Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Effect of fuel rate and annealing process of LiFePO{sub 4} cathode material for Li-ion batteries synthesized by flame spray pyrolysis method

In this study the effect of fuel rate and annealing on particle formation of LiFePO{sub 4} as battery cathode using flame spray pyrolysis method was investigated numerically and experimentally. Numerical study was done using ANSYS FLUENT program. In experimentally, LiFePO{sub 4} was synthesized from inorganic aqueous solution followed by annealing. LPG was used as fuel and air was used as oxidizer and carrier gas. Annealing process attempted in inert atmosphere at 700°C for 240 min. Numerical result showed that the increase of fuel rate caused the increase of flame temperature. Microscopic observation using Scanning Electron Microscopy (SEM) revealed that all particles have sphere and polydisperse. Increasing fuel rate caused decreasing particle size and increasing particles crystallinity. This phenomenon attributed to the flame temperature. However, all produced particles still have more amorphous phase. Therefore, annealing needed to increase particles crystallinity. Fourier Transform Infrared (FTIR) analysis showed that all particles have PO4 function group. Increasing fuel rate led to the increase of infrared spectrum absorption corresponding to the increase of particles crystallinity. This result indicated that phosphate group vibrated easily in crystalline phase. From Electrochemical Impedance Spectroscopy (EIS) analysis, annealing can cause the increase of Li{sup +} diffusivity. The diffusivity coefficient of without and with annealing particles were 6.84399×10{sup −10} and 8.59888×10{sup −10} cm{sup 2} s{sup −1}, respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetic and optical properties of electrospun hollow nanofibers of SnO{sub 2} doped with Ce-ion

Cerium doped SnO{sub 2} hollow nanofibers were synthesized by electrospinning. High resolution scanning electron microscope (HRSEM) and transmission electron microscopy (TEM) analysis showed hollow nanofibers with diameters around ∼200 nm. The optimized substitution of Ce ion into SnO{sub 2} lattices happened above 6 mol. % doping as confirmed by Powder X-ray diffraction (XRD) studies. Optical band gap was decreased by the doping confirming the direct energy transfer between f-electrons of rare earth ion and the SnO{sub 2} conduction or valence band. The compound also exhibited room temperature ferromagnetism with the saturation magnetization of 19 × 10{sup −5} emu/g at 6 mol. %. This study demonstrates the Ce doped SnO{sub 2} hollow nanofibers for applications in magneto-optoelectronic devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Effect of applied voltage on surface properties of anodised titanium in mixture of β-glycerophosphate (β-GP) and calcium acetate (CA)

Anodic oxidation is a surface modification method which combines electric field driven metal and oxygen ion diffusion for formation of oxide layer on the anode surface. This method has been widely used to modify the surface morphology of biomaterial especially titanium. This study aimed to investigate the effect of applied voltage on titanium. Specifically, the titanium foil was anodised in mixture of β-glycerophosphate disodium salt pentahydrate (β-GP) and calcium acetate monohydrate (CA) with different applied voltage (50-350 V), electrolyte concentration (0.04 M β-GP + 0.4 M CA), anodising time (10minutes) and current density (50 and 70 mA.cm{sup −2}) at room temperature. Surface oxide properties of anodised titanium were characterised by digital single-lens reflex camera (DSLR camera), field emission scanning electron microscope (FESEM) and atomic force microscopy (AFM). At lower applied voltage (≤150 V), surface of titanium foils were relatively smooth. With increasing applied voltage (≥250 V), the oxide layer became more porous and donut-shaped pores were formed on the surface of titanium foils. The AFM results indicated that the surface roughness of anodised titanium increases with increasing of applied voltage. The porous and rough surface is able to promote the osseointegration and reduce the suffering time of patient.

36 MATERIALS SCIENCE↗

Morphological and spectroscopic analysis of cellulose nanocrystals extracted from oil palm empty fruit bunch fiber

This work evaluates the use of oil palm empty fruit bunch (OPEFB) fiber as a source of cellulose to obtain nanocrystalline cellulose (CNC) by acid hydrolysis reaction. The raw OPEFB fibers were pretreated with aqueous Sodium hydroxide at 80°C followed by bleaching treatment and further hydrolyzed with Sulphuric acid at 45°C with limited range of hydrolysis time and acid concentration. The resulting CNC’s were characterized for spectroscopic, crystallographic and morphological properties using Fourier Transform Infrared Spectroscopy (FTIR), X-ray Diffractometer (XRD), Transmission Electron Microscope (TEM) and Atomic Force Microscopy (AFM). Finding of this study shows that the properties of CNC’s are strongly dependent on the hydrolysis time and acid concentration.

36 MATERIALS SCIENCE↗

Advancing Reel-to-Reel Inspection Techniques for Long HTS Conductors: Comparison and Innovations

The continuous advancement of high-temperature superconductor (HTS) technologies has greatly accelerated the development and deployment of HTS applications. Among the critical tools supporting these advancements are reel-to-reel (R2R) critical current (I c ) measurement techniques, which are extensively used by both manufacturers and end users to characterize long-length REBCO conductors. These techniques play a vital role in quality assurance and quality control (QA/QC), ensuring the reliability and performance of HTS conductors and applications throughout the production cycle. We have developed a range of in-house devices for R2R measurements at the University of Houston and Princeton Plasma Physics Laboratory. These include one-dimensional (1D) scan using a magnetic circuit (MC) and two-dimensional (2D) magnetic field mapping systems based on scanning probe array microscope (SPAM) or scanning probe microscopy (SPM). Each technique offers distinct advantages: the MC system provides ultra-fast scanning speeds, ideal for rapid inspection in large-scale industrial production; the high-resolution SPM delivers detailed insights for conductor research and development; and the SPAM, with its simpler mechanical setup, can be upgraded for higher field and lower temperature conditions with a balanced 2D resolution. Here we compared the magnetization and detection capabilities of these techniques through experiments on rare-earth barium copper oxide (REBCO) coated conductor samples, with data analysis supported by numerical simulations. Based on our comprehensive comparative studies, we propose enhancements for each measurement system and provide guidelines for selecting the optimal technique combinations to meet specific application requirements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of an Innovative High-Thermal Conductivity UO2 Ceramic Composites Fuel Pellets with Carbon Nano-Tubes Using Spark Plasma Sintering

Uranium dioxide (UO2) is the most common fuel material in commercial nuclear power reactors. Despite its numerous advantages such as high melting point, good high-temperature stability, good chemical compatibility with cladding and coolant, and resistance to radiation, it suffers from low thermal conductivity that can result in large temperature gradients within the UO2 fuel pellet, causing it to crack and release fission gases. Thermal swelling of the pellets also limits the lifetime of UO2 fuel in the reactor. To mitigate these problems, we propose to develop novel UO2 fuel with uniformly distributed carbon nanotubes (CNTs) that can provide high-conductivity thermal pathways and can eliminate fuel cracking and fission gas release due to high temperatures. CNTs have been investigated extensively for the past decade to explore their unique physical properties and many potential applications. CNTs have high thermal conductivity (6600 W/mK for an individual single- walled CNT and >3000 W/mK for an individual multi-walled CNT) and high temperature stability up to 2800°C in vacuum and about 750°C in air. These properties make them attractive candidates in preparing nano-composites with new functional properties. The objective of the proposed research is to develop high thermal conductivity of UO2–CNT composites without affecting the neutronic property of UO2 significantly. The concept of this goal is to utilize a rapid sintering method (5–15 min) called spark plasma sintering (SPS) in which a mixture of CNTs and UO2 powder are used to make composites with different volume fractions of CNTs. Incorporation of these nanoscale materials plays a fundamentally critical role in controlling the performance and stability of UO2 fuel. We will use a novel in situ growth process to grow CNTs on UO2 particles for rapid sintering and develop UO2-CNT composites. This method is expected to provide a uniform distribution of CNTs at various volume fractions so that a high thermally conductive UO2-CNT composite is obtained with a minimal volume fraction of CNTs. The mixtures are sintered in the SPS facility at a range of temperatures, pressures, and time durations so as to identify the optimal processing conditions to obtain the desired microstructure of sintered UO2-CNT pellets. The second objective of the proposed work is to identify the optimal volume fraction of CNTs in the microstructure of the composites that provides the desired high thermal conductivity yet retaining the mechanical strength required for efficient function as a reactor fuel. We will systematically study the resulting microstructure (grain size, porosity, distribution of CNTs, etc.) obtained at various SPS processing conditions using optical microscopy, scanning electron microscopy (SEM), and transmission electron microscope (TEM). We will conduct indentation hardness measurements and uniaxial strength measurements as a function of volume fraction of CNTs to determine the mechanical strength and compare them to the properties of UO2. The fracture surfaces will be studied to determine the fracture characteristics that may relate to the observed cracking during service. Finally, we will perform thermal conductivity measurements on all the composites up to 1000° C. This study will relate the microstructure, mechanical properties, and thermal properties at various volume fractions of CNTs. The overall intent is to identify optimal processing conditions that will provide a well-consolidated compact with optimal microstructure and thermo-mechanical properties. The deliverables include: (1) fully characterized UO2-CNT composite with optimal CNT volume fraction and high thermal conductivity and (2) processing conditions for production of UO2-CNT composite pellets using SPS method.

Subhash, Ghatu↗

The Fluid Processing Apparatus: from Flight Hardware to Electron Micrographs

Since the early years of space biology, a major drawback in spaceflight plant experiments has been the inability to fix specimens in microgravity, relying instead on fixation after return to Earth. As there, it is of a growing interest to look at the effect of microgravity on the structure and the developmental polarity of root graviperceptive cells, or columella cells, and so, it is important to use flight hardware which allows specimen fixation in space therefore avoiding the confounding effects of rapid readaptation to gravity after landing. As part of the Bioserve Space Technologies, a Center for the Commercial Development of Space (CCDS), we now have experiment flight opportunities through the Commercial Generic Bioprocessing Apparatus (CGBA) payload. In this study the Fluid Processing Apparatus (FPA) was used to grow seedlings for a limited period of time prior to fixation of the tissue in a microgravity environment. Upon return to Earth, the samples were processed for electron microscopy. This report describes the microscopic data obtained from the two space flights (STS-54 and STS-60). In both cases, the electron micrographs of the columella cells revealed well preserved cell structure, well defined microtubules, and the presence of calcium precipitates formed by a antimonate precipitation method.

Hilaire, Emmanuel↗

Fast electron microscopy via compressive sensing

Various technologies described herein pertain to compressive sensing electron microscopy. A compressive sensing electron microscope includes a multi-beam generator and a detector. The multi-beam generator emits a sequence of electron patterns over time. Each of the electron patterns can include a plurality of electron beams, where the plurality of electron beams is configured to impart a spatially varying electron density on a sample. Further, the spatially varying electron density varies between each of the electron patterns in the sequence. Moreover, the detector collects signals respectively corresponding to interactions between the sample and each of the electron patterns in the sequence.

36 MATERIALS SCIENCE↗

Fourier plane imaging microscopy

We show how the image of an unresolved photonic crystal can be reconstructed using a single Fourier plane (FP) image obtained with a second camera that was added to a traditional compound microscope. We discuss how Fourier plane imaging microscopy is an application of a remarkable property of the obtained FP images: they contain more information about the photonic crystals than the images recorded by the camera commonly placed at the real plane of the microscope. We argue that the experimental results support the hypothesis that surface waves, contributing to enhanced resolution abilities, were optically excited in the studied photonic crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Charge collection microscopy of in-situ switchable PRAM line cells in a scanning electron microscope: Technique development and unique observations

An imaging method has been developed based on charge collection in a scanning electron microscope (SEM) that allows discrimination between the amorphous and crystalline states of Phase-change Random Access Memory (PRAM) line cells. During imaging, the cells are electrically connected and can be switched between the states and the resistance can be measured. This allows for electrical characterization of the line cells in-situ in the SEM. Details on sample and measurement system requirements are provided which turned out to be crucial for the successful development of this method. Results show that the amorphous or crystalline state of the line cells can be readily discerned, but the spatial resolution is relatively poor. Nevertheless, it is still possible to estimate the length of the amorphous mark, and also for the first time, we could directly observe the shift of the amorphous mark from one side of the line cell to the other side when the polarity of the applied (50 ns) RESET pulse was reversed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low axial drift stage and temperature controlled liquid cell for z-scan fluorescence correlation spectroscopy in an inverted confocal geometry

A recent iteration of fluorescence correlation spectroscopy (FCS), z-scan FCS, has drawn attention for its elegant solution to the problem of quantitative sample positioning when investigating two-dimensional systems while simultaneously providing an excellent method for extracting calibration-free diffusion coefficients. Unfortunately, the measurement of planar systems using (FCS and) z-scan FCS still requires extremely mechanically stable sample positioning, relative to a microscope objective. As axial sample position serves as the inherent length calibration, instabilities in sample position will affect measured diffusion coefficients. Here, we detail the design and function of a highly stable and mechanically simple inverted microscope stage that includes a temperature controlled liquid cell. The stage and sample cell are ideally suited to planar membrane investigations, but generally amenable to any quantitative microscopy that requires low drift and excellent axial and lateral stability. In the present work we evaluate the performance of our custom stage system and compare it with the stock microscope stage and typical sample sealing and holding methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ plasmonic tip preparation and validation techniques for scanning tunneling microscopy

Among the many parts constituting a scanning tunneling microscope, the metallic tip is the component that directly interacts with the specimen and plays a critical role in visualizing the physical quantity of interest. While tip materials such as W and Pt–Ir are commonly used for topographic imaging and their preparation is well-documented, the preparation of plasmonic materials such as Ag for tip-enhanced Raman spectroscopy is relatively less standardized. Furthermore, we present several in situ Ag tip preparation and validation techniques for the microscopist to use depending on their intended application, including atomic resolution imaging, scanning tunneling spectroscopy (STM), and tip-enhanced Raman spectro-microscopy in ultrahigh vacuum. Besides optical applications, these methods are not limited to Ag but also applicable to other STM tip materials.

47 OTHER INSTRUMENTATION↗

Measurement of the unstained biological sample by a novel scanning electron generation X-ray microscope based on SEM

We introduced a novel X-ray microscope system based on scanning electron microscopy using thin film, which enables the measurement of unstained biological samples without damage. An unstained yeast sample was adsorbed under a titanium (Ti)-coated silicon nitride (Si{sub 3}N{sub 4}) film 90 nm thick. The X-ray signal from the film was detected by an X-ray photodiode (PD) placed below the sample. With an electron beam at 2.6 kV acceleration and 6.75 nA current, the yeast image is obtained using the X-ray PD. The image is created by soft X-rays from the Ti layer. The Ti layer is effective in generating the characteristic 2.7-nm wavelength X-rays by the irradiation of electrons. Furthermore, we investigated the electron trajectory and the generation of the characteristic X-rays within the Ti-coated Si{sub 3}N{sub 4} film by Monte Carlo simulation. Our system can be easily utilized to observe various unstained biological samples of cells, bacteria, and viruses.

60 APPLIED LIFE SCIENCES↗

Quantitative high dynamic range beam profiling for fluorescence microscopy

Modern developmental biology relies on optically sectioning fluorescence microscope techniques to produce non-destructive in vivo images of developing specimens at high resolution in three dimensions. As optimal performance of these techniques is reliant on the three-dimensional (3D) intensity profile of the illumination employed, the ability to directly record and analyze these profiles is of great use to the fluorescence microscopist or instrument builder. Though excitation beam profiles can be measured indirectly using a sample of fluorescent beads and recording the emission along the microscope detection path, we demonstrate an alternative approach where a miniature camera sensor is used directly within the illumination beam. Measurements taken using our approach are solely concerned with the illumination optics as the detection optics are not involved. We present a miniature beam profiling device and high dynamic range flux reconstruction algorithm that together are capable of accurately reproducing quantitative 3D flux maps over a large focal volume. Performance of this beam profiling system is verified within an optical test bench and demonstrated for fluorescence microscopy by profiling the low NA illumination beam of a single plane illumination microscope. The generality and success of this approach showcases a widely flexible beam amplitude diagnostic tool for use within the life sciences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid Phase Characterization of Tank 241-C-108 Residual Waste Solids Samples

This report presents the results for solid phase characterization (SPC) of solid samples removed from tank 241-C-108 (C-108) on August 12-13,2012, using the off-riser sampler. Samples were received at the 222-S Laboratory on August 13 and were described and photographed. The SPC analyses that were performed include scanning electron microscopy (SEM) using the ASPEX(R)l scanning electron microscope, X-ray diffraction (XRD) using the Rigaku(R) 2 MiniFlex X-ray diffractometer, and polarized light microscopy (PLM) using the Nikon(R) 3 Eclipse Pol optical microscope. The SEM is equipped with an energy dispersive X-ray spectrometer (EDS) to provide chemical information. Gary A. Cooke conducted the SEM analysis, John A. Pestovich performed the XRD analysis, and Dr. Heinz J. Huber performed the PLM examination. The results of these analyses are presented here.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low-voltage nanodomain writing in He-implanted lithium niobate crystals

A scanning force microscope tip is used to write ferroelectric domains in He-implanted single-crystal lithium niobate and subsequently probe them by piezoresponse force microscopy. Investigation of cross-sections of the samples showed that the buried implanted layer, approx1 mum below the surface, is nonferroelectric and can thus act as a barrier to domain growth. This barrier enabled stable surface domains of <1 mum size to be written in 500 mum thick crystal substrates with voltage pulses of only 10 V applied to the tip.

36 MATERIALS SCIENCE↗

Recent Advances in Analytical Electron Microscopy for Irradiated Materials

Analytical electron microscopy (AEM) in the scanning transmission electron microscope (STEM) has long been a staple of post-irradiation examination (PIE) and materials development campaigns. Recently, new advances in both STEM hardware and post-processing data-analysis software, along with ancillary advances such as in focused ion beam (FIB) sample preparation, has led to exciting advances in the quantity and quality of data that can be obtained. This talk will summarize recent experiments performed at Oak Ridge National Laboratory (ORNL), especially work on neutron-irradiated materials and fuels taking advantage of a newly-installed latest-generation AEM tool in the ORNL irradiated materials laboratories. ORNL installed a new FEI Talos F200X microscope, a 200 keV, high-brightness Schottky emission AEM system optimized for high-speed, high-efficiency X-ray mapping experiments. The F200X features the FEI 'SuperX' four-sector silicon drift detector (SDD) X-ray detector, which provides 0.9 sr solid angle of collection. By combining the high-brightness electron source, latest-generation electron optics, and fast computers and pulse processors, X-ray mapping speed is increased by a factor of 50-100 x compared to the previous-generation instruments. In addition to improvements in hardware, data mining via multivariate statistical analysis (MVSA) allows for maximum insight to the data obtained from the new hardware. MVSA data mining of the X-ray maps allows, for instance, unbiased computational identification of the phases present, and discovery of small phases or precipitates not expected by the human analyst. This talk will present examples of experiments performed using the most modern AEM tools and software. Silicon carbide is a major candidate for next-generation nuclear applications. Nano-infiltration by transient eutectic (NITE) SiC requires low sintering temperatures. X-ray mapping of the NITE structure find pockets of different oxides, such as Zr-Y-oxide, Y-Al-oxide, and yttria. MVSA data mining finds the regions where different oxides are present and indicates that Y additions preferentially wet grain boundaries, where Zr additions are preferentially concentrated at grain triple points. SiC coatings from AGR-I experiment TRISO particles were found to contain significant quantities of fission products (e.g., Pd) as well as actinides (U, Pu). MVSA data mining found complex precipitates and grain boundary films of the fission products and actinides deep (∼several microns) into the SiC layer. Advanced AEM methods, combined with MVSA data mining, makes possible both rapid and detailed PIE. Ferritic alloys, such as accident-tolerant FeCrAl grades, benefit greatly from advanced AEM examination. Neutron-irradiated FeCrAl precipitates the detrimental Cr-rich α' phase. Because the SuperX SDD system has four detectors, it is possible to obtain high X-ray count rates even on a highly tilted specimen, as might be needed to obtain STEM images of dislocation loops. Results on neutron-irradiated FeCrAl indicates that α' size and number density can be obtained by AEM, and MVSA results determine that minor elements (such as Si) has complex radiation-induced segregation behavior at grain boundaries. We have also developed and validated computer models of the AEM experiment, allowing different microstructures' X-ray map results to be simulated for different STEM instruments. This allows X-ray mapping to be more quantitative, such as by estimating what size nanoclusters in an oxide-dispersion strengthened steel would be visible or invisible in STEM. In summary, new advanced AEM technology provides a major leap forward in experiments possible in PIE of irradiated materials. (authors)

36 MATERIALS SCIENCE↗

Understanding polaronic transport in complex oxides by combining precise synthesis and first-principles many-body theory

In complex oxides, charge carriers often couple strongly with lattice vibrations to form polarons–entangled electron–phonon quasiparticles whose transport properties remain difficult to characterize. Experimental access to intrinsic polaronic transport requires ultraclean samples, while theoretical description demands methods beyond low-order perturbation theory. Here, we show a predictive theory–experiment workflow to study polaron transport in complex oxides. Focusing on a prototypical polaronic oxide, anatase TiO 2 , we combine growth of high-quality oxygen-vacancy-doped films using hybrid molecular beam epitaxy with a first-principles electron–phonon diagrammatic Monte-Carlo (FEP-DMC) framework recently developed for accurate polaron predictions. Our films exhibit record-high electron mobility for anatase TiO 2 , in excellent agreement with FEP-DMC calculations conducted prior to experiment, which predict a room-temperature mobility of 45 ± 15 cm −2 V −1 s −1 and a mobility-temperature scaling of μ ∝ T −1.9 ± 0.077 . Microscopic analysis using scanning transmission electron microscopy and x-ray photoelectron spectroscopy reveals the role of oxygen vacancies in modulating transport at lower temperatures. FEP-DMC further provides quantitative insight into polaron formation energy, phonon cloud distribution, lattice distortion around the polaron, and the polaronic contribution to mobility. Together, these results provide a deeper microscopic understanding of large-polaron transport in a complex oxide and provide the blueprint to characterize other polaronic materials.

anatase TiO2↗