Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mechanical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Michelson interferometer with separated inputs and outputs, double pass, and compensation

A novel configuration is proposed for a Michelson interferometer spectrometer, which will be insensitive to tilts or displacements, and which employs separated inputs and outputs and double passing for higher resolution. The great advantage of such a compensated design is a relaxation of mechanical tolerances, which is especially beneficial for instruments in hostile environments. The Atmospheric Trace Molecule Spectroscopy project, which must work reliably after being subjected to the vibrations of a Space Shuttle launch, would benefit from the use of such an instrument.

Mather, J. C.↗

Turbomachinery technology for high-speed civil flight

NASA Lewis' research and technology efforts applicable to turbomachinery for high-speed flight are discussed. The potential benefits and cycle requirements for advanced variable cycle engines and the supersonic throughflow fan engine for a high-speed civil transport application are presented. The supersonic throughflow fan technology program is discussed. Technology efforts in the basic discipline areas addressing the severe operating conditions associated with high-speed flight turbomachinery are reviewed. Included are examples of work in internal fluid mechanics, high-temperature materials, structural analysis, instrumentation and controls.

Saunders, Neal T.↗

Modeling of internal contaminant deposition on a cold instrument sensor

A model is developed to predict the deposition of contaminants on the CCD sensors of the Wide Field Planetary Camera to determine expected performance parameters. Contaminant deposition due to internal instrument sources is considered as is the mechanism of transport to the CCDs themselves. The Contamination Analysis Program (CAP) model considers deposition and reemission kinetics, nodal containment sources, and internodal shape factors related to line-of-sight transport. Indirect transport is also accounted for in the CAP model by considering the effect of diffuse reflection at internodal exchanges. The effective total transport factors for each node-to-node exchange is precalculated to reduce the effective number of nodes and reducing run time of the CAP program. The method is applied to four distinct conditions and is found to be suitable for the analysis of internal self-contamination. Cold traps, venting, and vacuumlike design are factors which are found to be important for cold-sensitive sensors.

Barengoltz, Jack B.↗

Design of a fast computer-based partial discharge diagnostic system

Partial discharges cause progressive deterioration of insulating materials working in high voltage conditions and may lead ultimately to insulator failure. Experimental findings indicate that deterioration increases with the number of discharges and is consequently proportional to the magnitude and frequency of the applied voltage. In order to obtain a better understanding of the mechanisms of deterioration produced by partial discharges, instrumentation capable of individual pulse resolution is required. A new computer-based partial discharge detection system was designed and constructed to conduct long duration tests on sample capacitors. This system is capable of recording large number of pulses without dead time and producing valuable information related to amplitude, polarity, and charge content of the discharges. The operation of the system is automatic and no human supervision is required during the testing stage. Ceramic capacitors were tested at high voltage in long duration tests. The obtained results indicated that the charge content of partial discharges shift towards high levels of charge as the level of deterioration in the capacitor increases.

Oliva, Jose R.↗

A three dimensional radiative transfer method for optical remote sensing of vegetated land surfaces

In the application of remote sensing at optical wavelengths to vegetated surfaces from satellite borne high resolution instruments, an understanding of the various physical mechanisms that contribute to the measured signal is important. A numerical method of solving the radiative transfer equation in three dimensions is reported. The reliability of coding and accuracy of the algorithm are evaluated by benchmarching. Parametrization of the methods and results of a simulation are presented. The method is tested with experimental data of canopy bidirectional reflectance factors. The effect of spatial heterogeneity on the relationship between the simple ratio and normalized vrs absorbed Photosynthetically Active Radiation (PAR) is discussed.

Asrar, Ghassem↗

Advanced packaging for Integrated Micro-Instruments

The relationship between packaging, microelectronics, and micro-electrical-mechanical systems (MEMS) is an important one, particularly when the edges of performance boundaries are pressed, as in the case of miniaturized systems. Packaging is a sort of physical backbone that enables the maximum performance of these systems to be realized, and the penalties imposed by conventional packing approaches is particularly limiting for MEMS devices. As such, advanced packaging approaches, such as multi-chip modules (MCM's) have been touted as a true means of electronic 'enablement' for a variety of application domains. Realizing an optimum system of packaging, however, in not as simple as replacing a set of single chip packages with a substrate of interconnections. Research at Phillips Laboratory has turned up a number of integrating options in the two- and three-dimensional rending of miniature systems with physical interconnection structures with intrinsically high performance. Not only do these structures motivate the redesign of integrated circuits (IC's) for lower power, but they possess interesting features that provide a framework for the direct integration of MEMS devices. Cost remains a barrier to the application of MEMS devices, even in space systems. Several innovations are suggested that will result in lower cost and more rapid cycle time. First, the novelty of a 'constant floor plan' MCM which encapsulates a variety of commonly used components into a stockable, easily customized assembly is discussed. Next, the use of low-cost substrates is examined. The anticipated advent of ultra-high density interconnect (UHDI) is suggested as the limit argument of advanced packaging. Finally, the concept of a heterogeneous 3-D MCM system is outlined that allows for the combination of different compatible packaging approaches into a uniformly dense structure that could also include MEMS-based sensors.

Lyke, James L.↗

Enough Is Enough

The spacecraft was nearly integrated and had passed some of its early mechanical and electrical testing. One of its instruments, the Proportional Counter Array (PCA), had a gas leak in one of the five proportional counter modules that made up the array. The science division where the instrument was being developed wanted a gas replenishment system added to assure the PCA would last for the entire mission. Adding a gas replenishment system would mean interrupting spacecraft integration and testing; developing a new subsystem and integrating it onto the spacecraft; modifying all the PCA modules; including a complex integration of the instrument onto the spacecraft; and implementing a more complex performance and environmental test process. It was the wrong answer because it made a simple design more complex and added little value to the mission at a major cost in time and dollars. Our mission couldn't afford the additional budget and schedule risks. XTE was the latest of a long line of projects being managed by my Explorer Program Office, but it was unique in being the first project we had agreed to do for a fixed price. NASA HQ agreed, in return, to provide us with the funding profile we needed to make it happen. We were both trying to break the unhealthy spiral in the Explorer program that saw current missions overrunning and pushing subsequent missions downstream to the point where their science was becoming marginal. The science community was upset and wanted better performance from NASA. I summarized my arguments to the director. The Engineering Directorate had taken responsibility for the spacecraft development when we established XTE as an in-house project at Goddard Space Flight Center, and also was supporting the PCA development. "It adds complexity," I reiterated. "It's a significant cost impact for only a marginal reliability increase". His response was music to my ears, "Jim, I won't stand in your way, but you'll have to convince the scientists and engineers."

Barrowman, James↗

Phase Calibration of Microphones by Measurement in the Free-field

Over the past several years, significant effort has been expended at NASA Langley developing new Micro-Electro-Mechanical System (MEMS)-based microphone directional array instrumentation for high-frequency aeroacoustic measurements in wind tunnels. This new type of array construction solves two challenges which have limited the widespread use of large channel-count arrays, namely by providing a lower cost-per-channel and a simpler method for mounting microphones in wind tunnels and in field-deployable arrays. The current generation of array instrumentation is capable of extracting accurate noise source location and directivity on a variety of airframe components using sophisticated data reduction algorithms [1-2]. Commercially-available MEMS microphones are condenser-type devices and have some desirable characteristics when compared with conventional condenser-type microphones. The most important advantages of MEMS microphones are their size, price, and power consumption. However, the commercially-available units suffer from certain important shortcomings. Based on experiments with array prototypes, it was found that both the bandwidth and the sound pressure limit of the microphones should be increased significantly to improve the performance and flexibility of the microphone array [3]. It was also desired to modify the packaging to eliminate unwanted Helmholtz resonance s exhibited by the commercial devices. Thus, new requirements were defined as follows: Frequency response: 100 Hz to 100 KHz (+/-3dB) Upper sound pressure limit: Design 1: 130 dB SPL (THD less than 5%) Design 2: 150-160 dB SPL (THD less than 5%) Packaging: 3.73 x 6.13 x 1.3 mm can with laser-etched lid. In collaboration with Novusonic Acoustic Innovation, NASA modified a Knowles SiSonic MEMS design to meet these new requirements. Coupled with the design of the enhanced MEMS microphones was the development of a new calibration method for simultaneously obtaining the sensitivity and phase response of the devices over their entire broadband frequency range. Traditionally, electrostatic actuators (EA) have been used to characterize air-condenser microphones; however, MEMS microphones are not adaptable to the EA method due to their construction and very small diaphragm size [4]. Hence a substitution based, free-field method was developed to calibrate these microphones at frequencies up to 80 kHz. The technique relied on the use of a random, ultrasonic broadband centrifugal sound source located in a small anechoic chamber. The free-field sensitivity (voltage per unit sound pressure) was obtained using the procedure outlined in reference 4. Phase calibrations of the MEMS microphones were derived from cross spectral phase comparisons between the reference and test substitution microphones and an adjacent and invariant grazing-incidence 1/8-inch standard microphone. The free-field calibration procedure along with representative sensitivity and phase responses for the new high-frequency MEMS microphones are presented here.

Shams, Qamar A.↗

DRAGON - 8U Nanosatellite Orbital Deployer

The Space Research Centre of the Polish Academy of Sciences (SRC PAS) together with Astronika company have developed an Orbital Deployer called DRAGON for ejection of the Polish scientific nanosatellite BRITE-PL Heweliusz (Fig. 1). The device has three unique mechanisms including an adopted and scaled lock and release mechanism from the ESA Rosetta mission MUPUS instrument. This paper discusses major design restrictions of the deployer, unique design features, and lessons learned from development through testing.

Dobrowolski, Marcin↗

Laboratory Testing and Performance Verification of the CHARIS Integral Field Spectrograph

The Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) is an integral field spectrograph (IFS) that has been built for the Subaru telescope. CHARIS has two imaging modes; the high-resolution mode is R82, R69, and R82 in J, H, and K bands respectively while the low-resolution discovery mode uses a second low-resolution prism with R19 spanning 1.15-2.37 microns (J+H+K bands). The discovery mode is meant to augment the low inner working angle of the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) adaptive optics system, which feeds CHARIS a coronagraphic image. The goal is to detect and characterize brown dwarfs and hot Jovian planets down to contrasts five orders of magnitude dimmer than their parent star at an inner working angle as low as 80 milliarcseconds. CHARIS constrains spectral crosstalk through several key aspects of the optical design. Additionally, the repeatability of alignment of certain optical components is critical to the calibrations required for the data pipeline. Specifically the relative alignment of the lens let array, prism, and detector must be highly stable and repeatable between imaging modes. We report on the measured repeatability and stability of these mechanisms, measurements of spectral crosstalk in the instrument, and the propagation of these errors through the data pipeline. Another key design feature of CHARIS is the prism, which pairs Barium Fluoride with Ohara L-BBH2 high index glass. The dispersion of the prism is significantly more uniform than other glass choices, and the CHARIS prisms represent the first NIR astronomical instrument that uses L-BBH2as the high index material. This material choice was key to the utility of the discovery mode, so significant efforts were put into cryogenic characterization of the material. The final performance of the prism assemblies in their operating environment is described in detail. The spectrograph is going through final alignment, cryogenic cycling, and is being delivered to the Subaru telescope in April 2016. This paper is a report on the laboratory performance of the spectrograph, and its current status in the commissioning process so that observers will better understand the instrument capabilities. We will also discuss the lessons learned during the testing process and their impact on future high-contrast imaging spectrographs for wavefront control.

Coronagraphic High Angular Resolution Imaging Spec↗

Compact piezoelectric resonance mass balance for sample verification and mass quantification and mixing.

There is a need for sample verification and mass quantification of rock, soil and/or ice obtained by sample acquisition mechanisms on extraterrestrial bodies. For many scientific instruments information about the mass of the sample would aid in the interpretation of the data and help prevent the portioning system from overloading instrument ports. Additionally, on a potential sample return mission it is likely that a sample confirmation or mass determination requirement would be implemented before the spacecraft would be commanded to return to Earth or Lunar orbit. In an effort to meet these potential requirements, a piezoelectric resonance balance is being developed to measure a frequency change proportional to the sample mass change. In previous work1 we developed a resonance balance which produced large non-linear frequency changes due to the addition of a large mass. In this study we have looked at a variety of resonator geometries in an effort to linearize the frequency shift with mass. In addition, we have investigated the use of oscillator/counter circuitry to track the frequency shift of the piezoelectric mass balance. In this new design the frequency shifts automatically when a mass is placed on the balance and the counter circuit calculates the frequency shift. This frequency is then converted to a mass using calibration tables determined previously. An additional feature we have implemented is the use of a high frequency thickness mode piezoelectric resonator to mix the sample and a reactant or solvent. This allows for measuring both sample and reagent prior to ingestion by the instrument. This paper will focus on the design requirements and how they are affected by the local gravity and acoustic properties of the sample. Designs which allow for easy loading and unloading of the balance will also be discussed.

Yahnker, Christopher R.↗

Electromagnetic Thermocouple (TC) Anomaly Mechanisms During Atmospheric Entry

Thermocouples (TCs) are a critical diagnostic sensor for high enthalpy environments including Thermal Protection Systems (TPS) for atmospheric entry, hypersonic wind tunnels, and arc jet test facilities. They are used for both evaluating facility environmental conditions (enthalpy, and heat flux) as well as for measuring in-situ material thermal response under test conditions (thermal conductivity, heat capacity, etc.). Consequently, accurate TC measurements are fundamental for both material and facility Verification and Validation (V&V). However, a number of electromagnetic TC anomalies have been observed in both ground tests and flight instrumentations. These anomalies are caused via various coupling mechanisms: surface voltage coupling, Hall effect currents, and RF rectification. All of these mechanisms can, if unaddressed, result in obviously compromised results or worse, non-physical measurements which appear reasonable. This talk will provide an overview of each of these anomaly mechanisms and discuss ongoing efforts to quantify and mitigate them.

Magnus Haw↗

A survey of thermocouple anomalies: mechanisms, interpretation, and mitigation

Thermocouples (TCs) are a critical diagnostic sensor for high enthalpy environments including thermal protection systems (TPS) for atmospheric re-entry, hypersonic wind tunnels, and arc jet test facilities. They are used for both evaluating facility environmental conditions (enthalpy, heat flux) as well as for measuring in-situ material thermal response under test conditions (thermal conductivity, heat capacity, B’, etc.). Consequently, accurate TC measurements are fundamental for both material and facility verification and validation (V&V). However, a number of TC anomalies have been observed in both ground tests and flight instrumentation. These anomalies are caused via various coupling mechanisms: electrostatic gradients, temperature-dependent electrical shorts, radio pickup, magnetic induction, and pressure-dependent leaks. All of these mechanisms can, if unaddressed, result in obviously compromised results or worse, non-physical measurements which appear reasonable. This work will survey known anomaly mechanisms and discuss ongoing efforts to quantify and mitigate anomaly mechanisms including anomaly modeling, diagnostics, and new TC designs/development.

thermocouple anomalies↗

A Survey of Thermocouple Anomalies: Mechanisms, Interpretation, and Mitigation

Thermocouples (TCs) are a critical diagnostic sensor for high enthalpy environments including thermal protection systems (TPS) for atmospheric re-entry, hypersonic wind tunnels, and arc jet test facilities. They are used for both evaluating facility environmental conditions (enthalpy, heat flux) as well as for measuring in-situ material thermal response under test conditions (thermal conductivity, heat capacity, B’, etc.). Consequently, accurate TC measurements are fundamental for both material and facility verification and validation (V&V). However, a number of TC anomalies have been observed in both ground tests and flight instrumentation. These anomalies are caused via various coupling mechanisms: electrostatic gradients, temperature-dependent electrical shorts, radio pickup, magnetic induction, and pressure-dependent leaks. All of these mechanisms can, if unaddressed, result in obviously compromised results or worse, non-physical measurements which appear reasonable. This work will survey known anomaly mechanisms and discuss ongoing efforts to quantify and mitigate anomaly mechanisms including anomaly modeling, diagnostics, and new TC designs/development.

Thermocouple Anomalies↗

Chemistry of Martian Soils from the Mars Exploration Rover APXS Instruments

The martian surface is covered with debris formed by several mechanisms and mobilized by various processes. Volcanism, impact, physical weathering and chemical alteration combine to produce particles of sizes from dust to boulders composed of primary mineral and rock fragments, partially altered primary materials, alteration minerals and shock-modified materials from all of these. Impacts and volcanism produce localized deposits. Winds transport roughly sand-sized material over intermediate distances, while periodic dust storms deposit a global dust layer of the finest fraction. The compositions of clastic sediments can be used to evaluate regional differences in crustal composition and/or weathering processes. Here we examine the growing body of chemical data on soils in Gusev crater and Meridiani Planum returned by the Alpha Particle X-ray Spectrometer (APXS) instruments on the rovers Spirit (MERA) and Opportunity (MERB), following on earlier results based on smaller data sets [1-4].

Mittlefehldt, D. W.↗

JWST NIRSpec Cryogenic Light Shield Mechanism

The focal plane detectors for the Near-Infrared Spectrometer (NIRSpec) instrument on the James Webb Space Telescope (JWST) require a light tight cover for calibration along with an open field-of-view during ground performance testing within a cryogenic dewar. In order to meet the light attenuation requirements and provide open and closed fields of view without breaking vacuum, a light shield mechanism was designed. This paper describes the details of the light shield mechanism design and test results. Included is information on the labyrinth light path design, motor capability and performance, dry film lubrication, mechanism control, and mechanism cryogenic performance results.

Hale, Kathleen↗

JWST NIRSpec Cryogenic Light Shield Mechanism

The focal plane detectors for the Near-Infrared Spectrometer (NIRSpec) instrument on the James Webb Space Telescope (JWST) require a light tight cover for calibration along with an open field-of-view during g round performance testing within a cryogenic dewar. In order to meet the light attenuation requirements and provide open and closed fields of view without breaking vacuum, a light shield mechanism was designe d. This paper describes the details of the light shield mechanism design and test results. Included is information on the labyrinth light p ath design, motor capability and performance, dry film lubrication, m echanism control, and mechanism cryogenic performance results.

Hale, Kathleen↗

Requirements for long-life mechanical cryocoolers for space applications

The growing demand for long wavelength infrared and submillimeter imaging instruments for space observational applications, together with the emergence of the multiyear life Oxford University Stirling cycle cooler, has led to a rapidly expanding near term commitment to mechanical cryocoolers throughout the subkelvin to 150 K temperature range for long-life space missions. To satisfy this growing commitment, emerging cryocoolers must successfully address not only the input power, cooling power, and mass constraints of the spacecraft and instruments, but also the broad array of complex interface requirements that critically affect successful integration to the sensitive instrument detectors. Generic requirements are presented for each of the cryocooler requirement areas, which are then contrasted with the projected capabilities of emerging space cryocoolers. The degree of match is used to highlight both the strengths of existing technologies and the areas in need of increased development.

Ross, R. G., Jr.↗