A Multiple-Input-Multiple-Output Acoustic Test Using Structural Responses to Derive Acoustic INputs.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract Not Provided
Abstract not provided.
Disclosed herein are representative embodiments of methods, apparatus, and systems for performing neutron radiography. For example, in one exemplary method, an object is interrogated with a plurality of neutrons. The plurality of neutrons includes a first portion of neutrons generated from a first neutron source and a second portion of neutrons generated from a second neutron source. Further, at least some of the first portion and the second portion are generated during a same time period. In the exemplary method, one or more neutrons from the first portion and one or more neutrons from the second portion are detected, and an image of the object is generated based at least in part on the detected neutrons from the first portion and the detected neutrons from the second portion.
Abstract not provided.
Abstract not provided.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Neutron multiplicity counting is the most commonly used nondestructive assay technique for determining the plutonium mass within containers of scrap PuO 2 or mixed oxide (MOX). In multiplicity analysis, the 240 Pu eff mass, leakage multiplication, and alpha ratio (the ratio of [α, n]-to-spontaneous fission neutron production) are the three primary unknown sample properties. They must be determined simultaneously. To solve for these three unknowns in a multiplicity assay, three measured values are needed: the singles, doubles, and triples neutron count rates. While the analysis is limited to solving for three unknowns, there are many additional factors that impact the observed count rates and contribute to the measurement uncertainty. In this study we investigate the various uncertainty contributors for the multiplicity analysis through a combination of traditional uncertainty propagation techniques supplemented by Monte Carlo simulations to address the dependences not explicitly expressed by the point source model. Uncertainties arising from counting statistics, calibration parameters, calibration method, nuclear data, and various material characteristics (isotopic abundances, chemical form, density, and impurities) are considered. A Total Measurement Uncertainty (TMU) estimate is then developed from these uncertainty contributors. This study is confined to multiplicity analysis of items commonly encountered in international safeguards applications. That is, the study focused on Pu oxides and MOX materials for the masses ranging up to 4000 grams total Pu. Multiplicity measurements were simulated using MCNP V6 based on the Plutonium Scrap Multiplicity Counter (PSMC), Epithermal Multiplicity Counter (ENMC), Pyrochemical Multiplicity Counter, and Large Epithermal Multiplicity Counter (LEMC) for this study; however, this report focuses on the parameterization of the uncertainties for the PSMC. The performance differences between the PSMC and the other multiplicity counting systems are relatively small, primarily manifesting in the impact on measurement precision so that the evaluation developed for the PSMC can be applied to the other multiplicity counting systems. Finally an analysis tool, the Multiplicity TMU Estimator, was developed from this study to serve as an aid for evaluation of the total measurement uncertainty of multiplicity assay results obtained from the commonly used INCC acquisition and analysis software.
Multiple myeloma is a plasma cell malignancy with an unmet clinical need for improved imaging methods and therapeutics. Recently, we identified CD46 as an overexpressed therapeutic target in multiple myeloma and developed the antibody YS5, which targets a cancer-specific epitope on this protein. We further developed the CD46-targeting PET probe [ 89 Zr]Zr-DFO-YS5 for imaging and [ 225 Ac]Ac-DOTA-YS5 for radiopharmaceutical therapy of prostate cancer. These prior studies suggested the feasibility of the CD46 antigen as a theranostic target in multiple myeloma. Herein, we validate [ 89 Zr]Zr-DFO-YS5 for immunoPET imaging and [ 225 Ac]Ac-DOTA-YS5 for radiopharmaceutical therapy of multiple myeloma in murine models. In vitro saturation binding was performed using the CD46 expressing MM.1S multiple myeloma cell line. ImmunoPET imaging using [ 89 Zr]Zr-DFO-YS5 was performed in immunodeficient (NSG) mice bearing subcutaneous and systemic multiple myeloma xenografts. For radioligand therapy, [ 225 Ac]Ac-DOTA-YS5 was prepared, and both dose escalation and fractionated dose treatment studies were performed in mice bearing MM1.S-Luc systemic xenografts. Tumor burden was analyzed using BLI, and body weight and overall survival were recorded to assess antitumor effect and toxicity. [ 89 Zr]Zr-DFO-YS5 demonstrated high affinity for CD46 expressing MM.1S multiple myeloma cells (K d = 16.3 nmol/L). In vitro assays in multiple myeloma cell lines demonstrated high binding, and bioinformatics analysis of human multiple myeloma samples revealed high CD46 expression. [ 89 Zr]Zr-DFO-YS5 PET/CT specifically detected multiple myeloma lesions in a variety of models, with low uptake in controls, including CD46 knockout (KO) mice or multiple myeloma mice using a nontargeted antibody. In the MM.1S systemic model, localization of uptake on PET imaging correlated well with the luciferase expression from tumor cells. A treatment study using [ 225 Ac]Ac-DOTA-YS5 in the MM.1S systemic model demonstrated a clear tumor volume and survival benefit in the treated groups. Our study showed that the CD46-targeted probe [ 89 Zr]Zr-DFO-YS5 can successfully image CD46-expressing multiple myeloma xenografts in murine models, and [ 225 Ac]Ac-DOTA-YS5 can effectively inhibit the growth of multiple myeloma. These results demonstrate that CD46 is a promising theranostic target for multiple myeloma, with the potential for clinical translation.
Total Measurement Uncertainty (TMU) in neutron assays of transuranic waste (TRU) are comprised of several components including counting statistics, matrix and source distribution, calibration inaccuracy, background effects, and neutron multiplication error. While a minor component for low plutonium masses, neutron multiplication error is often the major contributor to the TMU for items containing more than 140 g of weapons grade plutonium. Neutron multiplication arises when neutrons from spontaneous fission and other nuclear events induce fissions in other fissile isotopes in the waste, thereby multiplying the overall coincidence neutron response in passive neutron measurements. Since passive neutron counters cannot differentiate between spontaneous and induced fission neutrons, multiplication can lead to positive bias in the measurements. Although neutron multiplication can only result in a positive bias, it has, for the purpose of mathematical simplicity, generally been treated as an error that can lead to either a positive or negative result in the TMU. While the factors that contribute to neutron multiplication include the total mass of fissile nuclides, the presence of moderating material in the matrix, the concentration and geometry of the fissile sources, and other factors; measurement uncertainty is generally determined as a function of the fissile mass in most TMU software calculations because this is the only quantity determined by the passive neutron measurement. Neutron multiplication error has a particularly pernicious consequence for TRU waste analysis because the measured Fissile Gram Equivalent (FGE) plus twice the TMU error must be less than 200 for TRU waste packaged in 55-gal drums and less than 325 for boxed waste. For this reason, large errors due to neutron multiplication can lead to increased rejections of TRU waste containers. This report will attempt to better define the error term due to neutron multiplication and arrive at values that are more realistic and accurate. To do so, measurements of standards and waste drums were performed with High Efficiency Neutron Counters (HENC) located at Los Alamos National Laboratory (LANL). The data were analyzed for multiplication effects and new estimates of the multiplication error were computed. A concluding section will present alternatives for reducing the number of rejections of TRU waste containers due to neutron multiplication error.
Uterine leiomyomas are benign myometrial neoplasms that function as one of the common indications for hysterectomy. Clinical and biological evidences indicate that uterine leiomyomas are estrogen-dependent. Estrogen stimulates cell proliferation through binding to the estrogen receptor (ER), of which both subtypes α and β are present in leiomyomas. Clinically, leiomyomas may be singular or multiple, where the first one is rarely recurring if removed and the latter associated to a relatively young age or genetic predisposition. These markedly different clinical phenotypes indicate that there may different mechanism causing a similar smooth muscle response. To investigate the relative expression of ERα and ERβ in multiple and solitary uterine leiomyomas, we collected samples from 35 Chinese women (multiple leiomyomas n = 20, solitary leiomyoma n = 15) undergoing surgery to remove uterine leiomyomas. ELISA assay was performed to detect estrogen(E{sub 2}) concentration. Quantitative real-time PCR analysis was performed to detect ERα and ERβ mRNA expression. Western blot and immunohistochemical analysis were performed to detect ERα and ERβ protein expression. We found that ERα mRNA and protein levels of in multiple leiomyomas were significantly lower than those of solitary leiomyomas, whereas ERβ mRNA and protein levels in multiple leiomyomas were significantly higher than those in solitary leiomyomas, irrespectively of the menstrual cycle stage. In both multiple and solitary leiomyomas, ERα expression was higher than that of ERβ. E{sub 2} concentration in multiple and solitary leiomyomas correlated with that of ERα expression. ERα was present in nuclus and cytoplasma while estrogen receptor β localized only in nuclei in both multiple and solitary leiomyomas. Our findings suggest that the difference of ERα and ERβ expression between multiple and solitary leiomyomas may be responsible for the course of the disease subtypes. - Highlights: • In both multiple and solitary leiomyomas, ERα expression was higher than that of ERβ. • ERα was significantly lower, whereas ERβ was significantly higher in multiple leiomyomas than that in solitary leiomyomas. • The differential expression of ERα and ERβ may be responsible for the cause of the disease subtypes.
A diffractive optic element (DOE) can be used as a beam splitter to generate multiple laser beams from a single input laser beam. This technology has been recently used in LRO s Lunar Orbiter Laser Altimeter (LOLA) instrument to generate five laser beams that measure the lunar topography from a 50-km nominal mapping orbit (see figure). An extension of this approach is to use a multiple-zone DOE to allow a laser altimeter instrument to operate over a wider range of distances. In particular, a multiple-zone DOE could be used for applications that require both mapping and landing on a planetary body. In this case, the laser altimeter operating range would need to extend from several hundred kilometers down to a few meters. The innovator was recently involved in an investigation how to modify the LOLA instrument for the OSIRIS asteroid mapping and sample return mission. One approach is to replace the DOE in the LOLA laser beam expander assembly with a multiple-zone DOE that would allow for the simultaneous illumination of the asteroid with mapping and landing laser beams. The proposed OSIRIS multiple-zone DOE would generate the same LOLA five-beam output pattern for high-altitude topographic mapping, but would simultaneously generate a wide divergence angle beam using a small portion of the total laser energy for the approach and landing portion of the mission. Only a few percent of the total laser energy is required for approach and landing operations as the return signal increases as the inverse square of the ranging height. A wide divergence beam could be implemented by making the center of the DOE a diffractive or refractive negative lens. The beam energy and beam divergence characteristics of a multiple-zone DOE could be easily tailored to meet the requirements of other missions that require laser ranging data. Current single-zone DOE lithographic manufacturing techniques could also be used to fabricate a multiple-zone DOE by masking the different DOE zones during the manufacturing process, and the same space-compatible DOE substrates (fused silica, sapphire) that are used on standard DOE s could be used for multiple- zone DOE s. DOEs are an elegant and cost-effective optical design option for spacebased laser altimeters that require multiple output laser beams. The use of multiple-zone DOEs would allow for the design and optimization of a laser altimeter instrument required to operate over a large range of target distances, such as those designed to both map and land on a planetary body. In addition to space-based laser altimeters, this technology could find applications in military or commercial unmanned aerial vehicles (UAVs) that fly at an altitude of several kilometers and need to land. It is also conceivable that variations of this approach could be used in land-based applications such as collision avoidance and robotic control of cars, trains, and ships.
We image 104 newly identified low-mass (mostly M-dwarf) pre-main sequence (PMS) members of nearby young moving groups (YMGs) with Magellan Adaptive Optics (MagAO) and identify 27 stellar binaries with instantaneous projected separation as small as 40 mas. Fifteen were previously unknown. The total number of multiple systems in this sample including spectroscopic and visual binaries from the literature is 36, giving a raw stellar multiplicity rate of at least 35{sub −4}{sup +5}% for this population. In the separation range of roughly 1–300 au in which infrared AO imaging is most sensitive, the raw multiplicity rate is at least 24{sub −4}{sup +5}% for binaries resolved by the MagAO infrared camera (Clio). The M-star subsample of 87 stars yields a raw multiplicity of at least 30{sub −4}{sup +5}% over all separations, 21{sub −4}{sup +5}% for secondary companions resolved by Clio from 1 to 300 au (23{sub −4}{sup +5}% for all known binaries in this separation range). A combined analysis with binaries discovered by the Search for Associations Containing Young stars shows that stellar multiplicity fraction as a function of mass over the range of 0.2 to 1.2 M {sub ☉} appears to be linearly flat, in contrast to the field, where multiplicity increases with mass. After bias corrections are applied, the multiplicity of low-mass YMG members (0.2–0.6 M {sub ☉}) is in excess of the field. The overall multiplicity fraction is also consistent with being constant in age and across YMGs, which suggests that multiplicity rates for this mass range are largely set by 10 Myr without appreciable evolution thereafter.