Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo Simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Kinetic Monte Carlo simulations of structural evolution during anneal of additively manufactured materials

Our experiments indicated that upon a post-processing anneal, an additively manufactured 316L stainless steel exhibits cubic grains rather than the conventional equiaxed grains. In this work, we have used kinetic Monte Carlo simulations to explore the origin of these cubic grains. First, we implemented a new kinetic Monte Carlo model in parallel code SPPARKS to simulate grain growth and recrystallization under a residual energy distribution. Our model incorporates physical properties and real-time, as opposed to generic properties and relative time. We further validated that our SPPARKS simulations reproduced the expected kinetic behavior of single-grain evolution. We then used the validated approach to simulate the anneal of an additively manufactured material under the same conditions used in our experiments. We found that the cubic grains can origin from a periodically varying residual energy that may be present in additively manufactured materials.

36 MATERIALS SCIENCE↗

MO-A-BRD-10: A Fast and Accurate GPU-Based Proton Transport Monte Carlo Simulation for Validating Proton Therapy Treatment Plans

Purpose: To build a GPU-based Monte Carlo (MC) simulation of proton transport with detailed modeling of elastic and non-elastic (NE) protonnucleus interactions, for use in a very fast and cost-effective proton therapy treatment plan verification system. Methods: Using the CUDA framework, we implemented kernels for the following tasks: (1) Simulation of beam spots from our possible scanning nozzle configurations, (2) Proton propagation through CT geometry, taking into account nuclear elastic and multiple scattering, as well as energy straggling, (3) Bertini-style modeling of the intranuclear cascade stage of NE interactions, and (4) Simulation of nuclear evaporation. To validate our MC, we performed: (1) Secondary particle yield calculations in NE collisions with therapeutically-relevant nuclei, (2) Pencil-beam dose calculations in homogeneous phantoms, (3) A large number of treatment plan dose recalculations, and compared with Geant4.9.6p2/TOPAS. A workflow was devised for calculating plans from a commercially available treatment planning system, with scripts for reading DICOM files and generating inputs for our MC. Results: Yields, energy and angular distributions of secondaries from NE collisions on various nuclei are in good agreement with the Geant4.9.6p2 Bertini and Binary cascade models. The 3D-gamma pass rate at 2%–2mm for 70–230 MeV pencil-beam dose distributions in water, soft tissue, bone and Ti phantoms is 100%. The pass rate at 2%–2mm for treatment plan calculations is typically above 98%. The net computational time on a NVIDIA GTX680 card, including all CPU-GPU data transfers, is around 20s for 1×10{sup 7} proton histories. Conclusion: Our GPU-based proton transport MC is the first of its kind to include a detailed nuclear model to handle NE interactions on any nucleus. Dosimetric calculations demonstrate very good agreement with Geant4.9.6p2/TOPAS. Our MC is being integrated into a framework to perform fast routine clinical QA of pencil-beam treatment plans. Hardware for such a system will cost under $5000. This work was funded in part by a grant from Varian Medical Systems, Inc.

61 RADIATION PROTECTION AND DOSIMETRY↗

Status of the Space Radiation Monte Carlos Simulation Based on FLUKA and ROOT

The NASA-funded project reported on at the first IWSSRR in Arona to develop a Monte-Carlo simulation program for use in simulating the space radiation environment based on the FLUKA and ROOT codes is well into its second year of development, and considerable progress has been made. The general tasks required to achieve the final goals include the addition of heavy-ion interactions into the FLUKA code and the provision of a ROOT-based interface to FLUKA. The most significant progress to date includes the incorporation of the DPMJET event generator code within FLUKA to handle heavy-ion interactions for incident projectile energies greater than 3GeV/A. The ongoing effort intends to extend the treatment of these interactions down to 10 MeV, and at present two alternative approaches are being explored. The ROOT interface is being pursued in conjunction with the CERN LHC ALICE software team through an adaptation of their existing AliROOT software. As a check on the validity of the code, a simulation of the recent data taken by the ATIC experiment is underway.

Andersen, Victor↗

Simulation of Auger electron emission from nanometer-size gold targets using the Geant4 Monte Carlo simulation toolkit

We report that a revised atomic deexcitation framework for the Geant4 general purpose Monte Carlo toolkit capable of simulating full Auger deexcitation cascades was implemented in June 2015 release (version 10.2 Beta). An overview of this refined framework and testing of its capabilities is presented for the irradiation of gold nanoparticles (NP) with keV photon and MeV proton beams. The resultant energy spectra of secondary particles created within and that escape the NP are analyzed and discussed. It is anticipated that this new functionality will improve and increase the use of Geant4 in the medical physics, radiobiology, nanomedicine research and other low energy physics fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo simulation of nonadiabatic expansion in cometary atmospheres - Halley

Monte Carlo methods developed for the characterization of velocity-dependent collision processes and ballistic transports in planetary exospheres form the basis of the present computer simulation of icy comet atmospheres, which iteratively undertakes the simultaneous determination of velocity distribution for five neutral species (water, together with suprathermal OH, H2, O, and H) in a flow regime varying from the hydrodynamic to the ballistic. Experimental data from the neutral mass spectrometer carried by Giotto for its March, 1986 encounter with Halley are compared with a model atmosphere.

Hodges, R. Richard, Jr.↗

Velocity-Space Hybridization of Direct Simulation Monte Carlo and a Quasi-Particle Boltzmann Solver

This paper presents a new method for modeling rarefied gas flows based on hybridization of direct simulation Monte Carlo (DSMC) and discrete velocity method (DVM)-based quasi-particle representations of the velocity distribution function. It is aimed at improving the resolution of the tails of the distribution function (compared with DSMC) and computational efficiency (compared with DVM). Details of the method, such as the collision algorithm and the particle merging scheme, are discussed. The hybrid approach is applied to the study of noise in a Maxwellian distribution, computation of electron-impact ionization rate coefficient, as well as numerical simulation of a supersonic Couette flow. The hybrid-based solver is compared with pure DSMC and DVM approaches in terms of accuracy, computational speed, and memory use. It is shown that such a hybrid approach can provide a lower computational cost than a pure DVM approach, while being able to retain accuracy in modeling high-velocity tails of the distribution function. For problems where trace species have a significant impact on the flow physics, the proposed method is shown to be capable of providing better computational efficiency and accuracy compared with standard fixed-weight DSMC.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement and Monte Carlo simulation of 3D neutrons distribution in a radiotherapy bunker - 25411

Different methods exist to verify bunkers design for radiation therapy medical facilities; analytical methods based on simplified equations and Monte Carlo methods. One of the main purposes of this work is to present the advantages of using Monte Carlo simulation to verify radiotherapy bunker shielding design. This methodology is more accurate and characterizes not only the fluence and dose three-dimensionally, but also the energy spectrum of particles generated by the Linac. The other main purpose of the work is to analyze the importance of the generated photoneutrons when the Linac emits photon beams of high energy (above 8 MeV), since numerous studies have found that they can expose the patient and clinical staff to non-negligible dose. The main novelty introduced by this work, is the creation of more realistic simulation models to represent the radiotherapy facility by using CAD and meshes technologies. Results obtained using these bunker simulation models have been validated experimentally at the Hospital Universitari i Politecnic La Fe de Valencia facilities using two different neutron detectors; the neutron meter LB 6411 (designed between Berthold and Karlsruhe Research Center) and neutron detector model 42 - 41L (Ludlum, Prescila). Results obtained with Monte Carlo and those measured experimentally fit correctly, validating this analysis methodology. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of clinical IMRT treatment planning using the GATE Monte Carlo simulation platform for absolute and relative dose calculations

Purpose: The objective of this study was to evaluate and validate the use of the Geant4 application for emission tomography (GATE) Monte Carlo simulation platform for clinical intensity modulated radiotherapy (IMRT) dosimetry studies. Methods: The first step consisted of modeling a 6 MV photon beam linear accelerator (LINAC), with its corresponding validation carried out using percent depth dose evaluation, transverse profiles, tissue phantom ratio, and output factor on water phantom. The IMRT evaluation was performed by comparing simulation and measurements in terms of absolute and relative doses using IMRT dedicated quality assurance phantoms considering seven different patient datasets. Results: Concerning the LINAC simulated model validation tissue phantom ratios at 20 and 10 cm in water TPR{sub 10}{sup 20} obtained from GATE and measurements were 0.672 {+-} 0.063 and 0.675, respectively. In terms of percent depth dose and transverse profiles, error ranges were, respectively: 1.472%{+-} 0.285% and 4.827%{+-} 1.323% for field size of 4 Multiplication-Sign 4, 5 Multiplication-Sign 5, 10 Multiplication-Sign 10, 15 Multiplication-Sign 15, 20 Multiplication-Sign 20, 25 Multiplication-Sign 25, 30 Multiplication-Sign 30, and 40 Multiplication-Sign 40 cm{sup 2}. Most errors were observed at the edge of radiation fields because of higher dose gradient in these areas. Output factors showed good agreement between simulation and measurements with a maximum error of 1.22%. Finally, for IMRT simulations considering seven patient datasets, GATE provided good results with a relative error of 0.43%{+-} 0.25% on absolute dose between simulated and measured beams (measurements at the isocenter, volume 0.125 cm{sup 3}). Planar dose comparisons were also performed using gamma-index analysis. For the whole set of beams considered the mean gamma-index value was 0.497 {+-} 0.152 and 90.8%{+-} 3.6% of the evaluated dose points satisfied the 5%/ 4 mm criterion. Conclusions: These results show that GATE allows reliable simulation of complex beams in radiotherapy after an accurate LINAC modeling is validated. A simple cross-calibration procedure proposed in this work allows obtaining absolute dose values even in complex fields.

60 APPLIED LIFE SCIENCES↗

SU-F-T-658: Out-Of-Field Dose Comparison for TrueBeam Low Energy Beams for Extended Distances: Measurement Vs Monte Carlo Simulation

Purpose: Patient dose far from the treatment field is comprised of scatter from within the patient, and treatment head leakage. We quantify the treatment head leakage for TrueBeam linear accelerator for 6X and 6X-FFF beams by comparing measurements to Monte Carlo simulations for a variety of jaw sizes and collimator rotations. This work is conceptually similar to that of Kry et al. (Medical Physics 2006; 33: 4405), who considered a Clinac linear accelerator. Methods: Measurements were made using an EXRADIN A101 ion chamber positioned in the patient plane, at distances up to 100 cm from isocenter. Simulations were done using VirtuaLinac, the GEANT4-based Monte Carlo model of the TrueBeam treatment head, and an in-house (U. Virginia) GEANT4-based code. In-house code modelled an ion chamber with build-up, based on a CT scan of the chamber. VirtuaLinac included a detailed model of the treatment head shielding, and was run on the Amazon Web Services cloud to generate spherical phase space files surrounding the treatment head. These phase space files were imported into the in-house code. Results: Initial comparisons between measurements and simulation showed an excess of dose in the in-plane direction, away from the gantry, in the simulations. This was traced to an incomplete model of the shielding—specifically, the component holding the primary collimator was smaller in the model than in the TrueBeam. Modifications were made to VirtuaLinac to more closely match the engineering drawings. In the in-plane direction, the lowest out of field dose was away from gantry (negative abscissa values) at around 60 cm from isocenter, for fields smaller than 10×10 cm2. Out of field dose decreased with decreasing jaw size. Flattening-filter free beam produced out-of-field doses as low as 65% of those with flattened beam. Conclusion: Doses determined from simulation and measurement were in close agreement. Funding support from the Jefferson Trust Foundation.

60 APPLIED LIFE SCIENCES↗

WE-D-BRF-01: FEATURED PRESENTATION - Investigating Particle Track Structures Using Fluorescent Nuclear Track Detectors and Monte Carlo Simulations

Purpose: To report on the efforts funded by the AAPM seed funding grant to develop the basis for fluorescent nuclear track detector (FNTD) based radiobiological experiments in combination with dedicated Monte Carlo simulations (MCS) on the nanometer scale. Methods: Two confocal microscopes were utilized in this study. Two FNTD samples were used to find the optimal microscope settings, one FNTD irradiated with 11.1 MeV/u Gold ions and one irradiated with 428.77 MeV/u Carbon ions. The first sample provided a brightly luminescent central track while the latter is used to test the capabilities to observe secondary electrons. MCS were performed using TOPAS beta9 version, layered on top of Geant4.9.6p02. Two sets of simulations were performed, one with the Geant4-DNA physics list and approximating the FNTDs by water, a second set using the Penelope physics list in a water-approximated FNTD and a aluminum-oxide FNTD. Results: Within the first half of the funding period, we have successfully established readout capabilities of FNTDs at our institute. Due to technical limitations, our microscope setup is significantly different from the approach implemented at the DKFZ, Germany. However, we can clearly reconstruct Carbon tracks in 3D with electron track resolution of 200 nm. A second microscope with superior readout capabilities will be tested in the second half of the funding period, we expect an improvement in signal to background ratio with the same the resolution.We have successfully simulated tracks in FNTDs. The more accurate Geant4-DNA track simulations can be used to reconstruct the track energy from the size and brightness of the observed tracks. Conclusion: We have achieved the goals set in the seed funding proposal: the setup of FNTD readout and simulation capabilities. We will work on improving the readout resolution to validate our MCS track structures down to the nanometer scales.

60 APPLIED LIFE SCIENCES↗

Extended kinetic lattice grand canonical Monte Carlo simulation method for transport of multicomponent ion mixtures through a model nanopore system

Abstract An extended version of the original kinetic lattice grand canonical Monte Carlo simulation method combined with mean field theory (KLGCMC/MF) ( J. Chem. Phys. 2007 , 127, 024706) is presented for the study of transport of multicomponent ion mixtures through a model nanopore. Comparison of the extended KLGCMC/MF (eKLGCMC/MF) simulation results with Poisson–Nernst–Planck (PNP) calculations is also made to confirm the validity of the extended simulation approach. Unlike the original version of KLGCMC/MF simulation method that treats only a binary ionic solution with one cation and one anion species, this extended version can deal with a system that includes ternary ion mixtures. A diffusion probability algorithm is also added to the extended version of the simulation method to describe the inhomogeneous diffusivity of ions that is often observed in the ion permeation through nanopores. Both Legendre and Chebyshev polynomials of the second kind were tested as a basis set for the basis set expansion (BSE) method with which to calculate the reaction field energy in the eKLGCMC/MF simulation. It turned out that the Legendre polynomials perform better than the Chebyshev polynomials, and as a result, the Legendre polynomials were implemented in the current version of eKLGCMC/MF simulation algorithm. The presented eKLGCMC/MF simulation method with new features finds its potential applications in nanopore systems where the correlation between ion species with the same sign of charges plays a key role such as oscillating ion currents or anomalous mole fraction effects.

Choi, Inhyeok↗

A Method to Alleviate the Long History Problem Encountered in Monte Carlo Simulations via Weight Window Variance Reduction

When the weight window is implemented in large and complex models, streaming path and deep penetration could lead to a long history problem that takes a disproportionate amount of time for the accomplishment of Monte Carlo simulations and exerts a detrimental effect on the efficiency of parallel computing. An approach set the limitation of weight window splitting was proposed for the alleviation of long history problem. Tests were conducted on a streaming dog-leg geometry model and a 3D model of the Chinese Fusion Engineering Testing Reactor. The results show that a suitable parameter in the alleviation method could optimize both the performance of variance reduction and the efficiency of parallel calculation, which makes long history problem tractable.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Kinetic Monte Carlo Simulations and Molecular Conductance Measurements of the Bacterial Decaheme Cytochrome MtrF

Microorganisms overcome the considerable hurdle of respiring extracellular solid substrates by deploying large multiheme cytochrome complexes that form 20 nanometer conduits to traffic electrons through the periplasm and across the cellular outer membrane. Here we report the first kinetic Monte Carlo simulations and single-molecule scanning tunneling microscopy (STM) measurements of the Shewanella oneidensis MR-1 outer membrane decaheme cytochrome MtrF, which can perform the final electron transfer step from cells to minerals and microbial fuel cell anodes. We find that the calculated electron transport rate through MtrF is consistent with previously reported in vitro measurements of the Shewanella Mtr complex, as well as in vivo respiration rates on electrode surfaces assuming a reasonable (experimentally verified) coverage of cytochromes on the cell surface. The simulations also reveal a rich phase diagram in the overall electron occupation density of the hemes as a function of electron injection and ejection rates. Single molecule tunneling spectroscopy confirms MtrF's ability to mediate electron transport between an STM tip and an underlying Au(111) surface, but at rates higher than expected from previously calculated heme-heme electron transfer rates for solvated molecules.

cytochrome mtrf↗

MONTE CARLO SIMULATIONS OF THE PHOTOSPHERIC EMISSION IN GAMMA-RAY BURSTS

We studied the decoupling of photons from ultra-relativistic spherically symmetric outflows expanding with constant velocity by means of Monte Carlo simulations. For outflows with finite widths we confirm the existence of two regimes: photon-thick and photon-thin, introduced recently by Ruffini et al. (RSV). The probability density function of the last scattering of photons is shown to be very different in these two cases. We also obtained spectra as well as light curves. In the photon-thick case, the time-integrated spectrum is much broader than the Planck function and its shape is well described by the fuzzy photosphere approximation introduced by RSV. In the photon-thin case, we confirm the crucial role of photon diffusion, hence the probability density of decoupling has a maximum near the diffusion radius well below the photosphere. The time-integrated spectrum of the photon-thin case has a Band shape that is produced when the outflow is optically thick and its peak is formed at the diffusion radius.

79 ASTRONOMY AND ASTROPHYSICS↗

EAS accompanied by gamma-families at Mt. Norikura and comparison with Monte Carlo simulation

The experimental data of extensive air showers (EAS) accompanied by gamma-families, with total energy greater than 10 TeV, were compared with a Monte Carlo simulation with a rising cross section proportional to E sup 0.04 for the p-air inelastic cross section. It is found that the absolute intensity of size spectrum of such EAS is strongly affected by the primary protons intensity at 10 to the 15th power approx. 10 to the 16th power eV region and the experimental size spectrum agrees with the simulated spectra for the p-poor primary composition better than the p-rich one.

Shima, M.↗

Monte Carlo simulation of a new gamma ray telescope

A new Monte Carlo code has been written to simulate the response of the new University of California double scatter gamma ray telescope. This package of modular software routines, written in VAX FORTRAN 77 simulates the detection of 0.1 to 35 MeV gamma rays. The new telescope is flown from high altitude balloons to measure medium energy gamma radiation from astronomical sources. This paper presents (1) the basic physics methods in the code, and (2) the predicted response functions of the telescope. Gamma ray processes include Compton scattering, pair production and photoelectric absorption in plastic scintillator, NaI(Tl) and aluminum. Electron transport processes include ionization energy loss, multiple scattering, production of bremsstrahlung photons and positron annihilation.

Simone, J.↗

Radiative interactions in chemically reacting compressible nozzle flows using Monte Carlo simulations

The two-dimensional spatially elliptic Navier-Stokes equations have been used to investigate the radiative interactions in chemically reacting compressible flows of premixed hydrogen and air in an expanding nozzle. The radiative heat transfer term in the energy equation is simulated using the Monte Carlo method (MCM). The nongray model employed is based on the statistical narrow band model with an exponential-tailed inverse intensity distribution. The spectral correlation has been considered in the Monte Carlo formulations. Results obtained demonstrate that the effect of radiation on the flow field is minimal but its effect on the wall heat transfer is significant. Extensive parametric studies are conducted to investigate the effects of equivalence ratio, wall temperature, inlet flow temperature, and the nozzle size on the radiative and conductive wall fluxes.

Liu, J.↗

SU-F-T-30: Comprehensive Dosimetric Characterization of the Novel Direction Modulation Brachytherapy (DMBT) Tandem Applicator Using Monte Carlo Simulations

Purpose: To characterize the dosimetric properties/distributions of the novel proposed direction modulated brachytherapy (DMBT) tandem applicator in combination with 192Ir HDR source, and compare against conventional tandem design, using Monte Carlo simulations. Methods: The proposed DMBT tandem applicator is designed for image-guided adaptive brachytherapy, especially MRI, of cervical cancer. It has 6 peripheral holes of 1.3-mm width, grooved along a 5.4-mm diameter nonmagnetic tungsten alloy rod of density 18.0 g/cc, capable of generating directional dose profiles – leading to enhanced dose sculpting capacity through inverse planning. In-water dosimetric parameters for the DMBT and conventional tandems have been calculated for various radial distances away and around the tandems. For the DMBT tandem, the cumulative dose from the 192Ir source occupying 1) one and 2) all six holes in equal dwell times was calculated and normalized to match the dose rate of the open source (in conventional tandem) at 1 cm from the center. This is done to compare and contrast the characteristic dose distributions to that of the isotropic TG43-based 192Ir source. Results: All dose rates were normalized at 1-cm radius from the center of the applicators, containing source(s). The normalized dose rates at 0.5, 3.0, and 5.0-cm radiuses were then 388, 11.3, and 4.1% for conventional tandem, 657, 8.1, and 2.7% for DMBT tandem with the source in one hole at front entrance, and 436, 10.9, and 3.8% for DMBT tandem with the source in all six holes. For the DMBT tandem case with the source in one hole, the backside transmissions were 47, 2.4, and 0.9%, respectively. Conclusion: The DMBT tandem is able to generate closely similar dosimetric characteristics as that of the single-channel conventional tandem if needed (with the source occupying all six holes), at the same time, generate directional radiation profile(s) for favorably enabling 3D dose sculpting capability.

60 APPLIED LIFE SCIENCES↗