Search NASA⌕ Search

SEARCH · Search NASA

Results for “Range Safety”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

A novel measurement of marginal Alfven Eigenmode stability during high power auxiliary heating in JET

The interaction of Alfven Eigenmodes (AEs) and energetic particles is one of many important factors determining the success of future tokamaks. In JET, eight in-vessel antennas were installed to actively probe stable AEs with frequencies ranging 25-250 kHz and toroidal mode numbers |n| < 20. During the 2019-2020 deuterium campaign, almost 7500 resonances and their frequencies f0, net damping rates \gamma < 0, and toroidal mode numbers were measured in almost 800 plasma discharges. From a statistical analysis of this database, continuum and radiative damping are inferred to increase with edge safety factor, edge magnetic shear, and when including non-ideal effects. Both stable AE observations and their associated damping rates are found to decrease with |n|. Active antenna excitation is also found to be ineffective in H-mode as opposed to L-mode; this is likely due to the increased edge density gradient's effect on accessibility and ELM-related noise's impact on mode identification. A novel measurement is reported of a marginally stable, edge-localized Ellipticity-induced AE probed by the antennas during high-power auxiliary heating (ICRH and NBI) up to 25 MW. NOVA-K kinetic-MHD simulations show good agreement with experimental measurements of f0, \gamma, and n, indicating the dominance of continuum and electron Landau damping in this case. Similar experimental and computational studies are planned for the recent hydrogen and ongoing tritium campaigns, in preparation for the upcoming DT campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation Assessment of Turbulent Reacting Flow Model Using The Area-Validation Metric on Medium-Scale Methanol Pool Fire Results

Accident analysis and ensuring power plant safety are pivotal in the nuclear energy sector. Significant strides have been achieved over the past few decades regarding fire protection and safety, primarily centered on design and regulatory compliance. Yet, after the Fukushima accident a decade ago, the imperative to enhance measures against fire, internal flooding, and power loss has intensified. Hence, a comprehensive, multilayered protection strategy against severe accidents is needed. Consequently, gaining a deeper insight into pool fires and their behavior through extensive validated data can greatly aid in improving these measures using advanced validation techniques. A model validation study was performed at Sandia National Laboratories in which a 30-cm diameter methanol pool fire was modeled using the SIERRA/Fuego turbulent reacting flow code. This validation study used a standard validation experiment to compare model results against, and conclusions have been published. The fire was modeled with a Large Eddy Simulation (LES) turbulence model with subgrid turbulent kinetic energy closure. Combustion was modeled using a strained laminar flamelet library approach. Radiative heat transfer was accounted for with a model utilizing the gray-gas approximation. In the present study, additional validation analysis is performed using the area validation metric (AVM). These activities are done on multiple datasets involving different variables and temporal/spatial ranges and intervals. In conclusion, the results provide insight into the use of the area validation metric on such temporally varying datasets and the importance of physics-aware use of the metric for proper analysis.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Quantitative Risk Assessment for Fuel Cell Electric Bus Hydrogen Storage and Refueling Facility

It is necessary to understand the safety implications and risk mitigation options for fuel cell electric bus fleet deployment, especially for related facilities responsible for operations such as production, storage, compression, and dispensing of hydrogen for use by the buses. In this report, we present a quantitative risk assessment for a potential fuel cell electric bus fleet that was motivated by efforts to improve resilience at the Portland International Airport but can be applicable to a range of hydrogen case studies and use cases. We estimated risk for a facility that produces, stores, compresses, and dispenses hydrogen for the fleet of buses, with a focus on individual risk to people in terms of annual frequency of fatality. We considered the frequency of hydrogen leaks that could result in harmful physical outcomes like jet fires or explosions, and the consequences of those outcomes for people. We created customized fault trees to calculate the frequencies of different sizes of leaks and event sequence diagrams to calculate ignition probabilities for the various leak sizes. We also leveraged the HyRAM+ toolkit to use these inputs to calculate overall risk for the facility, which we separated into one section responsible for producing, storing, and compressing hydrogen, and one section responsible for dispensing the hydrogen to the buses. We found that the dispensing area seemed to have a higher risk than the production/storage/compression area of the facility, largely because of the inclusion of a component with a high leak frequency (the heat exchanger used to cool the hydrogen before entering the vehicle, to prevent overheating and expansion of hydrogen in the onboard tank). For the example production and refueling facility we evaluated and the data we used for the analysis, the leak frequency had a larger impact on the risk differences between the two sections on the facility, compared to the physical outcome consequence, which was slightly different due to the varying fuel conditions, but not substantially different. Actions can be taken to prevent these hazards (e.g., lowering leak frequencies in system components) or to mitigate the consequences if they do occur (e.g., installing barriers to protect people if ignition events occur). The choice of which actions to take depends not only on safety considerations but also on space, time, staffing, feasibility, and financial constraints. Therefore, the quantitative risk assessment approach can help understand relative risk contributions from different components, leak sizes, consequences, and human actions, to prioritize risk reduction strategies and balance these parameters. The outcomes of this report may be useful for a variety of stakeholders working in the hydrogen, transportation, vehicle, and aviation sector, including those responsible for aspects like facility design, operations, and regulations. There is not a single value of risk that determines whether a hypothetical system is “safe” or not. The insights about risk mitigations may be leveraged, and the quantitative risk assessment approach can be applied to other case studies to understand risk priorities and contributions specific to different FCEB and hydrogen facility uses.

08 HYDROGEN↗

High‐Pressure Characterization of Melt‐Castable Energetic Materials: Bis(Nitroxymethylisoxazolyl) Furoxan (DNDIF)

Abstract The high‐pressure behavior of bis(nitroxymethylisoxazolyl) furoxan (DNDIF) was studied at ambient temperature and pressures approaching 30 GPa by Raman spectroscopy and powder X‐ray diffraction. There was no evidence of a phase change observed over this pressure range, indicating that the ambient structure of DNDIF remains stable up to conditions similar to the detonation pressure of the material. Such findings suggest that this melt‐castable explosive may be used in the replacement of 2,4,6‐trinitrotoluene (TNT) in energetic formulations without the concern of uncontrolled polymorphism that might otherwise affect the performance and safety of the munition. Additionally, empirical understanding of the effect of different structural motifs in the crystal packing builds on understanding of what macroscale features are desirable for future materials and gets us closer to the design of future novel energetics.

Bennion, Jonathan C.↗

Advanced surrogate model for electron-scale turbulence in tokamak pedestals

We derive an advanced surrogate model for predicting turbulent transport at the edge of tokamaks driven by electron temperature gradient (ETG) modes. Our derivation is based on a recently developed sensitivity-driven sparse grid interpolation approach for uncertainty quantification and sensitivity analysis at scale, which informs the set of parameters that define the surrogate model as a scaling law. Our model reveals that ETG-driven electron heat flux is influenced by the safety factor q, electron beta β e and normalized electron Debye length λ D , in addition to well-established parameters such as the electron temperature and density gradients. To assess the trustworthiness of our model's predictions beyond training, we compute prediction intervals using bootstrapping. The surrogate model's predictive power is tested across a wide range of parameter values, including within-distribution testing parameters (to verify our model) as well as out-of-bounds and out-of-distribution testing (to validate the proposed model). Overall, validation efforts show that our model competes well with, or can even outperform, existing scaling laws in predicting ETG-driven transport.

fusion plasma↗

A novel measurement of marginal Alfvén eigenmode stability during high power auxiliary heating in JET

The interaction of Alfvén eigenmodes (AEs) and energetic particles is one of many important factors determining the success of future tokamaks. In JET, eight in-vessel antennas were installed to actively probe stable AEs with frequencies ranging 25–250 kHz and toroidal mode numbers |n| < 20. During the 2019–2020 deuterium campaign, almost 7500 resonances and their frequencies f 0 , net damping rates γ < 0, and toroidal mode numbers were measured in almost 800 plasma discharges. From a statistical analysis of this database, continuum and radiative damping are inferred to increase with edge safety factor, edge magnetic shear, and when including non-ideal effects. Both stable AE observations and their associated damping rates are found to decrease with |n|. Active antenna excitation is also found to be ineffective in H-mode as opposed to L-mode; this is likely due to the increased edge density gradient’s effect on accessibility and ELM-related noise’s impact on mode identification. A novel measurement is reported of a marginally stable, edge-localized ellipticity-induced AE probed by the antennas during high-power auxiliary heating (ion cyclotron resonance heating and neutral beam injection) up to 25 MW. NOVA-K kinetic-MHD simulations show good agreement with experimental measurements of f 0 , γ, and n, indicating the dominance of continuum and electron Landau damping in this case. Similar experimental and computational studies are planned for the recent hydrogen and ongoing tritium campaigns, in preparation for the upcoming DT campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

2023 Annual Site Environmental Report for Sandia National Laboratories, Tonopah Test Range, Nevada

Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration. The National Nuclear Security Administration’s Sandia Field Office administers the contract and oversees contractor operations at Sandia National Laboratories, Tonopah Test Range. Activities at the site are conducted in support of U.S. Department of Energy weapons programs and have operated at the site since 1957. The U.S. Department of Energy and its management and operating contractor are committed to safeguarding the environment, assessing sustainability practices, and ensuring the validity and accuracy of the monitoring data presented in this annual site environmental report. This report summarizes the environmental protection, restoration, and monitoring programs in place at Sandia National Laboratories, Tonopah Test Range during calendar year 2023. Environmental topics include cultural resource management, chemical management, air quality, ecology, environmental restoration, oil storage, site sustainability, terrestrial surveillance, waste management, water quality, wastewater discharge, and implementation of the National Environmental Policy Act. This report is prepared in accordance with and as required by DOE O 231.1B, Admin Change 1, Environment, Safety and Health Reporting, and has been approved for public distribution.

54 ENVIRONMENTAL SCIENCES↗

Implementing an Objectives-Driven, Risk-Informed, and Case-Assured Approach to Safety and Mission Success at NASA

NASA is developing a “Standard for Assurance of Space Flight Safety and Mission Success” that implements an objectives-driven, risk-informed, and case-assured approach to safety and mission success (S&MS) for NASA space flight programs and projects. The standard aligns with the philosophy of risk leadership that has recently been established in NASA policy to assure acceptable levels of flight crew safety and mission success risk. It is consistent with existing NASA risk management requirements and is compatible with NASA program management and systems engineering requirements. The methodology described in the standard is presented in terms of an S&MS assurance framework that is designed to allow substantial flexibility in the specific means by which programs and projects achieve acceptable mission S&MS risk. Such flexibility is necessary to accommodate the increasingly broad range of acquisition strategies employed by NASA, including commercial transportation services, as well as to accommodate the increasingly rapid evolution of space flight-related technologies and practices. A key feature of the S&MS assurance framework is the specification of S&MS success criteria for each life-cycle review (LCR). The S&MS assurance case is structured around these criteria, the satisfaction of which indicates that the program/project is adhering to the S&MS risk posture. This enables the evolving S&MS assurance case to be used as a fundamental program/project submittal at each LCR, where its inherent structure of argument, supported by evidence, directly supports the evaluation of the program/project with respect to the S&MS success criteria, and by extension, the S&MS risk posture. As such, the S&MS assurance case is integral to program/project systems engineering, risk management, and S&MS oversight activities, and provides the principal basis for S&MS risk acceptance by the Decision Authority throughout the program/project life cycle.

42 ENGINEERING↗

Sparge Sampling of Molten Salts for Online Monitoring via Laser-Induced Breakdown Spectroscopy

A method was developed to sample molten salts by sparging to generate and transport aerosols to an isolated instrument for compositional analysis by laser-induced breakdown spectroscopy (LIBS). Real-time monitoring of molten salt composition is critical to developing molten salt nuclear reactors, which offer enhanced safety and efficiency. In this article, the sparge sampling method is described and compared with sampling using a Collison nebulizer. The size distribution and transport of aerosols produced from molten eutectic NaNO 3 –KNO 3 salt were compared for multiple gas flow rates (75–1200 mL min –1 ) and transport distances (0.68–2.61 m). Both methods produced aerosols ranging from 0.5 to 5.0 μm determined using a cascade impactor. Aerosols were effectively transported without pre- or trace-heating of gas lines, but transport efficiency was reduced by the formation of agglomerates. Sparge sampling was found to use less sample and less gas than a Collison nebulizer while producing a more concentrated aerosol stream (up to 5 μg L –1 ). The effects of laser energy and delay time on the signal quality of LIBS measurements of these aerosols were also studied. High energy and short delay times were found to enhance signal and repeatability, whereas signal-to-background and signal-to-noise ratios were highest at low energy and longer delay times. The capabilities of this system for online monitoring of molten salts were demonstrated with calibrations for Sr and Li with relative standard deviations of 2.6% and 1.5% and limits of detection of 380 and 180 μg g –1 , respectively.

Aerosols↗

Effect of Drying on Corrosion Mitigation of Hanford Transfer Lines

Radioactive waste is stored in underground, carbon-steel double-shell tanks at the Department of Energy Hanford site. The waste is transferred between the tanks and other assets using the transfer lines spanning throughout the various tank farms at Hanford. The transfer lines consist of a pipe-in-pipe design, small diameter pipes, and are not piggable. Recent inspection data of the transfer lines have shown areas with corrosion on both interior of the encasements and exterior of the primary pipes, with nearly 50 percent wall loss on the primary pipes and nearly 25% wall loss on the encasement pipes due to pitting corrosion. The visual inspections of the transfer lines have shown presence of corrosion products near the pipeline risers and beyond. It has been hypothesized that the corrosion is predominantly due to the high humidity conditions and in some cases is driven by the presence of residual hydrotest water in the encasement and the associated contact with the safety significant primary pipe. Therefore, drying of the transfer lines could lead to corrosion mitigation. Experimental studies are being conducted to understand the effect of environmental conditions, especially, relative humidity and temperature, on transfer line grade carbon steel corrosion and on mitigating corrosion. The experimental conditions are selected based on the seasonal temperature changes, and relative humidity conditions ranging from 30 to 100 percent. The experimental data will be used as guidance for maintaining a dry environment that will help mitigate the transfer-line corrosion caused by the high humidity conditions.

Shukla, Pavan K.↗

Dedicated short range communications used as fail-safe in autonomous navigation

Here in this paper, we have analyzed scenarios for leader-follower vehicle convoys that have the potential to be unsafe, hazardous, or even fatal in order to provide insight on dangerous driving conditions for autonomous vehicle platoons. These scenarios were created in a simulation software called Prescan, and are made to reflect the behavior of the vehicle dynamics and sensor characteristics of a real-world vehicle convoy that is currently being tested at the American Center for Mobility (ACM) and sponsored by the Department of Energy (DOE), National Renewable Energy Laboratory (NREL), the U.S. Army Combat Capabilities Development Command - Ground Vehicle Systems Center (U.S. Army CC-DEVCOM) and the Michigan Department of Transportation (MDOT). The follower vehicle in this study is tested under multiple scenarios, equipped with a Dedicated Short Range vehicle-to-vehicle communication system (DSRC), a radar-based adaptive cruise control system (ACC) and a precision global positioning system (GPS).

42 ENGINEERING↗

Integrated Spatial, Spectral, & Temporal Optical Reflectance System for Precision Occupancy & Location Sensing to Improve Building Energy Efficiency

Buildings consume approximately 35% of the electricity used in the U.S. and building owners can significantly reduce this energy use by providing services like heating, electrical power and lighting only when people are present. The ARPAe funded program titled “INTEGRATED SPATIAL, SPECTRAL, & TEMPORAL OPTICAL REFLECTANCE SYSTEM FOR PRECISION OCCUPANCY & LOCATION SENSING TO IMPROVE BUILDING ENERGY EFFICIENCY” demonstrates how a low cost sensor technology developed for measuring distances can be used to count and locate occupants with a high degree of precision with a very low error rates. This platform tells a building control system where occupants are located (but not who they are) so that energy consuming services can be provided only when the services are needed by building occupants. The original proof of concept involved using low cost, commercially available time-of-flight (TOF) sensors that measure distance, but the performance of these existing sensors was lacking, as they could not operate properly in the presence of sunlight, which blinded the simple TOF sensors and limited their utility in buildings. This project proposed a powerful new class of TOF sensors that used state-of-the-art integrated circuit (IC) fabrication processes that combined advanced photonics with conventional silicon chip circuitry for improved sensor performance. An equally important part of this project was to find ways to maximize occupant count and location accuracy while using the fewest number of sensors possible, in order to keep costs low. By using building blueprints to create digital twins of commercial building spaces, the team developed new algorithms to maximize occupant count and tracking accuracy by properly locating the minimum number of sensors at just the right spots in the building. This capability not only minimizes system costs but also simplified sensor installation and system commissioning. Our simulations of our sensor networks for a range of commercial floorplan designs demonstrated that our installed cost target of $0.08/sqft was attainable, though not fully demonstrated during the project. Finally, we noted that the TOF sensor concept could provide a valuable role in health and eldercare by tracking patients without the need for worn sensors and would be useful for fall detection and other patient safety metrics, including tracking healthcare/patient interactions. We feel that, when fully developed, this new class of sophisticated TOF sensors and support software will be a powerful new approach to improving building energy efficiency based on occupant centric control platforms and will also open new levels of patient safety in healthcare operations. To realize this potential, the team formed the Troy Sensor Company LLC to oversee licensing of the programs patents and continue to seek commercialization of this program’s activity sensing technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Revolutionizing thermal Management in Next-Generation AI data centers: Challenges and breakthrough innovations

Data centers (DCs) serve as critical infrastructure for powering the growth and evolution of AI. Next-generation AI DCs present unique challenges in thermal management driven by unprecedented computational demands. This paper provides a comprehensive summary of key stakeholder perspectives on technology gaps, infrastructure requirements, test bed needs, emerging opportunities, and preliminary solutions related to thermal management for AI DCs. It establishes six strategic pillars of thermal management for next generation AI DC: reliability, deployability, efficiency, resilience, measurability, and valorization. The discussion spans a range of critical topics, including advanced cooling technologies, thermal strategies for emerging modular and edge DCs, system-level optimization and control frameworks, infrastructure planning and grid integration designs, benchmarking approaches, and pathways for waste heat recovery and reuse. The proposed research, development, and demonstration efforts are aimed at accelerating the deployment of AI DCs while ensuring energy efficiency, reliability, safety, and regulatory compliance.

Wang, Pengtao [ORNL] (ORCID:0000000214713429)↗

Modeling reactivity insertion experiments of TRISO particles in NSRR using BISON

This research presents BISON simulations of stress, temperature, and failure probability of tristructural isotropic (TRISO) fuel particles subjected to transient power pulse conditions in the Nuclear Safety Research Reactor (NSRR). We report that by modifying the default elastic properties of the PyC and the UO 2 coefficient of thermal expansion correlation, BISON was found to produce suitable agreement with the observed and independently simulated results when appropriate shape and scale Weibull parameters for SiC failure were chosen. The Weibull parameter effects were also explored within the range of SiC failure and were applied using experimental data from hemispherical crush testing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

LANL update to 239 Pu in the fast energy range [Slides]

Researchers are in the process of updating the Pu cross sections in the fast energy range (complementing the work of IAEA / INDEN / ORNL lower energy work in the resonance range). LANL is overhauling its evaluation tools (CoH, CGMF, DeCE, Kalman, NEXUS, PySOK, SOK) and focusing on consistency throughout evaluation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Housing-Performance Atlas of Baltimore Row Homes: Archetype-Based Multi-Hazard Baseline of Energy, Heat, Survivability, and Durability

Baltimore’s historic row-home neighborhoods face escalating risks to energy, heat, and durability under intensifying climate stress. This study develops a Housing-Performance Atlas that quantifies multi-hazard performance for eight representative archetypes using DesignBuilder/EnergyPlus Version 7.3.1.003, under Baltimore TMY3 boundary conditions. Performance is evaluated across the following four adaptation domains: energy use intensity, passive survivability during 72 h outage events, roof overheating exposure (>150 °F exceedance hours), and material service life derived from ISO 15686 and synthesized into Lean and Full Deficit Indices for comparative resilience ranking. Results show that EUI ranged from 46.7 to 67.6 kBtu ft −2 ·yr −1 , survivability from 0 to 23 h, and roof temperatures exceeded 150 °F for 150–210 h, shortening roof service life by up to 10 years. Composite Lean and Full Deficit Indices ranged 7.8–92.4, ranking Model 5 (end-unit, flat roof, two-story with basement) as the most resilient configuration and Model 8 (end-unit, pitched roof, three-story above-grade) as the least resilient due to compounded overheating and energy losses. Heat-related domains accounted for nearly 70% of overall resilience deficits, confirming thermal safety and roof reflectivity as retrofit priorities. The Housing-Performance Atlas establishes a reproducible diagnostic framework linking simulation, service life, and resilience metrics to guide cost-effective, climate-responsive retrofits in Baltimore’s aging urban housing stock.

Housing-Performance atlas↗

Progress Towards the Reality of Low-Temperature Critical Experiments with Low-Temperature TEX

Integral benchmarks for criticality safety do not exist below room temperature. Incredible support for below room temperature benchmarks is present across the international community. Validation of low-temperature neutron cross sections is necessary to verify any operation at temperatures below room temperature which is typically observed in environments far from the equator. For example, a fissile material transportation truck may routinely observe ambient temperatures down to -40°C, which is the lower temperature bound of the normal conditions of transportation defined in the United States Title 10 Code of Federal Regulations §71.71c2. Similarly, the IAEA, which contains 176 member states, has the same requirement for subcriticality for fissile material transportation. Additionally, sub-room temperature benchmarks can validate newly produced cross sections, that include novel thermal scattering laws, from North Carolina State University. A six-case experiment designed based off the TEX-HEU baseline experiments has been proposed utilizing a chilled vacuum chamber capable of cooling the HEU stack down to -50°C. The six proposed configurations span the entire neutron fission energy range and can be tested at intermediate temperatures between room temperature and -40°C. Of the six configurations, the fastest case utilizes nearly 135 kg of HEU. Understanding the system is required prior to critical experiment operations. In order to test the functionality of the system, testing with surrogate fuel materials has been conducted. The following discusses the design of the low temperature TEX (LT-TEX) experiment as well as the progress made via surrogate testing towards a reality in which low-temperature integral benchmarks exist in the International Criticality Safety Benchmark Evaluation Project (ICSBEP).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Safety Compliance Verification of Fuel Cell Electric Vehicle Exhaust

NREL has been developing compliance verification tools for allowable hydrogen levels prescribed by the Global Technical Regulation Number 13 (GTR-13) for hydrogen fuel cell electric vehicles (FCEVs). As per GTR-13, FCEV exhaust is to remain below 4 vol% H2 over a 3-second moving average and shall not at any time exceed 8 vol% H2 and that this requirement is to be verified with an analyzer that has a response time of less than 300 ms. To be enforceable, a means to verify regulatory requirements must exist. In response to this need, NREL developed a prototype analyzer that meets the GTR metrological requirements for FCEV exhaust analysis. The analyzer was tested on a commercial fuel cell electric vehicle (FCEV) under simulated driving conditions using a chassis dynamometer at the Emissions Research and Measurement Section of Environment and Climate Change Canada and FCEV exhaust was successfully profiled. Although the prototype FCEV Exhaust Analyzer met the metrological requirements of GTR-13, the stability of the hydrogen sensor was adversely impacted by condensed water in the sample gas. FCEV exhaust is at an elevated temperature and nearly saturated with water vapor. Furthermore, condensed water is present in the form of droplets. Condensed water in the sample gas can collect on the hydrogen sensing element, which would not only block access of hydrogen to the sensor but can also permanently damage the sensor. In the past year, the design of the gas sampling system was modified to mitigate against the transport of liquid water to the sensing element. Laboratory testing confirmed the effectiveness of the modified sampling system water removal strategy while maintaining the measurement range and response time required by GTR-13. Testing of the upgraded analyzer design on an FCEV operating on a chassis dynamometer is scheduled for the summer of 2021.

DIRECT ENERGY CONVERSION,HYDROGEN↗