat and magnet. The magnet is designed to operate at 4.4 K with a peak field of 7.0 tesla. The superconducting material within the magnet is niobium titanium in a conductive matrix.

Source record↗

GRC Supporting Technology for NASA's Advanced Stirling Radioisotope Generator (ASRG)

From 1999 to 2006, the NASA Glenn Research Center (GRC) supported a NASA project to develop a high-efficiency, nominal 110-We Stirling Radioisotope Generator (SRG110) for potential use on NASA missions. Lockheed Martin was selected as the System Integration Contractor for the SRG110, under contract to the Department of Energy (DOE). The potential applications included deep space missions, and Mars rovers. The project was redirected in 2006 to make use of the Advanced Stirling Convertor (ASC) that was being developed by Sunpower, Inc. under contract to GRC, which would reduce the mass of the generator and increase the power output. This change would approximately double the specific power and result in the Advanced Stirling Radioisotope Generator (ASRG). The SRG110 supporting technology effort at GRC was replanned to support the integration of the Sunpower convertor and the ASRG. This paper describes the ASRG supporting technology effort at GRC and provides details of the contributions in some of the key areas. The GRC tasks include convertor extended-operation testing in air and in thermal vacuum environments, heater head life assessment, materials studies, permanent magnet characterization and aging tests, structural dynamics testing, electromagnetic interference and electromagnetic compatibility characterization, evaluation of organic materials, reliability studies, and analysis to support controller development.

Schreiber, Jeffrey G.↗

A Cryogenic Magnetostrictive Actuator Using a Persistent High Temperature Superconducting Magnet: Concept and Design - Part 1

Cryogenic magnetostrictive materials, such as rare earth zinc crystals, offer high strains and high forces with minimally applied magnetic fields, making the material ideally suited for deformable optics applications. For cryogenic temperature applications the use of superconducting magnets offer the possibility of a persistent mode of operation, i.e., the magnetostrictive material will maintain a strain field without power. High temperature superconductors (HTS) are attractive options if the temperature of operation is higher than 10 degrees Kelvin (K) and below 77 K. However, HTS wires have constraints that limit the minimum radius of winding, and even if good wires can be produced, the technology for joining superconducting wires does not exist. In this paper, the design and capabilities of a rare earth zinc magnetostrictive actuator using bulk HTS is described. Bulk superconductors can be fabricated in the sizes required with excellent superconducting properties. Equivalent permanent magnets, made with this inexpensive material, are persistent, do not require a persistent switch as in HTS wires, and can be made very small. These devices are charged using a technique which is similar to the one used for charging permanent magnets, e.g., by driving them into saturation. A small normal conducting coil can be used for charging or discharging. Because of the magnetic field capability of the superconductor material, a very small amount of superconducting magnet material is needed to actuate the rare earth zinc. In this paper, several designs of actuators using YBCO and BSCCO 2212 superconducting materials are presented. Designs that include magnetic shielding to prevent interaction between adjacent actuators will also be described. Preliminary experimental results and comparison with theory for BSCCO 2212 with a magnetostrictive element will be discussed.

Horner, Garnett↗

High temperature permeameter for measuring magnetic properties

Instrument for measuring magnetic permeability of materials undergoing heat treatment as method for monitoring stress relief and tempering is described. Procedure is based on magnetic potentiometer principle with yoke compensating coils to cancel effects of reluctance of yoke and joint gaps. Instrument is heated with specimen being heat treated.

Barranger, J. P.↗

Evidence for a non-random magnetization of the moon

An approximate inversion, using a specific model, of Apollo subsatellite vector magnetometer data has provided estimates for the locations, scale sizes, and magnetization characteristics of strongly magnetized lunar crustal materials across a portion of the lunar far side. The nearly model-independent local bulk directions of magnetization, while otherwise random, exhibit a tendency to lie in or near planes perpendicular to the present lunar spin axis. The apparent existence of such a preferred plane of magnetization must be regarded as unfavorable for proposed local, presumably random sources of large-scale, coherent magnetization and implies that any assumed internal magnetizing dipole or external linear magnetizing field must also have been oriented mainly perpendicular to the present spin axis. The otherwise random orientations of these vectors when projected onto the equatorial plane suggests a simple explanation for the negligible lunar global dipole moment.

Hood, L.↗

Final Results for the GRC Supporting Technology Development Project for the 110-Watt Stirling Radioisotope Generator (SRG110)

From 1999-2006, the NASA Glenn Research Center (GRC) supported the development of a high-efficiency, nominal 110-We Stirling Radioisotope Generator (SRG110) for potential use on NASA missions, including deep space missions, Mars rovers, and lunar applications. Lockheed Martin (LM) was the system integrator for the SRG110, under contract to the Department of Energy (DOE). Infinia Corporation (formerly Stirling Technology Company) developed the Stirling convertor, first as a contractor to DOE and then under subcontract to LM. The SRG110 development has been redirected, and recent program changes have been made to significantly increase the specific power of the generator. System development of an Advanced Stirling Radioisotope Generator (ASRG) has now begun, using a lightweight, advanced convertor from Sunpower, Inc. This paper summarizes the results of the supporting technology effort that GRC completed for the SRG110. GRC tasks included convertor extended-duration testing in air and thermal vacuum environments, heater head life assessment, materials studies, permanent magnet aging characterization, linear alternator evaluations, structural dynamics testing, electromagnetic interference (EMI) and electromagnetic compatibility (EMC) characterization, organic materials evaluations, reliability studies, and development of an end-to-end system dynamic model. Related efforts are now continuing in many of these areas to support ASRG development.

Schreiber, Jeffrey G.↗

Final Results for the GRC Supporting Technology Development Project for the 110-Watt Stirling Radioisotope Generator (SRG110)

From 1999 to 2006, the NASA Glenn Research Center (GRC) supported the development of a high-efficiency, nominal 110-We Stirling Radioisotope Generator (SRG110) for potential use on NASA missions, including deep space missions, Mars rovers, and lunar applications. Lockheed Martin (LM) was the system integrator for the SRG110, under contract to the Department of Energy (DOE). Infinia Corporation (formerly Stirling Technology Company) developed the Stirling convertor, first as a contractor to DOE and then under subcontract to LM. The SRG110 development has been redirected, and recent program changes have been made to significantly increase the specific power of the generator. System development of an Advanced Stirling Radioisotope Generator (ASRG) has now begun, using a lightweight, advanced convertor from Sunpower, Inc. This paper summarizes the results of the supporting technology effort that GRC completed for the SRG110. GRC tasks included convertor extended-duration testing in air and thermal vacuum environments, heater head life assessment, materials studies, permanent magnet aging characterization, linear alternator evaluations, structural dynamics testing, electromagnetic interference (EMI) and electromagnetic compatibility (EMC) characterization, organic materials evaluations, reliability studies, and development of an end-to-end system dynamic model. Related efforts are now continuing in many of these areas to support ASRG development.

Schreiber, Jeffrey G.↗

Infrared radiation from interstellar grains.

IR radiation from interstellar grains, measuring intensity as wavelength function and radiation polarization for information on grain temperature and composition and galactic magnetic fields

INTERSTELLAR MATERIAL↗

Adhesion in ceramics and magnetic media

When a ceramic is brought into contact with a metal or a polymeric material such as a magnetic medium, strong bonds form between the materials. For ceramic-to-metal contacts, adhesion and friction are strongly dependent on the ductility of the metals. Hardness of metals plays a much more important role in adhesion and friction than does the surface energy of metals. Adhesion, friction, surface energy, and hardness of a metal are all related to its Young's modulus and shear modulus, which have a marked dependence on the electron configuration of the metal. An increase in shear modulus results in a decrease in area of contact that is greater than the corresponding increase in surface energy (the fond energy) with shear modulus. Consequently, the adhesion and friction decrease with increasing shear modulus. For ceramics in contact with polymeric magnetic tapes, environment is extremely important. For example, a nitrogen environment reduces adhesion and friction when ferrite contacts polymeric tape, whereas a vacuum environment strengthens the ferrite-to-tape adhesion and increases friction. Adhesion and friction are strongly dependent on the particle loading of the tape. An increase in magnetic particle concentration increases the complex modulus of the tape, and a lower real area of contact and lower friction result.

Miyoshi, Kazuhisa↗

Material condition assessment with eddy current sensors

Eddy current sensors and sensor arrays are used for process quality and material condition assessment of conducting materials. In an embodiment, changes in spatially registered high resolution images taken before and after cold work processing reflect the quality of the process, such as intensity and coverage. These images also permit the suppression or removal of local outlier variations. Anisotropy in a material property, such as magnetic permeability or electrical conductivity, can be intentionally introduced and used to assess material condition resulting from an operation, such as a cold work or heat treatment. The anisotropy is determined by sensors that provide directional property measurements. The sensor directionality arises from constructs that use a linear conducting drive segment to impose the magnetic field in a test material. Maintaining the orientation of this drive segment, and associated sense elements, relative to a material edge provides enhanced sensitivity for crack detection at edges.

Goldfine, Neil J.↗

Radially Focused Eddy Current Sensor for Detection of Longitudinal Flaws in Metallic Tubes

A radially focused eddy current sensor detects longitudinal flaws in a metal tube. A drive coil induces eddy currents within the wall of the metal tube. A pick-up cod is spaced apart from the drive coil along the length of the metal tube. The pick@up coil is positioned with one end thereof lying adjacent the wall of the metal tube such that the pick-up coil's longitudinal axis is perpendicular to the wall of the metal tube. To isolate the pick-up coil from the magnetic flux of the drive coil and the flux from the induced eddy currents. except the eddy currents diverted by a longitudinal flaw. an electrically conducting material high in magnetic permeability surrounds all of the pick-up coil except its one end that is adjacent the walls of the metal tube. The electrically conducting material can extend into and through the drive coil in a coaxial relationship therewith.

Wincheski, Russell A.↗

Effect of Graphene Addition on Shape Memory Behavior of Epoxy Resins

Shape memory polymers (SMPs) and composites are a special class of smart materials known for their ability to change size and shape upon exposure to an external stimulus (e.g. light, heat, pH, or magnetic field). These materials are commonly used for biomedical applications; however, recent attempts have been made towards developing SMPs and composites for use in aircraft and space applications. Implementing SMPs and composites to create a shape change effect in some aircraft structures could potentially reduce drag, decrease fuel consumption, and improve engine performance. This paper discusses the development of suitable materials to use in morphing aircraft structures. Thermally responsive epoxy SMPs and nanocomposites were developed and the shape memory behavior and thermo-mechanical properties were studied. Overall, preliminary results from dynamic mechanical analysis (DMA) showed that thermally actuated shape memory epoxies and nanocomposites possessed Tgs near approximately 168 C. When graphene nanofiller was added, the storage modulus and crosslinking density decreased. On the other hand, the addition of graphene enhanced the recovery behavior of the shape memory nanocomposites. It was assumed that the addition of graphene improved shape memory recovery by reducing the crosslinking density and increasing the elasticity of the nanocomposites.

Williams, Tiffany↗

Design and material selection for inverter transformer cores

Report is announced which studied magnetic properties of candidate materials for use in spacecraft transformers, static inverters, converters, and transformer-rectifier power supplies. Included are material characteristics for available alloy compositions in tabular form, including: trade names, saturated flux density, dc coercive force, loop squareness, material density, and watts per pound at 3 KHz.

Mclyman, W. T.↗

A Large Ordinary Chondrite Shower in the Dominion Range

The US Antarctic Meteorite Program has visited the Dominion Range in the Transantarctic Mountains during several different seasons, including the 1985, 2003, 2008, 2010, and 2014 seasons. Total recovered meteorites from this region is over 2000. The 2008 and 2010 seasons have been fully classified and, respectively) revealing the presence of a large meteorite shower that comprises approximately 60% of all samples recovered in those two seasons. The oil immersion classification suggests that this shower is LL chondrite material, whereas published magnetic susceptibility (MS; log chi) measurements yield L chondrite values. However, usually random sampling of a large collection like this would uncover EOC material for which we have prepared thin sections. In this case, no LL chondrite materials have been found in thin section, suggesting that the shower might instead be an L chondrite. L and LL chondrites are notoriously difficult to distinguish using oil immersion techniques. To better characterize this large group of samples, we have decided to examine some of the large members of this group, using EMPA analysis of the olivines to verify the classifications. With a compositional link between this subset of samples, and the MS measurements, we can more confidently classify the samples making up this pairing group. Subsequently, more accurate and meaningful comparisons may be drawn between this pairing group and some other Antarctic pairing groups such as from the Queen Alexandra Range (QUE), and Lewis Cliffs Ice Tongue (LEW). electron microprobe analysis

Satterwhite, C. E.↗

Optimum dimensions of power solenoids for magnetic suspension

Design optimization of power solenoids for controllable and stabilizable magnetic suspensions with force compensation in a wind tunnel is shown. It is assumed that the model of a levitating body is a sphere of ferromagnetic material with constant magnetic permeability. This sphere, with a radius much smaller than its distance from the solenoid above, is to be maintained in position on the solenoid axis by balance of the vertical electromagnetic force and the force of gravitation. The necessary vertical (axial) force generated by the solenoid is expressed as a function of relevant system dimensions, solenoid design parameters, and physical properties of the body. Three families of curves are obtained which depict the solenoid power for a given force as a function of the solenoid length with either outside radius or inside radius as a variable parameter and as a function of the outside radius with inside radius as a variable parameter. The curves indicate the optimum solenoid length and outside radius, for minimum power, corresponding to a given outside radius and inside radius, respectively.

Kaznacheyev, B. A.↗