Search NASA⌕ Search

SEARCH · Search NASA

Results for “Photonic systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Monolithic AlScN/SiC phononic waveguides for scalable acoustoelectric and quantum devices

Unlike conventional surface acoustic wave devices, phononic waveguide systems enable higher circuit density and stronger strain and piezoelectric fields, making them promising for advanced acoustoelectric and quantum applications. One such material system for generating and guiding phonons at gigahertz frequencies is AlScN on SiC, which can be synthesized by sputter depositing AlScN directly onto SiC wafers. The AlScN on the SiC platform allows for tightly vertically-confined acoustic modes with high electromechanical coupling, high speed of sound, and simple fabrication of strip and rib waveguides. Until now, this system has only been studied as a slab waveguide platform, i.e., without any lateral waveguiding. Here, we demonstrate a two-dimensionally confined phononic architecture in AlScN on SiC that supports guided modes at 2.95 and 4.05 GHz. These modes exhibit strong electromechanical coupling coefficients (k 2 = 4.27%) and propagation losses on the order of 10 dB/mm. Furthermore, this architecture is well-suited for phononic routing and power-efficient active or nonlinear devices such as amplifiers, mixers, and oscillators, and is compatible with the integration of quantum systems, including vacancy centers, charge carriers, photons, and spins, either embedded in SiC or heterogeneously integrated on the surface.

Electrical components↗

Light-sheet autofluorescence lifetime imaging with a single-photon avalanche diode array

Significance: Fluorescence lifetime imaging microscopy (FLIM) of the metabolic co-enzyme nicotinamide adenine dinucleotide (phosphate) [NAD(P)H] is a popular method to monitor single-cell metabolism within unperturbed, living 3D systems. However, FLIM of NAD(P)H has not been performed in a light-sheet geometry, which is advantageous for rapid imaging of cells within live 3D samples. Aim: We aim to design, validate, and demonstrate a proof-of-concept light-sheet system for NAD(P)H FLIM. Approach: A single-photon avalanche diode camera was integrated into a light sheet microscope to achieve optical sectioning and limit out-of-focus contributions for NAD(P)H FLIM of single cells. Results: An NAD(P)H light-sheet FLIM system was built and validated with fluores cence lifetime standards and with time-course imaging of metabolic perturbations in pancreas cancer cells with 10 s integration times. NAD(P)H light-sheet FLIM in vivo was demonstrated with live neutrophil imaging in a larval zebrafish tail wound also with 10 s integration times. Finally, the theoretical and practical imaging speeds for NAD(P)H FLIM were compared across laser scanning and light-sheet geometries, indicating a 30× to 6× acquisition speed advantage for the light sheet compared to the laser scanning geometry. Conclusions: FLIM of NAD(P)H is feasible in a light-sheet geometry and is attrac tive for 3D live cell imaging applications, such as monitoring immune cell metabolism and migration within an organism.

47 OTHER INSTRUMENTATION↗

Novel Liquid Argon Time-Projection Chamber Readouts

Liquid argon time-projection chambers (LArTPCs) have become a prominent tool for experiments in particle physics. Recent years have yielded significant advances in the techniques used to capture the signals generated by these cryogenic detectors. This article summarizes these novel developments for detection of ionization electrons and scintillation photons in LArTPCs. New methods to capture ionization signals address the challenges of scaling traditional techniques to the large scales necessary for future experiments. Pixelated readouts improve signal fidelity and expand the applicability of LArTPCs to higher-rate environments. Methods that leverage amplification in argon enable measurements in the keV regime and below. Techniques to enhance collection of argon scintillation photons improve calorimetry and expand the physics program for very large detectors. Future efforts aim to demonstrate systems for the combined detection of both electrons and photons.

43 PARTICLE ACCELERATORS↗

A Perspective on the Impact of Group Delay Dispersion in Future Terahertz Wireless Systems

This article discusses the challenges and opportunities of managing group delay dispersion (GDD), and its relation to the performance standards of future sixth-generation (6G) wireless communication systems utilizing terahertz frequency waves. The unique susceptibilities of 6G systems to GDD are described, along with a quantitative description of the sources of GDD, including multipath, rough surface scattering, intelligent reflecting surfaces, and propagation through the atmosphere. An experimental case-study is presented that confirms previous models quantifying the impact of atmospheric GDD. Several GDD manipulation strategies are presented, illustrating their hindered effectiveness in the 6G context. Conversely, some benefits of leveraging GDD to enhance 6G systems, such as improved security and simplified hardware, are also discussed. Finally, a perspective on using photonic GDD control devices is provided, revealing quantitative benefits that may unburden existing equalization schemes. Here, the article argues that GDD will uniquely and significantly impact some 6G systems, but that its careful consideration along with new mitigation strategies, including photonic devices, will help optimize system performance. The conclusion provides a perspective to guide future research in this area.

Strecker, Karl↗

Characterization of quantum dot-like emitters in programmable arrays of nanowrinkles of 1L-WSe2

When combined with nanostructured substrates, two-dimensional semiconductors can be engineered with strain to tailor light–matter interactions on the nanoscale. Recently, room-temperature nanoscale exciton localization with controllable wrinkling in 1L-WSe2 was achieved using arrays of gold nanocones. Here, the characterization of quantum dot-like states and single-photon emitters in the 1L-WSe2/nanocone system is reported. The nanocones induce a wide range of strains, and as a result, a diverse ensemble of narrowband, potential single-photon emitters is observed. The distribution of emitter energies reveals that most reside in two spectrally isolated bands, leaving a less populated intermediate band that is spectrally isolated from the ensembles. The spectral isolation is advantageous for high-purity quantum light emitters, and anti-bunched emission from one of these states is confirmed up to 25 K. Although the spatial distribution of strain is expected to influence the orientation of the transition dipoles of the emitters, multimodal emission polarization anisotropy and atomic force microscopy reveal that the macroscopic orientation of the wrinkles is not a good predictor of dipole orientation. Finally, the emission is found to change with thermal cycling from 4 to 290 K and back to 4 K, highlighting the need to control factors such as temperature-induced strain to enhance the robustness of this quantum emitter platform. The initial characterization here shows that controlled nanowrinkles of 1L-WSe2 generate quantum light in addition to uncovering potential challenges that need to be addressed for their adoption into quantum photonic technologies.

Physics↗

Advancing X-ray quantum imaging through Monte-Carlo simulations

Imaging with X-rays poses fundamental limits due to radiation damage of the highly energetic photons. This becomes problematic for sensitive biological systems such as subcellular structures. Lowering the radiation dose, without sacrificing the signal-to-noise ratio, would be desirable for any kind of imaging modalities involving X-rays. To achieve this goal, quantum imaging with entangled X-ray photons constitutes a promising route. Production of biphotons have been demonstrated in the X-ray regime by the process of Spontaneous Parametric Down-Conversion (SPDC). However, compared to SPDC in the regime of visible light, the production rate for X-ray biphotons is extremely low. With the introduction of new high average brightness X-ray sources, such as 4th generation synchrotrons and high repetition rate Free-Electron X-ray Lasers (XFEL), quantum imaging may become practical. We introduce a ray tracing approach using Monte-Carlo sampling, specifically designed for quantum imaging with entangled X-ray photons generated by SPDC. By simulation, the superior image quality of quantum over classical imaging methods is demonstrated using realistic experimental conditions available at high repetition rate XFELs. With these simulations, we can efficiently assist the design of future experiments at beam lines, which can substantially accelerate the advancement of X-ray quantum imaging and reduce costs.

Entangled Photons↗

Search for exotic Higgs boson decays H → 𝒜𝒜 with 𝒜 → γγ in events with a semi-merged topology in proton-proton collisions at $\sqrt{s}=13$ TeV

A search for exotic Higgs boson decays H → 𝒜𝒜, with 𝒜 → γγ is presented, using events with a semi-merged topology. One of the hypothetical particles, 𝒜, is assumed to decay promptly into a semi-merged diphoton system reconstructed as a single photon-like object, while the other 𝒜 decays into two resolved photons. The search is performed using proton-proton collision data collected by the CMS experiment at $\sqrt{s}=13$ TeV, corresponding to an integrated luminosity of 138 fb −1 . The data agree with the standard model background expectation. Upper limits are set on the product of the Higgs boson production cross section and the branching fraction, σ(pp → H) ℬ(H → 𝒜𝒜 → 4γ), which range from 0.264 to 0.005 pb at 95% confidence level, for 𝒜 masses in the range 1 < m 𝒜 < 15 GeV. These limits are the most stringent to date in the 1–5 GeV m 𝒜 range.

Beyond Standard Model↗

Differential cross-sections for events with missing transverse momentum and jets measured with the ATLAS detector in 13 TeV proton-proton collisions

Measurements of inclusive, differential cross-sections for the production of events with missing transverse momentum in association with jets in proton-proton collisions at √s = 13 TeV are presented. The measurements are made with the ATLAS detector using an integrated luminosity of 140 fb –1 and include measurements of dijet distributions in a region in which vector-boson fusion processes are enhanced. They are unfolded to correct for detector resolution and efficiency within the fiducial acceptance, and are designed to allow robust comparisons with a wide range of theoretical predictions. A measurement of differential cross sections for the Z → νν process is made. The measurements are generally well-described by Standard Model predictions except for the dijet invariant mass distribution. Auxiliary measurements of the hadronic system recoiling against isolated leptons, and photons, are also made in the same phase space. Ratios between the measured distributions are then derived, to take advantage of cancellations in modelling effects and some of the major systematic uncertainties. These measurements are sensitive to new phenomena, and provide a mechanism to easily set constraints on phenomenological models. To illustrate the robustness of the approach, these ratios are compared with two common Dark Matter models, where the constraints derived from the measurement are comparable to those set by dedicated detector-level searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

All-optical reconfiguration of single silicon-vacancy centers in diamond for non-volatile memories

Strain engineering is vital for tuning the optical and spin properties of solid-state color centers, enhancing spin coherence and compensating emission wavelength shift. Here, we develop an all-optical approach to directly modify the local strain of color centers at the nanoscale by migrating the nearby defect. High-power pulsed optical irradiation triggers defect migration, which subsequently leads to the redistribution of the local crystal lattice of the host material. This redistribution alters the strain experienced by nearby color centers. Using silicon-vacancy centers in diamond, we validate this method and demonstrate a ground state splitting enhancement of up to 1.8 THz. Unlike conventional methods, our approach requires no external fields or nanostructure modifications, enabling non-volatile strain control and optical memory functionality across wide temperature ranges. Its local, permanent nature offers a scalable path for enhancing spin coherence in large-scale quantum systems and has potential applications in photonic machine learning.

Nanoscale devices↗

Reconfigurable plasma-dielectric hybrid photonic crystal as a platform for electromagnetic wave manipulation and computing

The introduction of 3D printing has enabled fabrication of photonic crystal devices with complex crystal structures that would be challenging to construct using other fabrication methods. In this paper, we construct and characterize a photonic crystal consisting of two 4 x 8 x 8 cubic lattices composed of spherical silicon nitride elements straddling a layer of 8 plasma discharge tubes, creating a 3D hybrid plasma photonic crystal device. Integrating under-dense gaseous plasma elements provides a unique coupling dynamic between the dielectric spheres and the cylindrical plasma discharges, creating a monolithic hybrid photonic crystal with solid state and reconfigurable elements. The device has resonant modes that have attenuation peaks that are either switchable, tunable in amplitude, or tunable in frequency with variations in plasma density. The response of these bands seen with varying plasma density is confirmed through simulations when effects due to the heating of the photonic crystal from the gaseous plasma elements are accounted for in the experiments. We discuss how this reconfigurable device may be used and expanded upon for applications in photonic artificial neural networks and optical computing systems.

3D printing↗

Simultaneous measurement of surface velocity and plasma density with interferometric velocimetry

The apparent velocity measured by an interferometric surface velocimeter is a function of both the surface velocity and the time derivative of the refractive index along the measurement path. We employed this dual sensitivity to simultaneously measure km/s surface velocities and 10 18 cm -3 average plasma densities with combined VISAR (velocity interferometer system for any reflector) and PDV (photonic Doppler velocimetry) measurements in experiments performed on the Z Pulsed Power Facility. We detail the governing equations, associated assumptions, and analysis specifics and show that the surface velocity can be extracted without knowledge of the specific plasma density profile.

47 OTHER INSTRUMENTATION↗

Quantitative x-ray scattering of free molecules

Advances in x-ray free electron lasers have made ultrafast scattering a powerful method for investigating molecular reaction kinetics and dynamics. Accurate measurement of the ground-state, static scattering signals of the reacting molecules is pivotal for these pump-probe x-ray scattering experiments as they are the cornerstone for interpreting the observed structural dynamics. Here, this article presents a data calibration procedure, designed for gas-phase x-ray scattering experiments conducted at the Linac Coherent Light Source x-ray Free-Electron Laser at SLAC National Accelerator Laboratory, that makes it possible to derive a quantitative dependence of the scattering signal on the scattering vector. A self-calibration algorithm that optimizes the detector position without reference to a computed pattern is introduced. Angle-of-scattering corrections that account for several small experimental non-idealities are reported. Their implementation leads to near quantitative agreement with theoretical scattering patterns calculated with ab-initio methods as illustrated for two x-ray photon energies and several molecular test systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

Excitation of Bloch Surface Waves in Zero-Admittance Multilayers for High-Sensitivity Sensor Applications

The growing need for classical as well as quantum optical sensing places increasingly stringent requirements upon the desired characteristics of the engendered fields. Specifically, achieving superior field enhancement plays a critical role in applications ranging from chem-bio sensing, Raman and infrared spectroscopies to ion trapping and qubit control in emerging quantum-information science. Due to their low optical losses and ability to exhibit resonant field enhancements, all dielectric multilayers are emerging as an optical material system not only useful to classical photonics and sensing but also of potential to be integrated with quantum materials and quantum sensing. The recently introduced concept of zero-admittance layers [1] within dielectric multilayer materials, enables the creation and control of resonant fields orders of magnitude larger than the exciting field. Here, invoking the zero-admittance concept, we design, fabricate, and characterize an all-dielectric nonabsorbing stack and demonstrate the engendered huge field enhancement. Describing the fields in terms of Bloch surface waves, we connect the surface field to the semiperiodicity in the dielectric domains of the stack. As a specific application of the resonant field, we propose and demonstrate refractive-index sensing for the detection of trace amounts of an analyte. The results include a quantification of the sensitivity of the device with respect to the profile of the exciting field. The experimental results are shown to be in good agreement with theoretical calculations.

47 OTHER INSTRUMENTATION↗

Time-Resolved Line Shapes of Single Quantum Emitters via Machine Learned Photon Correlations

Solid-state single-photon emitters (SPEs) are quantum light sources that combine atomlike optical properties with solid-state integration and fabrication capabilities. SPEs are hindered by spectral diffusion, where the emitter’s surrounding environment induces random energy fluctuations. Timescales of spectral diffusion span nanoseconds to minutes and require probing single emitters to remove ensemble averaging. Photon correlation Fourier spectroscopy (PCFS) can be used to measure time-resolved single emitter line shapes, but is hindered by poor signal-to-noise ratio in the measured correlation functions at early times due to low photon counts. Here, we develop a framework to simulate PCFS correlation functions directly from diffusing spectra that match well with experimental data for single colloidal quantum dots. We use these simulated datasets to train a deep ensemble autoencoder machine learning model that outputs accurate, noiseless, and probabilistic reconstructions of the noisy correlations. Using this model, we obtain reconstructed time-resolved single dot emission line shapes at timescales as low as 10 ns, which are otherwise completely obscured by noise. This enables PCFS to extract optical coherence times on the same timescales as Hong-Ou-Mandel two-photon interference, but with the advantage of providing spectral information in addition to estimates of photon indistinguishability. Further, our machine learning approach is broadly applicable to different photon correlation spectroscopy techniques and SPE systems, offering an enhanced tool for probing single emitter line shapes on previously inaccessible timescales.

74 ATOMIC AND MOLECULAR PHYSICS↗

Characterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging

In this paper, the imaging dose and scan time have been considered as the two major constraints for routine benchtop x-ray fluorescence computed tomography (XFCT) imaging. One way to address this issue is to acquire x-ray fluorescence (XRF) signals in parallel through a 2D array of single-crystal detectors or a pixelated detector along with the cone-beam x-ray source. To identify a detector system suitable for this purpose, a commercially available, fully spectroscopic cadmium telluride (CdTe) pixelated detector, HEXITEC (High-Energy X-ray Imaging Technology), was tested under the experimental conditions optimized for benchtop XFCT imaging of gold nanoparticles (GNPs). Specifically, two different parallel-hole stainless steel collimators were fabricated and coupled with the detector for seamless integration into our existing benchtop cone-beam XFCT system. After the detector deployment, this benchtop XFCT system was used to detect XRF photons from GNP-loaded phantoms. A pixel-merging algorithm was introduced to enhance the sensitivity of XRF photon detection thereby minimizing the scan time. The effect of pixel-level charge sharing correction algorithms was investigated within the context of benchtop XFCT imaging. The detector energy resolution, in terms of the full width at half maximum (FWHM) values at different gold K-shell XRF energies, was also determined. Of the two charge sharing correction algorithms examined, the charge sharing addition gave better sensitivity than the charge sharing discrimination (csd). On the other hand, under the current experimental conditions, the energy resolution of the HEXITEC detector was the best with the csd and estimated to be 1.56 keV FWHM at 66-69 keV photon energy. Overall, despite some degradation of the detector energy resolution (compared with typical single crystal CdTe detectors), the HEXITEC detector enabled parallel data acquisition under the experimental conditions typical of benchtop XFCT imaging and operated well within our benchtop XFCT setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of hydrogen atoms measurement using femtosecond two-photon laser-induced fluorescence

What we believe to be a new calibration method for H-fs-TALIF is proposed, and the ratio of two-photon absorption cross-sections, σ (2) , for atomic hydrogen (H) and krypton (Kr) is determined using the broadband emission of a femtosecond laser system. The estimated ratio of the two-photon absorption cross-sections for H and Kr is σ (2) (Kr)/σ (2) (H) = 0.027 ± 20%, which is nearly twenty times lower than values previously obtained with narrowband nanosecond lasers. This discrepancy highlights the need for independent calibration of TALIF measurements for a specific laser pulsewidth range.

Starikovskiy, Andrey [Princeton Univ., NJ (United ↗

Using Strain in the Vadose Zone During Sinusoidal-Rate Well Tests to Characterize an Aquifer

Well tests with sinusoidal variation in pumping rate are appealing because of the ability to filter competing signals and they also can be set up with no net removal of water, which is an advantage at contaminated sites. Current methods of interpreting sinusoidal-rate well tests analyze the phase lag and amplitude of pressure signals in the aquifer. This approach is restricted by the availability of monitoring wells. An alternative approach could be to measure the stain in the vadose zone instead of pressure in the aquifer. The goal of this research is to evaluate the feasibility of using signals from in-situ sensors in the vadose zone to characterize sinusoidal-rate well tests. Well tests with a variety of periods and amplitudes were performed using a well completed in an unconfined saprolite aquifer with a water table at 9m depth at our test site near Clemson, South Carolina. Vertical strain was measured every meter between 1 to 7 m using a distributed optical fiber sensing technique called coherence length gated microwave photonics interferometry (CMPI). A novel packaging system was designed to couple the optical fiber to the saprolite. The results show that strain measured in the vadose zone during sinusoidal-rate pumping varies periodically with amplitudes from 0.1 to 3 microstrain, depending on the amplitude of the sinusoidal pumping rate. Hydraulic heads at similar radial distances were also periodic with changing amplitudes ranging up to ±0.2 meters. The strain in the vadose zone responds to pressure in the underlying aquifer—the strain is tensile when the pressure is falling, and compressive when the pressure is rising. The phase lag between the pumping rate and the strain was 3 min with a pumping period of 15 minutes, and this gives a hydraulic diffusivity of 0.06 m2/s. This is the same diffusivity obtained by analyzing a constant rate pumping test, and it is slightly larger than the diffusivity (0.044 m2/s) obtained by analyzing the phase lag of the pressure in a nearby monitoring well. Strain measurements in the vadose zone could be made with much less cost and effort than installing a deep monitoring well. These results suggest that strain measurements in the vadose zone could be used to supplement monitoring wells, thereby increasing the resolution, and reducing costs of analyzing well tests.

well test, sinusoidal, periodic pumping, strain↗

Photon Doppler Velocimetry to Spatially Resolve Plasma Density in a Power Flow Gap

The understanding of power flow plasmas is important as we look towards next generation pulsed power (NGPP) as current losses could prohibit the goals of that facility. Therefore, it is important to have accurate diagnostics of the plasma parameters on the current machines, which can be used to help inform and improve simulations. Having these plasma parameters will help validate models and simulations to provide confidence when they are expanded to conditions relevant to NGPP. One important plasma parameter that can be measured is the electron density, which can be measured by photonic Doppler velocimetry (PDV). A PDV system has several key advantages over other interferometers by measuring relatively low densities (> 1 × 10 15 cm -2 ) with both spatial and temporal resolution. Experiments were performed on the Mykonos pulsed power machine, which is a 1 MA sub scale machine in which recent platforms have been developed to explore current densities relevant to the inner magnetically insulated transmission line (MITL) on the Z machine. Experiments were performed on two different platforms, the thin foil platform and the Mykonos parallel plate platform (MP3). In addition, a combination of both single-point and multi-point measurements were used. The single-point measurements proved to be very promising, providing a clear increase in density at about 70 ns into the current rise on thin foil experiments up to about 5 × 10 17 cm -3 before the probe stopped providing signal. While we did also see returns from multi-point measurements on both platforms, the signals were not as easy to interpret due to strong background effects. However, they do show initial promise for this diagnostic to measure density at several points across a 1 mm gap. These measurements provide insights in how to improve the diagnostic so that it can provide useful information on power flow relevant experiments.

47 OTHER INSTRUMENTATION↗