Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEDICAL ELECTRONICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Design and Principles of Linear Accelerators and Colliders." in Particle Physics Reference Library, pp. 295-336. Springer, Cham, 2020.

Linear accelerators (linacs) use alternating radiofrequency (RF) electromagnetic fields to accelerate charged particles in a straight line. Linacs were invented about 95 years ago and have seen many significant technical innovations since. A wide range of particle beams have been accelerated with linacs including beams of electrons, positrons, protons, antiprotons, and heavy ions. Linac parameter possibilities include pulsed versus continuous wave, low and high beam powers, low and high repetition rates, low transverse emittance beams, short bunches with small energy spreads, and accelerated multiple bunches in a single pulse. The number of linacs around the world has grown tremendously with thousands of linacs in present use, many for medical therapy, in industry, and for research and development in a broad spectrum of scientific fields. Researchers have developed accelerators for scientific tools in their own right, being awarded several Nobel prizes. Moreover, linacs and particle accelerators in general have enabled many discovery level science experiments in related fields, resulting in many Nobel prizes as well.

Seeman, John↗

Ontologizing health systems data at scale: making translational discovery a reality

Common data models solve many challenges of standardizing electronic health record (EHR) data but are unable to semantically integrate all of the resources needed for deep phenotyping. Open Biological and Biomedical Ontology (OBO) Foundry ontologies provide computable representations of biological knowledge and enable the integration of heterogeneous data. However, mapping EHR data to OBO ontologies requires significant manual curation and domain expertise. We introduce OMOP2OBO, an algorithm for mapping Observational Medical Outcomes Partnership (OMOP) vocabularies to OBO ontologies. Using OMOP2OBO, we produced mappings for 92,367 conditions, 8611 drug ingredients, and 10,673 measurement results, which covered 68–99% of concepts used in clinical practice when examined across 24 hospitals. When used to phenotype rare disease patients, the mappings helped systematically identify undiagnosed patients who might benefit from genetic testing. By aligning OMOP vocabularies to OBO ontologies our algorithm presents new opportunities to advance EHR-based deep phenotyping.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Electric Potential and Electric Field Imaging with Applications

The technology and techniques for remote quantitative imaging of electrostatic potentials and electrostatic fields in and around objects and in free space is presented. Electric field imaging (EFI) technology may be applied to characterize intrinsic or existing electric potentials and electric fields, or an externally generated electrostatic field may be used for (illuminating) volumes to be inspected with EFI. The baseline sensor technology, electric field sensor (e-sensor), and its construction, optional electric field generation (quasistatic generator), and current e-sensor enhancements (ephemeral e-sensor) are discussed. Demonstrations for structural, electronic, human, and memory applications are shown. This new EFI capability is demonstrated to reveal characterization of electric charge distribution, creating a new field of study that embraces areas of interest including electrostatic discharge mitigation, crime scene forensics, design and materials selection for advanced sensors, dielectric morphology of structures, inspection of containers, inspection for hidden objects, tether integrity, organic molecular memory, and medical diagnostic and treatment efficacy applications such as cardiac polarization wave propagation and electromyography imaging.

Generazio, Ed↗

The working principle of hybrid perovskite gamma-ray photon counter

Gamma-ray spectroscopy that quantifies the gamma-ray energies is a critical technology widely needed in astrophysics, nuclear material detection and medical treatment. The key is to precisely count gamma-ray photons using sensitive detectors. In this paper, we investigate the operational principles of chlorine-doped methylammonium lead tribromide (MAPbBr 3-x Cl x ) perovskite single crystal detectors that can efficiently count gamma-ray photon events with electrical pulses. Specifically, we find the main dark current originates from the thermally activated electron injection from the impurities, and using high work function contacts can block out the dark noise thus allows for efficient pulse collection at higher electrical fields ~500 V/cm. As a result, we observe strong electrical pulses when exposing the detector under radioactive sources emitting gamma-ray photons at various energies. Our results also reveal the fundamental issues that prevent the reliable observation of photo-electric peak. This work suggest pathway towards energy resolved gamma-ray spectroscopy using perovskite crystal detectors.

36 MATERIALS SCIENCE↗

Spaceborne Accelerators Portfolio

MeV-range, satellite-mounted electron accelerators are needed for various space-related applications, such measuring the coupling between the magnetotail and ionosphere. The technologies and design approaches being developed for spaceborne accelerators emphasize high reliability, high average power, flexible operation, efficient power use, and operation from low-voltage DC power supplies. These same attributes are also relevant to industrial processing and inspection as well as medical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

PSEC5 Physical Verification

Ultra-Fast timing detectors, having a time resolution of 10pSec or less, are becoming increasingly important for many scientific disciplines, including High Energy Physics, Nuclear Physics, Medical Imaging and more. When developing ultra-fast detectors such as MCPs, LAPPDs, LGADs, SNSPDs, it is necessary to have access to a readout system that is low power, can support many channels and is cost effective. The PSEC5 chip was an application specific integrated circuit (ASIC) developed by the pioneering group of Prof. Henry Frisch at University of Chicago and micro electronic engineers at Fermi National Accelerator Laboratory. Three boards were designed, two to implement the readout system for an LAPPD and one to only characterize the PSEC1 chip. The main goal of the project shifted to setting up a testing environment to focus on the characterization of the chip. My student and I tested and characterized this ASIC using the third chip-on-board printed circuit board. Results show the successful fabrication and operation of some of the key building blocks and lead to the suggestions on modification for the second iteration of the chip.

Rico Aniles, H. D. [Unlisted]↗

Bio-medical flow sensor

A bio-medical flow sensor including a packageable unit of a bottle, tubing and hypodermic needle which can be pre-sterilized and is disposable. The tubing has spaced apart tubular metal segments. The temperature of the metal segments and fluid flow therein is sensed by thermistors and at a downstream location heat is input by a resistor to the metal segment by a control electronics. The fluids flow and the electrical power required for the resisto to maintain a constant temperature differential between the tubular metal segments is a measurable function of fluid flow through the tubing. The differential temperature measurement is made in a control electronics and also can be used to control a flow control valve or pump on the tubing to maintain a constant flow in the tubing and to shut off the tubing when air is present in the tubing.

Winkler, H. E.↗

Development of Collaborative Research Initiatives to Advance the Aerospace Sciences-via the Communications, Electronics, Information Systems Focus Group

The primary goal of the Adaptive Vision Laboratory Research project was to develop advanced computer vision systems for automatic target recognition. The approach used in this effort combined several machine learning paradigms including evolutionary learning algorithms, neural networks, and adaptive clustering techniques to develop the E-MOR.PH system. This system is capable of generating pattern recognition systems to solve a wide variety of complex recognition tasks. A series of simulation experiments were conducted using E-MORPH to solve problems in OCR, military target recognition, industrial inspection, and medical image analysis. The bulk of the funds provided through this grant were used to purchase computer hardware and software to support these computationally intensive simulations. The payoff from this effort is the reduced need for human involvement in the design and implementation of recognition systems. We have shown that the techniques used in E-MORPH are generic and readily transition to other problem domains. Specifically, E-MORPH is multi-phase evolutionary leaming system that evolves cooperative sets of features detectors and combines their response using an adaptive classifier to form a complete pattern recognition system. The system can operate on binary or grayscale images. In our most recent experiments, we used multi-resolution images that are formed by applying a Gabor wavelet transform to a set of grayscale input images. To begin the leaming process, candidate chips are extracted from the multi-resolution images to form a training set and a test set. A population of detector sets is randomly initialized to start the evolutionary process. Using a combination of evolutionary programming and genetic algorithms, the feature detectors are enhanced to solve a recognition problem. The design of E-MORPH and recognition results for a complex problem in medical image analysis are described at the end of this report. The specific task involves the identification of vertebrae in x-ray images of human spinal columns. This problem is extremely challenging because the individual vertebra exhibit variation in shape, scale, orientation, and contrast. E-MORPH generated several accurate recognition systems to solve this task. This dual use of this ATR technology clearly demonstrates the flexibility and power of our approach.

Knasel, T. Michael↗

ARCH: Large-scale knowledge graph via aggregated narrative codified health records analysis

Objective: Electronic health record (EHR) systems contain a wealth of clinical data stored as both codified data and free-text narrative notes (NLP). The complexity of EHR presents challenges in feature representation, information extraction, and uncertainty quantification. Here, to address these challenges, we proposed an efficient Aggregated naRrative Codified Health (ARCH) records analysis to generate a large-scale knowledge graph (KG) for a comprehensive set of EHR codified and narrative features. Methods: Using data from 12.5 million Veterans Affairs patients, ARCH first derives embedding vectors and generates similarities along with associated p-values to measure the strength of relatedness between clinical features with statistical certainty quantification. Next, ARCH performs a sparse embedding regression to remove indirect linkage between features to build a sparse KG. Finally, ARCH was validated on various clinical tasks, including detecting known relationships between entity pairs, predicting drug side effects, disease phenotyping, as well as sub-typing Alzheimer’s disease patients. Results: ARCH produces high-quality clinical embeddings and KG for over 60,000 codified and narrative EHR concepts. The KG and embeddings are visualized in the R-shiny powered web-API.3 ARCH achieved high accuracy in detecting EHR concept relationships, with AUCs of 0.926 (codified) and 0.861 (NLP) for similar EHR concepts, and 0.810 (codified) and 0.843 (NLP) for related pairs. It detected drug side effects with a 0.723 AUC, which improved to 0.826 after fine-tuning. Using both codified and NLP features, the detection power increased significantly. Compared to other methods, ARCH has superior accuracy and enhances weakly supervised phenotyping algorithms’ performance. Notably, it successfully categorized Alzheimer’s patients into two subgroups with varying mortality rates. Conclusion: The proposed ARCH algorithm generates large-scale high-quality semantic representations and knowledge graph for both codified and NLP EHR features, useful for a wide range of predictive modeling tasks.

Electronic health records↗

Synthesis and Characterization of Silver-Modified Nanoporous Silica Materials for Enhanced Iodine Removal

In aquatic environments, the presence of iodine species, including radioactive isotopes like 129 I and I 2 , poses significant environmental and health concerns. Iodine can enter water resources from various sources, including nuclear accidents, medical procedures, and natural occurrences. To address this issue, the use of natural occurring nanoporous minerals, such as zeolitic materials, for iodine removal will be explored. This study focuses on the adsorption of iodine by silver-modified zeolites (13X-Ag, 5A-Ag, Chabazite-Ag, and Clinoptilolite-Ag) and evaluates their performance under different conditions. All materials were characterized using scanning electron microscopey (SEM), energy-dispersive X-ray spectroscopy (EDS), powdered X-ray diffraction (P-XRD), Fourier-transform infrared spectrometry (FTIR), and nitrogen adsorption studies. The results indicate that Chabazite-Ag exhibited the highest iodine adsorption capacity, with an impressive 769 mg/g, making it a viable option for iodine removal applications. 13X-Ag and 5A-Ag also demonstrated substantial adsorption capacities of 714 mg/g and 556 mg/g, respectively, though their behavior varied according to different models. In contrast, Clinoptilolite-Ag exhibited strong pH-dependent behavior, rendering it less suitable for neutral to slightly acidic conditions. Furthermore, this study explored the impact of ionic strength on iodine adsorption, revealing that Chabazite-Ag is efficient in low-salinity environments with an iodine adsorption capacity of 51.80 mg/g but less effective in saline conditions. 5A-Ag proved to be a versatile option for various water treatments, maintaining its iodine adsorption capacity across different salinity levels. In contrast, Clinoptilolite-Ag exhibited high sensitivity to ionic competition, virtually losing its iodine adsorption ability at a NaCl concentration of 0.1 M. Kinetic studies indicated that the pseudo-second-order model best describes the adsorption process, suggesting chemisorption mechanisms dominate iodine removal. Chabazite-Ag exhibited the highest initial adsorption rate with a k 2 value of 0.002 mg g -1 h -1 , emphasizing its superior adsorption capabilities. Chabazite and Clinoptilolite, naturally occurring minerals, provide eco-friendly solutions for iodine adsorption. Chabazite superior iodine removal highlights its value in critical applications and its potential for addressing pressing environmental challenges.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Telemedicine: An expanding new science on land and sea

Several medical and technical men in San Diego County are concerned with the need in many rural communities for a 24-hour day, 7-days a week access to adequate medical care. People isolated from urban areas by travel-times of 40-minutes tend to delay seeking early and effective medical care. The authors were able to assemble quality technology which permits narrow-band video-pictures, better known in the CB trade as ROBOT slow-scan television (SSTV), to be transmitted over telephone lines, by micro-wave, through satellite-bounce, or by HF-radio. These 'ROBOT' pictures can be accompanied with explanatory audio communication and with diagnostic signals from electronic instruments.

Jackman, K. R.↗

Profile of Ambulance Runs at the Kennedy Space Center

The Kennedy Space Center (KSC) has four onsite ambulances staffed with Paramedics at two fire stations that respond to 911 Emergency Medical System (EMS) medical dispatches. These ambulances serve over 22,000 NASA, military, government, and contractor employees in an area of approximately 520 square miles. Included in this coverage are several public areas such as beaches, a wildlife refuge and a popular Visitor Center. Reports are filled out on each patient encountered. However. the only element tracked has been the ambulance response time. Now that reports are filed electronically, it is possible to enter them into an electronic database for analysis. Data analyses reveal trends and assist in better allocation of resources.

Scarpa, Philip J.↗

Application of Fresnel Zone to Cross Talk

Unintentional radiation results in cross coupling to nearby cables. As frequency increases, the amount of this coupling becomes significant especially in high speed data transmission and space lab experiments. There has been a considerable amount of research to model this radiation and design the electronic equipment accordingly so that operation of space lab instruments will be immune to unwanted radiation. Here at MSFC, the Electromagnetics and Aerospace Environment Branch has the responsibility to analyze, test, and make the necessary recommendation as to the safe operation of instruments used in the space program. Rules, regulation, and limits as set by this group are published in Electromagnetic Compatibility Design and Interference Control (MEDIC) Handbook. This document contains both conducted and radiate emission rules and limits are set by NASA. However cross coupling have not been included. At the time of assigning the research task for the author, the Group decided that a more in-depth investigation of Near Field is needed before establishing a set of rules and limits for cross coupling. Thus this task was assigned to the author with hope that his work will be more beneficial to NASA's Space mission experiments. The model and the method which will be described shortly is intended to improve the present approach of this Group and suggests a method for measuring the cross field coupling capacitance.

Javan, Hank↗

Northstar Mo100 Target Beam Spot Size Sensitivity Study

Northstar Mo100 target for production of the medical isotope Mo99 is particularly sensitive to beam over focusing because of the intended high power density. At 38 MeV and 6.32 mA (240 kW beam power, nominally 160 kW th in the target), small deviation from the nominal 12 mm FWHM beam can significantly increase the target disk temperatures and more importantly the load bearing target window temperature. A rhodotron will be the source of the electron beam to be used in the isotope production. This machine operates in a pulsed beam mode, currently expected to be at 50 Hz, which results in a 100 C temperature oscillation above and below the steady state temperature that is the focus of this study. This must be considered in the determination of minimum beam spot size that can be accepted by the target without risk of failure. In addition to the nominal beam spot size of 12 mm, the analysis of 10, 11 and 14.5 mm beam spot sizes are analyzed. The primary conclusion is that an over focused beam to just 11 mm FWHM is the minimum beam spot allowable, based on window temperature and the Ultimate Tensile Stress (UTS) of the window material Inconel 718 as a function of temperature. In contrast an under focused beam of 14.5 mm FWHM has much reduced target and window temperatures, but there is a resulting 6% drop in isotope production, all other factor staying the same. These results are presented herein.

07 ISOTOPE AND RADIATION SOURCES↗

Physics through the 1990s: Scientific interfaces and technological applications

The volume examines the scientific interfaces and technological applications of physics. Twelve areas are dealt with: biological physics-biophysics, the brain, and theoretical biology; the physics-chemistry interface-instrumentation, surfaces, neutron and synchrotron radiation, polymers, organic electronic materials; materials science; geophysics-tectonics, the atmosphere and oceans, planets, drilling and seismic exploration, and remote sensing; computational physics-complex systems and applications in basic research; mathematics-field theory and chaos; microelectronics-integrated circuits, miniaturization, future trends; optical information technologies-fiber optics and photonics; instrumentation; physics applications to energy needs and the environment; national security-devices, weapons, and arms control; medical physics-radiology, ultrasonics, MNR, and photonics. An executive summary and many chapters contain recommendations regarding funding, education, industry participation, small-group university research and large facility programs, government agency programs, and computer database needs.

Source record↗

Wearable Health Monitoring Systems

The shrinking size and weight of electronic circuitry has given rise to a new generation of smart clothing that enables biological data to be measured and transmitted. As the variation in the number and type of deployable devices and sensors increases, technology must allow their seamless integration so they can be electrically powered, operated, and recharged over a digital pathway. Nyx Illuminated Clothing Company has developed a lightweight health monitoring system that integrates medical sensors, electrodes, electrical connections, circuits, and a power supply into a single wearable assembly. The system is comfortable, bendable in three dimensions, durable, waterproof, and washable. The innovation will allow astronaut health monitoring in a variety of real-time scenarios, with data stored in digital memory for later use in a medical database. Potential commercial uses are numerous, as the technology enables medical personnel to noninvasively monitor patient vital signs in a multitude of health care settings and applications.

Bell, John↗

Computational and Experimental Evaluation of Peroxide Oxidants for Amine-Peroxide Redox Polymerization

Amine–peroxide redox polymerization (APRP) is the prevalent method for producing radical-based polymers in the many industrial and medical applications where light or heat activation is impractical. We recently developed a detailed description of the APRP initiation process through a combined computational and experimental effort to show that APRP proceeds through SN2 attack by the amine on the peroxide, followed by the rate-determining homolysis of the resulting intermediate. Using this new mechanistic understanding, a variety of peroxides were computationally predicted to initiate APRP with fast kinetics. In particular, the rate of APRP initiation can be improved by radical and anion stabilization through increased p-electron conjugation or by increasing the electrophilicity of the peroxy bond through the addition of electron-withdrawing groups. On the other hand, the addition of electron-donating groups lowered the initiation rate. These design principles enabled the computational prediction of several new peroxides that exhibited improved initiation rates over the commonly used benzoyl peroxide. For example, the addition of nitro groups (NO2) to the para positions of benzoyl peroxide resulted in a theoretical radical generation rate of 1.9 × 10–9 s–1, which is ~150 times faster than the 1.3 × 10–11 s–1 radical generation rate observed with unsubstituted benzoyl peroxide. These accelerated kinetics enabled the development of a redox-based direct-writing process that exploited the extremely rapid reactivity of an optimized redox pair with a custom inkjet printer, capable of printing custom shapes from polymerizing resins without heat or light. Furthermore, the application of more rapid APRP kinetics could enable the acceleration of existing industrial processes, make new industrial manufacturing methods possible, and improve APRP compatibility with biomedical applications through reduced initiator concentrations that still produce rapid polymerization rates.

functional polymers↗

Unique cell culture systems for ground based research

The horizontally rotating fluid-filled, membrane oxygenated bioreactors developed at NASA Johnson for spacecraft applications provide a powerful tool for ground-based research. Three-dimensional aggregates formed by cells cultured on microcarrier beads are useful for study of cell-cell interactions and tissue development. By comparing electron micrographs of plant seedlings germinated during Shuttle flight 61-C and in an earth-based rotating bioreactor it is shown that some effects of microgravity are mimicked. Bioreactors used in the UAH Bioreactor Laboratory will make it possible to determine some of the effects of altered gravity at the cellular level. Bioreactors can be valuable for performing critical, preliminary-to-spaceflight experiments as well as medical investigations such as in vitro tumor cell growth and chemotherapeutic drug response; the enrichment of stem cells from bone marrow; and the effect of altered gravity on bone and muscle cell growth and function and immune response depression.

Lewis, Marian L.↗