Search NASA⌕ Search

SEARCH · Search NASA

Results for “PENETRATION DEPTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

THREE-DIMENSIONAL THERMAL MODELING ANALYSIS OF CST MEDIA FOR THE SMALL ION EXCHANGE PROJECT

The Small Column Ion Exchange (SCIX) project is designed to accelerate closure of High Level Waste (HLW) tanks at the Savannah River Site (SRS). The SRS tanks store HLW in three forms: sludge, saltcake, and supernate. An in-tank ion exchange process is being designed to treat supernate and dissolved saltcake waste. Through this process, radioactive cesium from the salt solution is adsorbed into Crystalline Silicotitanate (CST) ion exchange media packed within a flow-through column. A packed column loaded with radioactive cesium generates significant heat from radiolytic decay. The waste supernate solution within the ion exchange bed will boil around 120 C. Solution superheating above the boiling point within the column could lead to violent hazardous energy releases. System heating from loaded CST is also of concern in other process modules, such as the waste tank. Due to tank structural integrity concerns, the wall temperature limit for the SRS waste tanks is 100 C. The transfer of cesium-loaded CST to the tank could result in localized hot spots on the tank floor and walls which may exceed this limit. As a result, thermal modeling calculations have been conducted to predict the maximum temperatures achievable both in the column and in the waste tank. As specified in the associated Technical Task Plan, one objective of the present work was to compute temperature distributions within the ion exchange column module under accident scenarios including loss of salt solution flow through the bed and loss of coolant system flow. The column modeling domain and the scope of the calculations in this case were broadened relative to previous two-dimensional calculations to include vertical temperature distributions within the packed bed of ion exchange media as well as the upper column plenum region containing only fluid. The baseline design conditions and in-column modeling domain for the ion-exchange column module are shown in Figure 1. These evaluations assumed the maximum bounding cesium loading considered possible based on current knowledge regarding CST media and the anticipated feed compositions. Since this cesium loading was considerably higher than the nominal loading conditions in SRS waste, cases with lower loading were also evaluated. Modeling parameters were the same as those used previously unless otherwise indicated. The current model does not capture multi-phase cooling mechanisms operative when solution boiling occurs. This feature is conservative in the sense that it does not account for the large cooling effects associated with phase transfer. However, the potential transfer of heat to the plenum region associated with vertical bubble ascension through the column during boiling is also neglected. Thermal modeling calculations were also performed for the entire waste storage tank for the case where loaded and ground CST was transferred to the tank. The modeling domain used for the in-tank calculations is provided in Figure 2. The in-tank domain is based on SRS Tank 41, which is a Type-IIIA tank. Temperature distributions were evaluated for cylindrical, ground CST mounds located on the tank floor. Media grinding is required prior to vitrification processing of the CST in the SRS Defense Waste Processing Facility (DWPF). The location of the heat source region on the tank floor due to the accumulation of CST material was assumed to be just under the grinder. The shape of the CST mound was assumed to be cylindrical. This shape is believed to be most representative of the actual mound shape formed in the tank, given that submersible mixing pumps will be available for media dispersion. Alternative configurations involving other geometrical shapes for the CST mound were evaluated in the previous work. Sensitivity analysis for the in-tank region was performed for different amounts of CST media. As was the case for the in-column model, the in-tank model does not include multi-phase cooling mechanisms operative when solution boiling occurs. The in-column and the in-tank evaluations incorporated recently updated maximum cesium loading levels calculated using the current SCIX feed compositions, which resulted in significantly higher cesium loading than previously calculated. The calculations were conducted to ensure conservative predictions for the maximum temperatures achievable using the current baseline design. The degree of conservatism was reduced for in-column calculations relative to the previous work by using a three-dimensional modeling approach and selecting parameters which were nearer to expected conditions. The degree of conservatism for the in-tank calculations was also reduced by lowering the soil penetration depth below the tank from 150 to 20 feet. The primary goals of the extended thermal modeling effort were to determine whether fluid boiling or superheating are possible within the column module and to determine the maximum floor temperatures within the tank loaded with spent CST.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Influence of activation parameters on the thickness of MgO thin film on Ag-3Mg alloy and its secondary electron emission property

Highlights: • MgO films with controlled thicknesses on Ag-3Mg alloys were prepared by activation in low vacuum with oxygen. • Superior secondary electron yield was obtained for the Ag-3Mg alloy with proper thickness of MgO film. • Oxygen pressure during the activation process is crucial for obtaining good secondary electron yield for Ag-3Mg alloys. • The mechanism of secondary electron emission in MgO films is discussed. - Abstract: MgO thin films of different thicknesses were prepared on polished Ag-3wt%Mg alloy by an activation process at 500–650 °C under oxygen pressures of 0.5–10.0 Pa. The influence of the thickness of MgO film on the secondary electron yield of the Ag-3wt%Mg alloy is investigated. The alloy with an MgO film of moderate thickness of 65 ± 1 nm shows the highest secondary electron yield of 10. Oxygen pressure below 10.0 Pa is crucial for the formation of intact MgO film on the top surface. Computational simulation analysis reveals that the maximum yield occurs when the penetration depth of primary electrons is 13–18 nm less than the thickness of MgO film. Electron supply of this extra MgO film is allowed by an electron tunneling mechanism under certain bias voltage. The replenishment of new electrons to the electron deficient surface is crucial for obtaining optimized secondary electron yields for Ag-Mg alloy cathodes.

36 MATERIALS SCIENCE↗

Role of neutral gas in scrape-off layer tokamak plasma

Neutral gas in scrape-off layer of tokamak plasma plays an important role as it can modify the plasma turbulence. In order to investigate this, we have derived a simple two-dimensional (2D) model that consists of electron continuity, quasi-neutrality, and neutral gas continuity equations using neutral gas ionization and charge exchange processes. Simple 1D profile analysis predicts neutral penetration depth into the plasma. Growth rate obtained from the linear theory has been presented. The 2D model equations have been solved numerically. It is found that the neutral gas reduces plasma fluctuations and shifts spectrum of the turbulence towards lower frequency side. The neutral gas fluctuation levels have been presented. The numerical results have been compared with Aditya tokamak experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Superconductivity in La1.56Sr0.44CuO4/La2CuO4 Superlattices

Superlattices of the repeated structure La{sub 1.56}Sr{sub 0.44}CuO{sub 4}/La{sub 2}CuO{sub 4} (LSCO-LCO), where none of the constituents is superconducting, show a superconducting transition of T{prime}{sub c} 25 K. In order to elucidate the nature of the superconducting state we have performed a low-energy {mu}SR study. By applying a magnetic field parallel (Meissner state) and perpendicular (vortex state) to the film planes, we could show that superconductivity is sheet like, resulting in a very anisotropic superconducting state. This result is consistent with a simple charge-transfer model, which takes into account the layered structure and the difference in the chemical potential between LCO and LSCO, as well as Sr interdiffusion. Using a pancake-vortex model we could estimate a strict upper limit of the London penetration depth to 380 nm in these superlattices. The temperature dependence of the muon depolarization rate in field cooling experiments is very similar to what is observed in intercalated BSCCO and suggests that vortex-vortex interaction is dominated by electromagnetic coupling but negligible Josephson interaction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetic field of Josephson vortices outside superconductors

We consider the structure of Josephson vortices approaching the junction boundary with vacuum in large-area Josephson junctions with the Josephson length {lambda}{sub J} large relative to the London penetration depth {lambda}{sub L}. Using the stability argument for one-dimensional solitons with respect to two-dimensional perturbations, it is shown that on the scale {lambda}{sub J}, the Josephson vortices do not spread near the boundary in the direction of the junction. The field distribution in vacuum due to the Josephson vortex is evaluated, the information needed for the scanning superconducting quantum interference device microscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A COAXIAL TE011 CAVITY AND A SYSTEM TO MEASURE DC AND RF PROPERTIES OF SUPERCONDUCTORS

A coaxial niobium cavity has been designed and built where the center conductor consists of a removable sample. In addition, a system to measure properties such as magnetization, penetration depth, critical temperature and thermal conductivity on the same cylindrical sample has been designed and built. The purpose of this effort is to investigate possible correlations between DC and RF properties of superconductors. In this contribution, the design of the various components is discussed and the test results on a niobium sample obtained so far are presented.

47 OTHER INSTRUMENTATION↗

A COAXIAL TE011 CAVITY AND A SYSTEM TO MEASURE DC AND RF PROPERTIES OF SUPERCONDUCTORS

A coaxial niobium cavity has been designed and built where the center conductor consists of a removable sample. In addition, a system to measure properties such as magnetization, penetration depth, critical temperature and thermal conductivity on the same cylindrical sample has been designed and built. The purpose of this effort is to investigate possible correlations between DC and RF properties of superconductors. In this contribution, the design of the various components is discussed and the test results on a niobium sample obtained so far are presented.

47 OTHER INSTRUMENTATION↗

Comparison of measured with calculated dose distribution from a 120-MeV electron beam from a laser-plasma accelerator

Purpose: To evaluate the dose distribution of a 120-MeV laser-plasma accelerated electron beam which may be of potential interest for high-energy electron radiation therapy. Methods: In the interaction between an intense laser pulse and a helium gas jet, a well collimated electron beam with very high energy is produced. A secondary laser beam is used to optically control and to tune the electron beam energy and charge. The potential use of this beam for radiation treatment is evaluated experimentally by measurements of dose deposition in a polystyrene phantom. The results are compared to Monte Carlo simulations using the geant4 code. Results: It has been shown that the laser-plasma accelerated electron beam can deliver a peak dose of more than 1 Gy at the entrance of the phantom in a single laser shot by direct irradiation, without the use of intermediate magnetic transport or focusing. The dose distribution is peaked on axis, with narrow lateral penumbra. Monte Carlo simulations of electron beam propagation and dose deposition indicate that the propagation of the intense electron beam (with large self-fields) can be described by standard models that exclude collective effects in the response of the material. Conclusions: The measurements show that the high-energy electron beams produced by an optically injected laser-plasma accelerator can deliver high enough dose at penetration depths of interest for electron beam radiotherapy of deep-seated tumors. Many engineering issues must be resolved before laser-accelerated electrons can be used for cancer therapy, but they also represent exciting challenges for future research.

61 RADIATION PROTECTION AND DOSIMETRY↗

Critical magnetic fields of superconducting aluminum-substituted Ba{sub 8}Si{sub 42}Al{sub 4} clathrate

In recent years, efforts have been made to explore the superconductivity of clathrates containing crystalline frameworks of group-IV elements. The superconducting silicon clathrate is unusual in that the structure is dominated by strong sp{sup 3} covalent bonds between silicon atoms, rather than the metallic bonding that is more typical of traditional superconductors. This paper reports on critical magnetic fields of superconducting Al-substituted silicon clathrates, which were investigated by transport, ac susceptibility, and dc magnetization measurements in magnetic fields up to 90 kOe. For the sample Ba{sub 8}Si{sub 42}Al{sub 4}, the critical magnetic fields were measured to be H{sub C1} = 40.2 Oe and H{sub C2} = 66.4 kOe. The London penetration depth of 4360 Å and the coherence length 70 Å were obtained, whereas the estimated Ginzburg–Landau parameter of κ = 62 revealed that Ba{sub 8}Si{sub 42}Al{sub 4} is a strong type-II superconductor.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Assessment of the degree of hydration of ocular surface tissues using THz reflectometry

Using the effective medium model, the complex permittivity of the ocular surface system in the THz frequency range is considered. The penetration depth of THz radiation and the sensitivity of the reflected component to the dynamics of evaporation of the tear film are discussed. The results of in vivo experiments aimed to determine the reflection coefficient of the ocular surface using continuous THz reflectometers are well described using the developed model. (paper)

36 MATERIALS SCIENCE↗

TOWARD A GLOBAL EVOLUTIONARY MODEL OF PROTOPLANETARY DISKS

A global picture of the evolution of protoplanetary disks (PPDs) is key to understanding almost every aspect of planet formation, where standard α-disk models have been continually employed for their simplicity. In the meantime, disk mass loss has been conventionally attributed to photoevaporation, which controls disk dispersal. However, a paradigm shift toward accretion driven by magnetized disk winds has taken place in recent years, thanks to studies of non-ideal magnetohydrodynamic effects in PPDs. I present a framework of global PPD evolution aiming to incorporate these advances, highlighting the role of wind-driven accretion and wind mass loss. Disk evolution is found to be largely dominated by wind-driven processes, and viscous spreading is suppressed. The timescale of disk evolution is controlled primarily by the amount of external magnetic flux threading the disks, and how rapidly the disk loses the flux. Rapid disk dispersal can be achieved if the disk is able to hold most of its magnetic flux during the evolution. In addition, because wind launching requires a sufficient level of ionization at the disk surface (mainly via external far-UV (FUV) radiation), wind kinematics is also affected by the FUV penetration depth and disk geometry. For a typical disk lifetime of a few million years, the disk loses approximately the same amount of mass through the wind as through accretion onto the protostar, and most of the wind mass loss proceeds from the outer disk via a slow wind. Fractional wind mass loss increases with increasing disk lifetime. Significant wind mass loss likely substantially enhances the dust-to-gas mass ratio and promotes planet formation.

79 ASTRONOMY AND ASTROPHYSICS↗

A COAXIAL TE011 CAVITY AND A SYSTEM TO MEASURE DC AND RF PROPERTIES OF SUPERCONDUCTORS

A coaxial niobium cavity has been designed and built where the center conductor consists of a removable sample. In addition, a system to measure properties such as magnetization, penetration depth, critical temperature and thermal conductivity on the same cylindrical sample has been designed and built. The purpose of this effort is to investigate possible correlations between DC and RF properties of superconductors. In this contribution, the design of the various components is discussed and the test results on a niobium sample obtained so far are presented.

36 MATERIALS SCIENCE↗

Analysis of 440 GeV proton beam–matter interaction experiments at the High Radiation Materials test facility at CERN

In a previous paper [Schmidt et al., Phys. Plasmas 21, 080701 (2014)], we presented the first results on beam–matter interaction experiments that were carried out at the High Radiation Materials test facility at CERN. In these experiments, extended cylindrical targets of solid copper were irradiated with beam of 440 GeV protons delivered by the Super Proton Synchrotron (SPS). The beam comprised of a large number of high intensity proton bunches, each bunch having a length of 0.5 ns with a 50 ns gap between two neighboring bunches, while the length of this entire bunch train was about 7 μs. These experiments established the existence of the hydrodynamic tunneling phenomenon the first time. Detailed numerical simulations of these experiments were also carried out which were reported in detail in another paper [Tahir et al., Phys. Rev. E 90, 063112 (2014)]. Excellent agreement was found between the experimental measurements and the simulation results that validate our previous simulations done using the Large Hadron Collider (LHC) beam of 7 TeV protons [Tahir et al., Phys. Rev. Spec. Top.--Accel. Beams 15, 051003 (2012)]. According to these simulations, the range of the full LHC proton beam and the hadronic shower can be increased by more than an order of magnitude due to the hydrodynamic tunneling, compared to that of a single proton. This effect is of considerable importance for the design of machine protection system for hadron accelerators such as SPS, LHC, and Future Circular Collider. Recently, using metal cutting technology, the targets used in these experiments have been dissected into finer pieces for visual and microscopic inspection in order to establish the precise penetration depth of the protons and the corresponding hadronic shower. This, we believe will be helpful in studying the very important phenomenon of hydrodynamic tunneling in a more quantitative manner. The details of this experimental work together with a comparison with the numerical simulations are presented in this paper.

36 MATERIALS SCIENCE↗

Modified theory of secondary electron emission from spherical particles and its effect on dust charging in complex plasma

The authors have modified Chow's theory of secondary electron emission (SEE) to take account of the fact that the path length of a primary electron in a spherical particle varies between zero to the diameter or x{sub m} the penetration depth depending on the distance of the path from the centre of the particle. Further by including this modified expression for SEE efficiency, the charging kinetics of spherical grains in a Maxwellian plasma has been developed; it is based on charge balance over dust particles and number balance of electrons and ionic species. It is seen that this effect is more pronounced for smaller particles and higher plasma temperatures. Desirable experimental work has also been discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrical and microstructure analysis of nickel-based low-resistance ohmic contacts to n-GaSb

Ultra low resistance ohmic contacts are fabricated on n-GaSb grown by molecular beam epitaxy. Different doping concentrations and n-GaSb thicknesses are studied to understand the tunneling transport mechanism between the metal contacts and the semiconductor. Different contact metallization and anneal process windows are investigated to achieve optimal penetration depth of Au in GaSb for low resistances. The fabrication, electrical characterization, and microstructure analysis of the metal-semiconductor interfaces created during ohmic contact formation are discussed. The characterization techniques include cross-sectional transmission electron microscopy and energy dispersive spectroscopy. Specific transfer resistances down to 0.1 Ω mm and specific contact resistances of 1 × 10{sup −6} Ω cm{sup 2} are observed.

36 MATERIALS SCIENCE↗

Statistics of avalanches in the self-organized criticality state of a Josephson junction

Magnetic flux avalanches in Josephson junctions that include superconductor-insulator-superconductor (SIS) tunnel junctions and are magnetized at temperatures lower than approximately 5 K have been studied in detail. Avalanches are of stochastic character and appear when the magnetic field penetration depth {lambda} into a junction becomes equal to the length a of the Josephson junction with a decrease in the temperature. The statistical properties of such avalanches are presented. The size distribution of the avalanches is a power law with a negative noninteger exponent about unity, indicating the self-organized criticality state. The self-organized criticality state is not observed in Josephson junctions with a superconductor-normal metal-superconductor (SNS) junction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Out-of-field Dose for Scanned and Scattered Proton Beams

The dose delivered outside of the primary field to non-target tissues is of concern in all types of radiotherapy. For a given radiation type, this dose is dependent upon the delivery technique. Proton beams may be spread laterally to cover the target volume using scattering foils or magnetic scanning. Although scattered beams always use apertures or multi-leaf collimators to limit the radiation to normal tissues, scanning beams may or may not use them. A direct comparison of out-of-field dose for different proton delivery techniques has been thwarted because no institution had, as of April 2008, used multiple delivery techniques and comparisons have had to make extrapolations from measurements or calculations made using different field sizes, ranges, modulations, collimator-to-skin distances, and collimator materials. In this study, the Monte Carlo program MCNPX was used to simulate the dose deposited outside of the primary field for scattered/collimated (STC), scanned/collimated (SNC), and scanned/uncollimated (SNU) beams that have the same field size and penetration depth within a simulated patient. The out-of-field doses ranged from 10{sup -2} to 10{sup -7} of the prescribed dose. The ratio of STC to SNU dose varied from 2 to 420 depending upon the depth and distance off-axis while the SNC to SNU dose varied from 1.2 to 140. As the out-of-field doses are very small for all beam delivery techniques, decisions regarding which technique is appropriate for a given patient or facility should be based upon the magnitude of the out-of-field dose per unit prescribed dose and other issues rather than the ratio of doses for the different beam delivery techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗