Search NASA⌕ Search

SEARCH · Search NASA

Results for “Quantitative analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Database for LDV Signal Processor Performance Analysis

A comparative and quantitative analysis of various laser velocimeter signal processors is difficult because standards for characterizing signal bursts have not been established. This leaves the researcher to select a signal processor based only on manufacturers' claims without the benefit of direct comparison. The present paper proposes the use of a database of digitized signal bursts obtained from a laser velocimeter under various configurations as a method for directly comparing signal processors.

Baker, Glenn D.↗

Single Quadrupole Multiple Fragment Ion Monitoring Quantitative Mass Spectrometry

Single quadrupole mass spectrometry (MS) with enhanced in-source multiple fragment ion monitoring was designed to perform high sensitivity quantitative mass analyses. Enhanced in-source fragmentation amplifies fragmentation from traditional soft electrospray ionization producing fragment ions that have been found to be identical to those generated in tandem MS. We have combined enhanced in-source fragmentation data with criteria established by the European Union Commission Directive 2002/657/EC for electron ionization single quadrupole quantitative analysis to perform quantitative analyses. These experiments were performed on multiple types of complex samples that included a mixture of 50 standards, as well as cell and plasma extracts. The dynamic range for these quantitative analyses was comparable to triple quadrupole multiple reaction monitoring (MRM) analyses at up to 5 orders of magnitude with the cell and plasma extracts showing similar matrix effects across both platforms. Amino acid and fatty acid measurements performed from certified NIST 1950 plasma with isotopically labeled standards demonstrated accuracy in the range of 91–110% for the amino acids, 76–129% for the fatty acids, and good precision (coefficient of variation <10%). To enhance specificity, a newly developed correlated ion monitoring algorithm was designed to facilitate these analyses. This algorithm autonomously processes, aligns, filters, and compiles multiple ions within one chromatogram enabling both precursor and in-source fragment ions to be correlated within a single chromatogram, also enabling the detection of coeluting species based on precursor and fragment ion ratios. Single quadrupole instrumentation can provide MRM level quantitative performance by monitoring/correlating precursor and fragment ions facilitating high sensitivity analysis on existing single quadrupole instrumentation that are generally inexpensive, easy to operate, and technically less complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative Particle Analysis of Neptunium-237 Oxides: Optimization of MAMA Analysis for Modified Direct Denitration Products

The production of plutonium-238 through irradiation of neptunium-237 ( 237 Np) target materials for the use in radioisotope thermoelectric generators is paramount for continued deep space exploration. This work employs scanning electron microscopy to analyze 237 Np materials coupled with a well-developed image analysis framework (Morphological Analysis for Material Attribution, or MAMA) to determine the degree of micron-scale homogeneity in the materials. This work demonstrated how the quantification of particle characteristics can validate production materials and affirm the qualitative similarities observed in micrographs. The 237 Np oxide particle analysis determined that the materials from five production runs were quantitatively homogenous (significant at α = 0.05) in particle area, circularity, equivalent circular diameter, and ellipse aspect ratio, with two of the sampling dates having statistically significant different means for one of the four characteristics. Furthermore, these metrics not only confirm general homogeneity of the material but also expand the application of MAMA workflows to 237 Np materials, demonstrating the utility of MAMA analysis for a wider breadth of nuclear materials than previously reported. In the open literature, this study is the first time that these microanalytical techniques were applied to 237 Np materials to this degree.

MAMA↗

A Quantitative Failure Analysis on Capacity Fade in Rechargeable Lithium Metal Cells

Rechargeable lithium battery (RLB) technology is transforming portable devices, vehicle electrification, and grid modernization. To make RLB durable, reliable and safe, conducting failure mode and effect analysis (FMEA) to identify failure mechanism under the operating conditions is very desirable. However, this ability is often overlooked or even lacking. The failure analysis (FA) is often conducted by laboratory testing and postmortem analysis, and the knowledge typically empirical. Here we present a quantitative approach for FMEA that can reveal how failure modes and effects reduce the capacity of a RLB. This approach is based on the state of the battery for FMEA, contrary to the conventional approach based on operating or testing conditions. The key aspect of this FMEA method is to convert the experimental results to a state-of-charge (SOC)-based analytic methodology. Such a conversion can separate the thermodynamic and kinetic attributes of capacity fade based on compositional correspondence in the electrode, so the loss and the decreased utilization of the active materials can be determined respectively.

25 ENERGY STORAGE↗

Multivariate statistics applications in phase analysis of STEM-EDS spectrum images

Spectrum imaging (SI) methods are displacing traditional spot analyses as the predominant paradigm for spectroscopic analysis with electron beam instrumentation. The multivariate nature of SI provides clear advantages for qualitative analysis of multiphase specimens relative to traditional gray-scale images acquired with non-spectroscopic signals, where different phases with similar average atomic number may exhibit the same intensity. However, with the improvement in qualitative analysis with the SI paradigm has come a decline in the quantitative analysis of the phases thus identified, since the spectra from individual pixels typically have insufficient counting statistics for proper quantification. The present paper outlines a methodology for quantitative analysis within the spectral imaging paradigm, which is illustrated through X-ray energy-dispersive spectroscopy (EDS) of a multiphase (Pb,La)(Zr,Ti)O{sub 3} ceramic in scanning transmission electron microscopy (STEM). Statistical analysis of STEM-EDS SI is shown to identify the number of distinct phases in the analyzed specimen and to provide better segmentation than the STEM high-angle annular dark-field (HAADF) signal. Representative spectra for the identified phases are extracted from the segmented images with and without exclusion of pixels that exhibit spectral contributions from multiple phases, and subsequently quantified using Cliff-Lorimer sensitivity factors. The phase compositions extracted with the method while excluding pixels from multiple phases are found to be in good agreement with those extracted from user-selected regions of interest, while providing improved confidence intervals. Without exclusion of multiphase pixels, the extracted composition is found to be in poor statistical agreement with the other results because of systematic errors arising from the cross-phase spectral contamination. The proposed method allows quantification to be performed in the presence of discontinuous phase distributions and overlapping phases, challenges that are typical of many nanoscale analyses performed by STEM-EDS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Use of local noise power spectrum and wavelet analysis in quantitative image quality assurance for EPIDs

Purpose: To investigate the use of local noise power spectrum (NPS) to characterize image noise and wavelet analysis to isolate defective pixels and inter-subpanel flat-fielding artifacts for quantitative quality assurance (QA) of electronic portal imaging devices (EPIDs). Methods: A total of 93 image sets including custom-made bar-pattern images and open exposure images were collected from four iViewGT a-Si EPID systems over three years. Global quantitative metrics such as modulation transform function (MTF), NPS, and detective quantum efficiency (DQE) were computed for each image set. Local NPS was also calculated for individual subpanels by sampling region of interests within each subpanel of the EPID. The 1D NPS, obtained by radially averaging the 2D NPS, was fitted to a power-law function. The r-square value of the linear regression analysis was used as a singular metric to characterize the noise properties of individual subpanels of the EPID. The sensitivity of the local NPS was first compared with the global quantitative metrics using historical image sets. It was then compared with two commonly used commercial QA systems with images collected after applying two different EPID calibration methods (single-level gain and multilevel gain). To detect isolated defective pixels and inter-subpanel flat-fielding artifacts, Haar wavelet transform was applied on the images. Results: Global quantitative metrics including MTF, NPS, and DQE showed little change over the period of data collection. On the contrary, a strong correlation between the local NPS (r-square values) and the variation of the EPID noise condition was observed. The local NPS analysis indicated image quality improvement with the r-square values increased from 0.80 ± 0.03 (before calibration) to 0.85 ± 0.03 (after single-level gain calibration) and to 0.96 ± 0.03 (after multilevel gain calibration), while the commercial QA systems failed to distinguish the image quality improvement between the two calibration methods. With wavelet analysis, defective pixels and inter-subpanel flat-fielding artifacts were clearly identified as spikes after thresholding the inversely transformed images. Conclusions: The proposed local NPS (r-square values) showed superior sensitivity to the noise level variations of individual subpanels compared with global quantitative metrics such as MTF, NPS, and DQE. Wavelet analysis was effective in detecting isolated defective pixels and inter-subpanel flat-fielding artifacts. The proposed methods are promising for the early detection of imaging artifacts of EPIDs.

60 APPLIED LIFE SCIENCES↗

Quality Assessments of Long-Term Quantitative Proteomic Analysis of Breast Cancer Xenograft Tissues

The identification of protein biomarkers requires large-scale analysis of human specimens to achieve statistical significance. In this study, we evaluated the long-term reproducibility of an iTRAQ (isobaric tags for relative and absolute quantification) based quantitative proteomics strategy using one channel for universal normalization across all samples. A total of 307 liquid chromatography tandem mass spectrometric (LC-MS/MS) analyses were completed, generating 107 one-dimensional (1D) LC-MS/MS datasets and 8 offline two-dimensional (2D) LC-MS/MS datasets (25 fractions for each set) for human-in-mouse breast cancer xenograft tissues representative of basal and luminal subtypes. Such large-scale studies require the implementation of robust metrics to assess the contributions of technical and biological variability in the qualitative and quantitative data. Accordingly, we developed a quantification confidence score based on the quality of each peptide-spectrum match (PSM) to remove quantification outliers from each analysis. After combining confidence score filtering and statistical analysis, reproducible protein identification and quantitative results were achieved from LC-MS/MS datasets collected over a 16 month period.

Environmental Molecular Sciences Laboratory↗

Combinational pixel-by-pixel and object-level classifying, segmenting, and agglomerating in performing quantitative image analysis that distinguishes between healthy non-cancerous and cancerous cell nuclei and delineates nuclear, cytoplasm, and stromal material objects from stained biological tissue materials

Quantitative object and spatial arrangement-level analysis of tissue are detailed using expert (pathologist) input to guide the classification process. A two-step method is disclosed for imaging tissue, by classifying one or more biological materials, e.g. nuclei, cytoplasm, and stroma, in the tissue into one or more identified classes on a pixel-by-pixel basis, and segmenting the identified classes to agglomerate one or more sets of identified pixels into segmented regions. Typically, the one or more biological materials comprises nuclear material, cytoplasm material, and stromal material. The method further allows a user to markup the image subsequent to the classification to re-classify said materials. The markup is performed via a graphic user interface to edit designated regions in the image.

59 BASIC BIOLOGICAL SCIENCES↗

On the development of the quantitative texture analysis and its application in solving problems of the Earth sciences

A history of texture analysis (TA) evolution is shown, beginning from the first experimental and theoretical attempts to find and characterize preferred orientations of crystal lattices of grains in real polycrystalline samples. Stages of formation of TA theoretical apparatus, its basic elements, and also application of its capabilities for quantitatively describing anisotropic properties of textured samples are discussed. Attention is also paid to the limitations and difficulties associated with the analysis. The application of the quantitative TA apparatus is demonstrated by example describing elastic properties of textured materials up to multiphase samples containing pores and cracks. A wide scope of TA includes the analysis based on neutron scattering which has been effectively developed at the Frank Laboratory of Neutron Physics. A practical opportunity to determine the bulk crystallographic textures of single-phase and multiphase materials is offered by the use of modern neutron diffractometers, including the SKAT diffractometer at the IBR-2 pulsed reactor. This is especially important for studying samples of natural rocks. The examples given show how the neutron scattering data for the quantitative TA are used in combination with other physical and petrological methods for solving fundamental problems of geology and geophysics based on the analysis of a structure and properties of the Earth’s lithosphere matter. The review includes a detailed list of references of original works concerning the TA elaboration, overview publications and monographs, and also information on the most popular TA-related software.

36 MATERIALS SCIENCE↗

Quantitative carbide analysis using the Rietveld method for 2.25Cr-1Mo-0.25V steel

It is usually difficult to quantitatively determine the mass fraction of each type of precipitates in steels using transmission electron microscopy and traditional X-ray powder diffraction analysis methods. In this paper the Rietveld full-pattern fitting algorithm was employed to calculate the relative mass fractions of the precipitates in 2.25Cr-1Mo-0.25V steel. The results suggest that the fractions of MC, M{sub 7}C{sub 3} and M{sub 23}C{sub 6} carbides were evaluated precisely and relatively quickly. In addition, it was found that the fine MC phase dissolved into the matrix with prolonged tempering.

36 MATERIALS SCIENCE↗

Calibration Issues and Operating System Requirements for Electron-Probe Microanalysis

Instrument purchase requirements and dialogue with manufacturers have established hardware parameters for alignment, stability, and reproducibility, which have helped improve the precision and accuracy of electron microprobe analysis (EPMA). The development of correction algorithms and the accurate solution to quantitative analysis problems requires the minimization of systematic errors and relies on internally consistent data sets. Improved hardware and computer systems have resulted in better automation of vacuum systems, stage and wavelength-dispersive spectrometer (WDS) mechanisms, and x-ray detector systems which have improved instrument stability and precision. Improved software now allows extended automated runs involving diverse setups and better integrates digital imaging and quantitative analysis. However, instrumental performance is not regularly maintained, as WDS are aligned and calibrated during installation but few laboratories appear to check and maintain this calibration. In particular, detector deadtime (DT) data is typically assumed rather than measured, due primarily to the difficulty and inconvenience of the measurement process. This is a source of fundamental systematic error in many microprobe laboratories and is unknown to the analyst, as the magnitude of DT correction is not listed in output by microprobe operating systems. The analyst must remain vigilant to deviations in instrumental alignment and calibration, and microprobe system software must conveniently verify the necessary parameters. Microanalysis of mission critical materials requires an ongoing demonstration of instrumental calibration. Possible approaches to improvements in instrument calibration, quality control, and accuracy will be discussed. Development of a set of core requirements based on discussions with users, researchers, and manufacturers can yield documents that improve and unify the methods by which instruments can be calibrated. These results can be used to continue improvements of EPMA.

Carpenter, P.↗

Water penetration through cracks in self-healing cementitious materials with superabsorbent polymers studied by neutron radiography

SuperAbsorbent Polymers (SAPs) are a promising admixture to obtain self-sealing and self-healing cementitious materials. They are able to physically block water penetration through cracks due to their swelling ability. This is very useful in a cementitious material which is prone to cracking leading to a reduced durability. The effectiveness of counteracting water penetration is of concern. Neutron radiography was performed in order to investigate the influence of SAPs on the water permeability through healed cracks with respect to a reference material without SAPs. The gravimetrically measured capillary absorption corresponded with the obtained results after image analysis and a quantitative analysis could be made. SAPs enhance the water impermeability and are able to seal and heal a crack effectively up to 100 μm. The healing was a main factor to impede water movement through cracks. This will lead to less water ingress in building infrastructures and a possible longer service life.

36 MATERIALS SCIENCE↗

Analysis and prediction of reaction kinetics using the degree of rate control

“Degree of rate control” (DRC) analysis provides a quantitative approach for analysing the kinetics of multi-step reaction mechanisms that has been widely applied to both heterogeneous and homogeneous catalysis research, as well as electrocatalysis. The DRC of any given transition state or intermediate is defined as a partial derivative such that it approximately equals the fractional increase in net rate to the product of interest per differential decrease in its standard-state free energy for that species (÷RT), holding constant the standard-state free energies of all other transition states and intermediates. Even very complex mechanisms usually have only a few species with non-zero DRCs and are thus the species whose interactions with the catalyst most strongly affect the net rate. These key DRC values thus offer a simple and intuitive route to optimize catalyst materials, especially with the assistance of computational methods like density functional theory (DFT). These high-DRC species are also the species whose energetics must be most accurately measured or calculated to achieve an accurate kinetic model for any reaction mechanism. In simple cases with a single “rate-determining step”, the DRC for its transition state (TS) is + 1. Catalyst-bound intermediates, on the other hand, often have negative DRCs equal to a small integer times their fractional occupancy of catalyst sites. The apparent activation energy equals a weighted average of the standard-state enthalpies (relative to reactants) of all the species (intermediates, transition states and products) in the reaction mechanism, each weighted by its DRC (+RT). It has been shown that the apparent transfer coefficient in electrocatalysis, an inverted form of the Tafel slope, is a weighted average of the number of electrons transferred to generate each intermediate or product species in the mechanism, weighted again by the DRC. Quantitative analysis of kinetic isotope effects (KIEs, or the ratio of net rates for different reactant isotopes) in complex mechanisms has shown that the logarithm of the KIE equals the weighted average over all species in the mechanism of the difference between the two isotopes in their standard-state free energies (÷RT), again weighted by the DRC. The reaction orders with respect to fluid-phase concentrations of reactants, products and intermediates have also been proven to be directly related to DRCs. Thus, there are numerous experimental observables which equate to short linear combinations of DRCs, so that combinations of experimental measurements might provide access to DRC values. Since its invention for transition states in 1994 and its generalization to include intermediates in 2009, the DRC has thus far mainly been calculated for microkinetic models based either entirely on DFT or on DFT with the key energies (i.e., those for high-DRC species) being fine-tuned to match experiments. The relationships summarized in this work provide new opportunities for using experiments earlier in the development and optimization of microkinetic models that require input from computational catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid, Untargeted Chemical Profiling of Single Cells in Their Native Environment

We report a method that enables untargeted, high throughput, and quantitative mass spectrometric analysis of single cells from cell suspension without needing additional sample preparation procedures (e.g., molecular tagging) through the combination of single-cell printer technology and liquid vortex capture–mass spectrometry (SCP-LVC-MS). The operating principle behind the SCP-LVC-MS technology is single cell isolation via small droplet piezoelectric ejection followed by capture of the droplet into an LVC-MS sampling probe. Once exposed to an appropriate solvent, the cell is lysed, extracted, and analyzed by MS. The SCP-LVC-MS approach was validated by measuring the lipid composition of microalgae, Chlamydomonas reinhardtii (ChRe) and Euglena gracilis (EuGr), and HeLa cells in their native growth media. Numerous diacylglyceryltrimethylhomo-Ser (DGTS), phosphatidylcholine (PC), monogalactosyldiacylglycerol (MGDG), and digalactosyldiacylglycerol (DGDG) lipids were observed in single cells. Continuous solvent flow ensures that cells are analyzed rapidly, and no signal carryover between cells is observed. ChRe and EuGr microalgae mixed together in the same solution were differentiated cell-by-cell in real-time based on differences between levels of diacylglyceryltrimethylhomo-Ser (DGTS) and phosphatidylcholine (PC) lipids measured in each cell. Several DGTS lipids present in ChRe were quantified with single-cell resolution by normalizing to a DGTS(32:0) internal standard added to the LVC probe solvent during analysis. Quantitative peak areas were validated by comparing to bulk lipid extracts. Furthermore, peak area distributions comprised of hundreds of cells were compared for ChRe after 5 days of nitrogen-limited and normal growth conditions, which show clear differences and the ability to resolve cellular population differences with single-cell resolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of Crystal Lattice Deformation by Ion Channeling

A model of dislocations has been developed for the use in Monte Carlo simulations of ion channeling spectra obtained for defected crystals. High resolution transmission electron microscopy micrographs show that the dominant type of defects in the majority of ion irradiated crystals are dislocations. The RBS/channeling spectrum is then composed of two components: one is due to direct scattering on randomly displaced atoms and the second one is related to beam defocussing on dislocations, which produce predominantly crystal lattice distortions, i.e. bent channels. In order to provide a correct analysis of backscattering spectra for the crystals containing dislocations we have modified the existing Monte Carlo simulation code "McChasy". A new version of the code has been developed by implementing dislocations on the basis of the Peierls-Nabarro model. Parameters of the model have been determined from the high resolution transmission electron microscopy data. The newly developed method has been used to study the Ar-ion bombarded SrTiO3 samples. The best fit to the Rutherford backscattering/channeling spectra has been obtained by optimizing the linear combination of two kinds of defects: displaced atoms and bent channels. The great virtue of the Monte Carlo simulation is that unlike a traditional dechanneling analysis it allows quantitative analysis of crystals containing a mixture of different types of defects.

Environmental Molecular Sciences Laboratory↗

UT-GOM2-1 Hydrate Pressure Coring Expedition: Chapter 3. Hole GC 955 H002

This report describes the operations, sample collection and handling, initial analyses, and preliminary interpretations developed by the UT-GOM2-1 Science Party for Hole GC 955 H002 (H002). This chapter describes the results of H002 pressure coring, physical property analysis, quantitative degassing, lithostratigraphic analysis, geochemical analysis, and wireline logging. All methods are described in Chapter 2 Expedition Methods.

03 NATURAL GAS↗

UT-GOM2-1: Chapter 4. Hole GC 955 H005

This report describes the operations, sample collection and handling, initial analyses, and preliminary interpretations developed by the UT-GOM2-1 Science Party for Hole GC 955 H005 (H005). This chapter describes H005 pressure coring, physical property analysis, quantitative degassing, lithostratigraphic analysis, geochemical analysis, and wireline logging. All methods are described in Chapter 2 Expedition Methods

03 NATURAL GAS↗

A General Materials Data Science Framework for Quantitative 2D Analysis of Particle Growth from Image Sequences

Abstract Phase transformations are a challenging problem in materials science, which lead to changes in properties and may impact performance of material systems in various applications. We introduce a general framework for the analysis of particle growth kinetics by utilizing concepts from machine learning and graph theory. As a model system, we use image sequences of atomic force microscopy showing the crystallization of an amorphous fluoroelastomer film. To identify crystalline particles in an amorphous matrix and track the temporal evolution of the particle dispersion, we have developed quantitative methods of 2D analysis. 700 image sequences were analyzed using a neural network architecture, achieving 0.97 pixel-wise classification accuracy as a measure of the correctly classified pixels. The growth kinetics of isolated and impinged particles were tracked throughout time using these image sequences. The relationship between image sequences and spatiotemporal graph representations was explored to identify the proximity of crystallites from each other. The framework enables the analysis of all image sequences without the requirement of sampling for specific particles or timesteps for various materials systems.

36 MATERIALS SCIENCE↗