Optical Simulations for the VENUS Neutron Imaging Instrument

The VENUS Neutron Imaging instrument at the Spallation Neutron Source has gone through a multitude of optical design changes since its original conception. The goal of this report is to quantify the performance of the most recent optical design and provide insight into potential improvements to this design as needed to ensure optimal performance of the instrument. The results will come in the form of a refined and well developed simulation that provides as best a representation of the performance of the instrument as reasonably achievable. This simulation will be available in a repository alongside relevant simulation output needed to inform any future decisions on the design of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The feasibility and design of optical sensors for modal control

The feasibility of optical type sensors for control of flexible bodies was examined. The accuracies of such systems were determined via simulation and the sources of potential errors were designated. An initial laboratory design was effected and preliminary results obtained. These results are discussed critically with applications to future studies and system designs.

Lundquist, Charles A.↗

The Space Infrared Interferometric Telescope (SPIRIT): Optical System Design Considerations

SPIRIT is a candidate NASA Origins Probe mission. It is a spatial and spectral interferometer operating at 4 K with an operating wavelength range 25 - 400 microns. This paper describes the various components of the candidate optical system, including telescopes, pointing and tracking optics, along with their functions. Some of the tradeoffs involved in selecting various components, with their particular characteristics, are described.

Wilson, Mark E.↗

High Accuracy, Absolute, Cryogenic Refractive Index Measurements of Infrared Lens Materials for JWST NIRCam using CHARMS

The current refractive optical design of the James Webb Space Telescope (JWST) Near Infrared Camera (NIRCam) uses three infrared materials in its lenses: LiF, BaF2, and ZnSe. In order to provide the instrument s optical designers with accurate, heretofore unavailable data for absolute refractive index based on actual cryogenic measurements, two prismatic samples of each material were measured using the cryogenic, high accuracy, refraction measuring system (CHARMS) at NASA GSFC, densely covering the temperature range from 15 to 320 K and wavelength range from 0.4 to 5.6 microns. Measurement methods are discussed and graphical and tabulated data for absolute refractive index, dispersion, and thermo-optic coefficient for these three materials are presented along with estimates of uncertainty. Coefficients for second order polynomial fits of measured index to temperature are provided for many wavelengths to allow accurate interpolation of index to other wavelengths and temperatures.

Leviton, Douglas↗

On the effective spectral emissivity of clear skies and the radiative cooling potential of selectively designed materials

Thermophotonic devices are optically designed to be spectrally selective in order to reject heat to outer space through atmospheric windows of low thermal absorption. The determination of thermal equilibrium temperatures for thermophotonic devices requires the knowledge of the effective spectral emissivity of the sky. In this work, individual contributions of participating gases and aerosols to the spectral values of the sky emissivity are analyzed in the entire infrared spectrum as well as in seven distinct bands for which water vapor either dominates or is virtually transparent to infrared radiation. We also propose high-fidelity correlations for the effective sky emissivity as functions of the normalized ambient partial pressure of water vapor () for both broadband and for the seven spectral bands. Here, the correlations are derived using a combination of ground experimental data, high resolution spectral data for the main atmospheric constituents and spectral models to reconstruct the spectral distribution of infrared thermal radiation from the atmosphere to the ground. These results enable direct calculation of the equilibrium temperature and cooling efficiency of radiative cooling devices in terms of meteorological conditions observed at the surface level. For hot and dry conditions, the passive radiative coolers have a cooling potential of 150.8 W m–2 while for humid conditions, the coolers are mostly ineffective.

14 SOLAR ENERGY↗

Technical overview of the millimeter-wave imaging reflectometer on the DIII-D tokamak (invited)

The two-dimensional mm-wave imaging reflectometer (MIR) on DIII-D is a multi-faceted device for diagnosing electron density fluctuations in fusion plasmas. Its multi-channel, multi-frequency capabilities and high sensitivity permit visualization and quantitative diagnosis of density perturbations, including correlation length, wavenumber, mode propagation velocity, and dispersion. The two-dimensional capabilities of MIR are made possible with 12 vertically separated sightlines and four-frequency operation (corresponding to four radial channels). The 48-channel DIII-D MIR system has a tunable source that can be stepped in 500 μs increments over a range of 56 to 74 GHz. An innovative optical design keeps both on-axis and off-axis channels focused at the cutoff surface, permitting imaging over an extended poloidal region. The integrity of the MIR optical design is confirmed by comparing Gaussian beam calculations to laboratory measurements of the transmitter beam pattern and receiver antenna patterns. Measurements are presented during the density ramp of a plasma discharge to demonstrate unfocused and focused MIR signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scattering Solar Thermal Concentrators

This program set out to explore a scattering-based approach to concentrate sunlight with the aim of improving collector field reliability and of eliminating wind loading and gross mechanical movement through the use of a stationary collection optic. The approach is based on scattering sunlight from the focal point of a fixed collection optic into the confined modes of a sliding planar waveguide, where it is transported to stationary tubular heat transfer elements located at the edges. Optical design for the first stage of solar concentration, which entails focusing sunlight within a plane over a wide range of incidence angles (>120 degree full field of view) at fixed tilt, led to the development of a new, folded-path collection optic that dramatically out-performs the current state-of-the-art in scattering concentration. Rigorous optical simulation and experimental testing of this collection optic have validated its performance. In the course of this work, we also identified an opportunity for concentrating photovoltaics involving the use of high efficiency microcells made in collaboration with partners at the University of Illinois. This opportunity exploited the same collection optic design as used for the scattering solar thermal concentrator and was therefore pursued in parallel. This system was experimentally demonstrated to achieve >200x optical concentration with >70% optical efficiency over a full day by tracking with <1 cm of lateral movement at fixed latitude tilt. The entire scattering concentrator waveguide optical system has been simulated, tested, and assembled at small scale to verify ray tracing models. These models were subsequently used to predict the full system optical performance at larger, deployment scale ranging up to >1 meter aperture width. Simulations at an aperture widths less than approximately 0.5 m with geometric gains ~100x predict an overall optical efficiency in the range 60-70% for angles up to 50 degrees from normal. However, the concentrator optical efficiency was found to decrease significantly with increasing aperture width beyond 0.5 m due to parasitic waveguide out-coupling loss and low-level absorption that become dominant at larger scale. A heat transfer model was subsequently implemented to predict collector fluid heat gain and outlet temperature as a function of flow rate using the optical model as a flux input. It was found that the aperture width size limitation imposed by the optical efficiency characteristics of the waveguide limits the absolute optical power delivered to the heat transfer element per unit length. As compared to state-of-the-art parabolic trough CPV system aperture widths approaching 5 m, this limitation leads to an approximate factor of order of magnitude increase in heat transfer tube length to achieve the same heat transfer fluid outlet temperature. The conclusion of this work is that scattering solar thermal concentration cannot be implemented at the scale and efficiency required to compete with the performance of current parabolic trough CSP systems. Applied within the alternate context of CPV, however, the results of this work have likely opened up a transformative new path that enables quasi-static, high efficiency CPV to be implemented on rooftops in the form factor of traditional fixed-panel photovoltaics.

14 SOLAR ENERGY↗

Radiometric accuracy of the Diffuse Infrared Background Experiment (DIRBE)

The Diffuse Infrared Background Experiment (DIRBE) is a cryogenically-cooled 10-band photometer with a large field-of-view (0.886 x 0.886 sq deg) which scans by rotation of the Cosmic Background Explorer about a spin axis. In-orbit calibration requires that the DIRBE detect and measure with precision the signatures of compact sources as they transit the field-of-view. Analysis of the conceptual optical design revealed that response of the 10 bands would vary significantly as a function of source position in the field-of-view, caused by anamorphic pupil distortion and field separation. The optical design reported in this paper is the result of changes which greatly improve the response uniformity and radiometric accuracy of the DIRBE.

Howell, B. J.↗

A Method of Monitoring Non-Resonant Raman Lidar Returns During Daylight Hours

A method for using non-resonant Raman lidar during daytime hours is presented. A dual (or quadruple) arrangement of electro-optical channels is set up in the lidar receiver. Each channel contains its own optical spectral response as determined by an appropriate set of interference filters. The incoming signal is split and fed into two channels, filtered (simultaneously) and then inserted into the input terminals of an operational amplifier. The difference signal is selected and amplified whereas the common portion of the signal is highly attenuated (Common Mode Re.jection Ratio = 75-80db). For the present hardware, daylight intensities 10(exp 2)-10(exp 3) times Raman signals are received simultaneously. Mean values of intensities of daylight signals which give rise to a constant differences merely shift the value of the measured variable at the ground. These mean value signals have their common part highly attenuated. The differences of the fluctuation portions of the daylight signal represents a noise signal. Identical (space-time) optical paths for each component of the daylight signal produce the same fluctuational spectra in each channel. Hence noise levels, much less than signal levels, are anticipated. First a N2-H2 ) signal pair is differenced. Then an N2-O2 pair is differenced and used for instrumental normalization purposes. Signal levels to be encountered are quite well known as a result of prior field work. Improved optical design of laser system can reduce mean value of daylight intensities by 10(exp 2). Thus the mean daylight intensity can be set equal to the expected signal levels by more advanced optical design. Performance characteristics of photomultiplier pairs are discussed in this connection.

Cooney, John↗

Raytracing the long trace profiler

The optical design of the Long Trace Profiler optical system is explored with a commercial raytrace program, Zemax OpticStudio™ (ZOS)1, with the intent of finding and correcting sources of systematic error. ZOS provides both geometric raytracing tools and physical optics Gaussian beam propagation and diffraction image calculation tools, and two design modes, sequential component (SC) and non-sequential component (NSC) that are optimized for different aspects of the design process. The original LTP-II system employs a singlet lens with a 1250 mm focal length. It is optimized to provide minimum distortion over a surface slope angle range of ±5 mrad. Using the ZOS tools, we are able to simulate ghost rays that produce distortion in the beam spot image and can minimize the distortion by deliberate misalignment of the beamsplitter (BS) components. Unfortunately, the reference beam is compromised because of the component tilts. The most recent LTP500 system design simplifies the optical system and makes the reference beam usable again, even with misalignment of the polarizing beamsplitter (PBS). Two lenses are designed for the LTP500 - a cemented doublet that has been fabricated, and a singlet with one aspheric surface. Both have focal distances of 500 mm with an expanded angular measurement range of ±10 mrad. The aspheric singlet provides superior performance. ZOS allows the import of wavefront measurement data produced by commercial interferometer software. We apply the wavefront error measurement from the cemented doublet to the model to show that the 19nm RMS wavefront error needs to be improved by at least a factor of ten in order to reduce the systematic error to a level that will allow the LTP to approach its design limit of a few tens of nanoradians.

Takacs, Peter Z.↗

Design and characterization of electron beam focusing for X-ray generation in novel medical imaging architecture

A novel electron beam focusing scheme for medical X-ray sources is described in this paper. Most vacuum based medical X-ray sources today employ a tungsten filament operated in temperature limited regime, with electrostatic focusing tabs for limited range beam optics. This paper presents the electron beam optics designed for the first distributed X-ray source in the world for Computed Tomography (CT) applications. This distributed source includes 32 electron beamlets in a common vacuum chamber, with 32 circular dispenser cathodes operated in space charge limited regime, where the initial circular beam is transformed into an elliptical beam before being collected at the anode. The electron beam optics designed and validated here are at the heart of the first Inverse Geometry CT system, with potential benefits in terms of improved image quality and dramatic X-ray dose reduction for the patient.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reluctant glass formers and their applications in optical lens design

Over ten years ago, it was shown that glasses with high index of refraction and some with low dispersion could be produced from a number of pure refractory oxides, including the lanthanides, by containerless processing. By containerless processing it is possible to minimize surface heterogeneous nucleation and produce larger glass samples of the materials than by other methods. The use of proposed high temperature containerless processing facilities in space permits the fabrication of benchmark samples of new unique glass compositions for optical property determination as well as for glass formation. It was shown that glasses with high refractive indices and large Abbe numbers can be formulated using this technology. These glasses lie in the classical forbidden region of the glass map. Preliminary study of the impact of having such unusual glasses available for the lens designer was made. Results indicate that significant improvements can be realized over the use of only conventional glasses. A cursory survey of a number of nationally recognized lens designers indicated a general agreement that such glasses would be highly desired and could be expected to lead to completely new designs as well as simplifying existing designs.

Ethridge, Edwin C.↗

The laser micro-machining system for diamond anvil cell experiments and general precision machining applications at the High Pressure Collaborative Access Team

We report we have designed and constructed a new system for micro-machining parts and sample assemblies used for diamond anvil cells and general user operations at the High Pressure Collaborative Access Team, sector 16 of the Advanced Photon Source. The new micro-machining system uses a pulsed laser of 400 ps pulse duration, ablating various materials without thermal melting, thus leaving a clean edge. With optics designed for a tight focus, the system can machine holes any size larger than 3 μm in diameter. Unlike a standard electrical discharge machining drill, the new laser system allows micro-machining of non-conductive materials such as: amorphous boron and silicon carbide gaskets, diamond, oxides, and other materials including organic materials such as polyimide films (i.e., Kapton). An important feature of the new system is the use of gas-tight or gas-flow environmental chambers which allow the laser micro-machining to be done in a controlled (e.g., inert gas) atmosphere to prevent oxidation and other chemical reactions in air sensitive materials. The gas-tight workpiece enclosure is also useful for machining materials with known health risks (e.g., beryllium). Specialized control software with a graphical interface enables micro-machining of custom 2D and 3D shapes. The laser-machining system was designed in a Class 1 laser enclosure, i.e., it includes laser safety interlocks and computer controls and allows for routine operation. Though initially designed mainly for machining of the diamond anvil cell gaskets, the laser-machining system has since found many other micro-machining applications, several of which are presented here.

47 OTHER INSTRUMENTATION↗

Design Evolution of the Wide Field Infrared Survey Telescope using Astrophysics Focused Telescope Assets (WFIRST-AFTA) and Lessons Learned

The design of the Wide Field Infrared Survey Telescope using Astrophysics Focused Telescope Assets (WFIRST-AFTA) continues to evolve as each design cycle is analyzed. In 2012, two Hubble sized (2.4 m diameter) telescopes were donated to NASA from elsewhere in the Federal Government. NASA began investigating potential uses for these telescopes and identified WFIRST as a mission to benefit from these assets. With an updated, deeper, and sharper field of view than previous design iterations with a smaller telescope, the optical designs of the WFIRST instruments were updated and the mechanical and thermal designs evolved around the new optical layout. Beginning with Design Cycle 3, significant analysis efforts yielded a design and model that could be evaluated for Structural-Thermal-Optical-Performance (STOP) purposes for the Wide Field Imager (WFI) and provided the basis for evaluating the high level observatory requirements. Development of the Cycle 3 thermal model provided some valuable analysis lessons learned and established best practices for future design cycles. However, the Cycle 3 design did include some major liens and evolving requirements which were addressed in the Cycle 4 Design. Some of the design changes are driven by requirements changes, while others are optimizations or solutions to liens from previous cycles. Again in Cycle 4, STOP analysis was performed and further insights into the overall design were gained leading to the Cycle 5 design effort currently underway. This paper seeks to capture the thermal design evolution, with focus on major design drivers, key decisions and their rationale, and lessons learned as the design evolved.

Thermal Design↗

Design Evolution of the Wide Field Infrared Survey Telescope Using Astrophysics Focused Telescope Assets (WFIRST-AFTA) and Lessons Learned

The design of the Wide Field Infrared Survey Telescope using Astrophysics Focused Telescope Assets (WFIRST-AFTA) continues to evolve as each design cycle is analyzed. In 2012, two Hubble sized (2.4 m diameter) telescopes were donated to NASA from elsewhere in the Federal Government. NASA began investigating potential uses for these telescopes and identified WFIRST as a mission to benefit from these assets. With an updated, deeper, and sharper field of view than previous design iterations with a smaller telescope, the optical designs of the WFIRST instruments were updated and the mechanical and thermal designs evolved around the new optical layout. Beginning with Design Cycle 3, significant analysis efforts yielded a design and model that could be evaluated for Structural-Thermal-Optical-Performance (STOP) purposes for the Wide Field Imager (WFI) and provided the basis for evaluating the high level observatory requirements. Development of the Cycle 3 thermal model provided some valuable analysis lessons learned and established best practices for future design cycles. However, the Cycle 3 design did include some major liens and evolving requirements which were addressed in the Cycle 4 Design. Some of the design changes are driven by requirements changes, while others are optimizations or solutions to liens from previous cycles. Again in Cycle 4, STOP analysis was performed and further insights into the overall design were gained leading to the Cycle 5 design effort currently underway. This paper seeks to capture the thermal design evolution, with focus on major design drivers, key decisions and their rationale, and lessons learned as the design evolved.

WFIRST↗

High Efficacy, Multi-Functional Solid-State Lighting Platform

Cree successfully executed an 18-month Product Development research program which yielded significant advancements in solid-state luminaire efficacy, optics design, color tunability, and light utilization. The synergistic development of these technologies was intended to result in ultra-high efficacy luminaires with superior beam definition over conventional fixtures, leading to higher spatial light utilization based on application needs. In addition, program-derived technologies are expected to directly benefit automated dimming which reduces time-averaged lighting energy consumption. Program innovations were made in the areas of: light engines; low-profile modular optical designs; ultra-compact color sensors; and low-cost scene sensors for accurate occupancy detection in challenging application settings. Cree’s DOE-supported work in these technology focus areas will set the stage for further development toward productization at Cree.