Search NASA⌕ Search

SEARCH · Search NASA

Results for “Motion Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

The potential of positron emission tomography for intratreatment dynamic lung tumor tracking: A phantom study

Purpose: This study aims to evaluate the potential and feasibility of positron emission tomography for dynamic lung tumor tracking during radiation treatment. The authors propose a center of mass (CoM) tumor tracking algorithm using gated-PET images combined with a respiratory monitor and investigate the geometric accuracy of the proposed algorithm. Methods: The proposed PET dynamic lung tumor tracking algorithm estimated the target position information through the CoM of the segmented target volume on gated PET images reconstructed from accumulated coincidence events. The information was continuously updated throughout a scan based on the assumption that real-time processing was supported (actual processing time at each frame ≈10 s). External respiratory motion and list-mode PET data were acquired from a phantom programmed to move with measured respiratory traces (external respiratory motion and internal target motion) from human subjects, for which the ground truth target position was known as a function of time. The phantom was cylindrical with six hollow sphere targets (10, 13, 17, 22, 28, and 37 mm in diameter). The measured respiratory traces consisted of two sets: (1) 1D-measured motion from ten healthy volunteers and (2) 3D-measured motion from four lung cancer patients. The authors evaluated the geometric accuracy of the proposed algorithm by quantifying estimation errors (Euclidean distance) between the actual motion of targets (1D-motion and 3D-motion traces) and CoM trajectories estimated by the proposed algorithm as a function of time. Results: The time-averaged error of 1D-motion traces over all trajectories of all targets was 1.6 mm. The error trajectories decreased with time as coincidence events were accumulated. The overall error trajectory of 1D-motion traces converged to within 2 mm in approximately 90 s. As expected, more accurate results were obtained for larger targets. For example, for the 37 mm target, the average error over all 1D-motion traces was 1.1 mm; and for the 10 mm target, the average error over all 1D-motion traces was 2.8 mm. The overall time-averaged error of 3D-motion traces was 1.6 mm, which was comparable to that of the 1D-motion traces. There were small variations in the errors between the 3D-motion traces, although the motion trajectories were very different. The accuracy of the estimates was consistent for all targets except for the smallest. Conclusions: The authors developed an algorithm for dynamic lung tumor tracking using list-mode PET data and a respiratory motion signal, and demonstrated proof-of-principle for PET-guided lung tumor tracking. The overall tracking error in phantom studies is less than 2 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-128: Dosimetric Impact of Esophagus Motion in Spine Stereotactic Body Radiotherapy

Purpose: Acute esophageal toxicity is a common side effect in spine stereotactic body radiotherapy (SBRT). The respiratory motion may alter esophageal position from the planning scan resulting in excessive esophageal dose. Here we assessed the dosimetric impact resulting from the esophageal motion using 4DCT. Methods: Nine patients treated to their thoracic spines in one fraction of 24 Gy were identified for this study. The original plan on a free breathing CT was copied to each phase image of a 4DCT scan, recalculated, scaled, and accumulated to the free breathing CT using deformable image registration. A segment of esophagus was contoured in the vicinity of treatment target. Esophagus dose volume histogram (DVH) was generated for both the original planned dose and the accumulated 4D dose for comparison. In parallel, we performed a chained deformable registration of 4DCT phase images to estimate the motion magnitude of the esophagus in a breathing cycle. We examined the correlation between the motion magnitude and the dosimetric deviation. Results: The esophageal motion mostly exhibited in the superior-inferior direction. The cross-sectional motion was small. Esophagus motion at T1 vertebra level (0.7 mm) is much smaller than that at T11 vertebra level (6.5 mm). The difference of Dmax between the original and 4D dose distributions ranged from 9.1 cGy (esophagus motion: 5.6 mm) to 231.1 cGy (esophagus motion: 3.1 mm). The difference of D(5cc) ranged from 5 cGy (esophagus motion: 3.1 mm) to 85 cGy (esophagus motion: 3.3 mm). There was no correlation between the dosimetric deviation and the motion magnitude. The V(11.9Gy)<5cc constraint was met for each patient when examining the DVH calculated from the 4D dose. Conclusion: Respiratory motion did not result in substantial dose increase to esophagus in spine SBRT. 4DCT simulation may not be necessary with regards to esophageal dose assessment.

60 APPLIED LIFE SCIENCES↗

The Viability of Trajectory Analysis for Diagnosing Dynamical and Chemical Influences on Ozone Concentrations in the UTLS

The viability of trajectory analysis for diagnosing the interplay between chemistry and dynamics is investigated by comparing ozone mixing ratios modelled using air-parcel pathways to values observed along flight tracks during ATTREX (Airborne Tropical TRopopause EXperiment). Trajectories are initiated at the locations of ozone observations and tracked backward in time to their sources at termini of backward trajectories. The modelled values of ozone utilize 3-dimensional analysis fields from WACCM (Whole Atmosphere Community Climate Model) (a chemical-climate model with dynamical fields nudged towards MERRA (Modern-Era Retrospective Analysis and Research Applications) reanalysis) and ERA-interim (product of ECMWF - the European Centre for Medium-Range Weather Forecasts) to determine source mixing ratios with chemical production and loss terms derived from the ozone chemistry used in WACCM. A statistical base of modelled ozone is constructed with 6 trajectory platforms (adiabatic, diabatic, and kinematic forced by ERA-interim and MERRA), two chemical models (WACCM chemistry and no chemistry), and 4 trajectory lengths (5, 10, 20, and 30 days). Linear regression is employed to separate systematic errors from random errors and to characterize the impact of source mixing ratios, path length, vertical motion, and chemistry on modelled ozone errors. Errors in the analysis ozone fields are large, if not dominant, contributors to model error. Random errors are particularly large for point-by-point comparisons, however averaging over 800 km (75 minutes) flight segments substantially reduces random error and exposes systematic errors. Of the two analysis ozone data sets, WACCM, which incorporates detailed chemistry, provides the smaller systematic errors while ERA-interim, which has crude chemistry but assimilates observational data, has the smaller random errors. Of the different trajectory platforms, adiabatic calculations produce the smaller random errors (irrespective of the use of chemistry) but both vertical motion and chemistry are required to optimally reduce systematic errors. These results suggest that meaningful analysis of dynamical and chemical interactions that control ozone mixing ratios are viable on spatial scales larger than a few reanalysis grid spaces, that errors in the analyzed ozone data sets are large but not prohibitively so, and that vertical velocities and heating rates from reanalysis data, while problematic, contain useful information [on the ozone concentrations in the UTLS (Upper Troposphere/Lower Stratosphere)].

ozone↗

Specificities of Local Dynamics and Orientational State of Rigid-Chain Liquid-Crystal Polymers

Proton magnetic resonance (PMR) spectra and terahertz IR spectra of Vectra A950 fibers and granules and Armos fibers before and after heat treatment were obtained and analyzed in order to understand the molecular mobility mechanisms that ensure the self-organization and restructurization of these rigid-chain liquid-crystal polymers, as well as their similarity and difference. It is shown that large-scale thermal (quasi-segmental) mobility in such LC polymers is due to the reptation of macromolecules with respect to each other and the conformational transitions necessary for the motion of chains in them are the result of random accumulation of displacements that occur during local bending and torsional-vibrational movements in the links of polymer chains according to the Bresler–Frenkel mechanism.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The reliability and validity of flight task workload ratings

Twelve instrument-rated general aviation pilots each flew two scenarios in a motion-base simulator. During each flight, the pilots verbally estimated their workload every three minutes. Following each flight, they again estimated workload for each flight segment and also rated their overall workload, perceived performance, and 13 specific factors on a bipolar scale. The results indicate that time (a priori, inflight, or postflight) of eliciting ratings, period to be covered by the ratings (a specific moment in time or a longer period), type of rating scale, and rating method (verbal, written, or other) may be important variables. Overall workload ratings appear to be predicted by different specific scales depending upon the situation, with activity level the best predictor. Perceived performance seems to bear little relationship to observer-rated performance when pilots rate their overall performance and an observer rates specific behaviors. Perceived workload and performance also seem unrelated.

Childress, M. E.↗

The KALI multi-arm robot programming and control environment

The KALI distributed robot programming and control environment is described within the context of its use in the Jet Propulsion Laboratory (JPL) telerobot project. The purpose of KALI is to provide a flexible robot programming and control environment for coordinated multi-arm robots. Flexibility, both in hardware configuration and software, is desired so that it can be easily modified to test various concepts in robot programming and control, e.g., multi-arm control, force control, sensor integration, teleoperation, and shared control. In the programming environment, user programs written in the C programming language describe trajectories for multiple coordinated manipulators with the aid of KALI function libraries. A system of multiple coordinated manipulators is considered within the programming environment as one motion system. The user plans the trajectory of one controlled Cartesian frame associated with a motion system and describes the positions of the manipulators with respect to that frame. Smooth Cartesian trajectories are achieved through a blending of successive path segments. The manipulator and load dynamics are considered during trajectory generation so that given interface force limits are not exceeded.

Backes, Paul↗

An Automated SVD for Alignment and Control of James Webb Space Telescope Mirrors

The James Webb Space Telescope (JWST) is a three-mirror anastigmatic telescope. The alignment of the segmented primary and secondary mirrors in the wavefront sensing and control process involves a series of actuators to control the six degrees-of-freedom motion on each surface in addition to the radius of curvature. The control matrix developed from the alignment parameters is over-determined and singular value decomposition (SVD) method is used to solve it in the least square sense. An automated SVD scheme has been developed to identify the most contributing modes in a typical alignment process and reduce the impact of error-prone modes from the control process.

Shiri, Sharam↗

Moving metal artifact reduction in cone-beam CT scans with implanted cylindrical gold markers

Purpose: Implanted gold markers for image-guided radiotherapy lead to streaking artifacts in cone-beam CT (CBCT) scans. Several methods for metal artifact reduction (MAR) have been published, but they all fail in scans with large motion. Here the authors propose and investigate a method for automatic moving metal artifact reduction (MMAR) in CBCT scans with cylindrical gold markers. Methods: The MMAR CBCT reconstruction method has six steps. (1) Automatic segmentation of the cylindrical markers in the CBCT projections. (2) Removal of each marker in the projections by replacing the pixels within a masked area with interpolated values. (3) Reconstruction of a marker-free CBCT volume from the manipulated CBCT projections. (4) Reconstruction of a standard CBCT volume with metal artifacts from the original CBCT projections. (5) Estimation of the three-dimensional (3D) trajectory during CBCT acquisition for each marker based on the segmentation in Step 1, and identification of the smallest ellipsoidal volume that encompasses 95% of the visited 3D positions. (6) Generation of the final MMAR CBCT reconstruction from the marker-free CBCT volume of Step 3 by replacing the voxels in the 95% ellipsoid with the corresponding voxels of the standard CBCT volume of Step 4. The MMAR reconstruction was performed retrospectively using a half-fan CBCT scan for 29 consecutive stereotactic body radiation therapy patients with 2–3 gold markers implanted in the liver. The metal artifacts of the MMAR reconstructions were scored and compared with a standard MAR reconstruction by counting the streaks and by calculating the standard deviation of the Hounsfield units in a region around each marker. Results: The markers were found with the same autosegmentation settings in 27 CBCT scans, while two scans needed slightly changed settings to find all markers automatically in Step 1 of the MMAR method. MMAR resulted in 15 scans with no streaking artifacts, 11 scans with 1–4 streaks, and 3 scans with severe streaking artifacts. The corresponding numbers for MAR were 8 (no streaks), 1 (1–4 streaks), and 20 (severe streaking artifacts). The MMAR method was superior to MAR in scans with more than 8 mm 3D marker motion and comparable to MAR for scans with less than 8 mm motion. In addition, the MMAR method was tested on a 4D CBCT reconstruction for which it worked equally well as for the 3D case. The markers in the 4D case had very low motion blur. Conclusions: An automatic method for MMAR in CBCT scans was proposed and shown to effectively remove almost all streaking artifacts in a large set of clinical CBCT scans with implanted gold markers in the liver. Residual streaking artifacts observed in three CBCT scans may be removed with better marker segmentation.

60 APPLIED LIFE SCIENCES↗

Enhanced Optical Head Tracking for Cranial Radiation Therapy: Supporting Surface Registration by Cutaneous Structures

Purpose: To support surface registration in cranial radiation therapy by structural information. The risk for spatial ambiguities is minimized by using tissue thickness variations predicted from backscattered near-infrared (NIR) light from the forehead. Methods and Materials: In a pilot study we recorded NIR surface scans by laser triangulation from 30 volunteers of different skin type. A ground truth for the soft-tissue thickness was segmented from MR scans. After initially matching the NIR scans to the MR reference, Gaussian processes were trained to predict tissue thicknesses from NIR backscatter. Moreover, motion starting from this initial registration was simulated by 5000 random transformations of the NIR scan away from the MR reference. Re-registration to the MR scan was compared with and without tissue thickness support. Results: By adding prior knowledge to the backscatter features, such as incident angle and neighborhood information in the scanning grid, we showed that tissue thickness can be predicted with mean errors of <0.2 mm, irrespective of the skin type. With this additional information, the average registration error improved from 3.4 mm to 0.48 mm by a factor of 7. Misalignments of more than 1 mm were almost thoroughly (98.9%) pushed below 1 mm. Conclusions: For almost all cases tissue-enhanced matching achieved better results than purely spatial registration. Ambiguities can be minimized if the cutaneous structures do not agree. This valuable support for surface registration increases tracking robustness and avoids misalignment of tumor targets far from the registration site.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trapped-ion cell with improved DC potential harmonicity for FT-ICR MS

The trapped-ion cell is a key component critical for optimal performance in Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry (MS). We have upgraded our 12 Tesla FT-ICR instrument with a new open cylindrical cell that includes four additional cylindrical segments that serve as compensation electrodes. The DC potential on the additional segments can be set to specific pre-calculated values to suppress DC trapping field anharmonicity, in an effort to improve coherence of the ion cyclotron motion and minimize deviations from the calibration function of the ideal cell. Alternatively, the compensation potentials can be set equal to potentials of adjacent cell electrodes, which creates a DC potential distribution equivalent to that of a regular open cylindrical cell. The initial experimental characterization of both the compensated and open cell configurations was performed using ESI direct infusion of a peptide mixture. Operating the compensated cell at increased post-excitation radii resulted in improved mass measurement accuracy together with increased signal intensity, while the regular configuration exhibited peak splitting and reduced signal life time under these operating conditions. The observed improvement of the compensated cell performance was consistent with the expected behavior due to the improved DC potential harmonicity. These results confirm that the trapping DC potential harmonicity is significant for optimizing FT-ICR MS performance.

Tolmachev, Aleksey V.↗

Dynamics of Nanoparticles in Entangled Polymer Solutions

The mean square displacement < r 2 > of nanoparticle probes dispersed in simple isotropic liquids and in polymer solutions is interrogated using fluorescence correlation spectroscopy and single-particle tracking (SPT) experiments. Probe dynamics in different regimes of particle diameter (d), relative to characteristic polymer length scales, including the correlation length (ξ), the entanglement mesh size (a), and the radius of gyration (R g ), are investigated. In simple fluids and for polymer solutions in which d >> R g , long-time particle dynamics obey random-walk statistics < r 2 >:t, with the bulk zero-shear viscosity of the polymer solution determining the frictional resistance to particle motion. In contrast, in polymer solutions with d < R g , polymer molecules in solution exert noncontinuum resistances to particle motion and nanoparticle probes appear to interact hydrodynamically only with a local fluid medium with effective drag comparable to that of a solution of polymer chain segments with sizes similar to those of the nanoparticle probes. Under these conditions, the nanoparticles exhibit orders of magnitude faster dynamics than those expected from continuum predictions based on the Stokes–Einstein relation. SPT measurements further show that when d > a, nanoparticle dynamics transition from diffusive to subdiffusive on long timescales, reminiscent of particle transport in a field with obstructions. This last finding is in stark contrast to the nanoparticle dynamics observed in entangled polymer melts, where X-ray photon correlation spectroscopy measurements reveal faster but hyperdiffusive dynamics. As a result, we analyze these results with the help of the hopping model for particle dynamics in polymers proposed by Cai et al. and, on that basis, discuss the physical origins of the local drag experienced by the nanoparticles in entangled polymer solutions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

THE GREEN BANK TELESCOPE H II REGION DISCOVERY SURVEY. III. KINEMATIC DISTANCES

Using the H I emission/absorption method, we resolve the kinematic distance ambiguity and derive distances for 149 of 182 (82%) H II regions discovered by the Green Bank Telescope H II Region Discovery Survey (GBT HRDS). The HRDS is an X-band (9 GHz, 3 cm) GBT survey of 448 previously unknown H II regions in radio recombination line and radio continuum emission. Here, we focus on HRDS sources from 67 Degree-Sign {>=} l {>=} 18 Degree-Sign , where kinematic distances are more reliable. The 25 HRDS sources in this zone that have negative recombination line velocities are unambiguously beyond the orbit of the Sun, up to 20 kpc distant. They are the most distant H II regions yet discovered. We find that 61% of HRDS sources are located at the far distance, 31% at the tangent-point distance, and only 7% at the near distance. 'Bubble' H II regions are not preferentially located at the near distance (as was assumed previously) but average 10 kpc from the Sun. The HRDS nebulae, when combined with a large sample of H II regions with previously known distances, show evidence of spiral structure in two circular arc segments of mean Galactocentric radii of 4.25 and 6.0 kpc. We perform a thorough uncertainty analysis to analyze the effect of using different rotation curves, streaming motions, and a change to the solar circular rotation speed. The median distance uncertainty for our sample of H II regions is only 0.5 kpc, or 5%. This is significantly less than the median difference between the near and far kinematic distances, 6 kpc. The basic Galactic structure results are unchanged after considering these sources of uncertainty.

79 ASTRONOMY AND ASTROPHYSICS↗

ANALYSIS OF THE SIMULTANEOUS ROTATION AND NON-RADIAL PROPAGATION OF AN ERUPTIVE FILAMENT

The rotation of eruptive filaments is not only related to the kink instability occurring in the solar corona but also may result from the interaction between the large-scale magnetic field and the eruptions themselves. This interaction could likewise make the filament deflect in the radial direction. By means of data obtained by the Atmospheric Imaging Assembly on board the Solar Dynamics Observatory and observations from the Solar Terrestrial Relations Observatory, we study an eruptive filament showing both rotation and non-radial motion. The consequence of the three-dimensional reconstruction of the filament axis indicates that a significant rotation was simultaneous with the severe deflection in the latitude during the eruption. In combination with the results of a derived coronal magnetic configuration, our observations suggested that the non-radial motion resulted from the interaction between the eruption and an overlying pseudostreamer. Moreover, we find that the deflection of the eruption is asymmetric, with its eastern segment being dragged more significantly than its western one. Therefore, we suggested that the action of the asymmetric deflection is possibly an alternative mechanism for the rotation of the eruptive filament.

79 ASTRONOMY AND ASTROPHYSICS↗

EVOLUTION OF A MAGNETIC FLUX ROPE AND ITS OVERLYING ARCADE BASED ON NONLINEAR FORCE-FREE FIELD EXTRAPOLATIONS

Dynamic phenomena indicative of slipping reconnection and magnetic implosion were found in a time series of nonlinear force-free field (NLFFF) extrapolations for the active region 11515, which underwent significant changes in the photospheric fields and produced five C-class flares and one M-class flare over five hours on 2012 July 2. NLFFF extrapolation was performed for the uninterrupted 5 hour period from the 12 minute cadence vector magnetograms of the Helioseismic and Magnetic Imager on board the Solar Dynamic Observatory. According to the time-dependent NLFFF model, there was an elongated, highly sheared magnetic flux rope structure that aligns well with an Hα filament. This long filament splits sideways into two shorter segments, which further separate from each other over time at a speed of 1-4 km s{sup –1}, much faster than that of the footpoint motion of the magnetic field. During the separation, the magnetic arcade arching over the initial flux rope significantly decreases in height from ∼4.5 Mm to less than 0.5 Mm. We discuss the reality of this modeled magnetic restructuring by relating it to the observations of the magnetic cancellation, flares, a filament eruption, a penumbra formation, and magnetic flows around the magnetic polarity inversion line.

79 ASTRONOMY AND ASTROPHYSICS↗

Extraction and analysis of neuron firing signals from deep cortical video microscopy

We introduce a method for extracting and analyzing neuronal activity time signals from video of the cortex of a live animal. The signals correspond to the firing activity of individual cortical neurons. Activity signals are based on the changing fluorescence of calcium indicators in the cells over time. We propose a cell segmentation method that relies on a user-specified center point, from which the signal extraction method proceeds. A stabilization approach is used to reduce tissue motion in the video. The extracted signal is then processed to flatten the baseline and detect action potentials. We show results from applying the method to a cortical video of a live mouse.

Kerekes, Ryan A↗

Identification of breast contour for nipple segmentation in breast magnetic resonance images

Purpose: The purpose of this study is to develop a method to simulate the breast contour and segment the nipple in breast magnetic resonance images. Methods: This study first identifies the chest wall and removes the chest part from the breast MR images. Subsequently, the cleavage and its motion artifacts are removed, distinguishing the separate breasts, where the edge points are sampled for curve fitting. Next, a region growing method is applied to find the potential nipple region. Finally, the potential nipple region above the simulated curve can be removed in order to retain the original smooth contour. Results: The simulation methods can achieve the least root mean square error (RMSE) for certain cases. The proposed YBnd and (Dmin+Dmax)/2 methods are significant due toP = 0.000. The breast contour curve detected by the two proposed methods is closer than that determined by the edge detection method. The (Dmin+Dmax)/2 method can achieve the lowest RMSE of 1.1029 on average, while the edge detection method results in the highest RMSE of 6.5655. This is only slighter better than the comparison methods, which implies that the performance of these methods depends upon the conditions of the cases themselves. Under this method, the maximal Dice coefficient is 0.881, and the centroid difference is 0.36 pixels. Conclusions: The contributions of this study are twofold. First, a method was proposed to identify and segment the nipple in breast MR images. Second, a curve-fitting method was used to simulate the breast contour, allowing the breast to retain its original smooth shape.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nonlocal Means Denoising of Self-Gated and k-Space Sorted 4-Dimensional Magnetic Resonance Imaging Using Block-Matching and 3-Dimensional Filtering: Implications for Pancreatic Tumor Registration and Segmentation

Purpose: To denoise self-gated k-space sorted 4-dimensional magnetic resonance imaging (SG-KS-4D-MRI) by applying a nonlocal means denoising filter, block-matching and 3-dimensional filtering (BM3D), to test its impact on the accuracy of 4D image deformable registration and automated tumor segmentation for pancreatic cancer patients. Methods and Materials: Nine patients with pancreatic cancer and abdominal SG-KS-4D-MRI were included in the study. Block-matching and 3D filtering was adapted to search in the axial slices/frames adjacent to the reference image patch in the spatial and temporal domains. The patches with high similarity to the reference patch were used to collectively denoise the 4D-MRI image. The pancreas tumor was manually contoured on the first end-of-exhalation phase for both the raw and the denoised 4D-MRI. B-spline deformable registration was applied to the subsequent phases for contour propagation. The consistency of tumor volume defined by the standard deviation of gross tumor volumes from 10 breathing phases (σ-GTV), tumor motion trajectories in 3 cardinal motion planes, 4D-MRI imaging noise, and image contrast-to-noise ratio were compared between the raw and denoised groups. Results: Block-matching and 3D filtering visually and quantitatively reduced image noise by 52% and improved image contrast-to-noise ratio by 56%, without compromising soft tissue edge definitions. Automatic tumor segmentation is statistically more consistent on the denoised 4D-MRI (σ-GTV = 0.6 cm{sup 3}) than on the raw 4D-MRI (σ-GTV = 0.8 cm{sup 3}). Tumor end-of-exhalation location is also more reproducible on the denoised 4D-MRI than on the raw 4D-MRI in all 3 cardinal motion planes. Conclusions: Block-matching and 3D filtering can significantly reduce random image noise while maintaining structural features in the SG-KS-4D-MRI datasets. In this study of pancreatic tumor segmentation, automatic segmentation of GTV in the registered image sets is shown to be more consistent on the denoised 4D-MRI than on the raw 4D-MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic resonance cholangiopancreatography using optimized integrated combination with parallel imaging and compressed sensing technique

Purpose: To assess the combined parallel imaging (PI) and optimized integrated compressed sensing technique (prototype Compressed SENSE) for magnetic resonance cholangiopancreatography (MRCP) compared with conventional MRCP. Methods: This prospective study was approved by our Institutional Review Board, and all patients provided written informed consent. A total of 56 consecutive patients (27 men and 29 women; mean age 67.2 years) underwent breath-hold three-dimensional (3D) MRCP with PI alone (BH-MRCP; acquisition time, 23 s), respiratory-triggered 3D MRCP with PI alone (RT-MRCP; 201 s) and respiratory-triggered 3D MRCP with Compressed SENSE (RT-MRCPcs; 45 s). Relative duct-to-periductal contrast ratios (RCs) of the pancreaticobiliary ducts were calculated for quantitative image analyses. Two radiologists graded the visibility of the pancreaticobiliary ducts, pancreatic cystic lesion, motion artifact, and overall image quality using a five-point rating scale for qualitative image analyses. Theses qualitative and quantitative measurements were then compared among the three sequences. Results: RCs of the common bile duct, right hepatic duct (RHD), left hepatic duct (LHD), and main pancreatic duct at the pancreatic head, body, and tail segments, were significantly higher RT-MRCP, followed by RT-MRCPcs and BH-MRCP (P < 0.001). The visibility of the peripheral RHD and LHD was slightly better in RT-MRCP than in RT-MRCPcs and BH-MRCP (P < 0.001). The visibility of other pancreaticobiliary ducts, pancreatic cystic lesion, motion artifact, and overall image quality were almost comparable among three sequences. Conclusion: The acquisition time was markedly reduced in RT-MRCPcs compared with conventional RT-MRCP while there were significant differences in both quantitative and qualitative analyses, the differences were small enough that the reduced acquisition time makes up for it.

62 RADIOLOGY AND NUCLEAR MEDICINE↗