Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quality factor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Cosmic ray LET spectra and doses on board Cosmos-2044 biosatellite

Results of the experiments on board Cosmos-2044 (Biosatellite 9) are presented. Various nuclear track detectors (NTD) (dielectric, AgCl-based, nuclear emulsions) were used to obtain the LET spectra inside and outside the satellite. The spectra from the different NTDs have proved to be in general agreement. The results of LET spectra calculations using two different models are also presented. The resultant LET distributions are used to calculate the absorbed and equivalent doses and the orbit-averaged quality factors (QF) of the cosmic rays (CR). Absorbed dose rates inside (approximately 20 g cm-2 shielding) and outside (1 g cm-2) the spacecraft, omitting electrons, were found to be 4.8 and 8.6 mrad d-1, respectively, while the corresponding equivalent doses were 8.8 and 19.7 mrem d-1. The effects of the flight parameters on the total fluence of, and on the dose from, the CR particles are analyzed. Integral dose distributions of the detected particles are also determined. The LET values which separate absorbed and equivalent doses into 50% intervals are estimated. The CR-39 dielectric NTD is shown to detect 20-30% of the absorbed dose and 60-70% of the equivalent dose in the Cosmos-2044 orbit. The influence of solar activity phase on the magnitude of CR flux is discussed.

Non-NASA Center↗

Linear energy transfer (LET) spectra of cosmic radiation in low Earth orbit

Integral linear energy transfer (LET) spectra of cosmic radiation (CR) particles were measured on five Cosmos series spacecraft in low Earth orbit (LEO). Particular emphasis is placed on results of the Cosmos 1887 biosatellite which carried a set of joint U.S.S.R.-U.S.A. radiation experiments involving passive detectors that included thermoluminescent detectors (TLDs), plastic nuclear track detectors (PNTDs), fission foils, nuclear photo-emulsions, etc. which were located both inside and outside the spacecraft. Measured LET spectra are compared with those theoretically calculated. Results show that there is some dependence of LET spectra on orbital parameters. The results are used to estimate the CR quality factor (QF) for the Cosmos 1887 mission.

NASA Discipline Radiation Health↗

Spiral Chip Implantable Radiator and Printed Loop External Receptor for RF Telemetry in Bio-Sensor Systems

The paper describes the operation of a patented wireless RF telemetry system, consisting of a bio-MEMS implantable sensor and an external hand held unit, operating over the frequency range of few hundreds of MHz. A MEMS capacitive pressure sensor integrated with a miniature inductor/antenna together constitute the implantable sensor. Signal processing circuits collocated with a printed loop antenna together form the hand held unit, capable of inductively powering and also receiving the telemetry signals from the sensor. The paper in addition, demonstrates a technique to enhance the quality factor and inductance of the inductor in the presence of a lower ground plane and also presents the radiation characteristics of the loop antenna.

Simons, Rainee N.↗

Phobos Ephemeris Improvement from Recent Spacecraft Observations

Despite 127 years of observations, there is still room for improvement in the ephemeris of the Martian satellite Phobos. Early in this history, Earth-based astrometric observations of Phobos and Deimos were used to estimate the mass and oblateness of Mars. As more data accumulated, it became clear that a secular acceleration in the longitude of Phobos was occurring, and this was attributed to tidal dissipation within Mars, yielding rough estimates of the tidal quality factor, or Q. At the epoch of the earliest spacecraft observations of Phobos, from Mariner 9 and the Viking Orbiters and Landers, the gravitational field of Mars, and resulting forces on Phobos, were still not particularly well known. Thus observations of natural and artificial satellite motions continued to contribute, each in their own way, to knowledge of the mass distribution within Mars. Improvements in tracking system accuracy, and the placement of satellites, like the 1996 Mars Global Surveyor and 2001 Mars Odyssey, in circular polar orbits has lead to dramatic improvements to knowledge of the Mars gravity field. The direct gravitational influence on Phobos is no longer expected to be a limiting factor in predicting its orbital motion. Despite that progress, a variety of observations of Phobos from recent orbiters and landers suggest that the best satellite ephemeris still has along-track orbit errors which are accumulating at a rate of 1.75 kilometers per year, with Phobos gaining on the predicted positions. These recent observations alone do not span sufficient time to separately resolve the positional error into changes in mean motion and changes in secular acceleration. However, combining them with earlier observations will allow improvements in both the mean motion and its first derivative. This latter parameter is particularly interesting, as it relates to tidal dissipation, and thus uniquely constrains the internal structure of Mars. The current best estimate of the secular acceleration rate of Mars implies a surprisingly low value for the tidal dissipation factor Q = (94 plus or minus 1). For the Earth, most tidal dissipation occurs within the oceans. The terrestrial mantle tidal Q is 280. An issue of interest is then: why, where, and how does Mars dissipate tidal energy so effectively.

Bills, B. G.↗

Discovery of the Neutron Star Spin Frequency in EXO 0748-676

We report the results of a search for burst oscillations during thermonuclear X-ray bursts from the low mass X-ray binary (LMXB) EXO 0748-676. With the proportional counter array (PCA) onboard the Rossi X-ray Timing Explorer (RXTE) we have detected a 45 Hz oscillation in the average power spectrum of 38 thermonuclear X-ray bursts from this source. We computed power spectra with 1 Hz frequency resolution for both the rising and decaying portions of 38 X-ray bursts from the public RXTE archive. We averaged the 1 Hz power spectra and detected a significant signal at 45 Hz in the decaying phases of the bursts. The signal is detected at a significance level of 4 x 10 (exp -8) similar signal was detected in the rising intervals. The oscillation peak is unresolved at 1 Hz frequency resolution, indicating an oscillation quality factor, Q = nu (sub 0)/Delta nu (sub fwhm) greater than 45, and the average signal amplitude is approximately equal to 3% (rms) The detection of 45 Hz burst oscillations from EXO 0748-676 provides compelling evidence that this is the neutron star spin frequency in this system. We use the inferred spin frequency to model the widths of absorption lines from the neutron star surface and show that the widths of the absorption lines from EXO 0748-676 recently reported by Cottam et al. are consistent with a 45 Hz spin frequency as long as the neutron star radius is in the range from about 9.5 - 15 km. With a known spin frequency, precise modelling of the line profiles from EXO 0748-676 holds great promise for constraining the dense matter equation of state.

Villarreal, Adam R.↗

Issues in protection from galactic cosmic rays

Radiation risks to astronauts depend on the microscopic fluctuations of energy absorption events in specific tissues. These fluctuations depend not only on the space environment but also on the modifications of that environment by the shielding provided by structures surrounding the astronauts and the attenuation characteristics of the astronaut's body. The effects of attenuation within the shield and body depends on the tissue biological response to these microscopic fluctuations. In the absence of an accepted method for estimating astronaut risk, we examined the attenuation characteristics using conventional linear energy transfer (LET)-dependent quality factors (as one means of representing relative biological effectiveness, RBE) and a track-structure repair model to fit cell transformation (and inactivation) data in the C3H10 T1/2 mouse cell system obtained for various ion beams. Although the usual aluminum spacecraft shield is effective in reducing dose equivalent with increasing shield thickness, cell transformation rates are increased for thin aluminum shields. Clearly, the exact nature of the biological response to LET and track width is critical to evaluation of biological protection factors provided by a shield design. A significant fraction of biological injury results from the LET region above 100 keV/mu m. Uncertainty in nuclear cross-sections results in a factor of 2-3 in the transmitted LET spectrum beyond depths of 15 g/cm2, but even greater uncertainty is due to the combined effects of uncertainty in biological response and nuclear parameters. Clearly, these uncertainties must be reduced before the shield design can be finalised.

NASA Discipline Number 45-10↗

Application of the GRC Stirling Convertor System Dynamic Model

The GRC Stirling Convertor System Dynamic Model (SDM) has been developed to simulate dynamic performance of power systems incorporating free-piston Stirling convertors. This paper discusses its use in evaluating system dynamics and other systems concerns. Detailed examples are provided showing the use of the model in evaluation of off-nominal operating conditions. The many degrees of freedom in both the mechanical and electrical domains inherent in the Stirling convertor and the nonlinear dynamics make simulation an attractive analysis tool in conjunction with classical analysis. Application of SDM in studying the relationship of the size of the resonant circuit quality factor (commonly referred to as Q) in the various resonant mechanical and electrical sub-systems is discussed.

Regan, Timothy F.↗

Improved Estimate of Phobos Secular Acceleration from MOLA Observations

We report on new observations of the orbital position of Phobos, and use them to obtain a new and improved estimate of the rate of secular acceleration in longitude due to tidal dissipation within Mars. Phobos is the inner-most natural satellite of Mars, and one of the few natural satellites in the solar system with orbital period shorter than the rotation period of its primary. As a result, any departure from a perfect elastic response by Mars in the tides raised on it by Phobos will cause a transfer of angular momentum from the orbit of Phobos to the spin of Mars. Since its discovery in 1877, Phobos has completed over 145,500 orbits, and has one of the best studied orbits in the solar system, with over 6000 earth-based astrometric observations, and over 300 spacecraft observations. As early as 1945, Sharpless noted that there is a secular acceleration in mean longitude, with rate (1.88 + 0.25) 10(exp -3) degrees per square year. In preparation for the 1989 Russian spacecraft mission to Phobos, considerable work was done compiling past observations, and refining the orbital model. All of the published estimates from that era are in good agreement. A typical solution (Jacobson et al., 1989) yields (1.249 + 0.018) 10(exp -3) degrees per square year. The MOLA instrument on MGS is a laser altimeter, and was designed to measure the topography of Mars. However, it has also been used to make observations of the position of Phobos. In 1998, a direct range measurement was made, which indicated that Phobos was slightly ahead of the predicted position. The MOLA detector views the surface of Mars in a narrow field of view, at 1064 nanometer wavelength, and can detect shadows cast by Phobos on the surface of Mars. We have found 15 such serendipitous shadow transit events over the interval from xx to xx, and all of them show Phobos to be ahead of schedule, and getting progressively farther ahead of the predicted position. In contrast, the cross-track positions are quite close to the predicted values. Assuming that the along-track discrepancy is small enough that we can linearize the corrections, we model the mean orbital longitude as a quadratic function of time, and solve for corrections to the constant, linear, and quadratic terms. The time span of the recent observations is insufficient to properly resolve this issue alone, but when the 127 years of prior observations are added, we find a solution which reduces misfit to the new observations considerably, and makes no significant change to the fit to earlier observations. Our estimate for the secular acceleration term is (1.367 + 0.006) degrees per square year. The corresponding rate of energy dissipation is 3.34 MW. From a geophysical perspective, a more interesting parameter than the secular acceleration itself is the tidal lag angle, or tidal quality factor Q, for Mars. Unfortunately, the limiting error source in that determination is remaining uncertainty in the tidal Love numbers at harmonic degrees 2,3, and even 4. Until those parameters are better constrained, improvement in the orbital model of Phobos will not provide corresponding benefits for understanding the interior of Mars.

Bills, Bruce↗

A Superfluid Clock

The performance of clocks is limited by the characteristics of the underlying oscillator. Both the quality factor of the oscillator and the signal-to-noise ratio for the resonator state measurement are important. A superfluid helium Helmholtz resonator operating at approx.100mK temperatures has the potential of maintaining frequency stability of 5x10(exp -15)/t(exp 1/2) on the time scale of a few months. The high dynamic range of lossless SQUID position displacement measurement, and low losses associated with the superfluid flow, combined with high mechanical stability of cryogenic assemblies, contribute to the projected stability. Low overall mass of the assembly allows for multiple stages of vibration isolation.

Penanen, Konstantin↗

Tunability and synthetic lineshapes in high-Q optical whispering gallery modes

We demonstrate novel techniques to manipulate spectral properties of high quality factor (Q>107) whispering-gallery modes (WGM) in optical dielectric microresonators. These include permanent frequency trimming of WGM frequencies by means of UV photosensitivity of germanium doped silica resonators electro-optical tuning of WGM in lithium niobate resonators, and cascading of microresonators for obtaining second-order filtering function. We present theoretical interpretation of experimental results, and application example of techniques for photonic microwave filtering.

optical filters↗

Photorefractivity in WGM resonators

We report on observation of photorefractive effects in whispering gallery mode resonators made of as-grown and magnesium doped lithium niobate and lithium tantalate in the near as well as far infrared. The effects manifested themselves as dynamic modification of the spectra as well as quality factors of the resonators coupled to the laser radiation. We have observed a significant (exceeding 10-4) change of the ordinary index of refraction of all the materials exposed with 780 nm light. Photorefractive effects have also been detected at 1550 nm. Our experiments support the conclusion that the photorefractivity does not have a distinct red boundary. We show that the maximum saturated refractive index change in the infrared is of the same order of magnitude as in the visible light.

optical resonator↗

Optimization of Crew Shielding Requirement in Reactor-Powered Lunar Surface Missions

On the surface of the moon -and not only during heightened solar activities- the radiation environment As such that crew protection will be required for missions lasting in excess of six months. This study focuses on estimating the optimized crew shielding requirement for lunar surface missions with a nuclear option. Simple, transport-simulation based dose-depth relations of the three (galactic, solar, and fission) radiation sources am employed in a 1-dimensional optimization scheme. The scheme is developed to estimate the total required mass of lunar-regolith separating reactor from crew. The scheme was applied to both solar maximum and minimum conditions. It is shown that savings of up to 30% in regolith mass can be realized. It is argued, however, that inherent variation and uncertainty -mainly in lunar regolith attenuation properties in addition to the radiation quality factor- can easily defeat this and similar optimization schemes.

Barghouty, Abdulnasser F.↗

Engineered Carbon Nanotube Materials for High-Q Nanomechanical Resonators

This document represents a presentation offered by the Jet Propulsion Laboratory, with assistance from researchers from Brown University and Northrop Grumman. The presentation took place in Seoul, Korea in July 2003 and attempted to demonstrate the fabrication approach regarding the development of high quality factor (high-Q) mechanical oscillators (in the forms of a tunable nanotube resonator and a nanotube array radio frequency [RF] filter) aimed at signal processing and based on carbon nanotubes. The presentation also addressed parallel efforts to develop both in-plane single nanotube resonators as well as vertical array power devices.

chemical vapor depositions↗

Recent Low-Earth Orbit Radiation Measurements Using Passive Dosimeters during ISS Expeditions 13, 14 and 15

Current passive radiation measurements in low-Earth orbit (LEO) involve using a combination of thermally/optically stimulated luminescence detectors (TLDs/OSLDs) for the low-LET component (LET<10 keV/micron water) of the space radiation field and plastic nuclear track detectors (PNTDs) for the high-LET region (LET>10 keV/micron water), as per National Council on Radiation Protection recommendation (NCRP 132, 2004). This combination of radiation detectors has been successfully implemented at NASA Johnson Space Center for routine crewmember and ISS area monitoring using LiF:Mg,Ti, CaF2:Tm, Al2O3:C and CR-39 material. This paper will present in detail the measurement and data processing techniques employed for passive space radiation measurements by the Space Radiation Analysis Group (SRAG) at JSC. The paper will also summarize the absorbed dose, dose equivalent and quality factor results for the area monitoring during ISS Expeditions 13, 14 and 15.

Gaza, R.↗

Radiation Measured during ISS-Expedition 13 with Different Dosimeters

Radiation in low Earth orbit (LEO) is mainly composed of Galactic Cosmic Rays (GCR), solar energetic particles and particles in SAA (South Atlantic Anomaly). The biological impact of space radiation to astronauts depends strongly on the particles linear energy transfer (LET) and is dominated by high LET radiation. It is important to measure the LET spectrum for the space radiation field and to investigate the influence of radiation on astronauts. At present, the preferred active dosimeters sensitive to all LET are the tissue equivalent proportional counter (TEPC) and silicon detectors in various configurations; the preferred passive dosimeters are thermoluminescence dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) sensitive to low LET as well as CR-39 plastic nuclear track detectors (PNTDs) sensitive to high LET. The TEPC, CR-39 PNTDs, TLDs and OSLDs were used to investigate the radiation exposure for the ISS mission Expedition 13 (ISS-12S) in LEO. LET spectra and radiation quantities (fluence, absorbed dose, dose equivalent and quality factor) were measured for the space mission with different dosimeters. This paper introduces the operational principles for the dosimeters, describes the method to combine the results measured by TLDs/OSLDs and CR-39 PNTDs, and presents the LET spectra and the radiation quantities measured. Keywords: space radiation; cosmic rays; active and passive dosimeters; LET spectra

Zhou, D.↗

Optimization of Crew Shielding Requirement in Reactor-Powered Lunar Surface Missions

On the surface of the moon and not only during heightened solar activities the radiation environment is such that crew protection will be required for missions lasting in excess of six months. This study focuses on estimating the optimized crew shielding requirement for lunar surface missions with a nuclear option. Simple, transport-simulation based dose-depth relations of the three radiation sources (galactic, solar, and fission) are employed in a one-dimensional optimization scheme. The scheme is developed to estimate the total required mass of lunar regolith separating reactor from crew. The scheme was applied to both solar maximum and minimum conditions. It is shown that savings of up to 30% in regolith mass can be realized. It is argued, however, that inherent variation and uncertainty mainly in lunar regolith attenuation properties in addition to the radiation quality factor can easily defeat this and similar optimization schemes.

Barghouty, A. F.↗