Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiation Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Interprofessional Image Verification Workshop for Physician and Physics Residents: A Multi-Institutional Experience

Verification of patient position through pretreatment setup imaging is crucial in modern radiation therapy. As treatment complexity increases and technology evolves, physicist-physician collaboration becomes imperative for safe and successful radiation delivery. Despite the importance of both, residency programs lack formal interprofessional education (IPE) activities or structured training for image verification. Here we show the impact of an interprofessional image verification workshop for residents in a multi-institutional setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiscale dynamic experiments on fiber-reinforced composites with damage assessment using high-speed synchrotron X-ray phase-contrast imaging

We report fiber-reinforced composites (FRCs) have been widely used as protection materials to replace heavier metals. However, predictive capabilities for the impact-induced failure of FRCs have not been well-developed. In this work, we introduced an integrated technique to visualize the dynamic failure of FRCs, with the modified Kolsky bar loading and the high-speed synchrotron X-ray phase-contrast imaging (PCI). We summarize our experimental studies across the FRCs’ structural levels by using this integrated technique, including single-fiber tensile experiments, fiber/matrix debonding experiments, and single-edge notched bending experiments on composite laminates. It is revealed that the high-speed synchrotron X-ray PCI technique possesses sufficient spatial resolution to identify the failure behavior of a single fiber in the 10-μm scale level, as well as temporal resolution to identify the time sequence of internal dynamic damage evolution. The technique can penetrate through the opaque composite sample and provide real-time visualization of small-scale damaging mechanisms such as the embedded fiber’s sliding in the matrix and the fiber’s transverse debonding with the matrix. At an expanding scale, the technique can identify the crack initiation and track the cracking behavior inside a single ply or between different plies of a composite laminate. High-speed visualization inside the material by this integrated technique provides critical deformation and failure information to develop physical understanding of the damage inside composites under impact.

47 OTHER INSTRUMENTATION↗

Ultracompact 3D microfluidics for time-resolved structural biology

To advance microfluidic integration, we present the use of two-photon additive manufacturing to fold 2D channel layouts into compact free-form 3D fluidic circuits with nanometer precision. We demonstrate this technique by tailoring microfluidic nozzles and mixers for time-resolved structural biology at X-ray free-electron lasers (XFELs). We achieve submicron jets with speeds exceeding 160 ms -1 , which allows for the use of megahertz XFEL repetition rates. By integrating an additional orifice, we implement a low consumption flow-focusing nozzle, which is validated by solving a hemoglobin structure. Also, aberration-free in operando X-ray microtomography is introduced to study efficient equivolumetric millisecond mixing in channels with 3D features integrated into the nozzle. Such devices can be printed in minutes by locally adjusting print resolution during fabrication. This technology has the potential to permit ultracompact devices and performance improvements through 3D flow optimization in all fields of microfluidic engineering.

3-D reconstruction↗

Experiments and simulations of isochorically heated warm dense carbon foam at the Texas Petawatt Laser

An experimental and simulation study of warm dense carbon foams at ambient density (n e ~10 21 cm –3 ) is presented. This study of isochorically heated foams is motivated by their potential application in carbon-atmosphere white-dwarf envelopes, where there are modeling uncertainties due to the equation of state. The foams are heated on an approximately picosecond time scale with a laser-accelerated proton beam. The cooling and expansion of the heated foams can be modeled with appropriately initialized radiation-hydrodynamics codes; xRAGE code is used in this work. The primary experimental diagnostic is the streaked optical pyrometer, which images a narrow band of radiation from the rear surface of the heated material. Presented are xRAGE modeling results for both solid aluminum targets and carbonized resorcinol-formaldehyde foam targets, showing that the foam appears to cool slowly on the pyrometer because of partial transparency. So that simulations of cooling foam are processed properly, it is necessary to account for finite optical depth in the photosphere calculation, and the methods for performing that calculation are presented in depth.

36 MATERIALS SCIENCE↗

Radiation Monitoring for Volatilized Zinc Contamination Using Gamma-Ray Imaging and Spectroscopy

Gamma-ray imaging is a tool that has grown in importance in the applications of non-destructive assay (NDA) for radioactive survey and analysis of nuclear facilities. Imaging techniques have shown great promise in providing valuable information involving radioactive waste management and contamination prevention. For the application studied in this work, 65 Zn has been identified as a radioactive contaminant during tritium extraction. Due to the volatile nature of 65 Zn under the pressure and temperature changes during extraction operations, 65 Zn can easily travel through components of the extraction system as vapor, making it difficult to trap. Previous research involving the development of a filtration system showed that the 65 Zn can be trapped, mitigating product contamination. However, during the extraction process, direct analysis of the equipment to confirm that zinc contamination is trapped in the filter and has not spread to other components is impractical. Here, in this situation, the need to assay the location of the contamination with little-to-no interference with operations is vital. In this work, we demonstrate the use of a commercialized 3D position-sensitive CdZnTe (CZT) gamma-ray imaging spectrometer to provide analysis of the 65 Zn contamination. Onsite measurements during an extraction process are studied to assess the location and migration of the 65 Zn. The results obtained from real-time glovebox monitoring demonstrate the feasibility of gamma-ray imaging for localizing the contamination and providing a preliminary qualitative assessment that is intended to be used in future work quantifying the contamination build-up and activity over time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Special Section Guest Editorial: Active Spectroscopy

A special edition of the journal Optical Engineering invited several scientists to participate in the editorial board of this special issue. The eleven papers in this special section cover recent developments in active spectroscopy, including new phenomenology and applications, advances in systems and components, and new methods for data processing and exploitation.

42 ENGINEERING↗

A VIPA Spectrograph with Ultra-high Resolution and Wavelength Calibration for Astronomical Applications

A prototype spectrograph using a Virtually Imaged Phased Array (VIPA) as the main dispersion element is presented, and its performance is fully examined in our laboratory. The single-mode, fiber-fed spectrograph with simultaneous wavelength calibration possesses a spectral resolution well in excess of R≈1.12×10{sup 6} while the size of the VIPA is several orders of magnitude smaller than that of a conventional échelle with comparable resolution. In laboratory tests, the VIPA-based instrument with a homemade Yb:fiber ring laser frequency comb demonstrates a mode-to-mode tracking stability of 41 cm s{sup −1} over a period of 6 hr. The VIPA spectrograph has promising applications in various astronomical observations in which ultra-high resolution and calibration precision are imperative, such as solar physics research, exoplanet searching with the radial velocity method, and O{sub 2} detection in the atmosphere of Earth-like planets. Ultimately, feasible optimizations for night-sky observations under seeing limited conditions are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Advances in turbine blade temperature measurements

Radiation pyrometry principles and imaging methods like photography and photoelectric scanning are combined to make accurate research quality temperature measurements on turbine airfoils. Two systems are described for obtaining detailed temperature distribution measurements: an infrared photographic system for stationary vanes and a photoelectric scanning system for rotating blades. An overview is presented outlining the design, calibration methods, and recent test results.

Pollack, F. G.↗

Advances in turbine blade temperature measurements

Radiation pyrometry principles and imaging methods like photography and photoelectric scanning are combined to make accurate research quality temperature measurements on turbine airfoils. Two systems are described for obtaining detailed temperature distribution measurements: an infrared photographic system for stationary vanes and a photoelectric scanning system for rotating blades. An overview is presented outlining the design, calibration methods, and recent test results

Pollack, F. G.↗

Survey of the Pioneer 10 and 11 Jupiter mission

After a description of the Pioneer 10 and 11 spacecraft, the following scientific experiments are discussed: Helium Vector Magnetometer, Fluxgate Magnetometer, Plasma Analyzer, Geiger Tube Telescope, Cosmic Ray Telescope, Trapped Radiation Detector, Ultraviolet Photometer, Imaging Photopolarimeter, Infrared Radiometer, Asteroid-Meteoroid Detector, and Meteoroid detector. Also reviewed are the mission profile and status.

Wolfe, J. H.↗

Radiance calibration of the High Altitude Observatory white-light coronagraph on Skylab

The processing of over 35,000 photographs of the solar corona obtained by the white-light coronograph on Skylab is described. Calibration of the vast amount of data was complicated by temporal effects of radiation fog and latent image loss. These effects were compensated by imaging a calibration step wedge on each data frame. Absolute calibration of the wedge was accomplished through comparison with a set of previously calibrated glass opal filters. Analysis employed average characteristic curves derived from measurements of step wedges from many frames within a given camera half-load. The net absolute accuracy of a given radiance measurement is estimated to be 20%.

Poland, A. I.↗

Construction and interpretation of a digital inertia image

An image representing the thermal inertia in the vicinity of Pisgah Crater and Lavic Lake in Southern California has been generated from visible, near IR, and thermal images taken from aircraft. Construction of the thermal inertia image required radiometric calibration and geometric rectification of the acquired images as well as registration to a topographic map. The Kahle thermal model used in the construction of the thermal inertia image requires specification of albedo, topographic slope and slope azimuth, diurnal temperature range and local meteorological conditions. Albedo information was derived from the visible image; digital topographic information was computed from digitized stereo aerial photographs; and thermal ranges were calculated by subtracting the predawn from the afternoon thermal image data. Our computed values of thermal inertia were in close agreement with published values for similar surface materials. Thermal inertia provides complementary information to conventional images of reflected solar radiation for use in lithologic mapping.

Gillespie, A. R.↗

Voyager 1 encounter with the Saturnian system

The Voyager 1 Saturn flyby mission of March 1979 is reviewed, with brief discussions of its flight, trajectory, science plan formulation and telemetered data. Analytical results of such data with respect to Saturn's atmosphere, rings, icy satellites, Titan satellite atmosphere and the Saturn magnetosphere, are summarized. The Voyager science investigations comprise imaging science (ISS), infrared radiation (IRIS), photopolarimetry (PPS), ultraviolet spectroscopy (UVS), radio science (RSS), magnetic fields (MAG), plasma particles (PLS), plasma waves (PWS), planetary radio astronomy (PRA), low energy charged particles (LECP), and cosmic-ray particles (CRS).

Stone, E. C.↗

Assessment of the first radiances received from the VSSR Atmospheric Sounder (VAS) instrument

The first orderly, calibrated radiances from the VAS-D instrument on the GOES-4 satellite are examined for: image quality, radiometric precision, radiation transfer verification at clear air radiosonde sites, regression retrieval accuracy, and mesoscale analysis features. Postlaunch problems involving calibration and data processing irregularities of scientific or operational significance are included. The radiances provide good visual and relative radiometric data for empirically conditioned retrievals of mesoscale temperature and moisture fields in clear air.

Chesters, D.↗