Search NASA⌕ Search

SEARCH · Search NASA

Results for “Response Spectra”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20

The interpretation of SN-v signals in terrestrial experiments through the folding procedure

The convolution (folding) procedure is applied in order to explore the response of Zn isotopes to the energy-spectra of the supernova neutrinos. At first, double differential cross sections are calculated in the context of the quasi-particle random phase approximation (QRPA) and, then, the cross sections obtained are folded with reliable energy distributions of supernova neutrino spectra. This leads to folded double, integrated, cumulative and total cross sections describing the nuclear response of the Zn isotopes as supernova neutrino detectors. Preliminary results of convoluted neutral-current neutrino-nucleus cross sections for the {sup 64}Zn isotope are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Contact resonances of U-shaped atomic force microscope probes

Recent approaches used to characterize the elastic or viscoelastic properties of materials with nanoscale resolution have focused on the contact resonances of atomic force microscope (CR-AFM) probes. The experiments for these CR-AFM methods involve measurement of several contact resonances from which the resonant frequency and peak width are found. The contact resonance values are then compared with the noncontact values in order for the sample properties to be evaluated. The data analysis requires vibration models associated with the probe during contact in order for the beam response to be deconvolved from the measured spectra. To date, the majority of CR-AFM research has used rectangular probes that have a relatively simple vibration response. Recently, U-shaped AFM probes have created much interest because they allow local sample heating. However, the vibration response of these probes is much more complex such that CR-AFM is still in its infancy. In this article, a simplified analytical model of U-shaped probes is evaluated for contact resonance applications relative to a more complex finite element (FE) computational model. The tip-sample contact is modeled using three orthogonal Kelvin-Voigt elements such that the resonant frequency and peak width of each mode are functions of the contact conditions. For the purely elastic case, the frequency results of the simple model are within 8% of the FE model for the lowest six modes over a wide range of contact stiffness values. Results for the viscoelastic contact problem for which the quality factor of the lowest six modes is compared show agreement to within 13%. These results suggest that this simple model can be used effectively to evaluate CR-AFM experimental results during AFM scanning such that quantitative mapping of viscoelastic properties may be possible using U-shaped probes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Contact resonance atomic force microscopy imaging in air and water using photothermal excitation

Contact Resonance Force Microscopy (CR-FM) is a leading atomic force microscopy technique for measuring viscoelastic nano-mechanical properties. Conventional piezo-excited CR-FM measurements have been limited to imaging in air, since the “forest of peaks” frequency response associated with acoustic excitation methods effectively masks the true cantilever resonance. Using photothermal excitation results in clean contact, resonance spectra that closely match the ideal frequency response of the cantilever, allowing unambiguous and simple resonance frequency and quality factor measurements in air and liquids alike. This extends the capabilities of CR-FM to biologically relevant and other soft samples in liquid environments. We demonstrate CR-FM in air and water on both stiff silicon/titanium samples and softer polystyrene-polyethylene-polypropylene polymer samples with the quantitative moduli having very good agreement between expected and measured values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated Chemical and Microorganism Monitoring of Air Using Gas Chromatography/Ion Mobility Spectometry: Toward an Expanded-Use Volatile Organic Analyzer (VOA)

The work described in this research program originated with the choice by NASA of an ion mobility spectrometer for air quality monitoring on-board the international spacestation. Though the gas chromatograph-ion mobility spectrometer analyzer known as VOA met or exceeded expectations, limitations in the basic understanding of response and the utilization of foundational principles into usable technology was considered unacceptable. In this research program, a comprehensive model for the origins of mobility spectra was proposed, tested and verified. The principles considered responsible for the appearance of mobility spectra have now been elucidated through this project. This understanding has been applied in automated identification of mobility spectra using neural networks and routine procedures for this now exist. Finally, the limitation on linear range has been shown to be a technical limitation and not a fundamental limitation so that a hardware component was crafted to extend the linear range of a mobility spectrometer by 10X. This project has led to one Ph.D. dissertation and one MS thesis. In addition, over ten public presentations at professional meetings and six journal publications have resulted from this program of research. The findings are so plentiful that total analysis of the findings may require four to six years or more. The findings confirm that the decision to use VOA was sound and that the chemical and physical principles of mobility spectrometry are both understandable and predictable.

Eiceman, G. A.↗

Response to 'Comment on 'Continuum modes in rotating plasmas: General equations and continuous spectra for large aspect ratio tokamaks' '[Phys. Plasmas 19, 064701 (2012)]

The equations for the continuous spectra derived in our paper [V. P. Lakhin and V. I. Ilgisonis, Phys. Plasmas 18, 092103 (2011)] can be reduced to the matrix form used by Goedbloed et al.[Phys. Plasmas 11, 28 (2004)]. It is shown that the assumptions made in our paper provide the elliptic flow regime and guarantee the existence of plasma equilibrium with nested magnetic surfaces of circular cross-section. The new results on magnetohydrodynamic instabilities of such tokamak equilibria obtained in our paper but absent in the paper by Goedbloed et al. are emphasized.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tuning extreme ultraviolet emission for optimum coupling with multilayer mirrors for future lithography through control of ionic charge states

We report on the identification of the optimum plasma conditions for a laser-produced plasma source for efficient coupling with multilayer mirrors at 6.x nm for beyond extreme ultraviolet lithography. A small shift to lower energies of the peak emission for Nd:YAG laser-produced gadolinium plasmas was observed with increasing laser power density. Charge-defined emission spectra were observed in electron beam ion trap (EBIT) studies and the charge states responsible identified by use of the flexible atomic code (FAC). The EBIT spectra displayed a larger systematic shift of the peak wavelength of intense emission at 6.x nm to longer wavelengths with increasing ionic charge. This combination of spectra enabled the key ion stage to be confirmed as Gd{sup 18+}, over a range of laser power densities, with contributions from Gd{sup 17+} and Gd{sup 19+} responsible for the slight shift to longer wavelengths in the laser-plasma spectra. The FAC calculation also identified the origin of observed out-of-band emission and the charge states responsible.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Seasonal Change on Saturn from Cassini/CIRS Observations, 2004-2009

Five years of thermal infrared spectra from the Cassini Composite Infrared Spectrometer (CIRS) are analyzed to determine the response of Saturn's atmosphere to seasonal changes in insolation. Hemispheric mapping sequences at 15.0 cm-1 spectral resolution are used to retrieve the variation in the zonal mean temperatures in the stratosphere (0.5-5.0 mbar) and upper troposphere (75-800 mbar) between October 2004 (shortly after the summer solstice in the southern hemisphere) and July 2009 (shortly before the autumnal equinox). Saturn's northern mid-latitudes show signs of dramatic warming in the stratosphere (by 6-10 K) as they emerge from ring-shadow into springtime conditions, whereas southern mid-latitudes show evidence for cooling (4-6 K). The 40-K asymmetry in stratospheric temperatures between northern and southern hemispheres (at 1 mbar) slowly decreased during the timespan of the observations. Tropospheric temperatures also show temporal variations but with a smaller range, consistent with the increasing radiative time constant of the atmospheric response with increasing pressure. The tropospheric response to the insolation changes shows the largest magnitude at the locations of the broad retrograde jets. Saturn's warm south-polar stratospheric hood has cooled over the course of the mission, but remains present. Stratospheric temperatures are compared to a radiative climate model which accounts for the spatial distribution of the stratospheric coolants. The model successfully predicts the magnitude and morphology of the observed changes at most latitudes. However, the model fails at locations where strong dynamical perturbations dominate the temporal changes in the thermal field, such as the hot polar vortices and the equatorial semi-annual oscillation (Orton, G., and 27 colleagues [2008]. Nature 453, 196-198). Furthermore, observed temperatures in Saturn's ring-shadowed regions are larger than predicted by all radiative-climate models to date due to the incomplete characterization of the dynamical response to the shadow. Finally, far-infrared CIRS spectra are used to demonstrate variability of the para-hydrogen distribution over the 5-year span of the dataset, which may be related to observed changes in Saturn's tropospheric haze in the spring hemisphere.

Fletcher, Leigh N.↗

Spectral perturbations from silicon diode detector encapsulation and shielding in photon fields

Purpose: Silicon diodes are widely used as detectors for relative dose measurements in radiotherapy. The common manufacturing practice is to encapsulate the diodes in plastic for protection and to facilitate mounting in scanning devices. Diodes intended for use in photon fields commonly also have a shield of a high atomic number material (usually tungsten) integrated into the encapsulation to selectively absorb low-energy photons to which silicon diodes would otherwise over-response. However, new response models based on cavity theories and spectra calculations have been proposed for direct correction of the readout from unshielded (e.g., ''electron'') diodes used in photon fields. This raises the question whether it is correct to assume that the spectrum in a water phantom at the location of the detector cavity is not perturbed by the detector encapsulation materials. The aim of this work is to investigate the spectral effects of typical encapsulations, including shielding, used for clinical diodes. Methods: The effects of detector encapsulation of an unshielded and a shielded commercial diode on the spectra at the detector cavity location are studied through Monte Carlo simulations with PENELOPE-2005. Variance reduction based on correlated sampling is applied to reduce the CPU time needed for the simulations. Results: The use of correlated sampling is found to be efficient and to not introduce any significant bias to the results. Compared to reference spectra calculated in water, the encapsulation for an unshielded diode is demonstrated to not perturb the spectrum, while a tungsten shielded diode caused not only the desired decrease in low-energy scattered photons but also a large increase of the primary electron fluence. Measurements with a shielded diode in a 6 MV photon beam proved that the shielding does not completely remove the field-size dependence of the detector response caused by the over-response from low-energy photons. Response factors of a properly corrected unshielded diode were shown to give comparable, or better, results than the traditionally used shielded diode. Conclusions: Spectra calculated for photon fields in water can be directly used for modeling the response of unshielded silicon diodes with plastic encapsulations. Unshielded diodes used together with appropriate corrections can replace shielded diodes in photon dose measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new dose assessment method for the UK system of criticality accident dosimetry - 14420

A new method for the measurement and interpretation of the Harwell criticality accident dosemeter has been developed. The new method treats the dosemeter components as individual detector elements with unique energy-dependent response functions generated with MCNP6. A bespoke deconvolution code was written that generates a parameterized neutron spectrum from the integral activities in each detector element. The spectrum can be folded with any set of fluence-to-dose conversion coefficients to determine an integral dose. The new method has been validated computationally using realistic neutron spectra and experimentally in a series of test irradiations using the Godiva-IV, CALIBAN and PROSPERO critical assemblies. The method was able to reproduce the true dose with a small positive bias and a combined relative uncertainty of 25 % across the full range of spectra considered (10 pGy cm{sup 2} to 45 pGy cm{sup 2}). (authors)

42 ENGINEERING↗

Effect of green light spectra on the reduction of retinal damage and stress in goldfish, Carassius auratus

We investigated the effect of light spectra on retinal damage and stress in goldfish using green (530 nm) and red (620 nm) light emitting diodes (LEDs) at three intensities each (0.5, 1.0, and 1.5 W/m{sup 2}). We measured the change in the levels of plasma cortisol and H{sub 2}O{sub 2} and expression and levels of caspase-3. The apoptotic response of green and red LED spectra was assessed using the terminal transferase dUTP nick end labeling (TUNEL) assay. Stress indicator (cortisol and H{sub 2}O{sub 2}) and apoptosis-related genes (caspase-3) decreased in green light, but increased in red light with higher light intensities over time. The TUNEL assay revealed that more apoptotic cells were detected in outer nuclear layers after exposure to red LED over time with the increase in light intensity, than the other spectra. These results indicate that green light efficiently reduces retinal damage and stress, whereas red light induces it. Therefore, red light-induced retina damage may induce apoptosis in goldfish retina. -- Highlights: •Green light efficiently reduces retinal damage and stress. •Green spectra reduce caspase production and apoptosis. •Red light-induced retina damage may induce apoptosis in goldfish retina. •The retina of goldfish recognizes green spectra as a stable environment.

60 APPLIED LIFE SCIENCES↗

GADRAS-DRF user's manual.

The Gamma Detector Response and Analysis Software-Detector Response Function (GADRAS-DRF) application computes the response of gamma-ray detectors to incoming radiation. This manual provides step-by-step procedures to acquaint new users with the use of the application. The capabilities include characterization of detector response parameters, plotting and viewing measured and computed spectra, and analyzing spectra to identify isotopes or to estimate flux profiles. GADRAS-DRF can compute and provide detector responses quickly and accurately, giving researchers and other users the ability to obtain usable results in a timely manner (a matter of seconds or minutes).

Theisen, Lisa Anne↗

CLARREO shortwave observing system simulation experiments of the twenty-first century: Simulator design and implementation

Projected changes in the Earth system will likely be manifested in changes in reflected solar radiation. This paper introduces an operational Observational System Simulation Experiment (OSSE) to calculate the signals of future climate forcings and feedbacks in top-of-atmosphere reflectance spectra. The OSSE combines simulations from the Intergovernmental Panel on Climate Change (IPCC) Fourth Assessment Report for the NCAR Community Climate System Model (CCSM) with the MODTRAN radiative transfer code to calculate reflectance spectra for simulations of current and future climatic conditions over the 21st century. The OSSE produces narrowband reflectances and broadband fluxes, the latter of which have been extensively validated against archived CCSM results. The shortwave reflectance spectra contain atmospheric features including signals from water vapor, liquid and ice clouds, and aerosols. The spectra are also strongly influenced by the surface bidirectional reflectance properties of predicted snow and sea ice and the climatological seasonal cycles of vegetation. By comparing and contrasting simulated reflectance spectra based on emissions scenarios with increasing projected and fixed present-day greenhouse gas and aerosol concentrations, we find that prescribed forcings from increases in anthropogenic sulfate and carbonaceous aerosols are detectable and are spatially confined to lower latitudes. Also, changes in the intertropical convergence zone and poleward shifts in the subsidence zones and the storm tracks are all detectable along with large changes in snow cover and sea ice fraction. These findings suggest that the proposed NASA Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission to measure shortwave reflectance spectra may help elucidate climate forcings, responses, and feedbacks.

54 ENVIRONMENTAL SCIENCES↗

Probing magnetic and electric optical responses of silicon nanoparticles

We study experimentally both magnetic and electric optically induced resonances of silicon nanoparticles by combining polarization-resolved dark-field spectroscopy and near-field scanning optical microscopy measurements. We reveal that the scattering spectra exhibit strong sensitivity of electric dipole response to the probing beam polarization and attribute the characteristic asymmetry of measured near-field patterns to the excitation of a magnetic dipole mode. The proposed experimental approach can serve as a powerful tool for the study of photonic nanostructures possessing both electric and magnetic optical responses.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Characterization of Deuterated-xylene Scintillator as a Neutron Spectrometer

We have experimentally characterized the neutron light output response functions of a deuterated-xylene scintillator for neutron energies lower than 10 MeV. We then used the response matrix to unfold the energy distribution of neutrons produced via several reactions, i.e. spontaneous fission, d(d,n)3He, 27Al(d,n)28Si, and 9Be(alpha,n)12C. Organic scintillators based on deuterated compounds show a fast response and good gamma-neutron discrimination capability, similar to proton-based scintillators. Deuterated scintillators can also effectively provide neutron spectra by unfolding measured data with the detector response matrix, without the need of time-of-flight. Deuteron recoils, produced by elastic collisions between deuterium and impinging neutrons, are preferentially forward-scattered. This non-isotropic reaction results in distinct peaks in the response functions to monoenergetic neutrons. In this work, we evaluated a custom-fabricated 7.62 cm x 7.62 cm deuterated-xylene (EJ301D) liquid scintillator. This liquid has a low volatility and higher flash point, compared to benzene-based deuterated detectors, e.g. EJ315 and NE230. We measured the EJ301D detector neutron response matrix (up to 6 MeV neutron energy) using an intense Cf252 source and the time-of-flight technique. The number of response functions obtained using our method is only limited by counting statistics and by the experimentally achievable energy resolution. Multi-channel unfolding was performed successfully for neutron spectra with different energy spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Propagation of priors for more accurate and efficient spectroscopic functional fits and their application to ferroelectric hysteresis

Multi-dimensional spectral-imaging is a mainstay of the scanning probe and electron microscopies, micro-Raman, and various forms of chemical imaging. In many cases, individual spectra can be fit to a specific functional form, with the model parameter maps, providing direct insight into material properties. Since spectra are often acquired across a spatial grid of points, spatially adjacent spectra are likely to be similar to one another; yet, this fact is almost never used when considering parameter estimation for functional fits. On datasets tried here, we show that by utilizing proximal information, whether it be in the spatial or spectral domains, it is possible to improve the reliability and increase the speed of such functional fits by ~2-3x, as compared to random priors. We explore and compare three distinct new methods: (1) spatially averaging neighborhood spectra, and propagating priors based on functional fits to the averaged case, (2) hierarchical clustering-based methods where spectra are grouped hierarchically based on response, with the priors propagated progressively down the hierarchy, and (3) regular clustering without hierarchical methods with priors propagated from fits to cluster means. Our results highlight that utilizing spatial and spectral neighborhood information is often critical for accurate parameter estimation in noisy environments, which we show for ferroelectric hysteresis loops acquired on a prototypical PbTiO3 thin film with piezoresponse spectroscopy. This method is general and applicable to any spatially measured spectra where functional forms are available. Examples include exploring the superconducting gap with tunneling spectroscopy, using the Dynes formula, or current-voltage curve fits in conductive atomic force microscopy mapping. Here we explore the problem for ferroelectric hysteresis, which, given its large parameter space, constitutes a more difficult task than, for example, fitting current-voltage curves with a Schottky emission formula.

42 ENGINEERING↗

Validation of neutron emission profiles in MAST with a collimated neutron monitor

A neutron camera with liquid scintillator detectors is used in MAST to measure the neutron emissivity from D(d,n){sup 3}He reactions along collimated lines of sight. In this work, the measured recoil proton pulse height spectra generated in the detectors by the incident neutrons is modelled taking into account the energy spectrum of the generated neutrons, their spatial distribution and transport to the detectors as well as the detector's response function. The contribution of scattered neutrons to the pulse height spectrum is also modelled. Good agreement is found between the experimental data and the simulations. Examples are given showing the sensitivity of the recoil proton pulse height spectra to different observation angles with respect the neutral beam injection and the plasma rotation direction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RadSim: Detector Response

This package simulates the expected output gamma spectra from a gamma detector for given configuration.

Hangal, DhanushA [Lawrence Livermore National Labo↗