Search NASA⌕ Search

SEARCH · Search NASA

Results for “MULTIPLIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Multiplying Mars Lander Opportunities with Marsdrop Microlanders

From canyons to glaciers, from geology to astrobiology, the amount of exciting surface science awaiting us at Mars greatly outstrips available mission opportunities. Based on the thrice -flown Aerospace Corporation Earth Reentry Breakup Recorder (REBR), we present a method for accurate landing of small instrument payloads on Mars, utilizing excess cruise -stage mass on larger missions. One to a few such microlanders might add 1-5% to the cost of a primary mission with inconsequential risk. Using the REBR and JPL Deep Space 2 starting points for a passively stable entry vehicle provides a low mass and low ballistic coefficient, enabling subsonic d employment of a steerable parawing glider, capable of 10+ km of guided flight at a 3:1 glide ratio. Originally developed for the Gemini human space program, the parawing is attractive for a volume -limited microprobe, minimizing descent velocity, and providing sufficient remaining volume for a useful scientific payload. The ability to steer the parawing during descent opens unique opportunities, including terrain- relative navigation for landing within tens of meters of one of several specified targets within a given uncertainty ellipse. In addition to scientific value, some Mars human exploration Strategic Knowledge Gaps could be addressed with deployment of focused instruments at multiple locations.

Staehle, Robert L.↗

High Power W-Band/F-Band Schottky Diode Based Frequency Multipliers

A solid state device chip including diodes (generating a higher frequency output through frequency multiplication of the input frequency) and a novel on-chip power combining design. Together with the on-chip power combining, the chip has increased efficiency because the diodes' anodes, being micro-fabricated simultaneously on the same patch of a GaAs wafer under identical conditions, are very well balanced. The diodes' GaAs heterostructure and the overall chip geometry are designed to be optimized for high power operation. As a result of all these features, the device can generate record-setting power having a signal frequency in the F-band and W-band (30% conversion efficiency).

Siles Perez, Jose Vicente↗

Genesis Noble Gas Measurements

The original thrust of our Genesis funding was to extend and refine the noble gas analytical capabilities of this laboratory to improve the precision and accuracy of noble gas measurements in order to optimize the scientific return from the Genesis Mission. This process involved both instrumental improvement (supplemented by a SRLIDAP instrument grant) and refinement of technique. The Genesis landing mishap shifted our emphasis to the irregular aluminum heat shield material from the flat collector wafers. This has required redesign of our laser extraction cells to accommodate the longer focal lengths required for laser extraction from non-flat surfaces. Extraction of noble gases from solid aluminum surfaces, rather than thin coatings on transparent substrates has required refinement of controlled-depth laser ablation techniques. Both of these bring new problems, both with potentially higher blanks form larger laser cells and the larger quantities of evaporated aluminum which can coat the sapphire entrance ports. This is mainly a problem for the heavy noble gases where larger extraction areas are required, necessitating the new aluminum vapor containment techniques described below. With the Genesis Mission came three new multiple multiplier noble gas mass spectrometers to this laboratory, one built solely by us (Supergnome-M), one built in collaboration with Nu-Instruments (Noblesse), and one built in collaboration with GVI (Helix). All of these have multiple multiplier detection sections with the Nu-Instruments using a pair of electrostatic quad lenses for isotope spacing and the other two using mechanically adjustable positions for the electron multipliers. The Supergnome-M and Noblesse are installed and running. The GVI instrument was delivered a year late (in March 2005) and is yet to be installed by GVI. As with all new instruments there were some initial development issues, some of which are still outstanding. The most serious of these are performance issues with the miniature channel electron multipliers. The delayed installation of Helix by the GVI is partly due to failure of the initial batch of Burle channel multipliers to perform as expected. A number of the channel multipliers designed for Noblesse by Burle have also failed upon baking. Burle has now refined the design of these and we have installed two of the new multipliers and are assessing their performance. The remaining multipliers Will be upgraded to the new design from Burle once we confirm that the problem has been fixed.

Hohenberg, Charles M.↗

TRAILS Output Files

Overview This data repository contains ZIP files that store compressed versions of the output of running the WaterPaths utility planning and management tool in the DU Re-Evaluation mode (to download the tool, please see this GitHub repository). The tool was used to simulate the six-utility North Carolina Research Triangle problem. Details on the contents of each ZIP file can be seen below. Data details Temporal range: Weekly data for 2,344 weeks from 2015 to 2060 (45 years). Spatial range: Six water utilities in the North Carolina Research Triangle region (0: Chapel Hil/OWASA, 1: Durham, 2: Cary, 3: Raleigh, 4: Pittsboro, and 5: Chatham) File types: CSV and OUT Different solutions available The solution numbers correspond to the different pathway strategies (henceforth referred to as "solutions") discussed in paper's main and supporting text (abstract and link to the paper here). They are as follows: Sol92: The Durham-focused pathway strategy Sol132: The Raleigh-focused pathway strategy Sol140: The regionally-robust pathway strategy Objectives files These files can be accessed by unzipping solXX_objectives_pathways.zip that contains 1,000 Objectives_RDMXX_solsXX_to_XX.csv files. Each CSV file will consist of a row representing all the objective values for that specific solution, while every six columns represents the reliability, restriction frequency, infrastructure net present value ($ mil), peak financial cost, worst-case cost, and unit cost ($ per MG; in that order) for each of the six utilities. There will be 1,000 such files, denoting the performance of the six utilities across the 1,000 deeply uncertain states of the world (DU SOWs). Pathway files These files can be accessed by unzipping solXX_objectives_pathways.zip that contains 1,000 Pathways_sXX_RDMXX.out file. Each OUT corresponds to the set of infrastructure being triggered in a specific DU SOW, and each file will have the name file will consist of four tab-delimited columns that are described as follows: Realization: The realization in which an infrastructure options being triggered utility: The utility currently triggering infrastructure week: The week in which a specific infrastructure option is being triggered infra.: The infrastructure option being triggered If the OUT file contains only the header line, no infrastructure was triggered for that specific DU SOW. Policies files These files can be obtained by unzipping Policies.zip. Each of the 1,000 CSV files within the unzipped folder will contain weekly water use restriction policies for all 1,000 hydroclimatic realizations within a specific DU SOW. The column structure is as follows: 0rest_m: restriction multiplier for utility 0 (values between 0 and 1) 1rest_m: restriction multiplier for utility 1 (values between 0 and 1) 2rest_m: restriction multiplier for utility 2 (values between 0 and 1) 3rest_m: restriction multiplier for utility 3 (values between 0 and 1) 4rest_m: restriction multiplier for utility 4 (values between 0 and 1) 5rest_m: restriction multiplier for utility 5 (values between 0 and 1) 0transf: transfer volume for utility 0 (in MGD) 1transf: transfer volume for utility 1 (in MGD) 2transf: transfer volume for utility 2 (in MGD) 3transf: transfer volume for utility 3 (in MGD) 4transf: transfer volume for utility 4 (in MGD) 5transf: transfer volume for utility 5 (in MGD) Water Sources files These files can be obtained by unzipping WaterSources_subset.zip. Each of the 100 CSV files within the unzipped folder will contain weekly state variables at each water source for all 1,000 hydroclimatic realizations within a specific DU SOW. The column structure is as follows: Xvolume: available water volume from source X (in MGD) Xs_area: surface area of source X (in ACF) Xdemand: demand drawn from a water source from source X (in MGD) Xup_spill: upstream spillage from source X (in MGD) Xww_inflow: wastewater inflow from source X (in MGD) Xcatch_inflow: upstream catchment inflow to source X (in MGD) Xevap: evaporation multiplier for source X (values between 0 and 1) Xds_spill: downstream spillage from source X (in MGD) X_Y_alloc_cap: the allocated capacity from source X to utility Y (values between 0 and 1) X_Y_alloc_dem: the allocated demand from source X to utility Y (values between 0 and 1) Xtrmt_alloc_Y: the allocated treatment capacity from source X to utility Y (values between 0 and 1) Utilities files These files can be obtained by unzipping Utilities_subset.zip. Each of the 100 CSV files within the unzipped folder will contain weekly state variables at each utility for all 1,000 hydroclimatic realizations within a specific DU SOW. The column structure is as follows: Xst_vol: total available storage volume of utility X (in MG) Xcapacity: total storage capacity of utility X (in MG) Xnet_inf: : net inflow for all storage infrastructure for utility X (in MGD) Xst_rof: short term ROF for utility X (values between 0 and 1) Xst_stor_rof: short-term storage ROF for utility X (values between 0 and 1) Xst_trmt_rof: short-term treatment ROF for utility X (values between 0 and 1) Xlt_rof: long-term ROF for utility X (values between 0 and 1) Xlt_stor_rof: long-term storage ROF for utility X (values between 0 and 1) Xlt_trmt_rof: long-term treatment ROF for utility X (values between 0 and 1) Xrest_demand: restricted demand for utility X (in MGD) Xunrest_demand: unrestricted demand for utility X (in MGD) Xunfulf_demand: unfulfilled demand for utility X (in MGD) Xwastewater: wastewater return for utility X (in MGD) Xtreat_capacity: total treatment capacity for utility X (in MG) Xcont_fund: reserve (contingency) fund balance for utility X Xins_pout: insurance payout for utility X (% annual volumetric revenue) Xins_price: insurance price for utility X (% annual volumetric revenue) Xinfra_npv: infrastructure net present value for utility ($mil) Xst_vol: total available storage volume of utility X (in MG) Xdebt_serv: debt service for utility X (usually once per year if the infrastructure is triggered; % annual volumetric revenue) Xstor_vol: total stored volume (in MGD) Xobs_ann_dem: observed annual demand for utility X (in MGD) Xproj_dem: projected annual demand for utility X (in MGD) Xpv_debt_serv: present value of debt service payments for utility X (% annual volumetric revenue) Xgross_rev: gross revenue for utility X ($mil) Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program.

Artificial Intelligence↗

The Newton Modified Barrier Method for QP Problems

The Modified Barrier Functions (MBF) have elements of both Classical Lagrangians (CL) and Classical Barrier Functions (CBF). The MBF methods find an unconstrained minimizer of some smooth barrier function in primal space and then update the Lagrange multipliers, while the barrier parameter either remains fixed or can be updated at each step. The numerical realization of the MBF method leads to the Newton MBF method, where the primal minimizer is found by using Newton's method. This minimizer is then used to update the Lagrange multipliers. In this paper, we examine the Newton MBF method for the Quadratic Programming (QP) problem. It will be shown that under standard second-order optimality conditions, there is a ball around the primal solution and a cut cone in the dual space such that for a set of Lagrange multipliers in this cut cone, the method converges quadratically to the primal minimizer from any point in the aforementioned ball, and continues to do so after each Lagrange multiplier update. The Lagrange multipliers remain within the cut cone and converge linearly to their optimal values. Any point in this ball will be called a "hot start". Starting at such a "hot start", at most Omicron(1n 1n epsilon(exp -1)) Newton steps are sufficient to perform the primal minimization which is necessary for the Lagrange multiplier update. Here, epsilon > 0 is the desired accuracy. Because of the linear convergence of the Lagrange multipliers, this means that only Omicron(1n epsilon(exp -1))omicron(ln 1n epsilon(exp-1)) Newton steps are required to reach an epsilon-approximation to the solution from any "hot start". In order to reach the "hot start", one has to perform Omicron(square root(m) 1n C) Newton steps, where m characterizes the size of the problem and C > 0 is the condition number of the QP problem. This condition number will be characterized explicitly in terms of key parameters of the QP problem, which in turn depend on the input data and the size of the problem.

Melman, A.↗

Phase control circuits using frequency multiplications for phased array antennas

A phase control coupling circuit for use with a phased array antenna is described. The coupling circuit includes a combining circuit which is coupled to a transmission line, a frequency multiplier circuit which is coupled to the combining circuit, and a recombining circuit which is coupled between the frequency multiplier circuit and phased array antenna elements. In a doubler embodiment, the frequency multiplier circuit comprises frequency doublers and the combining and recombining circuits comprise four-port hybrid power dividers. In a generalized embodiment, the multiplier circuit comprises frequency multiplier elements which multiply to the Nth power, the combining circuit comprises four-part hybrid power dividers, and the recombinding circuit comprises summing circuits.

Mailloux, R. J.↗

Large array VLSI filter

A 35 by 35 element pipelined convolutional kernel is being fabricated using VLSI chips, each containing a 5 by 1 segment of the kernel. Three levels of printed circuitry are used: the first level is used for the VLSI chips, the second level connects seven chips together on one platform, and the third level connects seven platforms with associated delay lines, all fitting on one board. Therefore, on each board there are seven rows of the kernel containing 245 multipliers and adders, and five such boards complete the kernel array. Each multiplier accepts an 8 bit picture element which is multiplied by a 16 bit weight. A truncated 22 bit product is added to a previously stored product sum and the results are shifted to the following multiplier as the next picture element is read in. The multiplier uses a modified Booth algorithm to reduce the number of shift add operations nearly in half. The filter box is presently configured as an ancillary box to a VAX 11/780, but can be connected to essentially any CPU. The I/O bandwidth is easily compatible with most CPU devices.

Nathan, R.↗

Modified Interior Distance Functions (Theory and Methods)

In this paper we introduced and developed the theory of Modified Interior Distance Functions (MIDF's). The MIDF is a Classical Lagrangian (CL) for a constrained optimization problem which is equivalent to the initial one and can be obtained from the latter by monotone transformation both the objective function and constraints. In contrast to the Interior Distance Functions (IDF's), which played a fundamental role in Interior Point Methods (IPM's), the MIDF's are defined on an extended feasible set and along with center, have two extra tools, which control the computational process: the barrier parameter and the vector of Lagrange multipliers. The extra tools allow to attach to the MEDF's very important properties of Augmented Lagrangeans. One can consider the MIDFs as Interior Augmented Lagrangeans. It makes MIDF's similar in spirit to Modified Barrier Functions (MBF's), although there is a fundamental difference between them both in theory and methods. Based on MIDF's theory, Modified Center Methods (MCM's) have been developed and analyzed. The MCM's find an unconstrained minimizer in primal space and update the Lagrange multipliers, while both the center and the barrier parameter can be fixed or updated at each step. The MCM's convergence was investigated, and their rate of convergence was estimated. The extension of the feasible set and the special role of the Lagrange multipliers allow to develop MCM's, which produce, in case of nondegenerate constrained optimization, a primal and dual sequences that converge to the primal-dual solutions with linear rate, even when both the center and the barrier parameter are fixed. Moreover, every Lagrange multipliers update shrinks the distance to the primal dual solution by a factor 0 less than gamma less than 1 which can be made as small as one wants by choosing a fixed interior point as a 'center' and a fixed but large enough barrier parameter. The numericai realization of MCM leads to the Newton MCM (NMCM). The approximation for the primal minimizer one finds by Newton Method followed by the Lagrange multipliers update. Due to the MCM convergence, when both the center and the barrier parameter are fixed, the condition of the MDF Hessism and the neighborhood of the primal ninimizer where Newton method is 'well' defined remains stable. It contributes to both the complexity and the numerical stability of the NMCM.

Polyak, Roman A.↗

Perceptually-Based Adaptive JPEG Coding

An extension to the JPEG standard (ISO/IEC DIS 10918-3) allows spatial adaptive coding of still images. As with baseline JPEG coding, one quantization matrix applies to an entire image channel, but in addition the user may specify a multiplier for each 8 x 8 block, which multiplies the quantization matrix, yielding the new matrix for the block. MPEG 1 and 2 use much the same scheme, except there the multiplier changes only on macroblock boundaries. We propose a method for perceptual optimization of the set of multipliers. We compute the perceptual error for each block based upon DCT quantization error adjusted according to contrast sensitivity, light adaptation, and contrast masking, and pick the set of multipliers which yield maximally flat perceptual error over the blocks of the image. We investigate the bitrate savings due to this adaptive coding scheme and the relative importance of the different sorts of masking on adaptive coding.

Watson, Andrew B.↗

Exercise Thermoregulation Following 13 Days of Bed Rest

This investigation examined two potential mechanisms, altered skin blood flow (SBF) and sweating rate (SR) responses, that may be responsible for an elevated core temperature during exercise after bed rest (BR) and space flight. Seven healthy men (29 +/- 5 yr, 179.6 +/- 7.1 cm, 77.2 +/- 17.0kg; mean +/- SD) underwent 13 days of 6 deg head-down BR. Pre- and post-BR, subjects completed supine submaximal cycle ergometry (20 min at 40% and 20 min at 65% of pre-BR supine VO2pk) in a thermoneutral room (23.4 +/- 0.5 C, 56 +/- 8 %RH) during, heat production (VO2 ; indirect calorimetry), intestinal temperature (T(sub in) ; ingestible pill), SBF (laser Doppler velocimetry), local SR (dew point hygrometry), and total sweat loss (TSL; Delta body weight) were measured. Pre- and post- BR plasma volume (PV) was measured using I-125 dilution. After BR, T(sub in) was elevated at rest (36.99 +/- 0.14 vs. 37.30 +/- 0.06 C; p<_0.05) and at the end of exercise (37.57 +/- 0.13 vs. 37.90 +/- 0.09 C; P less than or equal to 0.05). However, the increase in T(sub in) from rest to the end of exercise was not different after BR (0.59 +/- 0.07 vs. 0.60 +/- 0.07 C). There was no difference in VO2 pre- to post-BR during rest (0.28 +/- 0.04 vs. 0.24 +/- 0.03 1 multiplied by min(exp -1) ) or 40% VO2pk (0.95 +/- 0.08 vs. 0.96 +/- 0.05 1 multiplied by min(exp -1)), but VO2 was significantly less at the end of the 65% VO2pk stage (1.53 +/- 0.09 vs. 1.42 +/- 0.11 1 multiplies by min(exp - 1); p less than or equal to 0.05). The percent change in SBF from rest to end of exercise was less after BR (211 +/- 53 vs. 96 +/- 31%; p less than or equal to 0.05), the threshold for the onset of SBF was greater (37.17 +/- 0.18vs. 37.51 +/- 0.17 C; p less than or equal to 0.05), and the slope of the response tended to be reduced (536 +/- 184 vs. 201 +/- 46 %A PC; p=0.08). TSL was not different after BR (0.42+0.06 vs. 0.44 +/- 0.08 kg), but the T in threshold at the onset of sweating was delayed significantly (37.06 +/- 0.1 1 vs. 37.34 +/- 0.06 C; p less than or equal to 0.05). However, the slope of SR was not changed after BR (3.45 +/- 1.22 vs. 2.58 +/- 0.71 mg multiplied by min(exp -1) multiplied by cm sq). PV was decreased by 11% after BR (3,259 +/- 177 vs. 2,894 +/- 138 ml; p less than or equal to 0.05). These results suggest that exercise SBF and SR responses after BR are altered, and heat production is unchanged or reduced, consistent with observations following space flight. The higher resting T(sub in) with a proportional increase in T(sub in) during exercise and delayed onset of SBF and SR suggest a centrally-mediated elevation in the thermoregulatory set point during microgravity exposure.

Lee, Stuart M. C.↗

A 2.5-2.7 THz Room Temperature Electronic Source

We report on a room temperature 2.5 to 2.7 THz electronic source based on frequency multipliers. The source utilizes a cascade of three frequency multipliers with W-band power amplifiers driving the first stage multiplier. Multiple-chip multipliers are utilized for the two initial stages to improve the power handling capability and a sub-micron anode is utilized for the final stage tripler. Room temperature measurements indicate that the source can put out a peak power of about 14 microwatts with more than 4 microwatts in the 2.5 to 2.7 THz range.

Varactor diodes↗