Search NASA⌕ Search

SEARCH · Search NASA

Results for “Micron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Radiation testing of 2.4 micron wavelength extended InGaAs photodiodes for 100 MeV/n carbon ions

We have successfully tested simultaneously 2.4 Micron Wavelength, Extended InGaAs Photodiodes having diameters of 20, 30, 40, 50, 100, 150, 200, 250, and 290 Micron, coupled with a Single Mode Fiber using 100 MeV/n Carbon (C) Ions up to a cumulative dose of ~40 krad. During irradiation, the devices were maintained at dry ice temperature, reverse biased at 100 mV, and their leakage current was continuously monitored in-situ during the run. After the exposure was completed, all nine devices were monitored for any change in their leakage current at 100 mV and room temperature for several weeks to monitor any annealing effects that may occur. Nine Photodiodes with the above varying diameters were radiated with 100 MeV/n Carbon Ions with a fluence of 10 6 , 10 7 , 10 8 , 10 9 , and 10 10 ions/cm 2 at each fluence level. At 100 MeV/n the Linear Energy Transfer (LET) of Carbon Ion is ~0.156 MeV-cm 2 /mg in Extended InGaAs, which is an order magnitude more than Proton (H) and Helium (He) Ions of 100 MeV/n energy. Thus, significant displacement damage is anticipated in the Extended InGaAs Photodiode with 100 MeV/n Carbon Ions with a total fluence of 1 × 1010 ions/cm 2 . Pre- and Post- radiation results were also measured for: (1) Leakage Current Vs. Voltage for the Extended InGaAs Photodiodes; (2) Responsivity (Quantum Efficiency) in A/W for Photodiodes; and (3) Bandwidth of the Photodiodes. All devices were found to be fully functional at the normal operating conditions and at both dry ice and room temperature. The leakage current increased up to a factor of ~2X at lower bias of 100 mV at the highest fluence of 10 10 ions/cm 2 , but not significantly at higher bias of 2 V. Finally, we did not observe any post radiation annealing effect for leakage current at room temperature and 100 mV bias for any of the devices after several weeks of data logging.

2.4 micron wavelength↗

Failure analysis and design principles of silicon-based lithium-ion batteries using micron-sized porous silicon/carbon composite

Significant progresses have been made to overcome the fundamental challenges in silicon (Si)-based lithium-ion batteries (LIBs). However, much less work have been reported on the design and failure analysis these batteries for practical applications. In this work, we analyzed various cell design parameters affecting the performance of pouch cells using micron-sized porous Si with nano-pore structure and coated by pitch-carbon (p-Si/C). The correlation among particle level, electrode level, and cell level properties, especially the effect of electrode density on the volumetric capacity density of Si anode and full batteries have been systematically investigated. It is found that the corrosion of p-Si/C particle surface is the main failure mechanisms on the eventual capacity loss, while Li plating on anode electrode surface is the main reason for the fast capacity loss in later stage of cycling. The volumetric capacity of Si anode highly depends on both electrode density and the Si content. Moreover, the prelithiation of Si anodes is found to increase energy density while decreasing cycle life of Si-based full cells. Finally, the pathways and strategies for adoption of micron-sized p-Si/C anodes in LIBs have been proposed for their practical applications.

25 ENERGY STORAGE↗

All-polymer organic solar cells with nano-to-micron hierarchical morphology and large light receiving angle

Distributed photovoltaics in living environment harvest the sunlight in different incident angles throughout the day. The development of planer solar cells with large light-receiving angle can reduce the requirements in installation form factor and is therefore urgently required. Here, thin film organic photovoltaics with nano-sized phase separation integrated in micro-sized surface topology is demonstrated as an ideal solution to proposed applications. All-polymer solar cells, by means of a newly developed sequential processing, show large magnitude hierarchical morphology with facilitated exciton-to-carrier conversion. The nano fibrilar donor-acceptor network and micron-scale optical field trapping structure in combination contributes to an efficiency of 19.06% (certified 18.59%), which is the highest value to date for all-polymer solar cells. Furthermore, the micron-sized surface topology also contributes to a large light-receiving angle. A 30% improvement of power gain is achieved for the hierarchical morphology comparing to the flat-morphology devices. These inspiring results show that all-polymer solar cell with hierarchical features are particularly suitable for the commercial applications of distributed photovoltaics due to its low installation requirement.

14 SOLAR ENERGY↗

A wide-field micro-computed tomography detector: micron resolution at half-centimetre scale

Ideal three-dimensional imaging of complex samples made up of micron-scale structures extending over mm to cm, such as biological tissues, requires both wide field of view and high resolution. For existing optics and detectors used for micro-CT (computed tomography) imaging, sub-micron pixel resolution can only be achieved for fields of view of <2 mm. This article presents a unique detector system with a 6 mm field-of-view image circle and 0.5 µm pixel size that can be used in micro-CT units utilizing both synchrotron and commercial X-ray sources. A resolution-test pattern with linear microstructures and whole adult Daphnia magna were imaged at beamline 8.3.2 of the Berkeley Advanced Light Source. Volumes of 10000 × 10000 × 7096 isotropic 0.5 µm voxels were reconstructed over a 5.0 mm × 3.5 mm field of view. Measurements in the projection domain confirmed a 0.90 µm measured spatial resolution that is largely Nyquist-limited. This unprecedented combination of field of view and resolution dramatically reduces the need for sectional scans and computational stitching for large samples, ultimately offering the means to elucidate changes in tissue and cellular morphology in the context of larger, whole, intact model organisms and specimens. This system is also anticipated to benefit micro-CT imaging in materials science, microelectronics, agricultural science and biomedical engineering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The mechanical response of micron-sized molecular crystals

Abstract Microstructures and corresponding properties of compacted powders ultimately depend on the mechanical response of individual particles. In principle, computational simulations can predict the results of powder compaction processes, but the selection of appropriate models for both particle–particle interactions and particle deformations across all relevant length scales remain nontrivial tasks, especially in material systems lacking detailed mechanical property information. The work presented here addresses these issues by conducting uniaxial compressions in situ inside of a scanning electron microscope to characterize the mechanical response of individual micron-sized particles of a molecular crystal, hexanitrohexaazaisowurtzitane (CL-20). This experimental approach enabled the collection of quantitative force and displacement data alongside simultaneous imaging to capture morphology changes. The results reveal information about elastic deformation, yield, plastic deformation, creep, and fracture phenomena. Accordingly, this work demonstrates a generalizable approach for assessing the mechanical response of individual micron-sized molecular crystal particles and utilizing those responses in particle-level models. Graphic abstract

36 MATERIALS SCIENCE↗

The response of a 300 micron silicon detector to monoenergetic neutrons determined by the use of the Monte Carlo technique

The response of a 300 micron thick silicon detector to an incident monoenergetic neutron beam is evaluated by the Monte Carlo method for the cases of both a shielded and a bare detector. The result of Monte Carlo calculation, using elastic, inelastic, and absorption reactions indicates that the response of the silicon detector to neutrons is basically due to the elastic scattering. In addition, the gamma rays generated in the shield of the detector will result in a response which is 3 or 4 orders of magnitude smaller than response to incident photons. The response of a bare silicon detector is calculated for neutron energies up to 6 MeV and bias energies from 50 to 250 KeV. It is found that the maximum response for a 300 micron thick silicon detector is less than .004 c/n within this selected neutron and bias energy range. When the pulse height defect is introduced in the calculation the results at low energy neutrons were reduced.

Tahezadeh, M.↗

Improvement of synoptic scale moisture and wind field analyses using the Nimbus 4 THIR 6.7 micron observations

The Nimbus 4 temperature-humidity infrared radiometer (THIR) monitors radiation in the 6.5 to 7.2 micron water vapor absorption with a 23 kilometer spatial resolution at the sub-satellite point. Radiation monitored in this spectral region results primarily from emission in the 250 to 500 millibar region of the upper troposphere. The THIR 6.7 micron observations are readily available in photofacsimile imagery form which shows very distinctive patterns associated with spatial variations in atmospheric water vapor. These radiometric observations were combined in several instances with moisture values measured in the upper troposphere by the standard radiosonde network. In each instance, the result is a much more consistent analysis showing increased spatial detail that agrees with the radiometric observations and does not compromise the conventional data. The improved moisture analyses show relatively dry and moist tongues that are very difficult or impossible to infer from the conventional data alone. The patterns in the moisture fields can be tracked over 12 and 24 hour periods. In addition, by keeping in mind the advective properties of the moisture field, success was achieved in improving streamline analyses at the 400 mb level over data sparse regions on a global scale.

Steranko, J.↗

Estimation of sea surface temperature from remote measurements in the 11-13 micron window region

The Nimbus-4 IRIS data was examined in the spectral region 775 to 1250/cm (8-13 microns) for useful information to determine the sea surface temperature. The high spectral resolution data of IRIS was degraded to low resolution by averaging to simulate a multi-channel radiometer in the window region. These simulated data show that within the region 775-975/cm (12.9-10.25 microns) the brightness temperatures are linearly related to the absorption parameters. Such a linear relationship is observed over cloudy as well as clear regions and over a wide range of latitudes. From this linear relationship it is feasible to correct for the atmospheric attenuation and get the sea surface temperature, accurate to within 1 K, in a cloud free field of view. The information about the cloud cover is taken from the TV pictures and BUV albedo measurements on board the Nimbus-4 satellite.

Prabhakara, C.↗

Temperatures of Titan and the Galilean satellites at 20 microns.

Determination of the effective temperatures of the satellites by means of broad-band observations made at Mauna Kea in 1971. The temperatures of the Galilean satellites are in fair agreement with observations at shorter wavelengths and with theory. The 20-micron flux of Titan is nearly an order of magnitude lower than expected, suggesting either low surface emissivity or high atmospheric opacity between 18 and 25 micron. Hydrogen could produce the required opacity, but the abundance needed is large.

Morrison, D.↗

Balloon observations of galactic and extragalactic objects at 100 microns.

Recent far-infrared balloon-borne instruments have yielded observations of a number of bright sources at 100 microns. Many of these coincide with HII regions where molecular line emision has been detected. There is some indication of 100 micron emission which does not coincide with radio measurements.

Hoffmann, W. F.↗

Luminosity functions for K giant stars derived from the two-micron sky survey.

Description of a method for determining either the space density or the luminosity function from star counts covering large areas of sky. Space density is assumed to vary only in the direction perpendicular to the galactic plane. The method extends that derived for use with the star counts in the Selected Areas by allowing for an integration over a wide and continuous range of galactic latitudes, and is therefore applicable to surveys where the number of stars per square degree is small but the area surveyed is an appreciable fraction of the sky. The catalog (IRC) produced from the 2-micron sky survey at Caltech is such a survey. Application of the method to a selection of IRC stars dominated by K giants shows that if these stars obey Oort's determination of their normalized space density perpendicular to the galactic plane than the dispersion of their 2.2-micron luminosity distribution must be large - i.e., on the order of plus or minus 1.0 min within a single spectral subtype. This result is in accord with conclusions recently set forth by Jung (1970).

Hughes, E. E., Jr.↗

Application of Nimbus 4 THIR 6.7-micron observations to regional and global moisture and wind field analyses.

The Nimbus 4 temperature-humidity infrared radiometer (THIR) monitors radiation in the 6.5 to 7.2-micron water vapor absorption region with a 23-km spatial resolution at the subsatellite point. Radiation monitored in this spectral region results primarily from emission in the 250 to 500-mb region of the upper troposphere. The THIR 6.7-micron observations are readily available in photofacsimile imagery form which shows very distinctive patterns associated with spatial variations in atmospheric water vapor. These radiometric observations have been combined in several instances with moisture values measured in the upper troposphere by the standard radiosonde network. In each instance, the result is a much more consistent analysis showing increased spatial detail that agrees with the radiometric observations and does not compromise the conventional data. The improved moisture analyses show relatively dry and moist tongues that are very difficult or impossible to infer from the conventional data alone.

Steranka, J.↗

High-resolution maps of Jupiter at five microns.

The distribution of 5-micron radiation, emitted from a large number of discrete sources from Jupiter, was observed during the 1972 apparition. These sources are less bright than those observed by Westphal (1969). At least 50 discrete sources having brightness temperatures exceeding 227 K were revealed which were mainly located within three narrow-latitude bands. Strong correlation exists between the 5-micron brightness temperatures of Jovian features and their colors as recorded photographically.

Keay, C. S. L.↗

2.2- and 3.5-micron polarization measurements of the Becklin-Neugebauer object in the Orion Nebula.

Independent measurements of the Becklin-Neugebauer (BN) object in the Orion Nebula yield large values of linear polarization in wavelength bands centered at 2.2 and 3.4 microns. The 10 to 15% polarization at 2.2 microns of the BN object is larger than any yet measured for an extraterrestrial object. The large polarization probably originates from the scattering of the radiation by dust grains.

Loer, S. J.↗