Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Radiation resistance of oxide dispersion strengthened alloys: Perspectives from in situ observations and rate theory calculations

Here, in situ ion irradiation and rate theory calculations were employed to directly compare the radiation resistance of an oxide dispersion strengthened alloy with that of a conventional ferritic/martensitic alloy. Compared to the rapid buildup of dislocation loops, loop growth, and formation of network dislocations in the conventional ferritic/martensitic alloy, the superior radiation resistance of the oxide dispersion strengthened alloy is manifested by its stable dislocation structure under the same irradiation conditions. Thus, the results are consistent with rate theory calculations, which show that high-density nanoparticles can significantly reduce freely migrating defects and suppress the buildup of clustered defects.

36 MATERIALS SCIENCE↗

Superimposed coherent terahertz wave radiation from mono-energetically bunched multi-beam

Intense coherent radiation is obtained from multiple electron beams monochromatically bunched over the wide higher-order-mode (HOM) spectral band in the THz regime. The overmoded waveguide corrugated by dielectric-implanted staggered gratings superimposes evanescent waves emitted from the low energy electron beams. The dispersion and transmission simulations of the three-beam slow wave structure show that the first two fundamental modes ($TE_{10}$ and $TE_{20}$) are considerably suppressed ($\sim-50$ dB) below the multi-beam resonating mode ($TE_{30}$) at the THz regime (0.8–1.24 THz). The theoretical calculations and particle-in-cell simulations show that with significantly higher interaction impedance and power growth rate radiation of the $TE_{30}$ mode is $\sim$23 dBm and $\sim$50 dBm stronger than the $TE_{10}$ and $TE_{20}$ modes around 1 THz, respectively. As a result, this highly selective HOM multi-beam interaction has potential applications for power THz sources and high intensity accelerators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

R and D toward a compact high-brilliance X-ray source based on channeling radiation

X-rays have been valuable to a large number of fields including Science, Medicine, and Security. Yet, the availability of a compact high-spectral brilliance X-ray sources is limited. A technique to produce X-rays with spectral brilliance B{approx} 10{sup 12} photons.(mm-mrd){sup -2}. (0.1% BW){sup -1}.s{sup -1} is discussed. The method is based on the generation and acceleration of a low-emittance field-emitted electron bunches. The bunches are then focused on a diamond crystal thereby producing channeling radiation. In this paper, after presenting the overarching concept, we discuss the generation, acceleration and transport of the low-emittance bunches with parameters consistent with the production of high-brilliance X-rays through channeling radiation. We especially consider the example of the Advanced Superconducting Test Accelerator (ASTA) currently in construction at Fermilab where a proof-of-principle experiment is in preparation.

43 PARTICLE ACCELERATORS↗

Gamma response study of radiation sensitive MOSFETs for their use as gamma radiation sensor

Continuous monitoring of gamma dose is important in various fields like radiation therapy, space-related research, nuclear energy programs and high energy physics experiment facilities. The present work is focused on utilization of radiation-sensitive Metal-Oxide-Semiconductor Field Effect Transistors (MOSFETs) to monitor gamma radiation doses. Static characterization of these detectors was performed to check their expected current-voltage relationship. Threshold voltage and transconductance per unit gate to source voltage (K factor) were calculated from the experimental data. The detector was exposed to gamma radiation in both, with and without gate bias voltage conditions, and change in threshold voltage was monitored at different gamma doses. The experimental data was fitted to obtain equation for dependence of threshold voltage on gamma dose. More than ten times increase in sensitivity was observed in biased condition (+3 V) compared to the unbiased case.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Critical issues in radiation protection knowledge management for preserving radiation protection research and development capabilities

As a hub of domestic radiation protection capabilities, Oak Ridge National Laboratory’s Center for Radiation Protection Knowledge has a mandate to develop and actuate a formal knowledge management (KM) effort. This KM approach exceeds recruitment and training efforts but focuses on formalized strategies for knowledge transfer from outgoing subject matter experts in radiation protection to incoming generations. It is envisioned that such an effort will provide one avenue for preserving domestic capabilities to support stakeholder needs in the federal government and the nuclear industry while continuing to lead and innovate in research and development on a global scale. Furthermore, in the absence of broader coordination within the United States, preservation of radiation protection knowledge continues to be in jeopardy in the absence of a dedicated KM effort.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-C-207A-07: Cumulative 18F-FDG Uptake Histogram Relative to Radiation Dose Volume Histogram of Lung After IMRT Or PSPT and Their Association with Radiation Pneumonitis

Purpose: To determine whether the difference in cumulative 18F-FDG uptake histogram of lung treated with either IMRT or PSPT is associated with radiation pneumonitis (RP) in patients with inoperable stage II and III NSCLC. Methods: We analyzed 24 patients from a prospective randomized trial to compare IMRT (n=12) with vs. PSPT (n=12) for inoperable NSCLC. All patients underwent PET-CT imaging between 35 and 88 days post-therapy. Post-treatment PET-CT was aligned with planning 4D CT to establish a voxel-to-voxel correspondence between post-treatment PET and planning dose images. 18F-FDG uptake as a function of radiation dose to normal lung was obtained for each patient. Distribution of the standard uptake value (SUV) was analyzed using a volume histogram method. The image quantitative characteristics and DVH measures were correlated with clinical symptoms of pneumonitis. Results: Patients with RP were present in both groups: 5 in the IMRT and 6 in the PSPT. The analysis of cumulative SUV histograms showed significantly higher relative volumes of the normal lung having higher SUV uptake in the PSPT patients for both symptomatic and asymptomatic cases (VSUV=2: 10% for IMRT vs 16% for proton RT and VSUV=1: 10% for IMRT vs 23% for proton RT). In addition, the SUV histograms for symptomatic cases in PSPT patients exhibited a significantly longer tail at the highest SUV. The absolute volume of the lung receiving the dose >70 Gy was larger in the PSPT patients. Conclusion: 18F-FDG uptake – radiation dose response correlates with RP in both groups of patients by means of the linear regression slope. SUV is higher for the PSPT patients for both symptomatic and asymptomatic cases. Higher uptake after PSPT patients is explained by larger volumes of the lung receiving high radiation dose.

60 APPLIED LIFE SCIENCES↗

SU-F-T-106: A Dosimetric Study of Intensity Modulated Radiation Therapy to Decrease Radiation Dose to the Thoracic Vertebral Bodies in Patients Receiving Concurrent Chemoradiation for Lung Cancer

Purpose: Recent clinical studies have shown a correlation between radiation dose to the thoracic vertebral bodies (TVB) and the development of hematologic toxicity (HT) in patients receiving chemoradiation (CRT) for lung cancer (LuCa). The feasibility of a bone-marrow sparing (BMS) approach in this group of patients is unknown. We hypothesized that radiation dose to the TVB can be reduced with an intensity modulated radiation therapy(IMRT)/volumetric modulated arc radiotherapy(VMAT) without affecting plan quality. Methods: We identified LuCa cases treated with curative intent CRT using IMRT/VMAT from 4/2009 to 2/2015. The TVBs from T1–T10 were retrospectively contoured. No constraints were placed on the TVB structure initially. A subset were re-planned with BMS-IMRT/VMAT with an objective or reducing the mean TVB dose to <23 Gy. The following data were collected on the initial and BMS plans: mean dose to planning target volume (PTV), lungs-PTV, esophagus, heart; lung V20; cord max dose. Pairwise comparisons were performed using the signed rank test. Results: 94 cases received CRT with IMRT/VMAT. We selected 11 cases (7 IMRT, 4 VMAT) with a range of initial mean TVB doses (median 35.7 Gy, range 18.9–41.4 Gy). Median prescription dose was 60 Gy. BMS-IMRT/VMAT significantly reduced the mean TVB dose by a median of 10.2 Gy (range, 1.0–16.7 Gy, p=0.001) and reduced the cord max dose by 2.9 Gy (p=0.014). BMS-IMRT/VMAT had no impact on lung mean (median +17 cGy, p=0.700), lung V20 (median +0.5%, p=0.898), esophagus mean (median +13 cGy, p=1.000) or heart mean (median +16 cGy, p=0.365). PTV-mean dose was not affected by BMS-IMRT/VMAT (median +13 cGy, p=0.653). Conclusion: BMS-IMRT/VMAT was able to significantly reduce radiation dose to the TVB without compromising plan quality. Prospective evaluation of BMS-IMRT/VMAT in patients receiving CRT for LuCa is warranted to determine if this approach results in clinically significant reductions in HT.

60 APPLIED LIFE SCIENCES↗

Using Jupiter's Synchrotron Radiation as a Probe into Jupiter's Inner Radiation Belts

The Jovian decimetric emission is caused by the combined emission of synchrotron radiation originating from the relativistic electrons trapped in Jupiter's 'Van Allen radiation belts' and thermal emission from the planet's atmosphere. Synchrotron radiation characteristics and variations (which provides insight into the physical properties of Jupiter's inner radiation belts) will be amplified and discussed.

jupiter synchrotron radiation jovian inner radiati↗

The Radiation Biology Ontology: A New Tool Supporting FAIR Principles Across Radiation Biology Facilitating Data Discovery and Integration

Development of the Radiation Biology Ontology (RBO) was motivated by the need for a comprehensive, well-structured ontology for encoding radiation biology metadata. The primary use-cases were archiving data in the STORE database (https://www.storedb.org/), the repository for the RadoNorm Project, and in GeneLab (https://genelab.nasa.gov), NASA’s ‘omics database. The scope of radiobiology research ranges from physics to radiation oncology to socio-legal studies; no existing ontology has the necessary breadth or depth. In addition, a formal ontology has the advantage of being usable for machine learning and, importantly, for tasks like data integration, knowledge extraction from the scientific literature and for query extension and data classification. Standardisation of metadata is one of the primary objectives of the FAIR principles for open data; RBO is an important landmark for FAIR radiation biology data.

ontology↗

Space-Shielding Radiation Dosage Code Evaluation - Phase 1: SHIELDOSE-2 Radiation-Assessment Code

Radiation-transport codes or radiation-analysis tools are used in the spacecraft-design community to define and assess the local radiation levels. Among various radiation-transport/analysis tools available, SHIELDOSE-2 is commonly used in the early spacecraft-design phases because it has been established that it provides reasonably reliable results with relatively rapid computation time. The NASA Engineering and Safety Center initiated a two-phased study: (1) to better understand and document the SHIELDOSE-2 code capabilities and limitations, and (2) to recommend alternative tools to use for cases where SHIELDOSE-2 is not applicable. This report provides a summary of the Phase 1 study.

SHIELDOSE-2↗

Space-Shielding Radiation Dosage Code Evaluation Phase 2: SHIELDOSE-2 Radiation-Assessment Code

Radiation-transport codes or radiation-analysis tools are used in the spacecraft-design community to define and assess the local radiation levels. Among various radiation-transport/analysis tools available, SHIELDOSE-2 is commonly used in the early spacecraft-design phases because it has been established that it provides reasonably reliable results with relatively rapid computation time. The NASA Engineering and Safety Center initiated a two-phased study: (1) to better understand and document the SHIELDOSE-2 code capabilities and limitations, and (2) to identify alternative tools to use for cases where SHIELDOSE-2 is not applicable. This report provides a summary of the Phase 2 study.

SHIELDOSE-2↗

A space radiation shielding model of the Martian radiation environment experiment (MARIE)

The 2001 Mars Odyssey spacecraft was launched towards Mars on April 7, 2001. Onboard the spacecraft is the Martian radiation environment experiment (MARIE), which is designed to measure the background radiation environment due to galactic cosmic rays (GCR) and solar protons in the 20-500 MeV/n energy range. We present an approach for developing a space radiation-shielding model of the spacecraft that includes the MARIE instrument in the current mapping phase orientation. A discussion is presented describing the development and methodology used to construct the shielding model. For a given GCR model environment, using the current MARIE shielding model and the high-energy particle transport codes, dose rate values are compared with MARIE measurements during the early mapping phase in Mars orbit. The results show good agreement between the model calculations and the MARIE measurements as presented for the March 2002 dataset. c2003 COSPAR. Published by Elsevier Ltd. All rights reserved.

NASA Center JSC↗

Experimental and theoretical study of organometallic radiation-protective materials adapted to radiation sources with a complex isotopic composition

The significance of optimizing the content of components of a radiation-protective material, which is determined by the isotopic composition of radioactive contamination, depending on the reactor type, operating time, and other factors is demonstrated. The results of computational and experimental investigation of the gamma-radiation attenuation capacity of homogenous radiation-protective materials with different fillers are reported.

61 RADIATION PROTECTION AND DOSIMETRY↗

Black Carbon Radiative Forcing over the Tibetan Plateau

We estimate the snow albedo forcing and direct radiative forcing (DRF) of black carbon (BC) in the Tibetan Plateau using a global chemical transport model in conjunction with a stochastic snow model and a radiative transfer model. Our best estimate of the annual BC snow albedo forcing in the Plateau is 2.9 W m-2 (uncertainty: 1.5–5.0 W m-226 ). We find that BC-snow internal mixing increases the albedo forcing by 40-60% compared with external mixing and coated BC increases the forcing by 30-50% compared with uncoated BC, whereas Koch snowflakes reduce the forcing by 20-40% relative to spherical snow grains. Our best estimate of the annual BC DRF at the top of the atmosphere is 2.3 W m-2 (uncertainty: 0.7–4.3 W m-230 ) in the Plateau after scaling the modeled BC absorption optical depth to Aerosol Robotic Network (AERONET) observations. The BC forcings are attributed to emissions from different regions.

black carbon↗

Claudin-3 expression in radiation-exposed rat models: A potential marker for radiation-induced intestinal barrier failure

Highlights: • Irradiation increased intestinal bacterial translocation, accompanied by claudin protein expression in rats. • Neurotensin decreased the bacterial translocation and restored claudin-3 expression. • Claudin-3 can be used as a marker in evaluating radiation induced intestinal injury. - Abstract: The molecular events leading to radiation-induced intestinal barrier failure are not well known. The influence of the expression of claudin proteins in the presence and absence of neurotensin was investigated in radiation-exposed rat intestinal epithelium. Wistar rats were randomly divided into control, irradiation, and irradiation + neurotensin groups, and bacterial translocation to the mesenteric lymph node and expression of claudins were determined. Irradiation led to intestinal barrier failure as demonstrated by significant bacterial translocation. In irradiated terminal ilea, expression of claudin-3 and claudin-4 was significantly decreased, and claudin-2 expression was increased. Administration of neurotensin significantly reduced bacterial translocation and restored the structure of the villi as seen by histologic examination. Among the three subtype of claudins, only claudin-3 expression was restored. These results suggest that the therapeutic effect of neurotensin on the disruption of the intestinal barrier is associated with claudin-3 alteration and that claudin-3 could be used as a marker in evaluating radiation-induced intestinal injury.

60 APPLIED LIFE SCIENCES↗

Radiation-Induced Lymphocyte Apoptosis to Predict Radiation Therapy Late Toxicity in Prostate Cancer Patients

Purpose: To examine a potential correlation between the in vitro apoptotic response of lymphocytes to radiation and the risk of developing late gastrointestinal (GI)/genitourinary (GU) toxicity from radiotherapy for prostate cancer. Methods and Materials: Prostate cancer patients formerly enrolled in a randomized study were tested for radiosensitivity by using a radiation-induced lymphocyte apoptosis assay. Apoptosis was measured using flow cytometry-based Annexin-FITC/7AAD and DiOC{sub 6}/7AAD assays in subpopulations of lymphocytes (total lymphocytes, CD4+, CD8+ and CD4-/CD8-) after exposure to an in vitro dose of 0, 2, 4, or 8 Gy. Results: Patients with late toxicity after radiotherapy showed lower lymphocyte apoptotic responses to 8 Gy than patients who had not developed late toxicity (p = 0.01). All patients with late toxicity had apoptosis levels that were at or below the group mean. The negative predictive value in both apoptosis assays ranged from 95% to 100%, with sensitivity values of 83% to 100%. Apoptosis at lower dose points and in lymphocyte subpopulations had a weaker correlation with the occurrence of late toxicity. Conclusions: Lymphocyte apoptosis after 8 Gy of radiation has the potential to predict which patients will be spared late toxicity after radiation therapy. Further research should be performed to identify the specific subset of lymphocytes that correlates with late toxicity, followed by a corresponding prospective study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Dose-Volume Analysis of Radiation Pneumonitis in Non-Small Cell Lung Cancer Patients Treated With Stereotactic Body Radiation Therapy

Purpose: To examine the rates and risk factors of radiation pneumonitis (RP) in non-small cell lung cancer (NSCLC) patients treated with stereotactic body radiotherapy (SBRT). Methods and Materials: Dosimetry records for 251 patients with lymph node-negative Stage I-IIB NSCLC and no prior chest radiation therapy (RT) treated with SBRT were reviewed. Patients were coded on the basis of the presence of at least Grade (G) 2 RP using the Common Toxicity Criteria version 2 criteria. Radiation doses, V5, V10, V20, and mean lung dose (MLD) data points were extracted from the dose-volume histogram (DVH). Results: Median PTV volume was 48 cc. Median prescribed radiation dose was 60 Gy delivered in three fractions to the 80% isodose line. Median age at treatment was 74 years. Median follow-up was 17 months. RP was reported after treatment of 42 lesions: G1 in 19 (8%), G2 in 17 (7%), G3 in 5 (2%), and G4 in 1 (0.4%). Total lung DVHs were available for 143 patients. For evaluable patients, median MLD, V5, V10, and V20 were 4.1 Gy, 20%, 12%, and 4%, respectively. Median MLDs were 4 Gy and 5 Gy for G0-1 and G2-4 groups, respectively (p = 0.14); median V5 was 20% for G0-1 and 24% for G2-4 (p = 0.70); median V10 was 12% in G0-1 and 16% in G2-4 (p = 0.08), and median V20 was 4% in G0-1 and 6.6% in G2-4 (p = 0.05). G2-4 RP was noted in 4.3% of patients with MLD {<=}4 Gy compared with 17.6% of patients with MLD >4 Gy (p = 0.02), and in 4.3% of patients with V20 {<=}4% compared with 16.4% of patients with V20 >4% (p = 0.03). Conclusion: Overall rate of G2-4 RP in our population treated with SBRT was 9.4%. Development of symptomatic RP in this series correlated with MLD and V20.

62 RADIOLOGY AND NUCLEAR MEDICINE↗