Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Observed On-Orbit Background of the ACIS Detector on the Chandra X-Ray Observatory

We have analyzed calibration data acquired during the Orbital Activation and Checkout (OAC) phase of the Chandra X-ray Observatory (CXO) mission in order to characterize the background of the Advanced CCD Imaging Spectrometer (ACIS) produced by charged particles and non-cosmic X-rays. The ACIS instrument contains 8 Front-Illuminated (FI) CCDs and 2 Back-Illuminated (BI) CCDs. The FI and BI CCD)s exhibit dramatically different responses to enhancements in the particle flux. The F1 CCDs show relatively little increase in the overall count rate, typical increases are 1 - 3 counts/s; the BI CCDs show large excursions to as high as 100 counts/s. The duration of these intervals of enhanced background are highly variable ranging from 100 s to 5000 s. The spatial distribution of these background events is relatively flat across the power-law. The events produce morphologies which are similar to cosmic X-ray events, so that morphology alone cannot be used as a rejection criterion. We explore the correlation of these times of high background with the data from Chandra's on-board radiation monitor, the EPHIN (Electron, Proton, Helium Instrument particle detector) instrument and archival data from the Advanced Composition Explorer (ACE) satellite. We discuss strategies for observers to identify and exclude times of high background and to model and subtract the background events from their data.

Plucinsky, P. P.↗

Chandra Observations of the Crab Pulsar as a Function of Pulse Phase

The Chandra X-Ray Observatory was used to observe the Crab Nebula and its pulsar using the LETGS, i.e. the Low-Energy Transmission Grating (LETG) with the High Resolution Camera Spectroscopy detector (HRC-S). Data from the zeroth-order image was utilized to isolate the pulsar from the surrounding nebula and to measure the pulsar emission as a function of pulse phase. HRC timing problems were overcome by developing special techniques to process the data. For the first time, pulsed x-ray emission has been detected at all pulse phases, allowing us to set a new upper limit to the thermal emission from the surface of the neutron star.

Weisskopf, Martin C.↗

Global Maps of Lunar Neutron Fluxes from the LEND Instrument

The latest neutron spectrometer measurements with the Lunar Exploration Neutron Detector (LEND) onboard the Lunar Reconnaissance Orbiter (LRO) are presented. It covers more than 1 year of mapping phase starting on 15 September 2009. In our analyses we have created global maps showing regional variations in the flux of thermal (energy range < 0.015 eV) and fast neutrons (>0.5 MeV), and compared these fluxes to variances in soil elemental composition, and with previous results obtained by the Lunar Prospector Neutron Spectrometer (LPNS). We also processed data from LEND collimated detectors and derived a value for the collimated signal of epithermal neutrons based on the comparative analysis with the LEND omnidirectional detectors. Finally, we have compared our final (after the data reduction) global epithermal neutron map with LPNS data.

Epithermal neutrons↗

LISA phase measurement technique

The LISA mission will form the equivalent of a Michelson interferometric beat signal from the 1064nm laser beams traversing the inter-spacecraft arms. The design gravitational wave sensitivity requires measurement of round trip path differences for each detector to be about 10 pddHz over a frequency range from 10^10-4 to 10^-1 Hz. Thus LISA'S phasemeter must measure the beat signal phase to 10^-5 cycle/square root of Hz at 1mHz. Doppler shifts between spacecraft in their orbits are expected to range from 1 to 15 MHz. Phase measurement using the digital phase-locked loop approach incorporated in a modified TurboRogue GPS receiver has been investigated in this study. It is found that only resolution in the range of 10^-4 to 10^-3 cycle/square root of Hz at 1 mHz is achievable with this hardware. Abrupt fluctuations in the phase measurement at the millicycle level are responsible for the limitation.

phasemeter↗

Circuit suppresses spurious sidebands

Circuitry requires modulated subcarrier to be split, part going to a phase modulator, and part going to a new circuit which utilizes a square law detector, a balanced mixer, and an amplifier to remove spurious sidebands. A summer recombines the two outputs, and final signal no longer includes spures.

Ready, P. J.↗

All-digital phase-lock loops for noise-free signals

Bit-synchronizers utilize all-digital phase-lock loops that are referenced to a high frequency digital clock. Phase-lock loop of first design acquires frequency within nominal range and tracks phase; second design is modified for random binary data by addition of simple transition detector; and third design acquires frequency over wide dynamic range.

Anderson, T. O.↗

Evidence that pitch angle scattering is an important loss mechanism for energetic electrons in the inner radiation belt of Jupiter

Analysis of data from the Pioneer 10 flyby discloses that pitch angle scattering plays an important part in determining the distribution of energetic electrons in the inner magnetosphere of Jupiter. Angular distributions measured by a Cerenkov detector reveal that redistribution takes place in pitch angle. Additionally, the radial profile of phase space density along the equator demands simultaneous particle losses. The loss rates are too high to be accounted for by synchrotron radiation loss, but are reasonably attributed to pitch angle scattering into the planetary loss cone.

Fillius, W.↗

Deferred electronic heterodyne moire deflectometry: A method for transient density fields measurement

Effects of spherical aberrations of the mirror used in the moire system on the angular resolution of the system are investigated. It is shown that the spherical aberrations may reduce significantly the performance of the conventional moire deflectometer. However, due to the heterodyne procedure, this is not the case with the heterodyne moire system. A moire system with a constant speed moving grating is demonstrated. It is shown that the system readout is linear and the system does not need calibration. In addition, the repeatability of the measurements is improved in this system as compared to the sinusoidally moving grating setup. The problem of the photographic plates alignment is solved by using a mechanical system in which the plate is held firmly throughout the experiment and accurately replaced after removing for photographic processing. The effect of a circular detector's aperture size on readout was tested. It is shown that the spatial phase variations, observed when scanning along a straight moire fringe, may considerably be reduced. At present we may say that both the on-line and the deferred heterodyne moire techniques may reliably be used. The errors of phase readings are 1 deg and 5 deg for the on-line and deferred methods. The total error due to subtraction of two readings at each position is, therefore, 1.4 deg and 7 deg, respectively. Further research for improving the deferred system is suggested.

Stricker, Josef↗

Ion flux oscillations associated with a radially polarized transverse Pc 5 magnetic pulsation

The AMPTE CCE spacecraft observed a transverse Pc 5 magnetic pulsation (period of about 200 s) at 2155-2310 UT on November 20, 1985, at a radial distance of 5.7 - 7.0 earth radii, at a magnetic latitude of 1.2 - 19 deg, and near 1300 magnetic local time. The magnetic pulsation exhibits properties consistent with a standing Alfven wave with a second-harmonic standing structure along the ambient magnetic field. The amplitude and the phase of the flux pulsation are found to be a function of the particle detector look direction and the particle energy. The observed energy dependence of the shift is interpreted as the result of a drift-bounce resonance of the ions with the wave. From this interpretation it follows that the wave propagated westward with an azimuthal wave number of approximately 100. Thus the study demonstrates that particle data can be useful for determining the spatial structure of some types of ULF waves.

Takahashi, K.↗

Surface roughness measurements

The Optics Division is currently in the research phase of producing grazing-incidence mirrors to be used in x-ray detector applications. The traditional method of construction involves labor-intensive glass grinding. This also culminates in a relatively heavy mirror. For lower resolution applications, the mirrors may be of a replicated design which involves milling a mandrel as a negative of the final shape and electroplating the cylindrical mirror onto it. The mirror is then separated from the mandrel by cooling. The mandrel will shrink more than the 'shell' (mirror) allowing it to be pulled from the mandrel. Ulmer (2) describes this technique and its variations in more detail. To date, several mirrors have been tested at MSFC by the Optical Fabrication Branch by focusing x-ray energy onto a detector with limited success. Little is known about the surface roughness of the actual mirror. Hence, the attempt to gather data on these surfaces. The test involves profiling the surface of a sample, replicating the surface as described above, and then profiling the replicated surface.

Howard, Thomas G.↗

Small Vocabulary Recognition Using Surface Electromyography in an Acoustically Harsh Environment

This paper presents results of electromyographic-based (EMG-based) speech recognition on a small vocabulary of 15 English words. The work was motivated in part by a desire to mitigate the effects of high acoustic noise on speech intelligibility in communication systems used by first responders. Both an off-line and a real-time system were constructed. Data were collected from a single male subject wearing a fireghter's self-contained breathing apparatus. A single channel of EMG data was used, collected via surface sensors at a rate of 104 samples/s. The signal processing core consisted of an activity detector, a feature extractor, and a neural network classifier. In the off-line phase, 150 examples of each word were collected from the subject. Generalization testing, conducted using bootstrapping, produced an overall average correct classification rate on the 15 words of 74%, with a 95% confidence interval of [71%, 77%]. Once the classifier was trained, the subject used the real-time system to communicate and to control a robotic device. The real-time system was tested with the subject exposed to an ambient noise level of approximately 95 decibels.

Betts, Bradley J.↗

LWIR detector research in InAsSb/InAs

The InAsSb/InSb strained-layer system forms a type-II superlattice in the Sb-rich region of the phase diagram. The band gap of InAsSb/InSb strained-layer superlattices grown on lattice-matched buffers can be varied continuously to produce semiconducting systems with band gaps ranging from that of InSb (0.23 eV with an absorption edge at 5.5 microns at 77 K) to 0. The semiconductor to semimetal transition occurs at As concentrations of approximately 33 percent, with the precise value dependent upon the strain and quantum well dimensions. At higher As content, the system is a semimetal. The authors fabricated photovoltaic detectors with high D asterisk at 77 K at wavelengths beyond 10 microns, and both photovoltaic and photoconductive detectors have been demonstrated with response to 15 microns. The photoconductive detectors exhibit gain of up to 100. Details of the materials growth, studies of the band structure and properties, device processing and the detector performance observed to date in these systems are discussed.

Peercy, Paul S.↗

Implementing a Digital Phasemeter in an FPGA

Firmware for implementing a digital phasemeter within a field-programmable gate array (FPGA) has been devised. In the original application of this firmware, the phase that one seeks to measure is the difference between the phases of two nominally-equal-frequency heterodyne signals generated by two interferometers. In that application, zero-crossing detectors convert the heterodyne signals to trains of rectangular pulses, the two pulse trains are fed to a fringe counter (the major part of the phasemeter) controlled by a clock signal having a frequency greater than the heterodyne frequency, and the fringe counter computes a time-averaged estimate of the difference between the phases of the two pulse trains. The firmware also does the following: Causes the FPGA to compute the frequencies of the input signals; Causes the FPGA to implement an Ethernet (or equivalent) transmitter for readout of phase and frequency values; and Provides data for use in diagnosis of communication failures. The readout rate can be set, by programming, to a value between 250 Hz and 1 kHz. Network addresses can be programmed by the user.

Rao, Shanti R.↗

X-Ray Polarization Capabilities of a Small Explorer Mission

X-ray polarization measurements hold great promise for studying the geometry and emission mechanisms in the strong gravitational and magnetic fields that surround black holes and neutron stars. In spite of this, the observational situation remains very limited; the last instrument dedicated to X-ray polarimetry flew decades ago on OSO-8, and the few recent measurements have been made by instruments optimized for other purposes. However, the technical capabilities to greatly advance the observational situation are in hand. Recent developments in micro-pattern gas detectors allow use of the polarization sensitivity of the photo-electric effect, which is the dominant interaction in the band above 2 keV. We present the scientific and technical requirements for an X-ray polarization observatory consistent with the scope of a NASA Small Explorer (SMEX) mission, along with a representative catalog of what the observational capabilities and expected sensitivities for the first year of operation could be. The mission is based on the technically robust design of the Gravity and Extreme Magnetism SMEX (GEMS) which completed a Phase B study and Preliminary Design Review in 2012. The GEMS mission is enabled by time projection detectors sensitive to the photo-electric effect. Prototype detectors have been designed, and provide engineering and performance data which support the mission design. The detectors are further characterized by low background, modest spectral resolution, and sub-millisecond timing resolution. The mission also incorporates high efficiency grazing incidence X-ray mirrors, design features that reduce systematic errors (identical telescopes at different azimuthal angles with respect to the look axis, and mounted on a rotating spacecraft platform), and a moderate capability to perform Target of Opportunity observations. The mission operates autonomously in a low earth, low inclination orbit with one to ten downlinks per day and one or more uplinks per week. Data and calibration products will be made available through the High Energy Astrophysics Science and Archival Research Center (HEASARC).

GEMS↗

Vapor Growth of Indium Monoiodide

Indium (I) iodide, InI, is part of a group of heavy metal iodides that can be used as room temperature radiation detectors. Other examples are HgI2, PbI2, BiI3, or TlPbI3. InI has several advantages, such as low toxicity, no solid phase transition (such as in HgI2), and no tendency to form polytypes (PbI2, BiI3 ). All binary iodides have layered structures and are quite soft, but InI is also the mechanically most stable compound of the binary compounds. Table 1 shows the main properties of InI in comparison with the other iodides and the most common room temperature radiation detector material, (Cd, Zn)Te. InI is typically grown by the unseeded Bridgman method using a nucleation tip, but Czochralski (CZ) growth has also been demonstrated. The resulting crystals have been used successfully for radiation detection, but both resistivity and mobility are usually well below theoretically predicted values. Physical vapor transport (PVT), although much slower than melt growth, is an alternative method and has been used to grow e.g. HgI2, PbI2, BiI3, CdTe. PVT growth should eliminate or reduce inclusions and impurities since it is based on sublimation, reduce intrinsic defects due to the lower growth temperature, and reduce dislocation densities due to reduced thermal and mechanical stress. As an example, PVT-grown CdTe showed a much improved structural quality compared to Bridgman- or THM-grown material.

Cröll, Arne↗

Test and Recommendation of Flight-forward Resistive Temperature Detector for Resource Prospector Mission

The Resource Prospector Mission (RPM) is an in-situ resource utilization (ISRU) technology demonstration mission planned to launch in 2018. The mission will use the Regolith and Environment Science & Oxygen and Lunar Volatile Extraction (RESOLVE) Payload to prospect for lunar volatiles such as water, oxygen, and carbon dioxide. These compounds will validate ISRU capability. The payload, particularly the Lunar Advanced Volatile Analysis (LAVA) subsystem, requires numerous temperature measurements to accurately control on-board heaters that keep the volatiles in the vapor phase to allow quantification and prevent the clogging of delivery lines. Previous spaceflight missions have proven that Resistive Temperature Detector (RTD) failure impedes mission success. The research resulted in a recommendation for a flight-forward RTD. The recommendation was based on accuracy, consistency, and ease of installation of RTDs procured from IST, QTI, and Honeywell.

LAVA↗

Test and Recommendation of Flight-Forward Resistive Temperature Detector for Resource Prospector Mission

The Resource Prospector Mission (RPM) is an in-situ resource utilization (ISRU) technology demonstration mission planned to launch in 2018. The mission will use the Regolith and Environment Science & Oxygen and Lunar Volatile Extraction (RESOLVE) Payload to prospect for lunar volatiles such as water, oxygen, and carbon dioxide. These compounds will validate ISRU capability. The payload, particularly the Lunar Advanced Volatile Analysis (LAVA) subsystem, requires numerous temperature measurements to accurately control on-board heaters that keep the volatiles in the vapor phase to allow quantification and prevent the clogging of delivery lines. Previous spaceflight missions have proven that Resistive Temperature Detector (RTD) failure impedes mission success. The research resulted in a recommendation for a flight-forward RTD. The recommendation was based on accuracy, consistency, and ease of installation of RTDs procured from IST, QTI, and Honeywell.

LAVA↗

Automatic carrier acquisition system

An automatic carrier acquisition system for a phase locked loop (PLL) receiver is disclosed. It includes a local oscillator, which sweeps the receiver to tune across the carrier frequency uncertainty range until the carrier crosses the receiver IF reference. Such crossing is detected by an automatic acquisition detector. It receives the IF signal from the receiver as well as the IF reference. It includes a pair of multipliers which multiply the IF signal with the IF reference in phase and in quadrature. The outputs of the multipliers are filtered through bandpass filters and power detected. The output of the power detector has a signal dc component which is optimized with respect to the noise dc level by the selection of the time constants of the filters as a function of the sweep rate of the local oscillator.

Bunce, R. C.↗