Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Independent calculation-based verification of IMRT plans using a 3D dose-calculation engine

Independent monitor unit verification of intensity-modulated radiation therapy (IMRT) plans requires detailed 3-dimensional (3D) dose verification. The aim of this study was to investigate using a 3D dose engine in a second commercial treatment planning system (TPS) for this task, facilitated by in-house software. Our department has XiO and Pinnacle TPSs, both with IMRT planning capability and modeled for an Elekta-Synergy 6 MV photon beam. These systems allow the transfer of computed tomography (CT) data and RT structures between them but do not allow IMRT plans to be transferred. To provide this connectivity, an in-house computer programme was developed to convert radiation therapy prescription (RTP) files as generated by many planning systems into either XiO or Pinnacle IMRT file formats. Utilization of the technique and software was assessed by transferring 14 IMRT plans from XiO and Pinnacle onto the other system and performing 3D dose verification. The accuracy of the conversion process was checked by comparing the 3D dose matrices and dose volume histograms (DVHs) of structures for the recalculated plan on the same system. The developed software successfully transferred IMRT plans generated by 1 planning system into the other. Comparison of planning target volume (TV) DVHs for the original and recalculated plans showed good agreement; a maximum difference of 2% in mean dose, − 2.5% in D95, and 2.9% in V95 was observed. Similarly, a DVH comparison of organs at risk showed a maximum difference of +7.7% between the original and recalculated plans for structures in both high- and medium-dose regions. However, for structures in low-dose regions (less than 15% of prescription dose) a difference in mean dose up to +21.1% was observed between XiO and Pinnacle calculations. A dose matrix comparison of original and recalculated plans in XiO and Pinnacle TPSs was performed using gamma analysis with 3%/3 mm criteria. The mean and standard deviation of pixels passing gamma tolerance for XiO-generated IMRT plans was 96.1 ± 1.3, 96.6 ± 1.2, and 96.0 ± 1.5 in axial, coronal, and sagittal planes respectively. Corresponding results for Pinnacle-generated IMRT plans were 97.1 ± 1.5, 96.4 ± 1.2, and 96.5 ± 1.3 in axial, coronal, and sagittal planes respectively.

61 RADIATION PROTECTION AND DOSIMETRY↗

Observation of B$^0_s$ mesons and measurement of the B$^0_s$/B$^+$ yield ratio in PbPb collisions at $\sqrt{s_\mathrm{NN}}$ = 5.02 TeV

The B$^0_s$ and B$^+$ production yields are measured in PbPb collisions at a center-of-mass energy per nucleon pair of 5.02 TeV. The data sample, collected with the CMS detector at the LHC, corresponds to an integrated luminosity of 1.7 nb$^{-1}$. The mesons are reconstructed in the exclusive decay channels B$^0_s$$\to$ J/$\psi(\mu^+\mu^-)\phi($K$^+$K$^-)$ and B$^+$$\to$ J/$\psi(\mu^+\mu^-)$K$^+$. The B$^0_s$ meson is observed with a statistical significance in excess of five standard deviations for the first time in nucleus-nucleus collisions. The measurements are performed as functions of the transverse momentum of the B mesons and of the PbPb collision centrality. The ratio of production yields of B$^0_s$ and B$^+$ is measured and compared to theoretical models that include quark recombination effects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterising the Higgs boson with ATLAS data from the LHC Run-2

The Higgs boson was discovered by the ATLAS and CMS Collaborations in 2012 using data from Run 1 of the Large Hadron Collider (2010 2012). In Run 2 (2015 2018), about 140 fb -1 of proton–proton collisions at a centre-of-mass energy of 13 TeV were collected by the ATLAS experiment. This review presents the most important Run 2 results obtained by the ATLAS Collaboration regarding the properties of the Higgs boson and its interactions with other particles. The performed studies significantly enhance the understanding of the Higgs boson, while hunting for deviations from the predictions of the Standard Model of particle physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dipole Moment Calculations Using Multiconfiguration Pair-Density Functional Theory and Hybrid Multiconfiguration Pair-Density Functional Theory

The dipole moment is the molecular property that most directly indicates molecular polarity. The accuracy of computed dipole moments depends strongly on the quality of the calculated electron density, and the breakdown of single-reference methods for strongly correlated systems can lead to poor predictions of the dipole moments in those cases. Here, we derive the analytical expression for obtaining the electric dipole moment by multiconfiguration pair density functional theory (MCPDFT), and we assess the accuracy of MC-PDFT for predicting dipole moments at equilibrium and nonequilibrium geometries. We show that MC-PDFT dipole moment curves have reasonable behavior even for stretched geometries, and they significantly improve upon the CASSCF results by capturing more electron correlation. Herein, the analysis of a dataset consisting of 18 first-row transition metal diatomics and 6 main-group polyatomic molecules with multireference character suggests that MC-PDFT and its hybrid extension (HMC-PDFT) perform comparably to CASPT2 and MRCISD+Q methods and have a mean unsigned deviation of 0.2–0.3 D with respect to the best available dipole moment reference values. We explored the dependence of the predicted dipole moments upon the choice of the on-top density functional and active space, and we recommend the tPBE and hybrid tPBE0 on-top choices for the functionals combined with the moderate correlated participating orbital scheme for selecting the active space. With these choices, the mean unsigned deviations (in debyes) of the calculated equilibrium dipole moments from the best estimates are 0.77 for CASSCF, 0.29 for MC-PDFT, 0.24 for HMCPDFT, 0.28 for CASPT2, and 0.25 for MRCISD+Q. These results are encouraging because the computational cost of MC-PDFT or HMC-PDFT is largely reduced compared to the CASPT2 and MRCISD+Q methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Predicting third-body collision efficiencies for water and other polyatomic baths

Low-pressure-limit microcanonical (collisional activation) and thermal rate constants are predicted using a combination of automated ab initio potential energy surface construction, classical trajectories, transition state theory, and a detailed energy- and angular-momentum-resolved collision kernel. Several systems are considered, including CH 4 (+M) and HO 2 (+M), with an emphasis on systems where experimental information is available for comparison. The a priori approach involves no adjustable parameters, and we show that the predicted thermal rate constants are in excellent agreement with experiments, with average deviations of less than 25%. Notably, the a priori approach is shown to perform equally well for atomic, diatomic, and polyatomic baths, including M = H 2 O, CO 2 , and “fuel” baths like M = CH 4 and NH 3 . Additionally, the utility of microcanonical rate constants for interpreting trends and inferring mechanistic details in the thermal kinetics is demonstrated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Variable gamma-ray sky at 1 GeV

We search for the long-term variability of the gamma-ray sky in the energy range E > 1 GeV with 168 weeks of the gamma-ray telescope Fermi-LAT data. We perform a full sky blind search for regions with variable flux looking for deviations from uniformity. We bin the sky into 12288 pixels using the HEALPix package and use the Kolmogorov-Smirnov test to compare weekly photon counts in each pixel with the constant flux hypothesis. The weekly exposure of Fermi-LAT for each pixel is calculated with the Fermi-LAT tools. We consider flux variations in a pixel significant if the statistical probability of uniformity is less than 4 Multiplication-Sign 10{sup -6}, which corresponds to 0.05 false detections in the whole set. We identified 117 variable sources, 27 of which have not been reported variable before. The sources with previously unidentified variability contain 25 active galactic nuclei (AGN) belonging to the blazar class (11 BL Lacs and 14 FSRQs), one AGN of an uncertain type, and one pulsar PSR J0633+1746 (Geminga).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hybrid SOFC-Turbogenerator for Aircraft (Final Scientific/Technical Report)

The following paragraphs provide a high-level summary of the work performed during Phases I and II of this contract. Note that the order deviates from the WBS in places to better reflect the actual sequence of activities and the connections between them. Corresponding task numbers in the WBS are provided in parentheses after the task titles. There are a total of thirteen (13) tasks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

One Million Open-source Cislunar Orbits

Cislunar space, encompassing the region from geosynchronous orbit to beyond the Moon, is poised to become a cornerstone for future exploration, scientific discovery, and national security. Missions in this region, spanning durations from weeks to decades, require robust infrastructure and reliable transit capabilities. The complex gravitational influences of the Moon, Sun, and planets, along with thermal radiation from Earth and the Sun, lead to significant trajectory deviations, resulting in kilometer-scale errors within days. Leveraging the high-performance computing resources at Lawrence Livermore National Laboratory (LLNL), we have simulated one million high-fidelity cislunar trajectories, now publicly available via LLNL’s Green Data Oasis and the Unified Data Library. Generated using the open-source Space Situational Awareness Python package, these trajectories match the precision of commercial tools such as AGI’s Systems Tool Kit and NASA’s General Mission Analysis Tool. This data set is a valuable resource for reference, statistical analysis of cislunar orbit populations, and training machine learning models for rapid orbit classification with minimal observational input. Preliminary analysis reveals stable bands in Keplerian element space, particularly around five geosynchronous radii across a range of inclinations and eccentricities. Beyond this threshold, the Moon’s influence disrupts most unassisted orbits, though co-orbiting L4/L5 Lunar Trojans persist throughout the six-year simulation.

Astronomy and AstroPhysics↗

Real-time method for establishing a detection map for a network of sensors

A method for establishing a detection map of a dynamically configurable sensor network. This method determines an appropriate set of locations for a plurality of sensor units of a sensor network and establishes a detection map for the network of sensors while the network is being set up; the detection map includes the effects of the local terrain and individual sensor performance. Sensor performance is characterized during the placement of the sensor units, which enables dynamic adjustment or reconfiguration of the placement of individual elements of the sensor network during network set-up to accommodate variations in local terrain and individual sensor performance. The reconfiguration of the network during initial set-up to accommodate deviations from idealized individual sensor detection zones improves the effectiveness of the sensor network in detecting activities at a detection perimeter and can provide the desired sensor coverage of an area while minimizing unintentional gaps in coverage.

47 OTHER INSTRUMENTATION↗

The muon g-2 experiment at Fermilab

A new measurement of the anomalous magnetic moment of the muon, $a_{\mu} \equiv (g-2)/2$, will be performed at the Fermi National Accelerator Laboratory with data taking beginning in 2017. The most recent measurement, performed at Brookhaven National Laboratory and completed in 2001, shows a 3.5 standard deviation discrepancy with the standard model prediction of $a_\mu$. The new measurement will accumulate 21 times those statistics using upgraded detection and storage ring systems, enabling a measurement of $a_\mu$ to 140 ppb, a factor of 4 improvement in the uncertainty the previous measurement. This improvement in precision, combined with recent and ongoing improvements in the evaluation of the QCD contributions to the $a_\mu$, could provide a 7.5$\sigma$ discrepancy from the standard model if the current difference between experiment and theory is confirmed, a possible indication of new physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automated Assembly Progress Monitoring in Modular Construction Factories Using Computer Vision-Based Instance Segmentation

Modular construction has recently gained interest as a transformative construction method. In this method, a large portion of the construction is performed inside factories, where processes are fast-paced and interdependent; therefore, any deviation from the schedule can delay the production. Such deviations are frequent in modular factories due to the labor-intensive nature of the tasks. This propagation of delays can be mitigated by continuously monitoring each process; however, current manual monitoring methods are laborious, and recently proposed contact sensor-based methods are intrusive to the work. In addition, recent computer vision-based monitoring methods inside factories are limited to detection algorithms that fail to provide the pixel-level accuracy required for assembly progress monitoring in highly occluded factory scenes, and they require a large number of manual annotations. Therefore, this paper proposes a method to monitor the installation of subassemblies in modular construction factories using mask R-CNN instance segmentation and improves the data efficiency of the model using a copy-paste augmentation method. This method was validated on the CCTV videos captured from a modular construction factory in the US, resulting in a 9% mAP improvement in segmentation.

computer vision↗

Sensitivities and correlations of critical experiments due to uncertainties of system parameters and nuclear data - 14416

With increasing demand on accuracy of criticality calculations, correlations between benchmark experiments due to system parameter uncertainties become of interest in bias determination. The impact of different interpretations of system parameter uncertainties on the calculation of covariances and correlations of k{sub eff} is discussed in this article. Following the suggestion of the OECD/NEA EGUACSA Benchmark phase IV [1], 21 experiments from the ICSBEP international Handbook of Evaluated Criticality Safety Benchmarks [2] are used for this analysis (LEU-COMP-THERM series 07, exp. 01-04 and 39, exp. 01-17). The experiments share certain assembly and fuel features and were carried out in the same lab. Therefore, correlations in the calculation of k{sub eff} appear. Correlation coefficients between experiments due to nuclear data uncertainties are calculated with TSUNAMI [3] and show high values for most experiments. For the correlation analysis due to system parameter uncertainties mainly two scenarios are considered: In scenario A all uncertain parameters are varied mutually for all fuel rods, representing a systematic deviation of the actual experimental setup from the design value. This analysis is performed for all experiments listed above. In scenario E certain parameters like the outer cladding diameter are varied for each fuel rod individually, representing a random scattering of the varied parameter. Scenarios B, C and D represent intermediate scenarios between A and E, which are discussed shortly. Uncertainty and sensitivity calculations of k{sub eff} on the uncertain experimental parameters based on Monte Carlo sampling are presented and discussed. The calculations were performed with SUnCISTT (Sensitivities and Uncertainties in Criticality Inventory and Source Term Tool [4]) and SCALE 6.1.2 [3]. For the 21 EGUACSA proposed experiments the outer cladding diameter is the leading effect for the uncertainty of k{sub eff} for scenario A. In contrast, for scenario E the impact of the cladding diameter on k{sub eff} cancels out due to rod wise variations leaving the fuel diameter as the leading effect. The correlation analysis based on system parameter uncertainties indicates a significant dependence of the correlation coefficients on the interpretation of the uncertainties. It shows high values for scenario A, if the neutronic features are similar (EALF, H/U). For scenario E the overall correlations are significantly smaller and variations between experiments decrease. The impact of the determined correlations on bias calculations of application cases will be discussed by the authors in the accompanying paper 'Impact of correlated data in validation procedures'. (authors)

42 ENGINEERING↗

Megavoltage Computed Tomography Image Guidance With Helical Tomotherapy in Patients With Vertebral Tumors: Analysis of Factors Influencing Interobserver Variability

Purpose: To evaluate megavoltage computed tomography (MVCT)-based image guidance with helical tomotherapy in patients with vertebral tumors by analyzing factors influencing interobserver variability, considered as quality criterion of image guidance. Methods and Materials: Five radiation oncologists retrospectively registered 103 MVCTs in 10 patients to planning kilovoltage CTs by rigid transformations in 4 df. Interobserver variabilities were quantified using the standard deviations (SDs) of the distributions of the correction vector components about the observers' fraction mean. To assess intraobserver variabilities, registrations were repeated after {>=}4 weeks. Residual deviations after setup correction due to uncorrectable rotational errors and elastic deformations were determined at 3 craniocaudal target positions. To differentiate observer-related variations in minimizing these residual deviations across the 3-dimensional MVCT from image resolution effects, 2-dimensional registrations were performed in 30 single transverse and sagittal MVCT slices. Axial and longitudinal MVCT image resolutions were quantified. For comparison, image resolution of kilovoltage cone-beam CTs (CBCTs) and interobserver variability in registrations of 43 CBCTs were determined. Results: Axial MVCT image resolution is 3.9 lp/cm. Longitudinal MVCT resolution amounts to 6.3 mm, assessed as full-width at half-maximum of thin objects in MVCTs with finest pitch. Longitudinal CBCT resolution is better (full-width at half-maximum, 2.5 mm for CBCTs with 1-mm slices). In MVCT registrations, interobserver variability in the craniocaudal direction (SD 1.23 mm) is significantly larger than in the lateral and ventrodorsal directions (SD 0.84 and 0.91 mm, respectively) and significantly larger compared with CBCT alignments (SD 1.04 mm). Intraobserver variabilities are significantly smaller than corresponding interobserver variabilities (variance ratio [VR] 1.8-3.1). Compared with 3-dimensional registrations, 2-dimensional registrations have significantly smaller interobserver variability in the lateral and ventrodorsal directions (VR 3.8 and 2.8, respectively) but not in the craniocaudal direction (VR 0.75). Conclusion: Tomotherapy image guidance precision is affected by image resolution and residual deviations after setup correction. Eliminating the effect of residual deviations yields small interobserver variabilities with submillimeter precision in the axial plane. In contrast, interobserver variability in the craniocaudal direction is dominated by the poorer longitudinal MVCT image resolution. Residual deviations after image guidance exist and need to be considered when dose gradients ultimately achievable with image guided radiation therapy techniques are analyzed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of radiation dose and reconstruction algorithm in MDCT assessment of airway wall thickness: A phantom study

Purpose: Wall thickness (WT) is an airway feature of great interest for the assessment of morphological changes in the lung parenchyma. Multidetector computed tomography (MDCT) has recently been used to evaluate airway WT, but the potential risk of radiation-induced carcinogenesis—particularly in younger patients—might limit a wider use of this imaging method in clinical practice. The recent commercial implementation of the statistical model-based iterative reconstruction (MBIR) algorithm, instead of the conventional filtered back projection (FBP) algorithm, has enabled considerable radiation dose reduction in many other clinical applications of MDCT. The purpose of this work was to study the impact of radiation dose and MBIR in the MDCT assessment of airway WT. Methods: An airway phantom was scanned using a clinical MDCT system (Discovery CT750 HD, GE Healthcare) at 4 kV levels and 5 mAs levels. Both FBP and a commercial implementation of MBIR (Veo{sup TM}, GE Healthcare) were used to reconstruct CT images of the airways. For each kV–mAs combination and each reconstruction algorithm, the contrast-to-noise ratio (CNR) of the airways was measured, and the WT of each airway was measured and compared with the nominal value; the relative bias and the angular standard deviation in the measured WT were calculated. For each airway and reconstruction algorithm, the overall performance of WT quantification across all of the 20 kV–mAs combinations was quantified by the sum of squares (SSQs) of the difference between the measured and nominal WT values. Finally, the particular kV–mAs combination and reconstruction algorithm that minimized radiation dose while still achieving a reference WT quantification accuracy level was chosen as the optimal acquisition and reconstruction settings. Results: The wall thicknesses of seven airways of different sizes were analyzed in the study. Compared with FBP, MBIR improved the CNR of the airways, particularly at low radiation dose levels. For FBP, the relative bias and the angular standard deviation of the measured WT increased steeply with decreasing radiation dose. Except for the smallest airway, MBIR enabled significant reduction in both the relative bias and angular standard deviation of the WT, particularly at low radiation dose levels; the SSQ was reduced by 50%–96% by using MBIR. The optimal reconstruction algorithm was found to be MBIR for the seven airways being assessed, and the combined use of MBIR and optimal kV–mAs selection resulted in a radiation dose reduction of 37%–83% compared with a reference scan protocol with a dose level of 1 mGy. Conclusions: The quantification accuracy of airway WT is strongly influenced by radiation dose and reconstruction algorithm. The MBIR algorithm potentially allows the desired WT quantification accuracy to be achieved with reduced radiation dose, which may enable a wider clinical use of MDCT for the assessment of airway WT, particularly for younger patients who may be more sensitive to exposures with ionizing radiation.

60 APPLIED LIFE SCIENCES↗

Influence of particle size on NIR spectroscopic characterization of sorghum biomass for the biofuel industry

NIR spectroscopy is a rapid and accurate green technology for high-throughput biomass characterization, including sorghum (Sorghum bicolor), a promising energy crop for the biofuel industry. This study assessed the influence of particle size on NIR spectroscopic analysis (wavelength range: 867–2535 nm) of sorghum biomass composition. Grown under field conditions, a total of 113 types of genetically diverse sorghum accessions were dried, ground, and sieved (<250, 250–600, 600–850, and > 850 µm particle size) for developing partial least square regression (PLSR) prediction models for moisture, ash, extractive, glucan, xylan, acid-soluble lignin (ASL), acid-insoluble lignin (AIL), and total lignin (ASL + AIL). Overall, smaller particle sizes provided better model performance, while no single particle size provided the best performance for all the selected components. With only 9 selected bands and 4 latent variables (LVs), the best PLSR model was obtained for moisture with particle size of 600–850 µm with the square root of the coefficient of determination (R) of 0.85, the ratio of prediction to deviation (RPD) of 2.2, and the root mean square error (RMSE) of 0.46 % in external validation. Similar model performances were also obtained for ash, extractive, glucan, and xylan. This study showed that size reduction could effectively improve NIR spectroscopic analysis for lipid-producing sorghum biomass for the biofuel industry.

09 BIOMASS FUELS↗

Data for Influence of Particle Size on NIR Spectroscopic Characterization of Sorghum Biomass for the Biofuel Industry

NIR spectroscopy is a rapid and accurate green technology for high-throughput biomass characterization, including sorghum ( Sorghum bicolor ), a promising energy crop for the biofuel industry. This study assessed the influence of particle size on NIR spectroscopic analysis (wavelength range: 867–2535 nm) of sorghum biomass composition. Grown under field conditions, a total of 113 types of genetically diverse sorghum accessions were dried, ground, and sieved (<250, 250–600, 600–850, and > 850 µm particle size) for developing partial least square regression (PLSR) prediction models for moisture, ash, extractive, glucan, xylan, acid-soluble lignin (ASL), acid-insoluble lignin (AIL), and total lignin (ASL + AIL). Overall, smaller particle sizes provided better model performance, while no single particle size provided the best performance for all the selected components. With only 9 selected bands and 4 latent variables (LVs), the best PLSR model was obtained for moisture with particle size of 600–850 µm with the square root of the coefficient of determination (R) of 0.85, the ratio of prediction to deviation (RPD) of 2.2, and the root mean square error (RMSE) of 0.46 % in external validation. Similar model performances were also obtained for ash, extractive, glucan, and xylan. This study showed that size reduction could effectively improve NIR spectroscopic analysis for lipid-producing sorghum biomass for the biofuel industry.

Biomass Analytics↗

Performance of a Robotic Assistance Device in Computed Tomography-Guided Percutaneous Diagnostic and Therapeutic Procedures

PurposeTo evaluate a commercially available robotic assistance device for computed tomography-guided diagnostic and therapeutic interventions, compared to regular, manually performed CT scan-guided interventions in terms of precision, exposure to radiation to the patient and intervention time.Materials and MethodsOver a period of 6 months, 55 consecutive patients were recruited and treated using robotic assistance and compared to a control group of 101 patients previously treated with a regular CT scan-guided, manual approach. Evaluated parameters were precision (deviation from planned target and number of needle replacements), radiation exposure to the patient and intervention time. Evaluations were performed with regard to complexity (in-plane vs out-of-plane interventions) and type of anesthesia (general vs local).ResultsParameters related to precision were in general significantly better in the robotic assistance group (p < 0.01) with a mean deviation of 1.2 mm (± 1.6 mm) compared to 2.6 mm (± 1.1 mm) in the comparison group. Compared to manual procedure, the mean intervention time was reduced by 15 min (± 5.4 min) on average for an out-of-plane needle placement in the robotic group. There was no increase of exposure to radiation to the patient while radiation exposure for the physician was reduced to zero when the navigation system was used.ConclusionCompared to manual placement, the use of a robotic assistance device in out-of-plane CT-guided interventions under general anesthesia allows for probe placement with high precision. Intervention time is reduced with no increase of exposure to radiation to the patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Statistical analysis of spatial distribution of pores in metal additive manufacturing

We report mechanical properties of additively manufactured parts are sensitive to the presence of pores form during the manufacturing process. The impact of pores on the mechanical performance has been investigated extensively with respect to different parameters, such as pore volume fraction, shape, and size. However, statistical investigations focusing on the relationships between the spatial distribution of pores and process parameters; and consequently, the performance of the manufactured parts are scattered and limited. Also, these sparse investigations usually suffer from an ambiguous definition of terminologies. For instance, the required criteria to consider a point pattern as complete spatial randomness (CSR) are generally not clarified. Moreover, no numerical formalism is yet developed to show how much the observed spatial results are statistically significant. To address these shortcomings, the statistical definition of CSR in a point pattern and the procedure to quantitatively determine the deviation of a pattern from CSR were discussed. The explained statistical approach was used to investigate the effect of scanning speed parameter on the spatial distribution of gas pores in laser powder bed fusion manufactured stainless steel parts. Furthermore, and to highlight the impact of the spatial distribution of pores on mechanical properties, fatigue performances of parts with clustered and randomly distributed pores were simulated by finite element analysis. It is shown that by reducing the scanning speed, the spatial distribution of gas pores deviated more from CSR, and correspondingly fatigue performance deteriorated.

36 MATERIALS SCIENCE↗