Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

The DREAM approach to demand-side emissions reductions in Indonesia, 2020–2060

Indonesia’s current energy system modeling is heavily focused on the supply side, but emissions reductions in the demand sector have a significant impact on advancing Indonesia’s ambitious emissions reductions goals. To address the gap, we develop a new modeling tool DREAM Indonesia based on a bottom-up, technology-rich demand side framework and formulate projections of demand-side emissions reductions in Indonesia in 2020–2060. We find that demand-side energy efficiency and electrification can halve the growth rate of final energy demand to 1.4% annually over 2020–2060 and reverse the growing trend of emissions. The feasibility of full electrification by 2060, coupled with rapid adoption of existing technologies, positions the building sector as a model for achievable decarbonization and a cornerstone of Indonesia’s emissions reductions ambitions. In the industrial sector, extensive emissions reductions of 87% by 2060 (compared to business-as-usual) are achievable through energy efficiency improvements, alongside enhanced material efficiency measures including optimized material usage, low-carbon substitutions, innovative technologies, and increased circularity. In the transportation sector, balancing final energy demand by incorporating energy efficiency improvements across all transport modes, along with electrification particularly in road transportation, could decrease the emissions by up to 82% in 2060 compared to business-as-usual. This study provides insights and modeling approaches for rapidly growing Asian economies as well as other developing countries facing combined development and decarbonization challenges.

DREAM Indonesia↗

THE SPECTRUM AND TERM ANALYSIS OF CO iii MEASURED USING FOURIER TRANSFORM AND GRATING SPECTROSCOPY

The spectrum of Co iii has been recorded in the region 1562–2564 Å (64,000 cm{sup −1}–39,000 cm{sup −1}) by Fourier transform (FT) spectroscopy, and in the region 1317–2500 Å (164,000 cm{sup −1}–40,000 cm{sup −1}) using a 10.7 m grating spectrograph with phosphor image plate detectors. The spectrum was excited in a cobalt–neon Penning discharge lamp. We classified 514 Co iii lines measured using FT spectroscopy, the strongest having wavenumber uncertainties approaching 0.004 cm{sup −1} (approximately 0.2 mÅ at 2000 Å, or 1 part in 10{sup 7}), and 240 lines measured with grating spectroscopy with uncertainties between 5 and 10 mÅ. The wavelength calibration of 790 lines of Raassen and Ortí Ortin and 87 lines from Shenstone has been revised and combined with our measurements to optimize the values of all but one of the 288 previously reported energy levels. Order of magnitude reductions in uncertainty for almost two-thirds of the 3d{sup 6}4s and almost half of the 3d{sup 6}4p revised energy levels are obtained. Ritz wavelengths have been calculated for an additional 100 forbidden lines. Eigenvector percentage compositions for the energy levels and predicted oscillator strengths have been calculated using the Cowan code.

74 ATOMIC AND MOLECULAR PHYSICS↗

Real Beamline Optics from a Synthetic Beam

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab can be described as a series of concatenated beamlines. Methods used to measure the Twiss parameters in closed orbit machines are not applicable in such open ended systems. We are using properly selected sets of real orbits in the accelerator, as one would for numerical analysis. The evolution of these trajectories along the beamline models the behavior of a synthetic beam which deterministically supplements beam profile-based Twiss parameter measurements and optimizes the efficiency of beamline tuning. Examples will be presented alongside a description of the process.

43 PARTICLE ACCELERATORS↗

Synchronization and Characterization of an Ultra-Short Laser for Photoemission and Electron-Beam Diagnostics Studies at a Radio Frequency Photoinjector

A commercially-available titanium-sapphire laser system has recently been installed at the Fermilab A0 photoinjector laboratory in support of photoemission and electron beam diagnostics studies. The laser system is synchronized to both the 1.3-GHz master oscillator and a 1-Hz signal use to trigger the radiofrequency system and instrumentation acquisition. The synchronization scheme and performance are detailed. Long-term temporal and intensity drifts are identified and actively suppressed to within 1 ps and 1.5%, respectively. Measurement and optimization of the laser's temporal profile are accomplished using frequency-resolved optical gating.

43 PARTICLE ACCELERATORS↗

Cavity Design, Fabrication and Commission Performance of a 750MHz, 4-rod Separator for CEBAF 4-Hall Beam Delivery System

A short version of the original CEBAF normal conducting 4-rod separator cavity has been developed into a 750MHz one * since the concept of simultaneous 4-hall operation for CEBAF is introduced **. This work has been advanced further based on the EM design optimization, bench measurement and by conducting RF-thermal coupled simulation using CST and ANSYS to confirm the cavity tuning and thermal performance. The cavity fabrication used matured technology like copper plating and machining. The cavity flanges, couplers, tuners and cooling channels adopted consistent/compatible hardware with the existing 500MHz cavities. The electromagnetic and thermal design simulations have greatly reduced the prototyping and bench tuning time of the first prototype. Four production cavities have reached a typical 1.94MV kick voltage or 3.0kW wall loss on each cavity after a minor multipactoring or no processing, 7.5% overhead power than the design specification.

Wang, Haipeng↗

UAS Radiological Sensing – Nevada National Security Site

In the aftermath of a hazardous incident, there is limited information and almost no means to access the area safely. There is a need to quickly obtain accurate information regarding the extent and severity of the incident. One way to quickly assess the environment is by flying over the dangerous area with unmanned aerial systems followed by remotely operated ground vehicles. The Nevada National Security Site (NNSS) provides a repeatable environment to simulate operations for dangerous and dirty situations. An unmanned aircraft system (UAS) has the advantages of fast deployment and low-altitude flying, which enhances sensitivity and wide-area coverage, eliminates radiation exposure health safety restrictions, and gives the ability to access highly hazardous or radioactive areas, etc. A UAS can be configured with the nuclear detecting sensor optimized to measure the radiation associated with the event. A multi-UAS has advantages over a single UAS, especially in time-critical tasks such as detecting nuclear radiation. UAS may be helpful in plume definition, ground deposition, moving source, and static or moving spills. Assessing any situation that is dangerous, in hazardous areas (dirty), needs to be repeated (dull), or unreachable (deep), is a candidate for an unmanned system. In addition, the NNSS is in a unique location to conduct isolated, secured, and controlled high-risk experiments. We attract international customers along with domestic agencies due to the unique environmental conditions that have evolved over the past 65 years. The NNSS employs a talented group of operational scientists and engineers with a long history of applied research in radiation/nuclear science. We often collaborate with other national laboratories and universities in addressing unique problems. The NNSS has conducted UAS missions for over 25 years and has established a UAS program to address the difficult challenges in using unmanned systems for national security missions.

42 ENGINEERING↗

The credit impact of climate change

The energy industry is bracing for a carbon-constrained world, but the ways governments choose to control carbon around the globe may have vastly different impacts on company bottom lines. The article concludes that, ultimately, any system will be effective only when it makes emissions costly. Policymakers will have to sort out several issues, primarily those pertaining to cap and trade versus a carbon tax; allocations versus auctions of credits; acceptance of global offsets, and economy-wide versus sectoral approaches. The author believes the US eventually will adopt an approach that will attempt to avoid the spectacle of coal power plants making surplus profits from emissions allowance, as has happened in Europe, while also minimizing costs to the most affected units at the program onset. In theory, this should provide these units time to deploy the most optimal abatement measures. 1 ref., 3 figs.

20 FOSSIL-FUELED POWER PLANTS↗

Recent Advancements in Tomographic Gamma Scanning for Non- Destructive Assay - 17321

Canberra Industries has recently designed and built a Tomographic Gamma Scanning (TGS) system for the deployment in a nuclear facility. The TGS technique combines high-resolution gamma spectroscopy with low spatial resolution 3- dimensional image reconstruction to provide increased accuracy over traditional approaches for the assay of non-uniform source distributions in low-to medium-density containers. The TGS system has been optimized to measure 120 liter drums and has the capability to measure containers of various sizes. Canberra has incorporated numerous enhancements and improvements to the latest system in both its hardware and software components. The signal processing chain and data analysis software have been configured to use either an electronic pulser or digital signal processing (DSP) electronics for dead time corrections. In the case of using the DSP electronics, the need to calibrate and maintain a pulser can be eliminated without sacrificing any performance. For the 120 liter container, the TGS system has been calibrated and validated with three different spatial resolutions, using two collimator aperture sizes, measuring 2.54 and 1.27 cm in width. The system has also been supplied and calibrated with a wide, rectangular collimator (25.4 cm W x 10.2 cm H) for scanning containers solely in the vertical axis. The TGS system also has an automated attenuator assembly, which has the capability to use a combination of attenuators to reduce the count rate for high activity samples. An extensive measurement campaign was performed in addition to the calibration verification to evaluate the accuracy of the system using rod sources, point sources, and a variety of matrices and source distributions. Improvements to the evaluation of the total measurement uncertainty based upon these studies have been incorporated into the analysis software package. Finally, the performance of this new TGS system will be demonstrated in the context of Canberra's previous TGS systems, including several 208 liter-based systems and a smaller, 20 liter container TGS system. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Impacts of Source Location in Tomographic Gamma Scanning - 17324

Canberra Industries has recently designed and built a Tomographic Gamma Scanning (TGS) system for the deployment in a nuclear facility. The TGS technique combines high-resolution gamma spectroscopy with low spatial resolution 3-dimensional image reconstruction to provide increased accuracy over traditional approaches for the assay of non-uniform source distributions in low-to medium-density containers. The TGS system has been optimized to measure 120 liter drums and has been equipped to use various collimators and attenuators to assay containers under a wide range of operational conditions. In this paper, we report on experimental work using TGS systems aimed at evaluating the effects of source locations at the limits of volume elements, or voxels, defined in the image reconstruction. These include sources placed at voxel boundaries within a single vertical layer and sources placed in the lowest and highest possible vertical positions within the containers. Building upon previous studies, the accuracy of the TGS system was also assessed by varying the radial position of a point source within a vertical segment. The robustness of the TGS image reconstruction algorithm to location of the sources location was also analyzed as a function of matrix density and gamma-ray energy. Methods to reduce the biases from source location at extreme positions within the container were implemented and tested. The results from this work have been used to better understand the total measurement uncertainty (TMU) and analysis methodology used in TGS systems currently deployed and under development. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flow Boiling Pressure Drop Characteristics of Next-generation Refrigerants in a Micro‑fin Copper Tube

This paper presents experimental frictional pressure-drop data for flow boiling of R-410A, R-134a, and next-generation alternatives R-454C, R-455A, R-1234yf, and R-1234ze(E) in a horizontal micro-fin copper tube. Tests were conducted over a range of mass fluxes and evaporation temperatures to characterize refrigerant-dependent two-phase pressure-drop behavior. The results show that frictional pressure gradient increased with mass flux and vapor quality and generally increased as evaporation temperature decreased, with liquid viscosity strongly affecting the observed trends. Among the evaluated correlations, the Goto et al. (2001) model gave the best overall agreement with the measurements before optimization. Further optimization of the Kuo and Wang (1996) and Goto et al. (2001) models reduced the overall mean absolute deviation to below 15%, with the optimized Goto (2001) model providing the most consistent predictions across all six refrigerants. The results support improved pressure-drop prediction and evaporator design for next-generation refrigerants in micro-fin tubes.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Transverse centroid oscillations in solenoidially focused beam transport lattices

Linear equations of motion are derived that describe small-amplitude centroid oscillations induced by displacement and rotational misalignments of the focusing solenoids in the transport lattice, dipole steering elements, and initial centroid offset errors. These equations are analyzed in a local rotating Larmor frame to derive complex-variable"alignment functions" and"bending functions" that efficiently describe the characteristics of the centroid oscillations induced by mechanical misalignments of the solenoids and dipole steering elements. The alignment and bending functions depend only on properties of the ideal lattice in the absence of errors and steering and have associated expansion amplitudes set by the misalignments and steering fields. Applications of this formulation are presented for statistical analysis of centroid deviations, calculation of actual lattice misalignments from centroid measurements, and optimal beam steering.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Level-1 Trigger and DAQ system of the GlueX experiment

he goal of the GlueX detector at Jefferson Lab is to study fundamental questions of the quantum chromodynamics, i.e., the nature of confinement of gluons and quarks. The detector's design is optimized to measure the spectrum of exotic mesons that are expected to be produced in interactions of 8.4 - 9.0 GeV linearly polarized photons with a liquid hydrogen target. The GlueX trigger and DAQ electronics is based on pipelined TDC boards and FADC boards running at a 250 MHz clock. The trigger logic is implemented on special purpose programmable electronics boards with Field-Programmable Gate Array chips. Two types of boards are used: Crate Trigger Processors and Global Trigger Processors. All trigger electronics is hosted in VXS crates. The Level-1 trigger should reduce the 200 MHz electromagnetic rate and the 400 kHz hadronic rate to 200 kHz total rate. The trigger algorithm makes use of a measurement of the energy deposition in two electromagnetic calorimeters and hit counts in

08 HYDROGEN↗

Transverse Centroid Oscillations in Solenoidially Focused Beam Transport Lattices

Linear equations of motion are derived that describe small-amplitude centroid oscillations induced by displacement and rotational misalignments of the focusing solenoids in the transport lattice, dipole steering elements, and initial centroid offset errors. These equations are analyzed in a local rotating Larmor frame to derive complex-variable 'alignment functions' and 'bending functions' that efficiently describe the characteristics of the centroid oscillations induced by mechanical misalignments of the solenoids and dipole steering elements. The alignment and bending functions depend only on properties of the ideal lattice in the absence of errors and steering and have associated expansion amplitudes set by the misalignments and steering fields. Applications of this formulation are presented for statistical analysis of centroid deviations, calculation of actual lattice misalignments from centroid measurements, and optimal beam steering.

43 PARTICLE ACCELERATORS↗

SPTpol: an instrument for CMB polarization.

SPTpol will consist of an 850 element polarization sensitive bolometric camera deployed to the South Pole Telescope in late 2011. This camera is optimized for measurement of the polarization of the cosmic microwave background with arcminute resolution. These measurements will be used to constrain neutrino masses and to constrain the amplitude of gravitational waves from inflation. The camera includes two detector architectures that observe in two different frequency bands. At 150 GHz, SPTpol will use 650 feedhorn-coupled TES polarimeters fabricated at NIST. At 90 GHz, it will use 200 absorber-coupled polarimeters developed at Argonne National Lab. The NIST pixels will be coupled to the telescope using a monolithic array of corrugated feeds and the Argonne devices will be coupled with individually machined contoured feeds. The entire focal plane will be readout using a digital frequency-domain multiplexer system. We provide an overview of the project, describe the detectors and discuss the design of this system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Steam distribution and energy delivery optimization using wireless sensors

The Extreme Measurement Communications Center at Oak Ridge National Laboratory (ORNL) explores the deployment of a wireless sensor system with a real-time measurement-based energy efficiency optimization framework in the ORNL campus. With particular focus on the 12-mile long steam distribution network in our campus, we propose an integrated system-level approach to optimize the energy delivery within the steam distribution system. We address the goal of achieving significant energy-saving in steam lines by monitoring and acting on leaking steam valves/traps. Our approach leverages an integrated wireless sensor and real-time monitoring capabilities. We make assessments on the real-time status of the distribution system by mounting acoustic sensors on the steam pipes/traps/valves and observe the state measurements of these sensors. Our assessments are based on analysis of the wireless sensor measurements. We describe Fourier-spectrum based algorithms that interpret acoustic vibration sensor data to characterize flows and classify the steam system status. We are able to present the sensor readings, steam flow, steam trap status and the assessed alerts as an interactive overlay within a web-based Google Earth geographic platform that enables decision makers to take remedial action. We believe our demonstration serves as an instantiation of a platform that extends implementation to include newer modalities to manage water flow, sewage and energy consumption.

54 ENVIRONMENTAL SCIENCES↗

Optimal tuning and calibration of bendable mirrors with slope measuring profilers

We describe a technique to optimally tune and calibrate bendable x-ray optics for sub-micron focusing. The focusing is divided between two elliptically cylindrical reflecting elements, a Kirkpatrick-Baez (KB) pair. Each optic is shaped by applying unequal bending couples to each end of a flat mirror. The developed technique allowsoptimal tuning of these systems using surface slope data obtained with a slope measuring instrument, the long trace profiler (LTP). Due to the near linearity of the problem, the minimal set of data necessary for the tuning of each bender, consists of only three slope traces measured before and after a single adjustment of each bending couple. The data are analyzed with software realizing a method of regression analysis with experimentally found characteristic functions of the benders. The resulting approximation to the functional dependence of the desired shape provides nearly final settings. Moreover, the characteristic functions of the benders found in the course of tuning, can be used for retuning to a new desired shape without removal from the beamline and re-measuring. We perform a ray trace, using profiler data for the finally tuned optics, predicting the performance to be expected during use of the optics on the beamline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uncertainty as a Function of Time for Subcritical Experiment Parameters Using the Hage-Cifarelli Formalism

When designing critical or subcritical experiments, it is desirable to have an estimate of the measurement uncertainties prior to performing an experiment. In addition, an important goal is to have the smallest measurement uncertainties possible given measurement time constraints. Having well-designed experiments with small uncertainties helps improve nuclear data and therefore has direct impacts on criticality safety. This work shows how the uncertainties in various measurement parameters vary as a function of counting time and provides an approach to estimate measured uncertainties and guides in optimizing the available counting time. The uncertainty in six parameters used in subcritical experiments was investigated as a function of time: singles count rate (R{sub 1}), doubles count rate (R{sub 2}), lifetime (1/λ), leakage multiplication (M{sub L}), spontaneous fission rate (FS), and detector efficiency (ε). A comparison to measured data will be presented at the meeting. The approach and results in this work will be used to optimize measurement time in future subcritical experiments and will be used to help estimate measurement uncertainties during the design phase. Having well-designed experiments with the smallest uncertainties possible can help the criticality safety community through data validation. (authors)

42 ENGINEERING↗