Search NASA⌕ Search

SEARCH · Search NASA

Results for “MIRROR RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Two mirror X-ray pulse split and delay instrument for femtosecond time resolved investigations at the LCLS free electron laser facility

We built a two-mirror based X-ray split and delay (XRSD) device for soft X-rays at the Linac Coherent Light Source free electron laser facility. The instrument is based on an edge-polished mirror design covering an energy range of 250 eV-1800 eV and producing a delay between the two split pulses variable up to 400 femtoseconds with a sub-100 attosecond resolution. We present experimental and simulation results regarding molecular dissociation dynamics in CH3I and CO probed by the XRSD device. In conclusion, we observed ion kinetic energy and branching ratio dependence on the delay times which were reliably produced by the XRSD instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The helium-to-hydrogen ratio of the UV-bright star Barnard 29 of Messier 13

Barnard 29 is the most luminous UV-bright star of the globular cluster Messier 13. Comparison of its reddening corrected optical region spectrophotometry and IUE low dispersion fluxes and its H-gamma profile with the predictions of metal-poor model atmospheres having the metallicity of M 13 indicated T(sub eff) = 20250 K, log g = 3.15. Observations of He I lambda(4026) taken with echelle spectrograph of the Multi-Mirror telescope using a Reticon detector show that He/H = 0.055 +/- 0.020. Some astrophysical implications of this result are discussed.

Adelman, S. J.↗

Focusing adaptive-optics for neutron spectroscopy at extreme conditions

Neutron Spectroscopy employing extreme-conditions sample environments is nowadays a crucial tool for the understanding of fundamental scientific questions as well as for the investigation of materials and chemical-physical properties. For all these kinds of studies, an increased neutron flux over a small sample area is needed. The prototype of a focusing neutron guide component, developed and produced completely at the neutron source FRM II in Garching (Germany), has been installed at the time-of-flight (TOF) disc-chopper neutron spectrometer TOFTOF and came into routine-operation. The design is based on the compressed Archimedes' mirror concept for finite-size divergent sources. It represents a unique device combining the supermirror technology with Adaptive Optics, suitable for broad-bandwidth thermal-cold TOF neutron spectroscopy (here optimized for 1.4–10 Å). It is able to squeeze the beam cross section down to a square centimeter, with a more than doubled signal-to-background ratio, increased efficiency at high scattering angles, and improved symmetry of the elastic resolution function. We present a comparison between the simulated and measured beam cross sections, as well as the performance of the instrument within real experiments. This work intends to show the unprecedented opportunities achievable at already existing instruments, along with useful guidelines for the design and construction of next-generation neutron spectrometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Space Technology for Directly Imaging and Characterizing Exo-Earths

The detection of Earth-like exoplanets in the habitable zone of their stars, and their spectroscopic characteri- zation in a search for biosignatures, requires starlight suppression that exceeds the current best ground-based performance by orders of magnitude. The required planet/star brightness ratio of order 10-10 at visible wave-lengths can be obtained by blocking stellar photons with an occulter, either externally (a starshade) or internally (a coronagraph) to the telescope system, and managing diffracted starlight, so as to directly image the exoplanet in reflected starlight. Coronagraph instruments require advancement in telescope aperture (either monolithic or segmented), aperture obscurations (obscured by secondary mirror and its support struts), and wavefront error sensitivity (e.g. line-of-sight jitter, telescope vibration, polarization). The starshade, which has never been used in a science application, benefits a mission by being decoupled from the telescope, allowing a loosening of telescope stability requirements. In doing so, it transfers the difficult technology from the telescope system to a large deployable structure (tens of meters to greater than 100 m in diameter) that must be positioned precisely at a distance of tens of thousands of kilometers from the telescope. We describe in this paper a roadmap to achieving the technological capability to search for biosignatures on an Earth-like exoplanet from a future space telescope. Two of these studies, HabEx and LUVOIR, include the direct imaging of Earth-sized habitable exoplanets as a central science theme.

Crill, Brendan P.↗

Aplanatic two-mirror telescopes: A systematic study. I - Cassegrainian configuration

A systematic performance analysis of aplanatic Cassegrainian telescopes has been accomplished by means of a ray trace program. The results indicate that the available field angle for a given geometric spot size is, to a very close approximation, a function of the relative back focal distance only. Image curvatures, as computed by third-order theory and by the ray trace program, were found to be in very close agreement. Image curvature is plotted as a function of the ray height ratio for a wide range of secondary magnification.

Wyman, C. L.↗

Ultrasensitive measurement of microcantilever displacement below the shot-noise limit

The displacement of micro-electro-mechanical-systems (MEMs) cantilevers is used to measure a variety of phe- nomena in devices ranging from force microscopes for single spin detection[1] to biochemical sensors[2] to un- cooled thermal imaging systems[3]. The displacement readout is often performed optically with segmented de- tectors or interference measurements. Until recently, var- ious noise sources have limited the minimum detectable displacement in MEMs systems, but it is now possible to minimize all other sources[4] so that the noise level of the coherent light eld, called the shot noise limit (SNL), becomes the dominant source. Light sources dis- playing quantum-enhanced statistics below this limit are available[5, 6], with applications in gravitational wave astronomy[7] and bioimaging[8], but direct displacement measurements of MEMS cantilevers below the SNL have been impossible until now. Here, we demonstrate the rst direct measurement of a MEMs cantilever displace- ment with sub-SNL sensitivity, thus enabling ultratrace sensing, imaging, and microscopy applications. By com- bining multi-spatial-mode quantum light sources with a simple dierential measurement, we show that sub-SNL MEMs displacement sensitivity is highly accessible com- pared to previous eorts that measured the displacement of macroscopic mirrors with very distinct spatial struc- tures crafted with multiple optical parametric ampliers and locking loops[9]. We apply this technique to a com- mercially available microcantilever in order to detect dis- placements 60% below the SNL at frequencies where the microcantilever is shot-noise-limited. These results sup- port a new class of quantum MEMS sensor whose ulti- mate signal to noise ratio is determined by the correla- tions possible in quantum optics systems.

47 OTHER INSTRUMENTATION↗

Planar Collisionless Shock Simulations with the Semi-implicit Particle-in-cell Model FLEKS

This study investigates the applicability of the semi-implicit particle-in-cell code FLexible Exascale Kinetic Simulator (FLEKS) to heliospheric shock simulations. We examine one- and two-dimensional local planar shock simulations, initialized using MHD states with upstream conditions representative of plasmas in the hypersonic, β ∼ 1 regime, for both quasi-perpendicular and quasi-parallel configurations. The refined algorithm in FLEKS proves robust, enabling accurate shock simulations with a grid resolution on the order of the electron inertial length d e . Our simulations successfully capture key shock features, including shock structures (foot, ramp, overshoot, and undershoot), upstream and downstream waves (fast magnetosonic, whistler, Alfvén ion-cyclotron, and mirror modes), and non-Maxwellian particle distributions. Crucially, we find that at least two spatial dimensions are critical for accurately reproducing downstream-wave physics in quasi-perpendicular shocks and capturing the complex dynamics of quasi-parallel shocks, including surface rippling, shocklets, short, large-amplitude magnetic structures, magnetic reconnection, and jets. Furthermore, our parameter studies demonstrate the impact of mass ratio and grid resolution on shock physics. This work provides valuable guidance for selecting appropriate physical and numerical parameters for shock simulations using a semi-implicit PIC method, paving the way for incorporating kinetic shock processes into large-scale collisionless plasma simulations with the MHD-AEPIC model.

plasma astrophysics↗

Optical instruments

A wide angle, low focal ratio, high resolution, catoptric, image plane scanner is described. The scanner includes the following features: (1) a reflective improvement on the Schmidt principle, (2) a polar line scanner in which all field elements are brought to and corrected on axis, and (3) a scanner arrangement in which the aperture stop of the system is imaged at the center of curvature of a spherical primary mirror. The system scans are a large radial angle and an extremely high rate of speed with relatively small scanning mirrors. Because the system is symmetrical about the optical axis, the obscuration is independent of the scan angle.

Abel, I. R.↗

A new rapid method of solar simulator calibration

A quick method for checking solar simulator spectra content is presented. The method is based upon a solar cell of extended spectral sensitivity and known absolute response, and a dichroic mirror with the reflection transmission transition close to the peak wavelength of the Thekaekara AMO distribution. It compromises the need for spectral discrimination with the ability to integrate wide spectral regions of the distribution which was considered important due to the spiky nature of the high pressure xenon lamp in common use. The results are expressed in terms of a single number, the blue/red ratio, which, combined with the total (unfiltered) output, provides a simple adequate characterization. Measurements were conducted at eleven major facilities across the country and a total of eighteen simulators were measured including five pulsed units.

Ross, B.↗

The Limb Infrared Monitor of the Stratosphere /LIMS/ experiment - Temperature and nitrogen dioxide results

The Limb Infrared Monitor of the Stratosphere (LIMS) is a satellite-borne radiometer which scans across the earth's limb, measuring infrared radiation emitted by specific atmospheric gases in a number of broad channels. Instrumentation includes a folded telescope, which focuses the radiation from the limb onto an array of six mercury-cadmium-telluride detectors. A scan mirror within the telescope sweeps the fields of view across the horizon, with each up or down scan lasting 12 seconds. The measurements are inverted to yield distributions of temperature and nitrogen dioxide. The temperature is determined from two channels covering the intervals 595-739 per cm and 645-673 per cm of the 15 micron bands of CO2, with maximum signal to noise ratio of 500-1000. Nitrogen dioxide is determined from measurements in a channel from 1580-1613 per cm, with an S/N of approximately 100. Results show that the LIMS temperature and nitrogen dioxide data are characterized by high precision.

Gille, J. C.↗

Terrestrial Planet Finder coronagraph pointing control system design and evaluation for flight baseline 1.

The Terrestrial Planet Finder mission will search for Earth-like, extrasolar planets. The Coronagraph architecture option (TPF-C) will use contrast imaging to suppress the bright starlight in order to detect reflected visible light from the planet. To achieve the required contrast ratio stability of 2e-11, the payload pointing stability must be maintained to better than 4 milli-asec (1σ). The passive TPF-C pointing architecture uses a 3-stage control system combined with a 2- stage passive isolation system to achieve the required pointing accuracy. The active pointing stage includes reaction wheels used for coarse pointing of the spacecraft, a position controlled secondary mirror that provides intermediate alignment, and a Fine Guidance Mirror that provides fine steering control.

Dewell, Larry↗

Graphite Composite Panel Polishing Fixture

The use of high-strength, lightweight composites for the fixture is the novel feature of this innovation. The main advantage is the light weight and high stiffness-to-mass ratio relative to aluminum. Meter-class optics require support during the grinding/polishing process with large tools. The use of aluminum as a polishing fixture is standard, with pitch providing a compliant layer to allow support without deformation. Unfortunately, with meter-scale optics, a meter-scale fixture weighs over 120 lb (.55 kg) and may distort the optics being fabricated by loading the mirror and/or tool used in fabrication. The use of composite structures that are lightweight yet stiff allows standard techniques to be used while providing for a decrease in fixture weight by almost 70 percent. Mounts classically used to support large mirrors during fabrication are especially heavy and difficult to handle. The mount must be especially stiff to avoid deformation during the optical fabrication process, where a very large and heavy lap often can distort the mount and optic being fabricated. If the optic is placed on top of the lapping tool, the weight of the optic and the fixture can distort the lap. Fixtures to support the mirror during fabrication are often very large plates of aluminum, often 2 in. (.5 cm) or more in thickness and weight upwards of 150 lb (68 kg). With the addition of a backing material such as pitch and the mirror itself, the assembly can often weigh over 250 lb (.113 kg) for a meter-class optic. This innovation is the use of a lightweight graphite panel with an aluminum honeycomb core for use as the polishing fixture. These materials have been used in the aerospace industry as structural members due to their light weight and high stiffness. The grinding polishing fixture consists of the graphite composite panel, fittings, and fixtures to allow interface to the polishing machine, and introduction of pitch buttons to support the optic under fabrication. In its operation, the grinding polishing fixture acts as a reaction structure to the polishing tool. It must be stiff enough to avoid imparting a distorted shape to the optic under fabrication and light enough to avoid self-deflection. The fixture must also withstand significant tangential loads from the polishing machine during operations.

Hagopian, John↗

Techniques for High Contrast Imaging in Multi-Star Systems II: Multi-Star Wavefront Control

Direct imaging of exoplanets represents a challenge for astronomical instrumentation due to the high-contrast ratio and small angular separation between the host star and the faint planet. Multi-star systems pose additional challenges for coronagraphic instruments because of the diffraction and aberration leakage introduced by the additional stars, and as a result are not planned to be on direct imaging target lists. Multi-star wavefront control (MSWC) is a technique that uses a coronagraphic instrument's deformable mirror (DM) to create high-contrast regions in the focal plane in the presence of multiple stars. Our previous paper introduced the Super-Nyquist Wavefront Control (SNWC) technique that uses a diffraction grating to enable the DM to generate high-contrast regions beyond the nominal controllable region. These two techniques can be combined to generate high-contrast regions for multi-star systems at any angular separations. As a case study, a high-contrast wavefront control (WC) simulation that applies these techniques shows that the habitable region of the Alpha Centauri system can be imaged reaching 8 times 10(exp -9) mean contrast in 10 percent broadband light in one-sided dark holes from 1.6-5.5 lambda (wavelength) divided by D (distance).

Sirbu, D.↗

Advanced Raman water vapor lidar

Water vapor and aerosols are important atmospheric constituents. Knowledge of the structure of water vapor is important in understanding convective development, atmospheric stability, the interaction of the atmosphere with the surface, and energy feedback mechanisms and how they relate to global warming calculations. The Raman Lidar group at the NASA Goddard Space Flight Center (GSFC) developed an advanced Raman Lidar for use in measuring water vapor and aerosols in the earth's atmosphere. Drawing on the experience gained through the development and use of our previous Nd:YAG based system, we have developed a completely new lidar system which uses a XeF excimer laser and a large scanning mirror. The additional power of the excimer and the considerably improved optical throughput of the system have resulted in approximately a factor of 25 improvement in system performance for nighttime measurements. Every component of the current system has new design concepts incorporated. The lidar system consists of two mobile trailers; the first (13m x 2.4m) houses the lidar instrument, the other (9.75m x 2.4m) is for system control, realtime data display, and analysis. The laser transmitter is a Lambda Physik LPX 240 iCC operating at 400 Hz with a XeF gas mixture (351 nm). The telescope is a .75m horizontally mounted Dall-Kirkham system which is bore sited with a .8m x 1.1m elliptical flat which has a full 180 degree scan capability - horizon to horizon within a plane perpendicular to the long axis of the trailer. The telescope and scan mirror assembly are mounted on a 3.65m x .9m optical table which deploys out the rear of the trailer through the use of a motor driven slide rail system. The Raman returns from water vapor (403 nm), nitrogen (383 nm) and oxygen (372 nm) are measured in addition to the direct Rayleigh/Mie backscatter (351). The signal from each of these is split at about a 5/95 ratio between two photomultiplier detectors. The 5 percent detector is used for measurements below about 4.0 km, while the 95 percent detector provides the information above this level.

Whiteman, David N.↗

CONSTRAINING EXPLOSION TYPE OF YOUNG SUPERNOVA REMNANTS USING 24 {mu}m EMISSION MORPHOLOGY

Determination of the explosion type of supernova remnants (SNRs) can be challenging, as SNRs are hundreds to thousands of years old and supernovae are classified based on spectral properties days after explosion. Previous studies of thermal X-ray emission from Milky Way and Large Magellanic Cloud SNRs have shown that Type Ia and core-collapse (CC) SNRs have statistically different symmetries, and thus these sources can be typed based on their X-ray morphologies. In this Letter, we extend the same technique, a multipole expansion technique using power ratios, to infrared (IR) images of SNRs to test whether they can be typed using the symmetry of their warm dust emission as well. We analyzed archival Spitzer Space Telescope Multiband Imaging Photometer 24 {mu}m observations of the previously used X-ray sample, and we find that the two classes of SNRs separate according to their IR morphologies. The Type Ia SNRs are statistically more circular and mirror symmetric than the CC SNRs, likely due to the different circumstellar environments and explosion geometries of the progenitors. Broadly, our work indicates that the IR emission retains information of the explosive origins of the SNR and offers a new method to type SNRs based on IR morphology.

79 ASTRONOMY AND ASTROPHYSICS↗

Strawman Optical Reception Development Antenna (SORDA)

A strawman design of a ground-based station for receiving optical communications from deep space is presented. This strawman will serve as a basis for further study and design refinement. The recommendation to build rather than to use an existing facility is explained. Parameters of the design were selected to postulate a workable system, starting with a 10 m diameter, hexagonally segmented, f/0.5 primary mirror. The effects of variations of design parameters on performance and cost are discussed. Some design formulas are included. An electro-optical functional block diagram is presented and discussed. Cost calculations are based on a previous cost model for the hardware or on typical construction costs per unit area for several types of facilities. Other cost factors are included in the usual way for Construction of Facilities. The ratio of high and low reasonable values was less than a factor of 2, with a best estimate of under $16,000,000.

Kerr, E. L.↗

The Influence of Roughness on Gear Surface Fatigue

Gear working surfaces are subjected to repeated rolling and sliding contacts, and often designs require loads sufficient to cause eventual fatigue of the surface. This research provides experimental data and analytical tools to further the understanding of the causal relationship of gear surface roughness to surface fatigue. The research included evaluations and developments of statistical tools for gear fatigue data, experimental evaluation of the surface fatigue lives of superfinished gears with a near-mirror quality, and evaluations of the experiments by analytical methods and surface inspections. Alternative statistical methods were evaluated using Monte Carlo studies leading to a final recommendation to describe gear fatigue data using a Weibull distribution, maximum likelihood estimates of shape and scale parameters, and a presumed zero-valued location parameter. A new method was developed for comparing two datasets by extending the current methods of likelihood-ratio based statistics. The surface fatigue lives of superfinished gears were evaluated by carefully controlled experiments, and it is shown conclusively that superfinishing of gears can provide for significantly greater lives relative to ground gears. The measured life improvement was approximately a factor of five. To assist with application of this finding to products, the experimental condition was evaluated. The fatigue life results were expressed in terms of specific film thickness and shown to be consistent with bearing data. Elastohydrodynamic and stress analyses were completed to relate the stress condition to fatigue. Smooth-surface models do not adequately explain the improved fatigue lives. Based on analyses using a rough surface model, it is concluded that the improved fatigue lives of superfinished gears is due to a reduced rate of near-surface micropitting fatigue processes, not due to any reduced rate of spalling (sub-surface) fatigue processes. To complete the evaluations, surface inspection were completed. The surface topographies of the ground gears changed substantially due to running, but the topographies of the superfinished gears were essentially unchanged with running.

Krantz, Timothy↗

The CXRS diagnostic for ITER and the CXRS-Pilot Experiment on TEXTOR

Charge eXchange Recombination Spectroscopy (CXRS) will play a crucial role in the diagnosing of burning plasmas: items like helium ash, transport barriers, impurity content or fuel ratio can all be assessed with CXRS. In fact this is the only direct method to obtain information about the light impurity ions, such as temperature, concentrations and rotation, in the core of the plasma. Two of such systems are foreseen at ITER, one in the upper port plug and one on the equatorial level, both viewing the 100 keV diagnostic H-beam.Challenges for this diagnostic development project are: constructing a mirror close to the plasma able to keep its reflectivity under the extreme bombardment by neutrons, erosion by fast neutrals and deposition of sputtered material, design of an optical labyrinth with well enough neutron shielding, developing spectrometers with a throughput about a factor 100 larger than on present day devices, with a similar or better dispersion, calibration and alignment techniques and last but not least, finding ways to obtain the physics relevant information from the measured complicated spectra in real time.With all these issues in mind, an ITER-CXRS pilot experiment has been developed and became operational on the TEXTOR tokamak, to address some of the above aspects. The results of this show the feasibility and the sensitivity of the ITER system: the simulation code for ITER signal levels could be verified, the sensitivity to the current profile has been tested, the beam emission has been compared to beam attenuation calculations and used to obtain absolute impurity concentrations and a high throughput spectrometer became operational.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗