Irradiated stainless steel 347 and irradiated, welded, and hydrogen charged Zircaloy-4 property data for the target solution vessel and support lines of SHINE
In support of the reactor-vessel development effort of SHINE medical technologies, irradiation of its structural materials and post-irradiation testing have been performed in the High Flux Isotope Reactor at Oak Ridge National Laboratory. This irradiation was performed on welded and unwelded AISI 347 steel and Zircaloy-4 samples at low temperature (~60°C) in contact with the reactor coolant. Hardness, Charpy, and tensile data have been taken from all cases of unirradiated specimens, while post-irradiation tensile and hardness data have been taken from AISI 347 base metal and Zircaloy-4 base metal and weld specimens so far. Additionally, 3-point bend data have been taken from explosion-welded specimens. The expected changes to hardness, yield strength, ultimate tensile strength, uniform elongation, and total elongation as a result of the low temperature and low dose neutron irradiation are reported here.