Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Intraoperative Electron Beam Radiation Therapy (IOERT) Versus High-Dose-Rate Intraoperative Brachytherapy (HDR-IORT) in Patients With an R1 Resection for Locally Advanced or Locally Recurrent Rectal Cancer

Intraoperative radiation therapy (IORT), delivered by intraoperative electron beam radiation therapy (IOERT) or high-dose-rate intraoperative brachytherapy (HDR-IORT), may reduce the local recurrence rate in patients with locally advanced and locally recurrent rectal cancer (LARC and LRRC, respectively). The aim of this study was to compare the oncological outcomes between both IORT modalities in patients with LARC or LRRC who underwent a microscopic irradical (R1) resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Phase 1 Dose Escalation Study of Neoadjuvant SBRT Plus Elective Nodal Radiation with Concurrent Capecitabine for Resectable Pancreatic Cancer

The role of neoadjuvant radiation for resectable pancreatic adenocarcinoma is controversial. We performed a prospective dose-escalation study of neoadjuvant stereotactic body radiation therapy (SBRT) with concurrent capecitabine and elective nodal irradiation (ENI) followed by surgical resection to explore the toxicity and feasibility of this approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Dose-Escalated Chemoradiation on Quality of Life in Patients With Locally Advanced Rectal Cancer: 2-Year Follow-Up of the Randomized RECTAL-BOOST Trial

Dose-escalated chemoradiation (CRT) for locally advanced rectal cancer did not result in higher complete response rates but initiated more tumor regression in the randomized RECTAL-BOOST trial (Clinicaltrials.gov NCT01951521). This study compared patient reported outcomes between patients who received dose-escalated CRT (5 × 3 gray boost + CRT) or standard CRT for 2 years after randomization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of Receiver Operating Curve Analysis and Machine Learning With an Independent Dose Calculation System Reduces the Number of Physical Dose Measurements Required for Patient-Specific Quality Assurance

Our purpose was to assess the use of machine learning methods and Mobius 3D (M3D) dose calculation software to reduce the number of physical ion chamber (IC) dose measurements required for patient-specific quality assurance during corona virus disease 2019.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Archival records housed at USTUR support radium dial worker dosimetry

The American radium dial worker (RDW) cohort of over 3200 persons is being revisited as part of the Million Person Study (MPS) to include a modern approach to RDW dosimetry. An exceptional source of data and contextualization in this project is an extensive collection of electronic records (digitized from existing microfilm and microfiche) housed at the United States Transuranium and Uranium Registries (USTUR). Although the type, extent, and quality (e.g. legibility) of record(s) varies between individuals, the remarkable occupational, medical and demographic data include in vivo radiation measurements (e.g. radon breath, whole body counts), autopsy results, medical records (including copies of radiographs), interviews over the years, and correspondence. Of particular dosimetric interest are the details of radiation measurements. For example, there are some instances where hand-written and transcribed values are both available, along with notes providing context for why a particular measurement in a series of measurements was chosen to assign an intake, or if there were concerns about a particular measurement. Born prior to 1935, RDW have nearly all passed away. Thus, the updated dosimetry, especially for the skeletal tissues, will allow the correlation of lifetime cumulative dose with radiation risk. Here we review typical information available in this collection of historical records and highlight some interesting finds. Additionally, we discuss the relevance to current and ongoing work related to updating the dosimetry of the RDW in the MPS, including providing an example of the usefulness of information contained in these records. The RDW cohort provides a unique historical perspective on occupational exposure to radium, making it a valuable dataset for understanding long-term health effects and improving current radiation protection standards.

Million Person Study↗

Update to the Performance Assessment for the Savannah River Site Saltstone Disposal Facility - 20124

In 2019, Savannah River Remediation developed a revision to the performance assessment (PA) on behalf of the U.S. Department of Energy (DOE) Savannah River Operations Office (SR) for the near-surface disposal of low-level waste at the Savannah River Site (SRS) Saltstone Disposal Facility (SDF). Soluble waste from SRS Tank Farms undergoes salt processing to remove cesium and other high activity constituents. The low-activity decontaminated salt solution (DSS) is then immobilized by mixing it into a cementitious waste form known as saltstone. After mixing, the saltstone is poured into leak-tight concrete vaults, known as saltstone disposal units (SDUs), where the waste form cures. By the time of facility closure, the SDF is expected to consist of 15 SDUs with a combined capacity of 1.06 E+09 L (280 Mgal) of cured saltstone. The facility operates under a Disposal Authorization Statement (DAS) from DOE and a permit from the South Carolina Department of Health and Environmental Control (SCDHEC). Since the start of operations in 1990, the SDF has received almost 6.7 E+07 L (18 Mgal) of DSS, resulting in the safe disposal of 2.7 E+16 Bq (7.3 E+05 Ci) of activity. Due to the radioactive decay of short-lived contaminants, the total remaining activity in the disposed waste is estimated to be approximately 1.4 E+16 Bq (3.9 E+05 Ci), as of September 2018. The Disposal Authorization Statement requires a demonstration that the system of engineered and natural features of the disposal facility will limit releases from the facility and be protective of human health and the environment for at least the next 1,000 years. The long-term performance of the facility was evaluated under the requirements of the DoE's Radioactive Waste Management Manual (US DOE Manual 435.1-1). Simulations were performed to demonstrate that the disposal facility would meet performance objectives specified in the manual. The evaluation was based on numerical models that simulate the releases of contaminants from the saltstone waste form. Contaminants were transported through groundwater and air pathways to points of assessment to evaluate compliance. In addition, the potential consequences of an inadvertent human intrusion (IHI) were also evaluated. In accordance with the guidance and recommendations in US DoE's technical standard for DAS, deterministic and probabilistic analyses were performed to demonstrate the SDF system, which includes the engineered cover system, the SDUs, the waste form, and the natural features of the site, provides a reasonable expectation that saltstone disposal will meet performance objectives. Post-closure doses to future members of the public (MOP) were evaluated; dose estimates from the air pathway were well below the 1.0 E-04 Sv/yr (10 mrem/yr) performance objective within 1,000 years, and the calculated doses to the MOP from all exposure pathways, including the groundwater and air pathways, were well below the 2.5 E-04 Sv/yr (25 mrem/yr) performance objective within 1,000 years. Doses following an assumed intrusion event within the facility boundaries were well below the IHI performance objectives, where the acute IHI dose was below the acute IHI dose performance objective of 5.0 E-03 Sv (500 mrem) and the chronic IHI dose was below the chronic IHI dose performance objective of 1.0 E-03 Sv/yr (100 mrem/yr) within 1,000 years. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Energy Characterization of the UMD Electron Accelerator

Multiple different groups at Los Alamos National Laboratory have a cited interest in understanding the effects of ionizing radiation in materials. Of especial interest to the ISR division is understanding the effects in materials that are used in the space environment, where radiation is omnipresent and impossible to fully shield from. Development is under way to simulate the effects of radiation damage in detectors and electronics, primarily with particle transport codes such as Geant4 and RAMPART, a code that provides a user friendly interface to Geant4. However, these simulations need benchmarking to experimental tests, some of which have been performed at a variety of small electron accelerator facilities. One of these facilities is the Linear Electron Accelerator at the University of Maryland Radiation Facilities. This facility can provide electron beams on the order of 100 mA delivered in tight macropulse bunches, which allows for experiments where the behavior of electronics is monitored as a function of pulse number. While the beam rates per macropulse of this accelerator is monitored during an experiment via a current pick-off connected to a large graphite beamstop, the energy distribution of this electron beam is not measured during the experiment and has not been well characterized. The energy distribution of the beam is pertinent for these types of experiments, since dose is directly related to energy deposited in a medium. Further, these experiments are performed in open air and sample placement in the room can dictate what dose rate they receive per macropulse. We have created simulated dosemaps for the UMD vault room, but these simulations assume a given energy of the beam, both for calculating the dose and to simulate how much the beam diverges in the air. There have been two attempts now to characterize this accelerator beam energy with a plate type spectrometer, including the most recent experiment earlier this year to quantify the beam energy distribution. These results will also be compared to a dosimetry experiment performed by collaborators at the UMD facility, the details of which are described in Reference. Understanding the electron beam energy is important for future experiments, because the energy directly impacts the dose and radiation damage given to a sample and is important for properly simulating the electron beam when comparing simulation to experiment.

43 PARTICLE ACCELERATORS↗

Irradiation Vehicles for Evaluating SiC/SiC Cladding Bowing Under Neutron Flux Gradients

Silicon carbide fiber–reinforced silicon carbide matrix (SiC/SiC) composites are among the most promising candidates for long term accident-tolerant nuclear fuel cladding. A key challenge related to their deployment is lateral bowing caused by differential radiation-induced swelling under dose or temperature gradients, which could obstruct coolant flow or interfere with control rod/blade movements. Although previous modeling efforts have predicted bowing behavior in light-water reactor (LWR) environments, experimental validation remains limited, especially at prototypic LWR temperatures. This study addresses that gap by irradiating six reduced-length SiC/SiC cladding tubes (~600 mm) in the High Flux Isotope Reactor (HFIR) at ~300°C, which is representative of LWR conditions. The tubes will be housed in a sealed vessel with an inert gas gap to maintain target temperatures and prevent direct coolant contact. Arranged in three pairs, each set will receive a different radiation dose (low, medium, high), with the central pair receiving ~0.1 displacements per atom (dpa)—the expected dose for peak bowing. The experiment will determine the dose-dependent bowing behavior and validate predictive finite element models. In this work, the tubes are freely suspended from pins to allow for unconstrained bowing; however, we present a concept for introducing localized constraints to represent grid spacer effects. Post-irradiation examination will include swelling measurements and profilometry to assess bowing and compare the results with model predictions. This work aims to confirm the conditions under which maximum bowing occurs so as to improve the reliability of SiC/SiC performance models in nuclear applications.

Russell, Nick [ORNL] (ORCID:0000000296099820)↗