Hourly natural gas usage surrounding NIST NEB and NWB GHG monitoring stations in 2023

This dataset includes hourly natural gas usage surrounding two National Institute of Standards and Technology (NIST) greenhouse gas (GHG) monitoring stations, Northwest Baltimore (NWB; 39.3445°N, 76.6851°W) and Northeast Baltimore (NEB; 39.3154°N, 76.5830°W), for the year 2023 in units of therms. The gas usage was provided by the local gas distribution company and includes hourly data averaged across groups of 15 or more addresses to maintain anonymity. The hourly data was averaged spatially within a radius of 1 km from each monitoring station, including all groups containing data from any address within 1km of the monitoring station. This dataset only includes gas usage from service points equipped with advanced metering infrastructure (AMI). Between the two monitoring sites, this dataset includes usage from a total of 3649 service points, which we estimate is at least 44% of the service points in the domain.

Kenion, Helen C. R. [School of Environment and Sus↗

Study program of NASA/GSFC weld quality monitor system

The Weld Quality Monitor has provided online control through the application of linear transducers. The electronic systems must be upgraded to increase confidence level required in production. The Weld Quality Monitor has been used with a recent model solid state power supply to evaluate ability to differentiate between sound and defective weld joints. The Weld Quality Monitor has been evaluated on Dumet and Kovar to interconnect materials Nickel and Alloy 180 in weld joints used on microelectronic module fabrication. Distinct separation was achieved between low strength welds and sound welds by the Quality Monitor. Evaluation performed indicates a drift level at less than 2 percent on a series of 50 consecutive welds. Operation under shop conditions identified need for controlled electrode impact. This was achieved with pneumatic actuation.

Hutchinson, W. R.↗

Space shuttle propulsion systems on-board checkout and monitoring system development study

Investigations on the fundamental space shuttle propulsion systems program are reported, with emphasis on in-depth reviews of preliminary drafts of the guidelines. The guidelines will be used to incorporate the onboard checkout and monitoring function into the basic design of the propulsion systems and associated interfacing systems. The analysis of checkout and monitoring requirements of the Titan 3 L expandable booster propulsion systems was completed, and the techniques for accomplishing the checkout and monitoring functions were determined. Updating results of the basic study of propulsion system checkout and monitoring is continuing.

Source record↗

A contaminant monitor for submarine atmospheres.

A requirement for monitoring selected atmospheric constituents on board nuclear powered submarines has been met by the development of the Central Atmosphere Monitoring System, Mark I. This system employs a mass spectrometer to monitor H2, H2O, N2, O2, CO2, Freon 11, Freon 12, and Freon 114, in addition to an infrared sensor for CO. The CAMS MKI development is discussed, including background, operating fundamentals, principal requirements, functional and physical descriptions, and summarized test results. Each of two prototype units has successfully completed over 9000 hr of operational sea trails, providing the necessary ground work for the manufacture of production units. At the same time, these units, which have benefited extensively from NASA hardware experience, may in turn provide useful data for the development of a new class of maintainable atmospheric monitoring instrumentation for manned spacecraft.

Ruecker, M. R.↗

Flight study of a vehicle operational status and monitoring system

An analog onboard monitoring system was installed on a YF-12 airplane as the first phase of a program to monitor the engine inlet and portions of the airplane's electrical and fuel management subsystems in flight. The system provided data which were considered to form a suitable base for diagnostic test logic and decision criteria for the rest of the program. The data were also adequate for the purpose of maintaining the engine inlet and identifying malfunctions within it. The investigation showed that the requirements of an onboard monitoring system should be considered during the original design of the system to be monitored.

Love, J. E.↗

LANDSAT-1 data as it has been applied for land use and water quality data by the Virginia State Water Control Board. 1: The state project. 2: Monitoring water quality from LANDSAT

LANDSAT-1 imagery has been used for water quality and land use monitoring in and around the Swift Creek and Lake Chesdin Reservoirs in Virginia. This has proved useful by (1) helping determine valid reservoir sampling stations, (2) monitoring areas not accessible by land or water, (3) giving the State a viable means of measuring Secchi depth readings in these inaccessible areas, (4) giving an overview of trends in changing sedimentation loadings over a given time period and classifying these waters into various categories, (5) enabling the State to inventory all major lakes and reservoirs and computing their acreage, (6) monitoring land use changes in any specific area, (7) evaluating possible long-term environmental effects of nearby developments, and (8) monitoring and predicting population shifts with possible impact on water quality problems. The main problems in the long-term use of such imagery appear to be cost and lack of consistency due to cloud cover limitations.

Trexler, P. L.↗

Microprocessor-based multichannel flutter monitor using dynamic strain gage signals

Two microprocessor-based multichannel monitors for monitoring strain gage signals during aerodynamic instability (flutter) testing in production type turbojet engines were described. One system monitors strain gage signals in the time domain and gives an output indication whenever the signal amplitude of any gage exceeds a pre-set alarm or abort level for that particular gage. The second system monitors the strain gage signals in the frequency domain and therefore is able to use both the amplitude and frequency information. Thus, an alarm signal is given whenever the spectral content of the strain gage signal exceeds, at any point, its corresponding amplitude vs. frequency limit profiles. Each system design is described with details on design trade-offs, hardware, software, and operating experience.

Smalley, R. R.↗

A method and data for video monitor sizing

The paper outlines an approach consisting of using analytical methods and empirical data to determine monitor size constraints based on the human operator's CRT viewing requirements in a context where panel space and volume considerations for the Space Shuttle aft cabin constrain the size of the monitor to be used. Two cases are examined: remote scene imaging and alphanumeric character display. The central parameter used to constrain monitor size is the ratio M/L where M is the monitor dimension and L the viewing distance. The study is restricted largely to 525 line video systems having an SNR of 32 db and bandwidth of 4.5 MHz. Degradation in these parameters would require changes in the empirically determined visual angle constants presented. The data and methods described are considered to apply to cases where operators are required to view via TV target objects which are well differentiated from the background and where the background is relatively sparse. It is also necessary to identify the critical target dimensions and cues.

Kirkpatrick, M., III↗

Microprocessor-based multichannel flutter monitor using dynamic strain gage signals

Two microprocessor-based multichannel monitors are described for monitoring strain gage signals during aerodynamic instability (flutter) testing in production type turbojet engines. One system monitors strain gage signals in the time domain and gives an output indication whenever the signal amplitude of any gage exceeds a pre-set alarm or abort level for that particular gage. The second system monitors the strain gage signals in the frequency domain and therefore is able to use both the amplitude and frequency information. Thus, an alarm signal is given whenever the spectral content of the strain gage signal exceeds, at any point, its corresponding amplitude vs frequency limit profile. Each system design is described with details on design trade-offs, hardware, software, and operating experience.

Smalley, R. R.↗

Definition of air quality measurements for monitoring space shuttle launches

A description of a recommended air quality monitoring network to characterize the impact on ambient air quality in the Kennedy Space Center (KSC) (area) of space shuttle launch operations is given. Analysis of ground cloud processes and prevalent meteorological conditions indicates that transient HCl depositions can be a cause for concern. The system designed to monitor HCl employs an extensive network of inexpensive detectors combined with a central analysis device. An acid rain network is also recommended. A quantitative measure of projected minimal long-term impact involves the limited monitoring of NOx and particulates. All recommended monitoring is confined ti KSC property.

Thorpe, R. D.↗

Systems identification and application systems development for monitoring the physiological and health status of crewmen in space

The use of automated, analytical techniques to aid medical support teams is suggested. Recommendations are presented for characterizing crew health in terms of: (1) wholebody function including physiological, psychological and performance factors; (2) a combination of critical performance indexes which consist of multiple factors of measurable parameters; (3) specific responses to low noise level stress tests; and (4) probabilities of future performance based on present and periodic examination of past performance. A concept is proposed for a computerized real time biomedical monitoring and health care system that would have the capability to integrate monitored data, detect off-nominal conditions based on current knowledge of spaceflight responses, predict future health status, and assist in diagnosis and alternative therapies. Mathematical models could play an important role in this approach, especially when operating in a real time mode. Recommendations are presented to update the present health monitoring systems in terms of recent advances in computer technology and biomedical monitoring systems.

Leonard, J. I.↗

Air quality monitor and acid rain networks

The air quality monitor program which consists of two permanent air monitor stations (PAMS's) and four mobile shuttle pollutant air monitor stations (SPAMS's) is evaluated. The PAMS measures SO sub X, NO sub X particulates, CO, O3, and nonmethane hydrocarbons. The SPAMS measures O3, SO2, HCl, and particulates. The collection and analysis of data in the rain monitor program are discussed.

Rudolph, H.↗

DSN Monitor and Control System, Mark III-80

The Deep Space Network monitor and control system, Mark III-80 is described. The major implementations required to evolve from the Mark III-78 to the Mark III-80 configuration are identified. The affected facilities are the deep space stations and the network operations control center (NOCC). At the deep space stations a stand-alone host processor is implemented. Included are software (host software) changes which provide downline loading to the stand-alone host processor from a disc unit of any idle data system computer. At deep space stations with a 34 m antenna, the microwave subsystem is provided with an interface which allows remote configuration selection at the central monitor and control operator's position. In the NOCC, software changes are implemented to provide precision power monitor and GCF monitor displays.

Leflang, J. G.↗

X-ray all-sky monitors

Considerations for an all-sky monitor for the Ariel-5 mission are evaluated. The monitors with the best signal-to-noise utilize the pinhole-camera principle, and are also least expensive in hardware and data analysis costs. The sensitivity sufficient to sensibly monitor compact extragalactic sources requires a system with approximately 100 times the sensitivity of the Ariel-5 ASM. A system identical in size to the Ariel-5 ASM can be made with approximately 5 times better sensitivity, and can satisfy the minimum requirements for this mission if it spins. An all-sky monitor appears to be essential to assure that rare occurrences in compact objects can be observed with the pointed experiment, and to ascertain that large amounts of pointing time will not be wasted by observing at the wrong times.

Holt, S. S.↗

Pulsed Phase-Locked-Loop Strain Monitor

P2sup.L2sup. strain monitor measures strain by monitoring change in phase of acoustic signal that passes through stressed sample. Phase sample causes shift in frequency of VCO. As with other monitors of this type, instrument is only accurate in elastic range of material. Monitor is expected to have broad application in materials testing, structural design, fabrication and assembly.

Heyman, J. S.↗

Audio distribution and Monitoring Circuit

Versatile circuit accepts and distributes TV audio signals. Three-meter audio distribution and monitoring circuit provides flexibility in monitoring, mixing, and distributing audio inputs and outputs at various signal and impedance levels. Program material is simultaneously monitored on three channels, or single-channel version built to monitor transmitted or received signal levels, drive speakers, interface to building communications, and drive long-line circuits.

Kirkland, J. M.↗

A model of human decision making in multiple process monitoring situations

Human decision making in multiple process monitoring situations is considered. It is proposed that human decision making in many multiple process monitoring situations can be modeled in terms of the human's detection of process related events and his allocation of attention among processes once he feels event have occurred. A mathematical model of human event detection and attention allocation performance in multiple process monitoring situations is developed. An assumption made in developing the model is that, in attempting to detect events, the human generates estimates of the probabilities that events have occurred. An elementary pattern recognition technique, discriminant analysis, is used to model the human's generation of these probability estimates. The performance of the model is compared to that of four subjects in a multiple process monitoring situation requiring allocation of attention among processes.

Greenstein, J. S.↗

Results from a 'small box' realtime molecular contamination monitor on STS-3

On the basis of early estimates of the Shuttle induced environment, Scialdone (1979) concluded that in the vicinity of the cargo, the cargo would have the largest influence on the environment. As a contamination control device, realtime monitors can indicate safe operational periods for sensitive attached payloads. It was, therefore, decided to develop the OSS-1/Contamination Monitor Package (CMP) experiment which was seen as a forerunner of an operational monitor. A description of the CMP is provided, taking into account four actively temperature controlled quartz crystal microbalances (TQCM). The TQCM temperatures could be varied from -60 C to +80 C. The sensor consisted of a matched pair of quartz crystals. The crystals were designated as a sensor and reference crystal. Results obtained during the STS-3 mission are discussed. These results show the feasibility and advantages of a small real-time contamination monitor.

Triolo, J.↗