Search NASA⌕ Search

SEARCH · Search NASA

Results for “PIPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Design and test of a self-controlled heat pipe radiator.

A 15,000-W spacecraft waste heat rejection system utilizing heat pipe radiator panels has been investigated. Of the several concepts initially identified, a series system was selected for more in-depth analysis. As a demonstration of system feasibility, a nominal 500-W radiator panel has been designed, built, and bench tested. The panel, which is a module of the 15,000-W system, consists of a variable conductance heat pipe (VCHP) header, and six isothermalizer heat pipes attached to a radiator. The thermal load to the VCHP is supplied by a Freon 21 liquid loop via an integral heat exchanger. This paper describes the results of the system studies and the radiator design. Also presented are test data on the VCHP, heat exchanger and isothermalizer heat pipes.

Swerdling, B.↗

User's manual for the TRW gaspipe 2 program: A vapor-gas front analysis program for heat pipes containing non-condensible gas

A digital computer program for design and analysis of heat pipes which contain non-condensible gases, either for temperature control or to aid in start-up from the frozen state, is presented. Some of the calculations which are possible with the program are: (1) wall temperature profile along a gas-loaded heat pipe, (2) amount of gas loading necessary to obtain desired evaporator temperature at a desired heat load, (3) heat load versus evaporator temperature for a fixed amount of gas in the pipe, and (4) heat and mass transfer along the pipe, including the vapor-gas front region.

Edwards, D. K.↗

NASTRAN analysis of an air storage piping system

The application of NASTRAN to a complex piping design evaluation problem is summarized. Emphasis is placed on structural modeling aspects, problems encountered in modeling and analyzing curved pipe sections, principal results, and relative merits of using NASTRAN as a pipe analysis and design tool. In addition, the piping and manifolding system was analyzed with SNAP (Structural Network Analysis Program). The parallel SNAP study provides a basis for limited comparisons between NASTRAN and SNAP as to solution agreement and computer execution time and costs.

Young, C. P., Jr.↗

A homogeneous heat pipe design code

A computer program was developed to facilitate parametric performance evaluation of heat pipes in lightweight heat rejection systems. A description of the code, user's manual, and sample inputs are provided. The emphasis is placed on the analysis and design of homogeneous wick heat pipes. The analysis of the annular heat pipe is included as part of the heat pipe radiator subroutine.

Nakashima, A. M.↗

Heat pipe design handbook, part 2

The utilization of a digital computer code for heat pipe analysis and design (HPAD) is described which calculates the steady state hydrodynamic heat transport capability of a heat pipe with a particular wick configuration, the working fluid being a function of wick cross-sectional area. Heat load, orientation, operating temperature, and heat pipe geometry are specified. Both one 'g' and zero 'g' environments are considered, and, at the user's option, the code will also perform a weight analysis and will calculate heat pipe temperature drops. The central porous slab, circumferential porous wick, arterial wick, annular wick, and axial rectangular grooves are the wick configurations which HPAD has the capability of analyzing. For Vol. 1, see N74-22569.

Skrabek, E. A.↗

Electrohydrodynamic heat pipe experiments

Experiments with two electrohydrodynamic heat pipes are reported. Both devices employ an electromechanical flow structure for axial liquid flow and a capillary wicking structure for (1) collection of condensed liquid at the cooled end and (2) distribution of this liquid at the heated end. One device has circumferential grooving for the capillary structure and the other has feltmetal wicking. The experiments successfully demonstrate the electrohydrodynamic heat pipe concept. Compatibility of the two circumferential wick structures with an axial electromechanical flow structure is also demonstrated. A significant mismatch of the capillary groove and electrohydrodynamic pumping capabilities results in severe hydrodynamic burn-out limiting in the first heat pipe. Both devices have very poor over-all thermal conductances of the order of 1-2 W/deg C, reflecting the generally poor heat-transfer properties of the dielectric working fluids required in electrohydrodynamic heat pipes.

Jones, T. B.↗

Heat pipe manufacturing study

Heat pipe manufacturing methods are examined with the goal of establishing cost effective procedures that will ultimately result in cheaper more reliable heat pipes. Those methods which are commonly used by all heat pipe manufacturers have been considered, including: (1) envelope and wick cleaning, (2) end closure and welding, (3) mechanical verification, (4) evacuation and charging, (5) working fluid purity, and (6) charge tube pinch off. The study is limited to moderate temperature aluminum and stainless steel heat pipes with ammonia, Freon-21 and methanol working fluids. Review and evaluation of available manufacturers techniques and procedures together with the results of specific manufacturing oriented tests have yielded a set of recommended cost-effective specifications which can be used by all manufacturers.

Edelstein, F.↗

ERTS-C (Landsat 3) cryogenic heat pipe experiment definition

A flight experiment designed to demonstrate current cryogenic heat pipe technology was defined and evaluated. The experiment package developed is specifically configured for flight aboard an ERTS type spacecraft. Two types of heat pipes were included as part of the experiment package: a transporter heat pipe and a thermal diode heat pipe. Each was tested in various operating modes. Performance data obtained from the experiment are applicable to the design of cryogenic systems for detector cooling, including applications where periodic high cooler temperatures are experienced as a result of cyclic energy inputs.

Brennan, P. J.↗

Flat plate electrohydrodynamic heat pipe experiments

Performance capabilities of electrohydrodynamic (EHD) flat heat pipes were investigated using Freon 113 and Freon 11 as working fluids. All of the pipes employed straight rod electrodes to form axial liquid flow channels and tranverse grooves for capillary surface wetting. Results show: (1) the EHD pipe will prime under load, (2) voltage controlled conductance can be achieved by varying the active area of the evaporator, and (3) the average evaporator conductances measured in these experiments were consistent with those obtained in other experiments with heat pipes of similar surface geometry using the same or similar working fluids.

Loehrke, R. I.↗

Measurements of the performance of an electrohydrodynamic heat pipe

The performance of an electrohydrodynamic heat pipe formed by enclosing three straight axial electrodes with a 1.27 cm O.D. internally threaded stainless steel tube was measured with Freon-11 as working fluid. The condenser and evaporator conductances at low power were comparable to those measured in a conventional capillary driven heat pipe using similar working fluids. The evaporator conductance improved at high power probably due to the onset of nucleate boiling. The maximum heat throughput for this pipe was substantially higher than that of a conventional pipe.

Loehrke, R. I.↗

Analysis of fourth sounding rocket heat pipe experiment, summary report

An analysis was made of the cryogenic axial groove methane and axial groove nitrogen heat pipes. Data cover the establishment of reliable start-up and operational data for the cryogenic pipe and its reference control pipes, and requirements for and the applicability of cryogenic heat pipes to NASA coolers.

Brennan, P. J.↗

Flight data analysis and further development of variable-conductance heat pipes

Continuing efforts in large gains in heat-pipe performance are reported. It was found that gas-controlled variable-conductance heat pipes can perform reliably for long periods in space and effectively provide temperature stabilization for spacecraft electronics. A solution was formulated that allows the control gas to vent through arterial heat-pipe walls, thus eliminating the problem of arterial failure under load, due to trace impurities of noncondensable gas trapped in an arterial bubble during priming. This solution functions well in zero gravity. Another solution was found that allows priming at a much lower fluid charge. A heat pipe with high capacity, with close temperature control of the heat source and independent of large variations in sink temperature was fabricated.

Enginer, J. E.↗

Heat pipe radiators for space

Analysis of the data heat pipe radiator systems tested in both vacuum and ambient environments was continued. The systems included (1) a feasibility VCHP header heat-pipe panel, (2) the same panel reworked to eliminate the VCHP feature and referred to as the feasibility fluid header panel, and (3) an optimized flight-weight fluid header panel termed the 'prototype.' A description of freeze-thaw thermal vacuum tests conducted on the feasibility VCHP was included. In addition, the results of ambient tests made on the feasibility fluid header are presented, including a comparison with analytical results. A thermal model of a fluid header heat pipe radiator was constructed and a computer program written. The program was used to make a comparison of the VCHP and fluid-header concepts for both single and multiple panel applications. The computer program was also employed for a parametric study, including optimum feeder heat pipe spacing, of the prototype fluid header.

Sellers, J. P.↗

Investigation of performance limits in axial groove heat pipes

The entrainment-shear performance limit which occurs in axial groove heat pipes was investigated and explained. In the existing heat pipe literature the entrainment heat flux limit is defined as the condition where the Weber number is greater than or equal to one. In this analysis, the critical value for the entrainment Weber number is found to be 2 pi less than or equal to 3 pi. Perhaps more important to the heat pipe designer than the entrainment performance limit is the prediction of the performance degradation due to vapor-liquid shearing stress which is also described. Preliminary qualitative experiments were conducted to observe the shear. stress wave formation phenomena. The equations presented may be used to predict and minimize the vapor-liquid shear stress performance effects that occur in axial groove and puddle flow artery heat pipes.

Feldman, K. T.↗

Heat Pipe Materials Compatibility

An experimental program to evaluate noncondensable gas generation in ammonia heat pipes was completed. A total of 37 heat pipes made of aluminum, stainless steel and combinations of these materials were processed by various techniques, operated at different temperatures and tested at low temperature to quantitatively determine gas generation rates. In order of increasing stability are aluminum/stainless combination, all aluminum and all stainless heat pipes. One interesting result is the identification of intentionally introduced water in the ammonia during a reflux step as a means of surface passivation to reduce gas generation in stainless-steel/aluminum heat pipes.

Eninger, J. E.↗

Thermodynamic analysis of alternate energy carriers, hydrogen and chemical heat pipes

Hydrogen and chemical heat pipes were proposed as methods of transporting energy from a primary energy source (nuclear, solar) to the user. In the chemical heat pipe system, primary energy is transformed into the energy of a reversible chemical reaction; the chemical species are then transmitted or stored until the energy is required. Analysis of thermochemical hydrogen schemes and chemical heat pipe systems on a second law efficiency or available work basis show that hydrogen is superior especially if the end use of the chemical heat pipe is electrical power.

Cox, K. E.↗

Flexible Cryogenic Heat Pipe Development Program

A heat pipe was designed for operation in the 100 - 200 K temperature range with maximum heat transport as a primary design goal; another designed for operation in the 15 - 100 K temperature range with maximum flexibility as a design goal. Optimum geometry and materials for the container and wicking systems were determined. The high power (100 - 200 K) heat pipe was tested with methane at 100 - 140 K, and test data indicated only partial priming with a performance limit of less than 50 percent of theoretical. A series of tests were conducted with ammonia at approximately 280 K to determine the performance under varying fluid charge and test conditions. The low temperature heat pipe was tested with oxygen at 85 - 95 K and with methanol at 295 - 315 K. Performance of the low temperature heat pipe was below theoretical predictions. Results of the completed testing are presented and possible performance limitation mechanisms are discussed. The lower-than-expected performance was felt to be due to small traces of non-condensible gases which prevented the composite wick from priming.

Source record↗

Effects of one-sided heat input and removal on axially grooved heat pipe performance

The performance of an axially grooved heat pipe with one-sided heat input and removal was investigated analytically. Under zero-g condition the maximum heat transport of the pipe may decrease as much as 30% depending on the liquid slug behavior in the condenser section. In one-g environment the performance depends mainly on the fluid charge. The maximum heat transport, if over-charged, is almost equal to the value for uniform heating and cooling due to puddling effect. However, for some heater-cooler combinations the temperature drop across the heat pipe becomes very large. Computed results for tilted heat pipes compare favorably with available experimental data.

Kamotani, Y.↗