Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscopic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Microscopic ejecta measurements from hypervelocity impacts on aluminum and powdered regolith targets

Meteoroids and space debris pose a two-fold threat to spacecraft due to the risk of both mechanical damage from the impact and electrical damage from the impact-generated plasma, which produces electromagnetic emissions. Analysis of impact products, however, has the potential to provide useful information about planetary rings and small solar system bodies, such as asteroids and comets. Understanding the plasma dynamics and radiation mechanism is essential to addressing the impact threat and extracting science data from impacts. Charge attachment to condensed-phase debris may lead to a dusty plasma under certain conditions, so interpreting hypervelocity impacts requires knowledge of both the nature of the plasma and of the ejecta. We address the latter with measurements of the microscopic ejecta distribution produced by light gas gun impacts on solid aluminum and powdered regolith simulant targets. We examine both the size and shape of the ejecta using thin-film witness plates and find that the size distributions of microscopic ejecta follow power laws. Observations from the powdered regolith simulant match well with disruption experiments of solid basalt, while measurements from the aluminum impacts diverge from extrapolations based on studies of macroscopic debris. Analysis of the ejecta shape shows a transition from smooth to irregularly shaped ejecta at the material grain size, and the shape of debris may provide insight on the phase of the ejected material. Finally, based on our results, we predict a significant number of secondary impacts on plasma sensors due to ejecta, even at considerable distance from the target, supporting the hypothesis that charged dust affects plasma measurements in the ejecta curtain.

42 ENGINEERING↗

Microscopic Gold Particle-Based Fiducial Markers for Proton Therapy of Prostate Cancer

Purpose: We examined the feasibility of using fiducial markers composed of microscopic gold particles and human-compatible polymers as a means to overcome current problems with conventional macroscopic gold fiducial markers, such as dose reduction and artifact generation, in proton therapy for prostate cancer. Methods and Materials: We examined two types of gold particle fiducial marker interactions: that with diagnostic X-rays and with a therapeutic proton beam. That is, we qualitatively and quantitatively compared the radiographic visibility of conventional gold and gold particle fiducial markers and the CT artifacts and dose reduction associated with their use. Results: The gold particle fiducials could be easily distinguished from high-density structures, such as the pelvic bone, in diagnostic X-rays but were nearly transparent to a proton beam. The proton dose distribution was distorted <5% by the gold particle fiducials with a 4.9% normalized gold density; this was the case even in the worst configuration (i.e., parallel alignment with a single-direction proton beam). In addition, CT artifacts were dramatically reduced for the gold particle mixture. Conclusion: Mixtures of microscopic gold particles and human-compatible polymers have excellent potential as fiducial markers for proton therapy for prostate cancer. These include good radiographic visibility, low distortion of the depth-dose distribution, and few CT artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Microscopic Disease Extension in Three Dimensions for Non-Small-Cell Lung Cancer: Development of a Prediction Model Using Pathology-Validated Positron Emission Tomography and Computed Tomography Features

Purpose: One major uncertainty in radiotherapy planning of non-small-cell lung cancer concerns the definition of the clinical target volume (CTV), meant to cover potential microscopic disease extension (MDE) around the macroscopically visible tumor. The primary aim of this study was to establish pretreatment risk factors for the presence of MDE. The secondary aim was to establish the impact of these factors on the accuracy of positron emission tomography (PET) and computed tomography (CT) to assess the total tumor-bearing region at pathologic examination (CTV{sub path}). Methods and Materials: 34 patients with non-small-cell lung cancer who underwent CT and PET before lobectomy were included. Specimens were examined microscopically for MDE. The gross tumor volume (GTV) on CT and PET (GTV{sub CT} and GTV{sub PET}, respectively) was compared with the GTV and the CTV at pathologic examination, tissue deformations being taken into account. Using multivariate logistic regression, image-based risk factors for the presence of MDE were identified, and a prediction model was developed based on these factors. Results: MDE was found in 17 of 34 patients (50%). The MDE did not exceed 26 mm in 90% of patients. In multivariate analysis, two parameters (mean CT tumor density and GTV{sub CT}) were significantly associated with MDE. The area under the curve of the two-parameter prediction model was 0.86. Thirteen tumors (38%, 95% CI: 24-55%) were identified as low risk for MDE, being potential candidates for reduced-intensity therapy around the GTV. In the low-risk group, the effective diameter of the GTV{sub CT/PET} accurately represented the CTV{sub path}. In the high-risk group, GTV{sub CT/PET} underestimated the CTV{sub path} with, on average, 19.2 and 26.7 mm, respectively. Conclusions: CT features have potential to predict the presence of MDE. Tumors identified as low risk of MDE show lower rates of disease around the GTV than do high-risk tumors. Both CT and PET accurately visualize the CTV{sub path} in low-risk tumors but underestimate it in high-risk tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Radiotherapy for Locally Advanced Non-Small-Cell Lung Cancer Does Not Underdose the Microscopic Disease and has the Potential to Increase Tumor Control

Purpose: To evaluate doses to the microscopic disease (MD) in adaptive radiotherapy (ART) for locally advanced non-small-cell lung cancer (NSCLC) and to model tumor control probability (TCP). Methods and Materials: In a retrospective planning study, three-dimensional conformal treatment plans for 13 patients with locally advanced NSCLC were adapted to shape and volume changes of the gross tumor volume (GTV) once or twice during conventionally fractionated radiotherapy with total doses of 66 Gy; doses in the ART plans were escalated using an iso-mean lung dose (MLD) approach compared to non-adapted treatment. Dose distributions to the volumes of suspect MD were simulated for a scenario with synchronous shrinkage of the MD and GTV and for a scenario of a stationary MD despite GTV shrinkage; simulations were performed using deformable image registration. TCP calculations considering doses to the GTV and MD were performed using three different models. Results: Coverage of the MD at 50 Gy was not compromised by ART. Coverage at 60 Gy in the scenario of a stationary MD was significantly reduced from 92% {+-} 10% to 73% {+-} 19% using ART; however, the coverage was restored by iso-MLD dose escalation. Dose distributions in the MD were sufficient to achieve a TCP >80% on average in all simulation experiments, with the clonogenic cell density the major factor influencing TCP. The combined TCP for the GTV and MD was 19.9% averaged over all patients and TCP models in non-adaptive treatment with 66 Gy. Iso-MLD dose escalation achieved by ART increased the overall TCP by absolute 6% (adapting plan once) and by 8.7% (adapting plan twice) on average. Absolute TCP values were significantly different between the TCP models; however, all TCP models suggested very similar TCP increase by using ART. Conclusions: Adaptation of radiotherapy to the shrinking GTV did not compromise dose coverage of volumes of suspect microscopic disease and has the potential to increase TCP by >40% compared with radiotherapy planning without ART.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Copper-64-diacetyl-bis(N(4)-methylthiosemicarbazone) Pharmacokinetics in FaDu Xenograft Tumors and Correlation With Microscopic Markers of Hypoxia

Purpose: The behavior of copper-64-diacetyl-bis(N(4)-methylthiosemicarbazone) ({sup 64}Cu-ATSM) in hypoxic tumors was examined through a combination of in vivo dynamic positron emission tomography (PET) and ex vivo autoradiographic and histologic evaluation using a xenograft model of head-and-neck squamous cell carcinoma. Methods and Materials: {sup 64}Cu-ATSM was administered during dynamic PET imaging, and temporal changes in {sup 64}Cu-ATSM distribution within tumors were evaluated for at least 1 hour and up to 18 hours. Animals were sacrificed at either 1 hour (cohort A) or after 18 hours (cohort B) postinjection of radiotracer and autoradiography performed. Ex vivo analysis of microenvironment subregions was conducted by immunohistochemical staining for markers of hypoxia (pimonidazole hydrochloride) and blood flow (Hoechst-33342). Results: Kinetic analysis revealed rapid uptake of radiotracer by tumors. The net influx (K{sub i}) constant was 12-fold that of muscle, whereas the distribution volume (V{sub d}) was 5-fold. PET images showed large tumor-to-muscle ratios, which continually increased over the entire 18-hour course of imaging. However, no spatial changes in {sup 64}Cu-ATSM distribution occurred in PET imaging at 20 minutes postinjection. Microscopic intratumoral distribution of {sup 64}Cu-ATSM and pimonidazole were not correlated at 1 hour or after 18 hours postinjection, nor was {sup 64}Cu-ATSM and Hoechst-33342. Conclusions: The oxygen partial pressures at which {sup 64}Cu-ATSM and pimonidazole are reduced and bound in cells are theorized to be distinct and separable. However, this study demonstrated that microscopic distributions of these tracers within tumors are independent. Researchers have shown {sup 64}Cu-ATSM uptake to be specific to malignant expression, and this work has also demonstrated clear tumor targeting by the radiotracer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of calcination on microscopic and mesoscopic structures in Ca- and Sr-doped nano-crystalline lanthanum chromites

Calcination behavior of nano-crystalline lanthanum chromites doped with calcium and strontium has been probed by Fourier transform infrared spectroscopy, X-ray diffraction and small-angle neutron scattering as a function of temperature. Infrared spectroscopic results imply that over a range of temperatures, some intermediate phase of dopant chromates evolve and then dissolve back, which has also been confirmed by the XRD. Neutron scattering data reveal a fractal type correlation of building blocks in virgin powders. Increase in fractal dimension and reduction in upper cutoff vis-a-vis the densification of agglomerates were found with increasing calcination temperature. Calcination, beyond 900 {sup o}C, results in breaking down of the fractal morphology almost completely. Such shrinkage event also results in a modification of the microscopic structure. These changes have been attributed to the compaction of agglomerates of both Ca- and Sr-doped lanthanum chromites, assisted via liquid state sintering by the melting of the intermediate phases at intermediate calcination stages. -- Graphical Abstract: Dopant chromates evolve as intermediate phases during calcination of Ca- and Sr-doped nano-crystalline lanthanum chromites at intermediate temperatures, around 900 {sup o}C, evident from infrared spectroscopy. Such an event results in a modification of the microscopic and mesoscopic structures. Display Omitted Research highlights: {yields} Meso/microscopic structures of La{sub 0.7}Ca{sub 0.3}CrO{sub 3} and La{sub 0.8}Sr{sub 0.2}CrO{sub 3} modify during calcination. {yields} Transient phases CaCrO{sub 4} and SrCrO{sub 4} appear at intermediate temperatures. {yields} Bond length, unit cell volume, etc. modify as intermediate phases evolve and extinct. {yields} Compaction of the agglomerates takes place due to liquid state assisted sintering.

36 MATERIALS SCIENCE↗

Transmission electron microscopic study of pyrochlore to defect-fluorite transition in rare-earth pyrohafnates

A structural transition in rare earth pyrohafnates, Ln{sub 2}Hf{sub 2}O{sub 7} (Ln=Y, La, Pr, Nd, Tb, Dy, Yb and Lu), has been identified. Neutron diffraction showed that the structure transforms from well-ordered pyrochloric to fully fluoritic through the lanthanide series from La to Lu with a corresponding increase in the position parameter x of the 48f (Fd3{sup Macron }m) oxygen site from 0.330 to 0.375. As evidenced by the selected area electron diffraction, La{sub 2}Hf{sub 2}O{sub 7}, Pr{sub 2}Hf{sub 2}O{sub 7} and Nd{sub 2}Hf{sub 2}O{sub 7} exhibited a well-ordered pyrocholoric structure with the presence of intense superlattice spots, which became weak and diffuse (in Dy{sub 2}Hf{sub 2}O{sub 7} and Tb{sub 2}Hf{sub 2}O{sub 7}) before disappearing completely as the series progressed towards the Lu end. High resolution electron microscopic studies showed the breakdown of the pyrochlore ordering in the form of antiphase domains resulting in diffused smoke-like superlattice spots in the case of Dy{sub 2}Hf{sub 2}O{sub 7} and Tb{sub 2}Hf{sub 2}O{sub 7}. - Graphical abstract: Transmission electron microscopic studies showed the ordered pyrochlore to defect fluorite transition in rare-earth pyrohafnates to occur via the formation of anti-phase domains to start with. Highlights: Black-Right-Pointing-Pointer Pyrochlore to fluorite structural transition in rare earth pyrohafnates. Black-Right-Pointing-Pointer La{sub 2}Hf{sub 2}O{sub 7}, Pr{sub 2}Hf{sub 2}O{sub 7} and Nd{sub 2}Hf{sub 2}O{sub 7} showed well ordered pyrochlore structure. Black-Right-Pointing-Pointer Short range ordering in Dy{sub 2}Hf{sub 2}O{sub 7} and Tb{sub 2}Hf{sub 2}O{sub 7}. Black-Right-Pointing-Pointer Break down of pyrochlore ordering due to antiphase boundaries. Black-Right-Pointing-Pointer Rest of the series showed fluoritic structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of patinas by means of microscopic techniques

Many stone-made historic buildings have a yellowish layer called 'patina' on their external surface. In some cases, it is due to the natural ageing of the stone caused by chemical-physical reactions between the surface of the stone and the environment, and in other cases it is the result of biological activity. The origin of these patinas can be also be due to ancient protective treatments. The use of organic additives, such as protein-based compounds, in lime or gypsum-based patinas is a traditional technique, which has been used in past centuries for the conservation and protection of stone materials. The thinness of the patinas ensures that microscopic techniques are irreplaceable for their analysis. Optical Microscopy, Fluorescence Microscopy, Scanning Electron Microscopy together with an Energy Dispersive X-ray Spectrometer, and Electron Microprobe are the microscopic techniques used for the characterization of these coverings, providing very useful information on their composition, texture and structure.

36 MATERIALS SCIENCE↗

Transmission and scanning electron microscope study on the secondary cyclic hardening behavior of interstitial-free steel

Strain controlled fatigue experiment was employed to evaluate automotive grade interstitial-free ferrite steel. Hundreds of grains were examined by scanning electron microscope under electron channeling contrast image technique of backscattered electron image mode for comprehensive comparison of micrographs with those taken under transmission electron microscope. The cyclic stress responses clearly revealed that rapid hardening occurs at the early stage of cycling as a result of multiplication of dislocations to develop loop patches, dipolar walls and dislocation cells at various total strain amplitudes. After primary rapid hardening, stress responses varied from being saturated to further hardening according to dislocation structure evolution at various strain amplitudes. The fatigue failure was always accompanied with further hardening including secondary hardening. The corresponding dislocation structures with the three types of hardening behaviors are discussed. Once the secondary hardening starts, dislocation cells began to develop along grain boundaries in the low strain region and then extended into grain interiors as strain amplitudes increased and cycling went on. The secondary hardening rates were found to be directly proportional to their strain amplitudes.

36 MATERIALS SCIENCE↗

Macroscopic and microscopic investigations on uniaxial ratchetting of two-phase Ti–6Al–4V alloy

The uniaxial ratchetting of Ti–6Al–4V alloy with two phases (i.e., primary hexagonal close packed (HCP) α and secondary body-centered cubic (BCC) β phases) was investigated by macroscopic and microscopic experiments at room temperature. Firstly, the effects of cyclic softening/hardening feature, applied mean stress and stress amplitude on the uniaxial ratchetting of the alloy were discussed. The macroscopic investigation of Ti–6Al–4V alloy presents obvious strain-amplitude-dependent cyclic softening, as well as a three-staged evolution curve with regard to the ratchetting strain rate. The ratchetting depends greatly on the applied mean stress and stress amplitude while the ratchetting strain increases with the increasing applied mean stress and stress amplitude. Then, the evolution of dislocation patterns and deformation twinning during the uniaxial ratchetting of two-phase Ti–6Al–4V alloy were observed using transmission electron microscopy (TEM). The microscopic observation shows that deformation twinning occurs in the primary α phase and its amount increases gradually during the uniaxial ratchetting. Simultaneously, the planar dislocation evolves from discrete lines to some dislocation nets and parallel lines with the increasing number of cycles. The deformation twinning in the primary α phase is one of main contributions to the uniaxial ratchetting of Ti–6Al–4V alloy, and should be considered in the construction of corresponding constitutive model. - Highlights: • A three-staged ratchetting occurs in the stress-controlled cyclic tests of Ti–6Al–4V alloy. • Dislocation patterns change from discrete lines to nets and parallel lines. • Deformation twinning occurs during the uniaxial ratchetting. • Both dislocation slipping and twinning are the causes of ratchetting.

36 MATERIALS SCIENCE↗

Design of a neutron microscope based on Wolter mirrors

The predominant geometry for a neutron imaging experiment is that of a pinhole camera. Here, this is primarily due to the difficulty in focusing neutrons due to the weak refractive index, which is also strongly chromatic. Proof of concept experiments demonstrated that neutron image forming lenses based on reflective Wolter mirrors can produce quantitative, high spatial resolution neutron images while also increasing the time resolution compared to the conventional pinhole camera geometry. Motivated by these results, we report the design of a neutron microscope where two Wolter mirrors replace condensing and objective lenses, in direct analogy with typical visible light microscopes. Ray tracing results indicate that this system will yield 3 µm spatial resolution images with an acquisition time of order <1 s (10 4 faster than currently possible at this spatial resolution) with a field of view of about 5 mm in diameter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an in situ ion irradiation scanning electron microscope

An in situ ion irradiation scanning electron microscope (I 3 SEM) has been developed, installed, and integrated into the Ion Beam Laboratory at Sandia National Laboratories. The I 3 SEM facility combines a field emission, variable pressure, scanning electron microscope, a 6 MV tandem accelerator, high flux low energy ion source, an 808 nm-wavelength laser, and multiple stages to control the thermal and mechanical state of the sample observed. The facility advances real-time understanding of materials evolution under combined environments at the mesoscale. As highlighted in multiple examples, this unique combination of tools is optimized for studying mesoscale material response in overlapping extreme environments, allowing for simultaneous ion irradiation, implantation, laser bombardment, conductive heating, cooling, and mechanical deformation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-neutron overlap functions for {sup 6}He from a microscopic structure model.

A fully antisymmetrized microscopic model is developed for light two-neutron halo nuclei using a hyper-spherical basis to describe halo regions. The many-body wavefunction is optimized variationally. The model is applied to {sup 6}He bound by semi realistic Minnesota nucleon-nucleon forces. The two-neutron separation energy and the radius of the halo are reproduced in agreement with experiment. Antisymmetrization effects between {sup 4}He and halo neutrons are found to be crucial for binding of {sup 6}He. We also properly extract two-neutron overlap functions and find that there is a significant increase of 30%-70% in their normalization due to microscopic effects as compared to the results of three-body models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of compact ultrafast microscopes for single- and multi-shot imaging with MeV electrons

Ultrafast high-energy electron microscopy, taking advantage of strong interaction of electrons with matter while minimizing space charge problems, can be used to address a wide range of grand challenges in basics energy sciences. However, MeV-electron lenses are inherently bulky and expensive, preventing them from acceptance in a broad scientific community. In this article, we report our novel design of a compact, low-cost imaging-lens system for MeV-electrons based on quadrupole multiplets, including triplet, quadruplet and quintuplet, both symmetric and asymmetric. We compare optical performance of quadrupole-based condenser, objective and projector lenses with that of the traditional round-lenses and discuss the strategy for their practical use in constructing MeV-electron microscopes for high spatial and temporal resolution single- and multi-shot imaging. Combining the compound electron-optical system with a photocathode radiofrequency (RF) gun, such a MeV electron microscope can be fit into a smallsized laboratory for ultrafast observations and measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Resolution of the Electron Microscope at the Atomic Scale

The importance of atomic-resolution electron microscopy as a tool for structure analysis lies in its ability to produce images in which each peak corresponds to the position of an atom (or atomic column) within the specimen. Being able to distinguish between atoms (or columns) that appear close together when projected in the chosen viewing direction depends on the resolution of the microscope. Knowledge of the resolution of any particular electron microscope is crucial to judge if its resolution is appropriate for the specimen. In addition, resolution quality will determine the precision of measured atom positions.

A-OK↗

Humidity Exposure Enhances Microscopic Mobility in a Room-Temperature Ionic Liquid in MXene

Present and future electrochemical devices employing advanced electrode and electrolyte materials are expected to operate in diverse environments, where they are exposed to variable conditions, such as changing humidity levels. Such conditions can possibly alter the microscopic mechanisms that influence the electrochemical performance. Here in this paper, using quasi-elastic neutron scattering and molecular dynamics simulations, we investigate the influence of humidity exposure on a room-temperature ionic liquid, [EMIm + ][Tf 2 N – ], in Ti 3 C 2 T x MXene. Absorbed water enhances the microscopic mobility of confined [EMIm + ][Tf 2 N – ], even though the ionic liquid itself is not very hygroscopic. The absorbed water molecules predominantly reside on the termination groups of the more hydrophilic MXene layers, thereby displacing the ions from the surface and facilitating their motions in the MXene matrix.

36 MATERIALS SCIENCE↗

Microscopic Dynamics in an Ionic Liquid Augmented with Organic Solvents

We introduce the complex microscopic dynamics of 1-butyl-3-methyl-imidazolium bis(trifluromethylsulfonyl)imide, [Bmim + ][TFSI – ], ionic liquid mixed with organic solvents to improve its properties for energy storage applications. To probe the microscopic dynamics on different length and time scales, we have used different neutron scattering spectrometers for quasielastic neutron scattering measurements to compare the effects of solvation in several organic solvents with nearly the same dipole moment but broadly varying bulk diffusivity. The ionic liquid–solvent mixtures show a nanoscopic phase separation into an ionic liquid-rich and a solvent-rich phase, as revealed by the model-free dynamic susceptibility data and further corroborated by the cluster histogram analysis of molecular dynamics (MD) simulation. In both phases, we observe a long-range translational mobility of the [Bmim + ] cation, which scales with the bulk diffusivities of the organic solvents; this correlation becomes stronger in the solvent-rich phase. Furthermore, various localized motion modes of the [Bmim + ] cation are observed. A combination of neutron scattering and MD simulations reveals the parameters governing solvent-controlled diffusivity in an ionic liquid, which helps formulate new electrolytes optimized for effective energy storage devices.

25 ENERGY STORAGE↗

Quantitative Measurements of the Temperature-Dependent Microscopic and Macroscopic Dynamics of a Molecular Dopant in a Conjugated Polymer

Understanding the nature of dopant dynamics in the solid state is critical for improving the longevity and stability of organic electronic devices and for optimizing the doping-induced solubility control (DISC) patterning method. Here in this work, we use quasi-elastic neutron scattering (QENS) and fluorescence quenching techniques to develop a comprehensive picture of both the microscopic and macroscopic dynamics of the soluble p-type molecular dopant tetrafluoromethyloxycarbonyltricyanoquinodimethane (F4MCTCNQ) in the conductive polymer poly(3-hexylthiophene-2,5-diyl) (P3HT). Specifically, fast dynamics (ps–ns) of the dopant, such as the methyl and the methoxycarbonyl group rotations, are observed in QENS experiments. From confocal fluorescence microscope experiments, longer-range/slower dopant diffusion (ms–days) is captured. However, in order to fit these data, it is necessary to incorporate a Langmuir isotherm equilibrium between the neutral and ionized dopant molecules. Ionized F4MCTCNQ is strongly favored by the equilibrium, but it diffuses 3 orders of magnitude slower than neutral species. Moreover, the macroscopic diffusion is found to depend mostly on the minority concentration of neutral dopant molecules in the film. In conclusion, the global diffusion coefficient of the monoester-substituted dopant F4MCTCNQ is shown to be more than an order of magnitude smaller than that of the widely used dopant F4TCNQ.

36 MATERIALS SCIENCE↗