Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operating mode”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Planning and operating experiment S-183 on the three Skylab missions

The Skylab vehicle from its first conception until its flight underwent several iterations. In a similar manner, the scientific experiments changed in both their physical appearance and operational mode because of the evolution of Skylab. In some cases the scientific requirements changed operational requirements of Skylab. The interactions between Skylab and the scientific experiments objectives as well as individual experiment problems are the subject of this paper. The authors use examples from the experiment S-183 (Ultraviolet Panorama) as well as examples from sophisticated groups of experiments such as the Apollo Telescope Mount (ATM). Examples of the positive aspects of the operation are indicated as well as problems, their solution, and the decision-making process. Various phases of the program are discussed and important aspects emphasized. Some general conclusions and recommendations are presented which, hopefully, will aid potential experimenters on Shuttle payloads.

Atkins, H. L.↗

A real-time distributed solid oxide electrolysis cell (SOEC) model for cyber-physical simulation

System integration and dynamic operability between SOEC and balance-of-plant (BoP) components are major technical challenges before realizing rapid load following of SOEC systems. Cyber-physical simulation (CPS) is a leading-edge digital engineering approach and is regarded as the next step beyond Digital Twins. CPS approach can be used to research SOEC system integration and develop dynamic controls prior to actual pilot testing without using a real SOEC. To seamlessly couple with BoP hardware and access non-observable operational parameters (e.g., local temperature gradient) during transients, a distributed one-dimensional (1D) real-time SOEC model was developed. Its real-time execution was demonstrated for 20 to 640 nodes at the fixed time step of 5 ms. A higher excess air ratio enabled smaller local temperature gradients on SOEC solid materials and faster transients upon current density step change from 0.15 to 0.55 A cm -2 . During the transients, the magnitude of the peak temperature gradient nearly doubled in 10 s from -3.5 to -5.9 °C cm -1 . This represents a significant operating risk that can impact the dynamic operability of SOEC systems. In addition, the local temperature gradient was found to change directions on all nodes in SOEC solid materials, with the greatest impact on the upstream nodes. The SOEC model was also tested at the thermal neutral voltage using actual process air flow parameters as variable model inputs. Variable process air temperatures were found to induce alternating local temperature gradients on SOEC solid materials. These are new operational mechanisms for SOEC degradation relevant for load following operational modes yet distinct from previous reports. To mitigate these unfavorable features, the SOEC can be operated at voltages that are slightly (±20 mV) deviated from the thermal neutral voltage. Here, the corresponding net thermal energy change was less than 1.6% of the electric power consumption. This 1D real-time SOEC model established the basis of cyber-physical simulation of SOEC hybrid systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Study of alternate methods of disposal of propellants and gases at KSC

A comprehensive study was conducted at KSC launch support facilities to determine the nature and extent of potential hazards from propellant and gas releases to the environment. The results of the study, alternate methods for reducing or eliminating the hazards, and recommendations pertaining to these alternatives are presented. The operational modes of the propellant or hazardous gas systems considered include: system charging, system standby, system operation, and post-test operations. The results are outlined on an area-by-area basis.

Moore, W. I.↗

Solid state instrumentation concepts for earth resource observation

Late in 1980, specifications were prepared for detail design definition of a six band solid state multispectral instrument having three visible (VIS), one near infrared (NIR), and two short wave infrared (SWIR) bands. This instrument concept, known as the Multispectral Linear Array (MLA), also offered increased spatial resolution, on board gain and offset correction, and additional operational modes which would allow for cross track and stereoscopic viewing as well as a multialtitude operational capability. A description is presented of a summary of some of the salient features of four different MLA design concepts, as developed by four American companies. The designs ranged from the use of multiple refractive telescopes utilizing three groups of focal plane detectors electronic correlation processing for achieving spatial registration, and incorporating palladium silicide (PdSi) SWIR detectors, to a four-mirror all-reflective telecentric system utilizing a beam splitter for spatial registration.

Richard, H. L.↗

Oxidizer heat exchanger component test

The RL10-IIB engine, is capable of multimode thrust operation. The engine operates at two low-thrust levels: tank head idle (THI), approximately 1 to 2 percent of full thrust; and pumped idle, 10 percent of full thrust. Operation at THI provides vehicle propellant settling thrust and efficient thermal conditioning; PI operation provides vehicle tank prepressurization and maneuver thrust for low-g deployment. Stable combustion of the RL10-IIB engine during the low-thrust operating modes can be accomplished by using a heat exchanger to supply gaseous oxygen to the propellant injector. The oxidized heat exchanger (OHE) vaporizes the liquid oxygen using hydrogen as the energy source. This report summarizes the test activity and post-test data analysis for two possible heat exchangers, each of which employs a completely different design philosophy. One design makes use of a low-heat transfer (PHT) approach in combination with a volume to attenuate pressure and flow oscillations. The test data showed that the LHT unit satisfied the oxygen exit quality of 0.95 or greater in both the THI and PI modes while maintaining stability. The HHT unit fulfilled all PI requirements; data for THI satisfactory operation is implied from experimental data that straddle the exact THI operating point.

Kanic, P. G.↗

Telescope protection algorithm for the Space Infrared Telescope Facility

This paper presents a proposed on-board Telescope Protection Algorithm (TPA) for the Space Infrared Telescope Facility (SIRTF). This TPA consists of hardware and software capable of performing both fail-operational and fail-safe modes of operation. In the fail-operational mode, each ephemeris load and slew/dwell command sequence is checked on-board before use. The slew command monitor detects unallowable slew/dwell commands and transfers control to an algorithm which slews to and maintains a safe telescope orientation while preserving precise attitude determination and control. This fail-operational mode is also given the authority to autonomously restart the slew/dwell sequence at a point beyond the faulty command. The fail-safe system consists of software and hardware which detects impending earth, moon, or sun avoidance zone violations and activates a backup hardware safe hold mode. The subject TPA and relevant sensor complement were designed for the SIRTF mission; however, this system can easily be used as a basis for failure detection and correction in a wide range of other missions.

Class, B. F.↗

On multidomain multiscale modeling and simulation of a novel partial pressure and temperature swing adsorptive reactor ($\mathrm{PPTSAR}$) with application to the water gas shift reaction

Here in this work, a dynamic, multidomain, multiscale model of a novel Partial Pressure and Temperature Swing Adsorptive Reactor (PPTSAR) Process is developed and simulated for a Water Gas Shift Reaction (WGSR) application. The proposed model couples the reactor wall, catalyst/adsorbent pellet, and fluid mixture domains at their respective scales to comprehensively model mass, momentum, and energy transport phenomena occurring within each domain. The resulting model elucidates the PPTSAR’s start-up, transient, and long-term, periodic, dynamic behavior, during both adsorption/reaction and desorption operating modes. In the WGSR application considered, the use of two PPTSARs is shown to allow continuous operation that delivers CO conversion greater than 95% with simultaneous complete CO 2 capture.

42 ENGINEERING↗

Operation and performance of VRF systems: Mining a large-scale dataset

The energy consumption of air-conditioning systems has gained increasing attention as it contributes significantly to the global building energy use. The variable refrigerant flow (VRF) system is a common air-conditioning system applied widely in residential and office buildings in China. Understanding the actual operation and performance of VRF systems is fundamental for the energy-efficient design and operation of VRF systems. Previous research on VRF system operation used either limited field data covering certain building types and climate zones or used a questionnaire to obtain a larger dataset. However, they did not capture the wide applications of VRF systems quantitatively across all building types, climate zones, and operating conditions. To fill this gap, statistical and clustering analysis was conducted on the newly proposed key performance indicators of approximately 287,000 VRF systems for residential and commercial buildings in all five climate zones in China. In this work, the main findings are: (1) VRF systems are mainly used for cooling in all climate zones in China; (2) among all building types, the duration of use is lowest in residential buildings and highest in hotels and medical buildings; (3) the distribution of the ideal VRF cooling coefficient of performance (COP) is similar across all climate zones and building types; whereas the COPs of ideal VRF heating in the Severe Cold region and Cold regions are lower than those in other climate zones; and (4) partial load operations for VRF systems are common in residential buildings and office buildings due to the part-time-part-space operation mode. These findings can inform the actual application of VRF systems in China, supporting the design, operation, industry standard development, and performance optimization of VRF systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Operation of a Prototype 750C Advanced Chloride Molten Salt Bellows Valve

To achieve DOE 2030 SunShot targets that reduce the cost of liquid-based solar by an additional 40% to 70% beyond 2018 costs, a more reliable, highly manufacturable flow valve, capable of achieving operational temperatures of >700°C is required [1]. This paper investigates the development of an innovative high-temperature chloride molten salt valve, with operation up to 750°C. This valve is intended to be employed within Gen 3 CSP liquid-based thermal energy storage (TES) systems as well as Gen 4 modular salt reactor (MSR) technologies. This work details the general design and flow testing of a bellows-seal flow control valve (FCV). This design includes an integrated closed-loop thermal control system to ensure robust design for freeze-thaw cycles. The self-contained thermal management STM system, is unique in the salt valve industry since it is an integrated solution to provide a consistent, repeatable alternative to typical heat tracing. Additionally, the design includes the employment of a novel heat pipe valve stem to facilitate enhanced passive thermal management into the valve assembly. This valve stem heat pipe is designed to facilitate natural circulation within the bonnet to ensure robust operation, during both nominal and transient thermal operation. The valve body and trim will be designed using SS316H, consistent with Flowserve Corporation’s existing product base and is code qualified but will utilize clad material for materials corrosion, manufacturing cost reduction and compatibility to ensure design flexibility. A test campaign was performed in this investigation utilizing a novel 750°C ternary chloride (20%NaCl/40%MgCl2/40%KCl by mol. wt. %) molten salt flow loop. A discussion about the design and installation of the valves within this test bed is provided for this investigation. Valve test results from this study assessed Cv curves as well as multiple actuator cycles, under varying thermodynamic and operational mode conditions, which would be characteristic within a commercial molten salt facility. The results indicate nominal operation for the baseline design, though improved performance and reliability is expected with the full designed FCV.

Armijo, Kenneth (ORCID:0000000346832147)↗

A tactile-output paging communication system for the deaf-blind

A radio frequency paging communication system that has coded vibrotactile outputs suitable for use by deaf-blind people was developed. In concept, the system consists of a base station transmitting and receiving unit and many on-body transmitting and receiving units. The completed system has seven operating modes: fire alarm; time signal; repeated single character Morse code; manual Morse code; emergency aid request; operational status test; and message acknowledge. The on-body units can be addressed in three ways: all units; a group of units; or an individual unit. All the functions developed were integrated into a single package that can be worn on the user's wrist. The control portion of the on-body unit is implemented by a microcomputer. The microcomputer is packaged in a custom-designed hybrid circuit to reduce its physical size.

Baer, J. A.↗

Advanced ramjet concepts program

Uniquely advantageous features, on both the performance and weight sides of the ledger, can be achieved through synergistic design integration of airbreathing and rocket technologies in the development of advanced orbital space transport propulsion systems of the combined cycle type. In the context of well understood advanced airbreathing and liquid rocket propulsion principles and practices, this precept of synergism is advanced mainly through six rather specific examples. These range from the detailed component level to the overall vehicle system level as follows: using jet compression; achieving a high area ratio rocket nozzle; ameliorating gas generator cycle rocket system deficiencies; using the in-duct special rocket thrust chamber assembly as the principal scramjet fuel injection operation; using the unstowed, covered fan as a duct closure for effecting high area ratio rocket mode operation; and creating a unique airbreathing rocket system via the onboard, cryogenic hydrogen induced air liquefaction process.

Leingang, J. L.↗

Implementing the Mars Science Laboratory Terminal Descent Sensor Field Test Campaign

The Mars Science Laboratory (MSL) will deliver a 900 kg rover to the surface of Mars in August 2012. MSL will utilize a new pulse-Doppler landing radar, the Terminal Descent Sensor (TDS). The TDS employs six narrow-beam antennas to provide unprecedented slant range and velocity performance at Mars to enable soft touchdown of the MSL rover using a unique sky crane Entry, De-scent, and Landing (EDL) technique. Prior to use on MSL, the TDS was put through a rigorous verification and validation (V&V) process. A key element of this V&V was operating the TDS over a series of field tests, using flight-like profiles expected during the descent and landing of MSL over Mars-like terrain on Earth. Limits of TDS performance were characterized with additional testing meant to stress operational modes outside of the expected EDL flight profiles. The flight envelope over which the TDS must operate on Mars encompasses such a large range of altitudes and velocities that a variety of venues were neces-sary to cover the test space. These venues included an F/A-18 high performance aircraft, a Eurocopter AS350 AStar helicopter and 100-meter tall Echo Towers at the China Lake Naval Air Warfare Center. Testing was carried out over a five year period from July 2006 to June 2011. TDS performance was shown, in gen-eral, to be excellent over all venues. This paper describes the planning, design, and implementation of the field test campaign plus results and lessons learned.

Mars Science Laboratory (MSL)↗

Future Airspace Operations

NASA is exploring a proposed new operating mode called digital flight, a complement to VFR and IFR. Under digital flight rules, the aircraft operator would use automation, traffic awareness, information services, and cooperative practices to ensure separation from other flights in VMC and IMC. The presentation describes how digital flight safely increases airspace access and operating flexibility for qualified operators, and its harmonizing approach to emerging future operations.

Airspace↗

Future Airspace Operations

NASA is exploring a proposed new operating mode called digital flight, a complement to VFR and IFR. Under digital flight rules, the aircraft operator would use automation, traffic awareness, information services, and cooperative practices to ensure separation from other flights in VMC and IMC. The presentation describes how digital flight safely increases airspace access and operating flexibility for qualified operators, and its harmonizing approach to emerging future operations.

Airspace↗

First access to ELM-free negative triangularity at low aspect ratio

A plasma scenario with negative triangularity (NT) shaping is achieved on MAST-U for the first time. While edge localized modes (ELMs) are eventually suppressed as the triangularity is decreased below δ ≲ –0.06, an extended period of H-mode operation with Type-III ELMs is sustained at less negative δ even through access to the second stability region for ideal ballooning modes is closed. This documents a qualitative difference from the ELM-free access conditions documented in NT scenarios on conventional aspect ratio machines. The electron temperature at the pedestal top drops across the transition to ELM-free operation, but a steady rise in core temperature as δ is decreased allows for similar normalized β in the ELM-free NT and H-mode positive triangularity shapes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical and experimental analysis of precooled desiccant system

This paper presents a numerical and experimental study of four novel, desiccant air-conditioning systems based on pre-cooling of the ambient air. The purpose of the study is to: 1) establish which configuration is most profitable for the future studies through numerical and experimental methods; 2) verify the concept of precooled system and confirm that it is working in experimental conditions (for this purpose two prototypes of evaporative cooling units were developed and compared for different operation arrangements with desiccant wheel); 3) Analyze practical aspects of the systems, which includes water consumption analysis, economic analysis and establishing operational modes during a cooling season in temperate climate conditions (the proposed solution has a significant advantage during operation in a temperate climate, since it can utilize its first evaporative cooler the only source of cooling energy when the humidity of outdoor air allows to to meet the latent cooling load). Four arrangements of the system with different dew point evaporative air cooler prototypes were selected and developed for comparative analysis. The system was simulated as a whole, also, each component was individually tested on measurement station. develop the optimal arrangement of the system through numerical and experimental analysis. Four different performance indicators were considered: thermal COP (Coefficient Of Performance), the ERR (Energy Efficiency Ratio), coefficient a describing the potential in compensating indoor cooling loads, water consumption ratio. Also costs of the systems were compared through economic analysis. It was established that arrangement which is characterized by best-averaged performance in terms of all considered factors is a unit combined with two different types of evaporative coolers (marked as System B)- this is caused by the favorable arrangement of two units, where one is better suited to the pre-cooler role, while the other is better suited as the post-cooler.

42 ENGINEERING↗

Linear thermomagnetic energy harvester for low-grade thermal energy harvesting

Low-grade thermal energy, either from waste heat or from natural resources, constitutes an enormous energy reserve that remains to be fully harvested. Harvesting low-grade heat is challenging because of the low Carnot efficiency. Among various thermal energy harvesting mechanisms available for capturing low-grade heat (temperature less than 100 degrees C), the thermomagnetic effect has been found to be quite promising. In this study, we demonstrate a scalable thermomagnetic energy harvester architecture that exhibits 140% higher power density compared to the previously published spring-mass designs. The alternating force required to oscillate the thermomagnetic mass is generated through the interaction between two magnetic forces in opposite directions. We employed numerical modeling to illustrate the behavior of a thermomagnetic device under different operating conditions and to obtain the optimal hot-side and cold-side temperatures for continuous mode operations. A miniaturized thermomagnetic harvester was fabricated and experiments were conducted to systematically evaluate the performance. The prototype was found to exhibit an oscillation frequency of 0.33 Hz, a work output of 0.6 J/kg/cycle, and a power density of 0.2 W/kg of gadolinium under the temperature difference of 60 K.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

VSC-HVDC Interties for Urban Power Grid Enhancement

Urban power grids are facing many operational and expansion challenges to meet further demand growth and increased reliability requirements. Advanced transmission technologies have been considered by the electric utilities to effectively increase the utilization of existing infrastructure and operational flexibility. The focus of this paper is on VSC-HVDC technologies for urban power grid enhancement and modernization. First, a potential technical scheme is proposed for converting an existing AC circuit to DC operation, which could boost the power transfer capability of the critical transmission corridor and increase network operational flexibility. Second, this paper proposes three operation modes for the VSC-HVDC interties in urban power grids corresponding to normal, emergency and island operating conditions, respectively. An integrated, adaptive emergency control strategy (AEC) is proposed that can enable adaptive power flow responses of the VSC-HVDC intertie under varying system operating conditions and critical contingencies. The flexibility and effectiveness of the proposed operational principles of urban VSC-HVDC intertie and the corresponding control strategies are verified in PSCAD/EMTDC using a realistic urban power grid in China.

24 POWER TRANSMISSION AND DISTRIBUTION↗