Search NASA⌕ Search

SEARCH · Search NASA

Results for “Rankine”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

Numerical computation of two dimensional viscous blunt body flows with an impinging shock, part 2

Two-dimensional viscous blunt body flows with an impinging shock have been computed using a time-dependent finite-difference method which solves the complete set of Navier-Stokes equations for a compressible flow. For low Reynolds number flows, the entire flow field, including the bow shock and impinging shock, has been captured in the computation. For higher Reynolds number flows, the bow shock is treated as a discontinuity across which the Rankine-Hugoniot equations are applied, while the boundary layer and interaction regions are captured as before. Using this latter shock-fitting approach, a Type III shock interaction flow field has been computed with flow conditions corresponding to the space shuttle orbiter freestream conditions at 61 km (200,000 ft).

Holst, T. L.↗

Demonstration of a pulsing liquid hydrogen/liquid oxygen thruster

The development of an injector/thruster concept capable of pulsing a liquid hydrogen/liquid oxygen attitude control propulsion system thruster over thrust and chamber-pressure ranges of 625 to 1250 lbF and 250 to 500 psia, respectively, is discussed. It is shown how continuing search for a simple light-weight, high-performance reaction control system concept led to successful operation tests at cryogenic propellant temperatures (150 and 45 degrees Rankine for oxygen and hydrogen, respectively). The analytical and experimental phases of the liquid/liquid thruster technology efforts are examined.

Herr, P. N.↗

Interrelated structures of the transport shock and collisional relaxation layer in a multitemperature, multilevel ionized gas

The gas dynamic structures of the transport shock and the downstream collisional relaxation layer are evaluated for partially ionized monatomic gases. Elastic and inelastic collisional nonequilibrium effects are taken into consideration. In the microscopic model of the atom, three electronic levels are accounted for. By using an asymptotic technique, the shock morphology is found on a continuum flow basis. This procedure gives two distinct layers in which the nonequilibrium effects to be considered are different. A transport shock appears as the inner solution to an outer collisional relaxation layer. The results show four main interesting points: (1) on structuring the transport shock, ionization and excitation rates must be included in the formulation, since the flow is not frozen with respect to the population of the different electronic levels; (2) an electron temperature precursor appears at the beginning of the transport shock; (3) the collisional layer is rationally reduced to quadrature for special initial conditions, which (4) are obtained from new Rankine-Hugoniot relations for the inner shock.

Vinolo, A. R.↗

Hypervelocity impact heating of porous aluminum

Estimates of the thermal energy and other properties of the postshock condition are obtained for porous aluminum targets impacted by iron or aluminum projectiles, in the shock pressure range between about 0.4 and 8 Mbar. The starting point is the determination of a distinct Hugoniot equation for each value of porosity, from available experimental data. Rankine-Hugoniot equations and a Mie-Gruneisen equation of state supply the relations necessary for finding the thermodynamic properties of adiabatically relaxed materials. The results are of interest in such fields as ablation studies, meteoritics, and lunar topography.

Rehfuss, D. E.↗

Status of the NASA-Lewis flat-plate collector tests with a solar simulator

Simulator test results of 15 collector types are presented. Collectors are given performance ratings according to their use for pool heating, hot water, absorption A/C or heating, and solar Rankine machines. Collectors found to be good performers in the above categories, except for pool heating, were a black nickel coated, 2 glass collector, and a black paint 2 glass collector containing a mylar honeycomb. For pool heating, a black paint, one glass collector was found to be the best performer. Collector performance parameters of 5 collector types were determined to aid in explaining the factors that govern performance. The two factors that had the greatest effect on collector performance were the collector heat loss and the coating absorptivity.

Simon, F. F.↗

Technology of forced flow and once-through boiling: A survey

Representative boiling heat transfer and pressure drop information obtained primarily from past NASA and AEC programs is presented which is applicable to forced flow and once-through boiler systems. The forced convection boiler has a number of advantages: little possibility of flow mal-distribution; heat transfer characteristics are usually consistent; and conductances are predictable, so that higher heat fluxes may be employed with safety (which leads to more compact, lighter weight equipment). It was found that in gas-fired systems particularly, the controlling heat transfer resistance may be on the hot side, so that increased fluxes would require extended surfaces. If in a power generation system the working fluid is very expensive, a forced flow boiler can be designed especially for small holdup volume. If the fluid is temperature sensitive, the boiling side wall temperatures can be tailored to maintain maximum heat transfer rates without overheating the fluid. The forced flow and once-through configurations may be the only type which can satisfy a specific need (such as the automotive Rankine cycle power plant design having a very short time-response boiler).

Poppendieck, H. F.↗

System analysis of a piston steam engine employing the uniflow principle, a study in optimized performance

Results are reported which were obtained from a mathematical model of a generalized piston steam engine configuration employing the uniflow principal. The model accounted for the effects of clearance volume, compression work, and release volume. A simple solution is presented which characterizes optimum performance of the steam engine, based on miles per gallon. Development of the mathematical model is presented. The relationship between efficiency and miles per gallon is developed. An approach to steam car analysis and design is presented which has purpose rather than lucky hopefulness. A practical engine design is proposed which correlates to the definition of the type engine used. This engine integrates several system components into the engine structure. All conclusions relate to the classical Rankine Cycle.

Peoples, J. A.↗

A numerical determination of the bow shock wave in transonic axisymmetric flow about blunt bodies

A numerical method was developed for calculating axisymmetric transonic (M greater than 1) flow about a blunt body; the bow shock wave location was investigated. A Rankine-Hugoniot jump was applied at the shock while relaxation on the isentropic equation of motion was used between shock and body. The shock wave is adjusted by a Newton type iteration scheme. Results are given for a sphere in the Mach number range 1.62 down to 1.02.

Jones, D. J.↗

Liquid-metal binary cycles for stationary power

The use of topping cycles to increase electric power plant efficiency is discussed, with particular attention to mercury and alkali metal Rankine cycle systems that could be considered for topping cycle applications. An overview of this technology, possible system applications, the required development, and possible problem areas is presented.

Gutstein, M.↗

Solar collector performance evaluation with the NASA-Lewis solar simulator-results for an all-glass-evacuated-tubular selectively-coated collector with a diffuse reflector

A solar collector was tested in a solar simulator for inlet temperatures of temperatures of 70 to 200 F, flux levels of 230 and rate of 7 lb/(hr)(sq. ft), and incident angles of 0 deg, 33 deg, and 52 deg. Test results plotted in a form suggested by analysis indicate a very low heat loss coefficient. The collector shows excellent performance on an all-day performance basis, and also for conditions corresponding to temperatures required in solar Rankine systems and/or for low flux level radiation.

Simon, F.↗

Forced-flow once-through boilers

A compilation and review of NASA-sponsored research on boilers for use in spacecraft electrical power generation systems is presented. Emphasis is on the heat-transfer and fluid-flow problems. In addition to space applications, much of the boiler technology is applicable to terrestrial and marine uses such as vehicular power, electrical power generation, vapor generation, and heating and cooling. Related research areas are discussed such as condensation, cavitation, line and boiler dynamics, the SNAP-8 project (Mercury-Rankine cycle), and conventional terrestrial boilers (either supercritical or gravity-assisted liquid-vapor separation types). The research effort was directed at developing the technology for once-through compact boilers with high heat fluxes to generate dry vapor stably, without utilizing gravity for phase separations. A background section that discusses, tutorially, the complex aspects of the boiling process is presented. Discussions of tests on alkali metals are interspersed with those on water and other fluids on a phenomenological basis.

Stone, J. R.↗

Flat-Plate Solar-Collector Performance Evaluation with a Solar Simulator as a Basis for Collector Selection and Performance Prediction

The use of a solar simulator for performance determination permits collector testing under standard conditions of wind, ambient temperature, flow rate and sun. The performance results determined with the simulator have been found to be in good agreement with outdoor performance results. The measured thermal efficiency and evaluation of 23 collectors are reported which differ according to absorber material (copper, aluminum, steel), absorber coating (nonselective black paint, selective copper oxide, selective black nickel, selective black chrome), type of glazing material (glass, Tedlar, Lexan, antireflection glass), the use of honeycomb material and the use of vacuum to prevent thermal convection losses. The collectors were given performance rankings based on noon-hour solar conditions and all-day solar conditions. The determination with the simulator of an all-day collector performance was made possible by tests at different incident angles. The solar performance rankings were made based on whether the collector is to be used for pool heating, hot water, absorption air conditioning, heating, or for a solar Rankine machine.

Simon, F. F.↗

Status of the NASA-Lewis flat-plate collector tests with a solar simulator

Simulator test results of 15 collector types are reported. Collectors are given performance ratings according to their use for pool heating, hot water, absorption A/C or heating and solar Rankine machines. Collectors found to be good performers in the above categories, except for pool heating, were a black nickel coated, 2 glass collector, and a black paint 2 glass collector containing a mylar honeycomb. For pool heating, a black paint, one glass collector was found to be the best performer. Collector performance parameters of 5 collector types were determined to aid in explaining the factors that govern performance. The two factors that had the greatest effect on collector performance were the collector heat loss and the coating absorptivity.

Simon, F. F.↗

The UF6 Breeder - A solution to the problems of nuclear power

One of the major advantages of uranium hexafluoride reactors for power generation is the simplified fuel reprocessing scheme which the gaseous fuel makes possible. Critical experiments related to the development of the reactors for electric power generation are discussed along with UF6 breeder reactor studies. Previous energy conversion studies are reported, taking into account gas turbine power plants, thermionic conversion, and MHD conversion. Thermodynamic cycle analyses show that high efficiencies can be achieved using UF6 as the working fluid for Rankine or Brayton cycles without requiring excessive temperatures.

Williams, J. R.↗

Flat-plate solar-collector performance evaluation with a solar simulator as a basis for collector selection and performance prediction

This paper reports the measured thermal efficiency and evaluation of 23 collectors which differ according to absorber material (copper, aluminum, steel), absorber coating (nonselective black paint, selective copper oxide, selective black nickel, selective black chrome), type of glazing material (glass, Tedlar, Lexan, anti-reflection glass), the use of honeycomb material and the use of vacuum to prevent thermal convection losses. The collectors are given performance rankings based on noon-hour solar conditions and all-day solar conditions. The determination with the simulator of an all-day collector performance is made possible by tests at different incident angles. The solar performance rankings are made based on whether the collector is to be used for pool heating, hot water, absorption air conditioning, heating, or for a solar Rankine machine.

Simon, F. F.↗

Thermodynamic cycle analysis

An analysis was made of Rankine cycle efficiency in nuclear power plants with and without reheat capabilities. In addition, temperatures and pressures at certain selected locations were carried out to optimize plant efficiency. It was determined that plant efficiency without reheat was 39.03%, with reheat, a maximum efficiency of 4.44% was obtained at a pressure of 435.12 psia. Data also indicate efficiency appears to increase for pressures greater than 720 psia. However, higher pressures cannot be used because calculations indicate these pressure reheat temperatures exceed 1650 R, which is not allowed due to material limitations.

Source record↗

Development of a solar-powered residential air conditioner

The initial objective of the program was the optimization (in terms of cost and performance) of a Rankine cycle mechanical refrigeration system which utilizes thermal energy from a flat solar collector for air conditioning residential buildings. However, feasibility investigations of the adsorption process revealed that a dessicant-type air conditioner offers many significant advantages. As a result, limited efforts were expended toward the optimization of such a system.

Source record↗